Professional Documents
Culture Documents
223 Flow Control and Check Valve
223 Flow Control and Check Valve
Ratings
Model Numbers FG - 01 4 -*-11 8 FCG FG - 02-30-*-22801 FCG FG - 03-125-*-22801 FCG Max. Metered Flow Capacity l/min 4 8 30 125 Min. Metered Flow Capacity l/min 0.02 (0.04)* 0.05 210 0.2 7.9 Max. Operating Pressure kgf/cm2 140 Mass kg
1.3 3.8
FC
Series Number F:
G
Type of Mounting
-01
Valve Size 01
-8
Max. Metered Flow Capacity l/min 4:4 8:8 30:30 125:125
-N
Pres. Compensator Stroke Adjustment N: Applicable only for Pres. Conpensator Stroke Adjustment (option) (Omit if not required)
-11
Design Number 11
G: Sub-Plating Mounting 02
22801
03
22801
Also available with locking feature with key & model no. Please refer drawing
FG 02 - * - * - 22801HO1 03
Attachment
Mounting Bolts
Valve Model Number F*G-01 F*G-02 F*G-03 Socket Head Cap Screw M5 x 55 Lg. M8 x 60 Lg. M10 x 80 Lg. Qty. 4 4 4 Bolt Kit Model Number BKFG - 01-10 BKFG - 02-22 BKFG - 03-22
Graphic Symbols
FG
Option
Pres. compensator stroke adjustment Can reduce jumping at the start of the actuator
FCG
Subplates are available. Specify sub-plate model from the table above. When sub-plates are not used the mounting surface should have a good machined finish.
Instructions
Min. required pressure difference
Min required pressure differential between inlet and outlet port is required to obtain the optimum pressure compensation. It varies accordingly to the flow rate to be set. For details, please refer to the performance curve.
Free flow
Check valve pressure drops vary with flow rates. If models with check valves are used, see free flow pressure drop characteristics.
Flow adjustment
[F*G - 01] Loosen locking screw and turn flow adjustment dial clockwise for increase, and anti-clockwise for decrease. The dial makes about 4 revolutions from zero to full flow and the valve opening is indicated on the revolution indicator. (Refer to characteristic of "Metered Flow vs. Dial Position") Also Flow adjustment, tighten locking screw. [F*G - 02/03] ---- Anticlockwise for increase and clockwise for decrease.
Line filter
To carry out flow adjustments by as small degree as 2 l/min of less, be sure to use a line filter, 10 m or less, near the valve inlet.
FG -01-*-*-11 FCG
DIMENSION IN MILLIMETERS
121
FLOW CONTROLS
F*G-02-30-*-22801/22801H01
Locking Feature with key
160 (Fully Extended) 137 (Fully Extended)
KEY
(Fully Extended)
140 71 50 23 6
9.9
Controlled flow inlet or reversed free flow outlet Controlled flow outlet or reversed free flow inlet Mounti ng Surface ( ORings furnished)
F*G-03-125-*-22801/22801H01
DIMENSION IN MILLIMETERS
Locking Screw
Revolution Indicator 79 Fully Extended Controlled flow inlet or reversed free flow outlet Pressure Compensation Stroke Adjustment for 'N' Models only
149.4 12.5 11.7 HD Thru. 17.5 Spot Face 4 Places 50.8 101.6
152 100 65 41
6 Two Location PIN Mounting Surface (O-Rings Furnished) Controlled flow outlet or reversed free flow inlet
D
DIMENSION IN MILLIMETERS
02 FGM-02X-2080 02Y
Sub-Plate 'O' Thd. Model BSP.F Number 1/4 FGM-02-2080 FGM-02X-2080 3/8 FGM-02Y-2080 1/2
B
A 11.7 15.2 15
B 54 54 51
C 11.1 11.1 14
9.5
Weight Sub-Plate D Approx. Model kgf. Number FGM-02-2080 25 2.3 FGM-02X-2080 25 2.3 FGM-02Y-2080 35 3.1
'O' Thd. 2 Places D
03 FGM-03X-2080 03Y
C 18 18 18
E 75 70
F 20.6 25.6
G 11.1 16.1
H 86.5 81.5
J 25 40
123
cSt
kgf/cm2
FG FCG -02- 30
FG FCG -02- 30
cSt
kgf/cm2
cSt
kgf/cm2
1. For any other viscosity, multiply by the factors in the table below.
Viscosity Factor cSt SSU 20 98 0.87 40 186 1.03 60 278 1.14 80 371 1.23 100 464 1.30
2. For any other specific gravity, use the formula : G' P' = P G Where P is each value in the chart above, and G is 0.850 specific gravity.
FLOW CONTROLS
Metered Flow Vs. Dial Position
FG 4 -01 FCG 8
FG 4 -01 FCG 8
l/min
FG FCG -02- 30
kgf/cm2
FG -02- 30 FCG
kgf/cm2
FCG -02- 30
l/min
kgf/cm2
125