GAS PRODUCT SOLUTIONS

Technical Performance
Gas turbine range

The ideal solution for all applications


Alstoms gas turbines offer outstanding performance, operational and fuel exibility as well as availability and reliability. Alstoms gas turbines are the ideal solution for all applications (simple-cycle, combined-cycle, co-generation etc.) and operating proles.

Superior value from proven technology Todays products already feature tomorrows requirements Evolutionary product development for highly reliable products
GT26 GT24

KEY BENEFItS Advanced-class gas turbine technology with superior part-load efciency and operational exibility. Superior fuel exibility for operating over the widest range of natural gas compositions.

GT26
Fuel

Advanced-class gas turbine


Natural Gas 50 Hz 3,000 rpm 326.0 MW 40.3% 8,933 kJ/kWh | 8,467 Btu/kWh 35.0 : 1 692 kg/s | 1,526 Ib/s 603 C | 1,117 F 406 t | 895,000 lb 12.04.95.5 m | 391618 ft Frequency Turbine speed Gross electrical output Gross electrical efciency Gross heat rate Compressor pressure ratio Exhaust gas ow
TPWR/PRSHT/TPGTR/EN/10.2013/CHE/1714

GT24
Fuel

Advanced-class gas turbine


Natural Gas 60 Hz 3,600 rpm 230.7 MW 40.0% 9,000 kJ/kWh | 8,531 Btu/kWh 35.4 : 1 505 kg/s | 1,113 Ib/s 597 C | 1,107 F 230 t | 507,000 lb 10.74.04.6 m | 351315 ft Frequency Turbine speed Gross electrical output Gross electrical efciency Gross heat rate Compressor pressure ratio Exhaust gas ow Exhaust gas temperature Weight Dimensions (LWH)

Exhaust gas temperature Weight Dimensions (LWH)

General notes: Gas turbine gross electrical output and heat rate at the generator terminals, including gear box, where applicable and generator losses but excluding duct and auxiliary losses. Performance calculated with 100% methane, ISO conditions. GT24/GT26 performance includes contribution of Once-Through Cooler (OTC) to water/steam cycle. Dual fuel burner option available

ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection of the environment. This leaet is printed on environmentally-friendly paper.

GAS PRODUCT SOLUTIONS TECHNICAL PERFORMANCE GAS tURBINE RANgE

GT13E2

Conventional-class gas turbine


CONFIGURAtION Fuel Frequency Turbine speed Gear Gross electrical output Gross electrical efciency Gross heat rate Compressor pressure ratio Exhaust gas ow Exhaust gas temperature Weight Dimensions (LWH) 2005 Natural Gas 50 Hz 3,000 rpm No 185.0 MW 37.8% 9,524 kJ/kWh 9,027 Btu/kWh 16.9 565 kg/s 1,245 lb/s 505 C 941 F 343 t 756,185 lb 11.25.45.2 m 36.717.717.0 ft MXL2 Natural Gas 50 Hz 3,000 rpm No 188.0 MW 38.6% 9,326 kJ/kWh 8,840 Btu/kWh 17.5 548 kg/s 1,208 lb/s 512 C 954 F 343 t 756,185 lb 11.25.45.2 m 36.717.717.0 ft 2012 Natural Gas 50 Hz 3,000 rpm No 202.7 MW 38.0% 9,474 kJ/kWh 8,980 Btu/kWh 18.2 624 kg/s 1,376 lb/s 501 C 934 F 350 t 772,000 lb 11.05.45.5 m 361818 ft

GT13E2

KEY BENEFItS Conventional-class gas turbine technology with superior performance and a unique exible operation concept. Superior fuel exibility for operating over the widest range of natural gas compositions.

GT11N2

GT11N2
Fuel

Conventional-class gas turbine


Natural Gas 50 Hz 3,610 rpm Yes 113.6 MW 33.3% 10,811 kJ/kWh 10,247 Btu/kWh 15.9 : 1 400 kg/s 882 Ib/s 526 C 979 F 190 t 419,000 lb 13.15.510.1 m 431833 ft Natural Gas 60 Hz 3,600 rpm no 115.4 MW 33.9% 10,619 kJ/kWh 10,066 Btu/kWh 15.9 : 1 400 kg/s 882 Ib/s 526 C 979 F 190 t 419,000 lb 9.45.510.1 m 311833 ft Frequency Turbine speed Gear Gross electrical output Gross electrical efciency Gross heat rate Compressor pressure ratio Exhaust gas ow Exhaust gas temperature Weight Dimensions (LWH)*
TPWR/PRSHT/TPGTR/EN/10.2013/CHE/1714

KEY BENEFItS Proven technology designed for operation under harshest conditions. Ideal for power production in steel plants, where Blast Furnace Gas (BFG) can be burnt directly, without need for enrichment.

For more information please contact Alstom Power: Alstom Power Brown Boveri Strasse 7 5401 Baden Switzerland Phone: +41 58 505 7733 Visit us online: www.alstom.com

* Length includes the gear box General note: Dual burner option available, as well as combustor for low caloric gases (LBtu) such as blast furnace gases without need for enrichment.

ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection of the environment. This leaet is printed on environmentally-friendly paper.