The BTS3012 power subsystem consists of the power distribution units in the cabinet. It provides
stable power supply for the BTS3012 through mechanisms such as lightning protection and E1
filtering.
-48 V DC DC lighting
EMI filter Busbar Load
arrester
DC Power Distribution
Figure 7-2 shows the power distribution in the BTS3012 when the external –48 V DC power
input is used.
DC lightning arrester
DAFU
subrack
DTRU
PGND
+
V-
B subrack
V+
u
s
-48V -48V GND GND
-48V -48V GND GND
Common
b subrack
-48V DC a
r
Fan
- BBU
EMI filter
PGND cable
GND cable
- 48 V DC power cable
The external power input is processed through the DC lightning arrester and the EMI filter, and
then sent to the equipment in the cabinet through the 13 power switches on the busbar.
Table 7-1 lists the relation between the power switches on the Busbar and the equipment in the
cabinet.
Table 7-1 Relation between the power switches and the equipment
Power Switch Equipment
SW 8 Fan subrack
SW 12 Common subrack
When the external +24 V DC power input is used, a DC/DC Sidepower power cabinet should
be configured with the BTS3012 to convert the external +24 V DC to –48 V DC. Figure 7-3
shows the power distribution in the BTS3012.
DC lightning arrester
DAFU
subrack
DTRU
PGND
+
V-
B subrack
V+
u
-48V -48V GND GND
s Common
-48V -48V GND GND
+24V DC DC/DC
Sidepower b subrack
cabinet -48V DC a
r
Fan
- BBU
EMI filter
PGND cable
GND cable
- 48 V DC power cable
AC Power Distribution
When the external 220 V AC or 110 V AC power input is used, an AC/DC Sidepower power
cabinet should be configured with the BTS3012 to convert the 220 V AC or 110 V AC to –48
V DC. Figure 7-4 shows the power distribution in the BTS3012.
DC lightning arrester
DAFU
subrack
DTRU
PGND
V-
+ B subrack
V+
u
- BBU
EMI filter
PGND cable
GND cable
- 48 V DC power cable