Delivery Programme
Waterstops
Waterstops
Delivery Programme
Page Tricosal waterstops and profiles Quality, Technical Advice, Service Survey of Materials / General Information Description of materials Expansion joint waterstops, internal Construction joint waterstops, internal Expansion joint waterstops, external Construction joint waterstops, external Waterstops for capping joints Waterstops for flanging construction Crack Inducer Tubes Waterstops for pre-cast constructions Compression Seals Polyethylene (PE) waterstops Equipment, Tools, Auxiliaries Intersections and Systems 3 4 5 6/7 8/9 10/11 12/13 14/15 16-19 20 21 22 23 24 25
Tricoplan Membrane fixing and partition profiles for PVC-P or PE waterproofing membranes 26/27
Description of Fire Protection System for Joints Brand-Ex and Compression Seals
28 29
30
General Information
31
Waterstops
Quality, Technical advice, Service
Quality / Supervision
Tricosal waterstops are subject to a production quality assurance scheme. The supervision is carried out by the Staatliches Materialprfungsamt Nordrhein-Westfalen (MPA NRW) Federal Institute for Materials Testing, Dortmund.
Test Reports
Test reports showing physical and chemical properties are available on request.
The correct joint designs are a fundamental design factor in the efficiency of any structure. Our experienced engineers can offer expert advice to customers for joint design, waterstop material, profiles during the design, tendering or construction stages, to ensure the correct decisions are made.
Dimensions / Tolerances
1) Thermoplastic waterstops For waterstops according to DIN 18541 minimum dimensions are specified. For all other profiles the following tolerances are applicable: Dimensions Dimensions Dimensions Dimensions up to 10 mm: from 11- 50 mm: from 51- 250 mm: > 250 mm: Tolerance Tolerance Tolerance Tolerance 15 % 10 % 5% 4%
2) Elastomeric (rubber) waterstops Dimensions and tolerances as specified in DIN 7865 are applicable.
Profile shapes
Due to the physical properties of the thermoplastic materials, PVC-P and Tricomer, used in the waterstops, shape loss may occur in adverse temperature conditions, incorrect storage or transportation. To rectify this thermal treatment at 60 - 80 C is used. This is especially recommended when handling waterstops during low temperature periods and in case of external type waterstops with higher anchoring ribs.
Waterstops
Survey of materials General information
Design, dimensions and physical properties were developed and specified by Tricosal, have a proven success for many years.
Design, minimum dimensions and physical properties are as specified by the DIN standard.
Quality Control
External and independent supervision by MPA Dortmund, together with in-house quality control system QA/QC. Jointing by heated wedge or hot air welding tools or by semi-automatic welding machines available from Tricosal.
Jointing
Elastomer
Elastomer according to DIN 7865 part 1 + 2 Elastomer according to DIN 7865 part 2 Elastomer with fabric reinforcement
Dimensional stability against hot bitumen Design, dimensions and physical properties are specified in the DIN standard. Physical properties are specified in the DIN standard. Design and dimensions were developed by Tricosal. Profiles for flanging constructions with nylon fabric reinforcement.
External and independent supervision by MPA Dortmund, together with in-house quality control system QA/QC. By vulcanising (On site, only butt joints can be made by using vulcanising units which are available on hire.)
In-house quality control system QA/QC. By vulcanising (Intersections and butt jointing only by Tricosal)
Waterstops
Description of materials
PVC-P
This material provides a wide spectrum of excellent properties at economic costs. It has been in use for more than 70 years. Tricosal PVC-P waterstops are resistant against natural acidic and alkaline agents, resistant to ageing, with total homogeneous weldability being achieved. The following grades are offered
1 2 3
10 275 75 5
10 275 75 5
standard quality waterstops, not resistant to bitumen (PVC-P/NB) 4 bitumen resistant waterstops according to DIN 16937 (PVCP/BV) potable water quality waterstops (PVC-P/PH), available on special request Behaviour after storage on bitumen (in accordance to DIN 16937- 28 days/70 C) Change in %: Tensile Strength Elongation at break Modulus of elasticity 16726
20 20 50
Tricomer
according to DIN 18541 Tricomer is a combination of PVC-P and NBR (nitrile butadiene rubber) materials/compounds. This special polymer was developed in our laboratories and has been modified to meet DIN requirements. The Tricomer material has been successfully used for nearly 20 years for the waterproofing of joints in concrete structures. Tricomer has a high elongation at break, excellent resistance to chemicals and ageing, together with a constant elasticity similar to elastomer (rubber). It is used where a higher performance of the structure and the joint waterproofing is required. Tricomer waterstops are jointed by thermoplastic welding and thus facilitate the practical use. Tricomer waterstops are offered in the grades NB (not resistant to bitumen) and BV (bitumen resistant according to DIN 18541).
1 2 3
Tensile Strength in N/mm2 Elongation at break Shore-A-Hardness in % Tear Strength in N/mm2 Behaviour at low temperatures (-20C), Elongation at break in N/mm2 Behaviour after storage in bitumen (28 days/70 C) Change in %: Tensile Strength Elongation at break Modulus of elasticity
10 350 67 5 12
10 350 67 5 12
53 507
53 455
200
200
20 20 50
Elastomer (rubber)
according to DIN 7865 Wide screened and interlaced high polymers (artificial rubber) in a vulcanised state are called Elastomer. The process of interlacing is non-reversible, therefore a special jointing process is required. Tricosal elastomeric waterstops (internal and external types) are used for structures with large joint movements, frequent load changes and/or low temperatures as well as for high water pressures. The visual surface of the FFK-capping joint profiles have a grey and UV-stable vulcanised covering.
Physical Properties
No. Property
(Extract of DIN 7865 part 2) Test methods to DIN 53 504 53 504 53 505
requirements 10 380 62 5 8
1 2 3
Tensile Strength in N/mm2 Elongation at break in % Shore-A-Hardness Tear Strength in N/mm2 Behaviour at low temperatures (-20C), Shore-A-Hardness Dimensional stability when exposed to hot bitumen Metal adhesion
53 507
53 505
90
6 7
7865 7865
PVC-P
Standard Quality
Total width
Width Thickness Width of of of expan- expan- sealing sion part sion part part b 75 85 110 155 120 170 120 c 3,5 4 5 6 6 6 9 s 58 78 105 173 65 75 100
Tricomer
DIN 18541
Total width
Width Thickness Width of of of expan- expan- sealing sion part sion part part b 75 85 110 155 120 170 120 120 c 4 4,5 5,5 6,5 6 6 9 9 s 58 78 105 173 65 75 65 100
a D D D D 190 240 320 500 190 240 320 500 250 320 250 320
Elastomer (rubber)
FM ... H S
DIN 7865
Total width
Width Thickness Width of of of expan- expan- sealing sion part sion part part b 110 125 175 180 230 300 c 9 9 10 12 12 13 s 45 63 63 85 85 100
a FM FM FM FM FM FM 200 250 300 350 400 500 200 250 300 350 400 500
FM
DIN 7865 part 2 FM 250-2 FM 300-2 FM 350-2 250 300 350 125 175 180 8 8 9 63 63 85 20 20 20 26 28 30
Expansion Joint waterstop with encased centre bulb FM 350 HS 350 180 12 85 35 38
PVC-P
Standard Quality
Total width
Width Thickness Width of of of expan- expan- sealing sion part sion part part b c s
Expansion joint waterstops, externally reinforced with fixing loops: SFD 24 SFD 32 240 320 85 100 4 4,5 78 110 20 20 15 15
Expansion joint waterstops, omega shape: OM 25 OM 35 OM 50 250 350 500 75 95 190 6 6 7 88 128 155 30 40 50 15 15 20
Tricomer
DIN 18541, part 2
Total width
Width Thickness Width of of of expan- expan- sealing sion part sion part part b c s
Expansion joint waterstops, externally reinforced with fixing loops: D 240 SF D 320 SF 240 320 85 110 4,5 5 78 105 20 20 15 15
Expansion joint waterstops, thick sections: D 260 TS D 350 TS D 400 TS 260 345 395 125 175 195 9 11 11 68 85 103 20 20 20 24 27 29
Elastomer (rubber)
DIN 7865
Total width
Width Thickness Width of of of expan- expan- sealing sion part sion part part* b c s
Expansion joint waterstops with steel plates: FMS 350 FMS 400 FMS 500 350 400 500 120 170 230 10 11 12 45 45 65 20 20 20 32 32 32
Expansion joint waterstops with steel plates and pre-formed, encased centre-bulb FMS 400 HS FMS 500 HS 400 500 170 230 11 12 45 65 35 35 32 32
The profile range FMS HS is especially suitable for wide joints and contraction joints; but also for normal expansion joints when subsidence and seismic movements are expected.
PVC-P
Standard Quality
Total width a
Width of Thickness Width of Height of expansion of expansealing anchoring part sion part part ribs b 45 75 85 110 155 c 3 3 3.5 4.5 6 s 52.5 57.5 77.5 105 172.5 f 10 15 15 15 20
A A A A A
15 19 24 32 50
Construction joint waterstops, with internal steel bar reinforcement: FIX 20 FIX 24 FIX 32 200 240 320 70 80 100 3,5 3,5 4 65 80 110 15 15 15
Tricomer
DIN 18541
Total width a
Width of Thickness Width of Height of expansion of expansealing anchoring part sion part part part b 75 85 110 155 c 3.5 4 5 6,5 s 57.5 77.5 105 172.5 f 15 15 15 20
A A A A
Construction joint waterstops, with internal steel bar reinforcement: A 190 FIX A 240 FIX A 320 FIX 200 240 320 70 80 100 3.5 4 5 65 80 110 15 15 15
Elastomer (rubber)
DIN 7865
Total width a
Width of Thickness Width of Height of expansion of expansealing anchoring part sion part part part b 75 80 100 c 7 8 8 s 62.5 85 100 f 32 32 32
75 80 100
6 6 6
62.5 85 85
32 32 32
PVC-P
Standard Quality
Total width a
Width of Thickness Width of Height of expansion of expansealing anchoring part sion part part part b c s f
Construction joint waterstops, externally reinforced with fixing loops: SFA 20 SFA 24 SFA 32 200 240 320 75 70 110 3 3,5 4 62.5 85 105 15 15 15
Tricomer
DIN 18541, part 2
Total width a
Width of Thickness Width of Height of expansion of expansealing anchoring part sion part part part b c s f
Construction joint waterstops, externally reinforced with fixing loops: A 200 SF A 240 SF A 320 SF 200 240 320 75 70 110 3,5 4 5 62.5 85 105 15 15 15
Construction joint waterstops, thick sections: A 260 TS A 320 TS 260 320 113 165 9 10 72.5 77.5 24 26
Elastomer (rubber)
DIN 7865
Total width a
Width of Thickness Width of Height of expansion of expansealing anchoring part sion part part part b c s f
Construction joint waterstops with steel plates: FS 270 FS 310 270 310 60 80 7 8 105 115 22 22
PVC-P
Standard Quality
Total width a
Width of Web expansion thickness part b 92 90 90 104 104 104 104 124 124 124 c 3,5 4 4 4,5 4 4 4,5 4 4 4,5
190 240 240 240 330 330 330 500 500 500
Tricomer
DIN 18541
Total width a
Width of Web expansion thickness part b 90 90 104 104 104 104 124 124 124 c 4,5 4,5 5 4,5 4,5 5 4,5 4,5 5
Elastomer (rubber)
DIN 7865
Total width a
250 350
100 100
5.5 5.5
36 36
4 6
10
PVC-P
Standard Quality
Width of Web expansion thickness part b1/b2 71/55 71/55 79/63 79/63 c 4 4 4 4
Tricomer
DIN 18541 part 2
Width of Web expansion thickness part b1/b2 71/55 71/55 79/63 79/63 c 4.5 4.5 4.5 4.5
11
PVC-P
Standard Quality
Total width a
Width of Web expansion thickness part b 92 90 85 104 104 104 104 124 124 124 c 3.5 4 4 4.5 4 4 4.5 4 4 4.5
190 240 240 240 330 330 330 500 500 500
Tricomer
DIN 18541
Total width a
Width of Web expansion thickness part b 90 90 104 104 104 104 124 124 124 c 4.5 4.5 5 4.5 4.5 5 4.5 4.5 5
Elastomer (rubber)
DIN 7865
Total width a
250 350
100 100
5.5 5.5
36 36
4 6
12
PVC-P
Standard Quality
Width of Web expansion thickness part b1/b2 61/45 61/45 45/45 68/52 68/52 52/52 c 4 4 4 4 4 4
Tricomer
DIN 18541 part 2
Width of Web expansion thickness part b1/b2 61/45 61/45 45/45 68/52 68/52 52/52 c 4.5 4.5 4.5 4.5 4.5 4.5
AA 240 edge A AA 240 edge W AA 240 edge I AA 320 edge A AA 32 edge W AA 320 edge I
13
PVC-P
Standard Quality
Total Height Width Web Joint Sealing ribs width of of joint thick- width loop cover ness * part Height No. a I 35 35 35 35 50 50 35 35 40 40 35 35 b 20 20 30 30 30 50 30 30 40 60 30 30 c 5 5 5 5 5 5 5 5 5 5 5 5 k 10 10 20 20 20 40 20 20 30 50 20 20 f 25 35 25 35 45 45 25 35 35 35 25 35 N 2 2 2 2 2 2 4 4 4 4 6 6
FF 5/2 FF 5/2/3 FF 5/3 FF 5/3/3 FF 7/3 FF 7/5 FF 10/3 FF 10/3/3 FF 14/4 FF 14/6 FF 14/3 FF 14/3/3
Tricomer
DIN 18541
Total Height Width Web Joint Sealing ribs width of of joint thick- width loop cover ness * part Height No. a I 35 35 35 50 50 35 35 40 40 35 35 b 20 30 30 30 50 30 30 40 60 30 30 c 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 k 10 20 20 20 40 20 20 30 50 20 20 f 35 25 35 45 45 25 35 35 35 25 35 N 2 2 2 2 2 4 4 4 4 6 6
FA 50/2/3** FA 50/3/2 FA 50/3/3 FA 70/3/4 FA 70/5/4 FA 90/3/2 FA 90/3/3 FA 130/4/3** FA 130/6/3** FA 130/3/2 FA 130/3/3 ** DIN 18541 part 2
Elastomer (rubber)
DIN 7865 part 2
Total Height Width Web Joint Sealing ribs width of of joint thick- width loop cover ness * part Height No. a I 35 35 50 50 50 35 35 b 20 30 30 40 50 30 30 c 5 5 5 5 5 5 5 k 10 20 20 30 40 20 20 f 35 35 45 45 45 45 35 N 2 2 2 2 2 4 6
FFK 5/2 FFK 5/3 FFK 7/3 FFK 7/4 FFK 7/5 FFK 10/3 FFK 14/3
55 55 70 70 70 100 145
* The profiles are designed for the given joint width (k). They can also be used for joints up to 10 mm.
14
PVC-P
Standard Quality
Total width
Web thickness c 10
Joint width*
Sealing ribs
Height k 10 f 25
Number N 2
a FF 7/2 P 70
Tricomer
DIN 18541 FA 130/3 P 140 30 15 20 35 6
For areas with surface loads (e.g. traffic areas and car parks) profiles with a thicker cover part are recommended.
PVC-P
Standard Quality
Total width a
Web thickness c 5
FF 5/5/15
50
Tricomer
DIN 18541 part 2 FA 5/5/15 50 30 6 45 1
The 150 mm long flat leg of the profile is used as connector to waterproofing membranes.
Joint width k 10 20 30 40
Visible width b 20 30 40 50
Height of chamfer e 15 15 15 15
Width of spacer g 50 60 70 80
Length
* The profiles are designed for the given joint width (k). They can also be used for joints up to 10 mm.
15
Flanging Constructions
Tricomer
DIN 18541 part 2
a2 f c s
D 320 K
Width Width Height Total Width of Web of of centre of anexpanwidth thickness sealing bulb choring sion part part ribs a1/a2 179/170 b 95 c 5 s 95 k 22 f 23
Elastomer (rubber)
DIN 7865 part 2 FM 350 K 195/200 115 10 85 40 38
a1
Tricomer
DIN 18541 part 2
Width of Web Width of Height of expansion thickness centre sealing part bulb ribs b 88 88 c 5 5 k 22 22 f 35 35
a2
DA 320 K I DA 320 K A
179/204 179/204
Elastomer (rubber)
DIN 7865 part 2 AM 350 K I AM 350 K A 166/211 166/211 86 86 6 6 36 36 31 31
f c
KI
KA
a1
Protection Profile
for one-sided flanging constructions Height
Width of chamber b 65
Joint width
k 50
KSP provides space for joint movements in case of a one-sided flanging construction
fixing strip
movement chamber
16
Flanging Constructions
Elastomer (rubber)
DIN 7865 part 2
Total width a
Web thickness c 12
FM 350 KF
350
Tricomer
DIN 18541 part 2
Total width a
Web thickness c 5
DA 320 KF
320
Elastomer (rubber)
DIN 7865 part 2 AM 350 KF 350 6 20 31
5 6
17
Flanging Constructions
for waterproofing of existing joints
(both legs flanged)
Tricomer
DIN 18541 part 2
Total width a
Web thickness b 5
FP 300*
300
Elastomer (rubber)
FPK FPK FPK FPK FPK 250 300 350 400 500 250 300 350 400 500 4 4 4 4 4
Elastomer (rubber)
DIN 7865 part 2
Total width a
Web thickness c 12
FMG 350*
350
Tricomer
DIN 18541 part 2 Total width a LF 320* 320
Width of Web Width of Height of expansion thickness centre centre part bulb bulb b o. r. c 5 k 20 f 25
Elastomer (rubber)
DIN 7865 part 2 AMG 350* 350 o. r. 6 25 31
18
Flanging Constructions
for waterproofing of existing joints
Loose-/fixed flange constructions Loose flange constructions
Elastomer (rubber)
Non-reinforced
Total width a
Width of Web Width of expansion thickness loop part b 130 184 c 8 8 k 96 156
Height of loop f 68 78
OK 24 OK 30
240 300
Elastomer (rubber)
fabric reinforced
16 24 30 35
8 8 8 9
31 96 156 200
42 68 78 100
Jointing: angle fabrications can only be factory made, butt jointing on site must be carried out by Tricosal applicators Fixing and installation is carried out without perforation of the profiles For further please contact our technical department.
Tricomer
DIN 18541 part 2
Total width a
Height of loop f 60
ZW 360
360
Elastomer (rubber)
Non-reinforced O 380 380 100 10 80 40
Elastomer (rubber)
fabric reinforced OG 380 380 100 10 80 40
The fanging waterstop profiles ZW 360, O 380 and OG 380 can be used for both, loose flange or loose-/fixed flange constructions
19
PVC-P
Total width a
Diameter
d 64 88 175
Use:
Anchor ribs
c
f
Inner tube made of rigid PVC Cuts (to be made on site) to attach SR to a construction joint waterstop Crack Inducer SR KAB 125 Approx 50 mm
SR 6: for Pre-Cast Double Walls (Hollow Elements) and thin walls SR 9: for walls up to 350 mm thickness SR 18: for walls from 300 to approximate 600 mm thickness
Advantages:
Easy and safe installation Tested and approved waterproofing Controlled shrinkage cracking by reducing the cross section Waterproofing of the shrinkage crack by anchoring ribs of the tube Can be combined with KAB or FIX waterstops of the slab/wall waterproofing
Installation Instructions
A cut of approx. 6 cm is made in the under side of the crack inducer which is then pressed onto the Tricosal construction joint waterstop type FIX. A clearance of approx. 5 cm must be left from the slab. The crack inducer is supported in the upper wall by lateral timber supports fixed to the shuttering. The induction of cracks is controlled by triangular fillets installed on both sides of the concrete wall. If non-reinforced PVC waterstop is used, then a steel strip of approx. 40 cm length must be placed in he concrete behind the waterstop, opposite to the water side, to support the crack inducer. The internal pipe of the crack inducer can be filled during subsequent concreting. This must be done in all civil defence buildings.
20
Waterstops
for pre-cast constructions
PVC-P
Standard Quality
Total width a
Joint width k 30
GK 5 AF 6
80 60
Tricomer
DIN 18541 part 2 GK 50 AA 60 80 60 50 50 5 5 30 20 30
PVC-P
Standard Quality
Total width a
Joint width k 30
GK 10/3
140
Tricomer
DIN 18541, part 2 GK 100/3 140 100 5,5 35 30
Tricomer
DIN 18541, part 2
Total width a
Joint width k 30
GK 100/3 T
140
In the centre of this profile system a hydrophillic rubber is placed as an additional security.
21
Compression Seals
UV-light and weathering resistant
Tricomer grey
DIN 18541 part 2
Joint width K
Width of profile B 20 30 40
Height of profile H 22 30 40
Thickness C 2 3 4
Tricomer
Joint width K
Width of profile B 15 30 35 50 66 80
Height of profile H 35 30 35 45 43 50
F F F F F F
* with width cover plate for overlapping joint flanges by approx. 15 mm ** multi hollow chambers, see MK types
Tricomer grey
DIN 18541 part 2
Joint width K
Height of profile H 34
Thickness C 5
F 28/30 corner
17-23
22
PE
modified
Total width a
Expansion joint waterstops PED 240/25 PED 320/25 240 330 110 110 4 4 30 30 4 6
PE
modified
Total width a
Construction joint waterstops PEA 240/25 PEA 320/25 240 330 110 110 4 4 30 30 4 6
Material Supply
Thermoplastic PE- Copolymer, plasticised, which especially has been developed for the waterproofing of structures. black colour 20 m rolls; 5 m bars
Special properties
100% recyclable excellent chemical resistance (equivalent with thermoplastic oleofines - LDPE) good behaviour at low temperatures high diffusion resistance
Jointing at site
jointing only with semi-automatic Tricosal welding machines jointing straight lengths of same profile type only butt joints can be made on site
Physical properties
23
TC-Welding-Boy (semi-automatic)
PVC-P/Tricomer
Welding Equipment Semi-automatic Welding Equipment with clamping moulds, dependant on equipment and profiles. Available on rental basis against rental fees and deposit payment. Tools for hand welding: Axe-shaped welding tool Welding Tip Welding Tongue Hot Air Blower 200 W/250 W/300 W 50 W 125 W Round Nozzle, short Round Nozzle, long Flat Nozzle Quick Welding Nozzle, round Test equipment Spark Tester for testing the welded joint Welding Accessories: Welding Foil Welding Strip Tools: Special Knife Special Tongs for waterstop clips Accessoires for Installation: Waterstop Clip Type 1 Waterstop Round Clip Fixing Hanger for FIX-waterstops
Vulcanizing Unit
Elastomer (rubber)
Vulcanizing Equipment: with moulds, dependant on equipment and profiles. Available on rental basis against rental fees and deposit payment. Note: vulcanizing units for capping joints are not available for rent! Site jointing only by Tricosals technicians. Vulcanizing Accessories: Vulcanizing Solvent Adhesion Foil Strip Type 0 Strip Type 1 Bonding Agent for steel/rubber connections, including primer Talcum Plug
Waterstop Clips
Tools: Special Knife Roller Round Wire Brush Taping Rod Grinder Accessories: Waterstop Clip Type 2 Steel Connector
Type 1
Type 2
Round Clips
Steel Connector
Flanging Constructions
see page 17
24
Available Types: 1-13 Available Types: 1-13 Available Types: 1-11 Symmetric corner, type 12 - on request Angle corner, type 13 - on request Available Types: 1, 2, 3, 5
9. vertical edge 10. flat edge, cover plate external 11. flat edge, cover plate internal 12. symmetric corner 13. angle corner
Tricomer Elastomer
PE
6 7 8 9 1. flat cross 2. flat T 3. flat edge 4. vertical T 5. vertical edge 6./7. vertical cross 8. vertical T 10 11 12 13
Elastomer PE
16
17
18
19
The types shown (14 19) are only a selection of the possible composite types.
Waterstop Systems
One of our special services is the manufacture of waterstop systems, combining several numbers or types of junctions according to site requirements. They are pre-fabricated to such a degree that only a few butt welds are necessary on site. The total length of a system should not be more than 10-20 m, depending on the type of profile. Please contact us regarding the special terms and conditions for junctions and systems. The sample shown is a polygon with connectors.
25
Tricoplan
Total width a
DF DF DF DF
. . . .
. .* . .*
When ordering please specify the profile type and material type required (e.g. PE for polyethylene)
Tricoplan
Profiles
Total width a
For expansion joints DF 240/25 .... 240 110 4 DF 300/25 ....* 310 110 4 DF 320/25 .... 330 110 4 DF 400/25 ....* 400 110 4 For construction joints AF 240/25 .... 240 110 4 AF 300/25 ....* 310 110 4 AF 320/25 .... 330 110 4 AF 400/25 ....* 400 110 4 For construction joints with integrated injection channel AFI 600 600 270 4
30 30 30 30 30 30 30 30 35
4 4 6 6 4 4 6 6 6
When ordering please specify the profile type and material type required (e.g. PE for polyethylene) * with lateral welding flanges 55 mm wide
Tricoplan
Profiles
Total width
with lateral welding flanges 55 mm wide AF 60/15 .... 60 AF 80/25 .... 85 AF 155/25 .... 155 AF 140/25 .... 140 AF 200/25 .... 200 with extra wide welding flange AF 320 / MOD .... 330 capping joint profile with welding flange FF 14/3-10 .... 140 100
4 4 4 4 4 4 6
20 30 30 30 30 35 25
2 2 2 3 3 3 6
When ordering please specify the profile type and material type required (e.g. PE for polyethylene)
26
Tricoplan
Total width a FF 14/3-10 . . 140
When ordering please specify the profile type and material type required (see below).
Tricoplan
Total width a
Web thickness c 4
AF 320 MOD/ . .
330
When ordering please specify the profile type and material type required (see below).
To ensure a homogeneous and durable welding of the membrane fixing profile with the waterproofing membrane, the material of the profiles has to be adjusted to the membrane. The technique of jointing profiles with each other and with the membrane has to be specified in dependence of the material properties. In each case, please consult the technical department of Tricosal GmbH. The membrane fixing profiles described and shown above cannot be manufactured from each raw material (PVC-P or PE), due to specific material properties. In each case a verification and adjustment with the waterproofing membrane is required.
The following materials are available to match with the waterproofing membrane. Supplement to the nomenclature of the profiles: PVC-P/NB PVC-P/BV PVC-P/TU translucent PE (polyethylen modified) NB BV TU PE
The dimensions shown in the tables refer to profiles made of PE. In case of other raw materials variations are possible.
27
Save buildings due to G joints resisting fire G waterstops protected from excessive temperatures
Expansion joints in constructions using waterstops must retain their function even after a fire and thus its spreading, but it is also essential to limit the temperature strain of the waterstop. Only this will guarantee that the waterstop, and thus the joint, will retain its function during and after the fire. The Tricosal Fire Resisting System for Construction Joints offers this kind of protection. The Tricosal Brand-Ex-Profiles consist of foamed material free from asbestos and fibres, containing a specially developed ceramic impregnating agent will react in two stages. Security stage 1 The flexible seal is self-consistently turned into a ceramically compacted joint seal by the heat. Security stage 2 The joint is filled by expanding ingredients to prevent any unacceptable rise in temperature of the waterstop as well as burning through of the fire. The components offered can be used in any of the following combinations: To protect the joint and the waterstop: - Brand-Ex-Profile without additional sealing of the joint - Brand-Ex-Profile with pre-compressed waterstops as external seal. As hardly inflammable seal of the joint: - MKB-Inset Profiles (self-extinguishing type) A seal of the joint should be provided to protect the BrandEx-Profiles from mechanical damage. Should the construction be exposed to weathering or, e.g., be affected by thawing-salt smog, this additional sealing of the joint must be used.
Preferred applications: tunnels underground parking industrial constructions administrative buildings, hospitals pre-assembled constructions (also without waterstops)
28
Brand-Ex Profiles
Width of joint K
maximum temp. in K T 60 60
Distance in mm Total height H 100 150 Tricomer Elastomer D 200 250 D 150 200
16-23 16-23
*In case of a fire, maximum rise in temperature at the waterstop for a fixed period of time
Technical Data
delivery unit: colour: weight: TFB 90/20: TFB 180/20: 3 rolls of 4 m each in one carton 2 rolls of 4 m each in one carton
concrete grey TFB 90/20: 0,75 kg/m TFB 180/20 1,20 kg/m
Brand-Ex-Profiles are only made to order and can be stored for 6 months. The following details are required when ordering: duration of protection: width of joint: 90 min. (F 90) 180 min. (F 180) minimum and maximum values due to movements of the building (e.g., 16 to 23 mm)
Further information and notes for use can be taken from the Tricosal leaflet Waterproofing Manual.
width of joint K 20
width of profile B 17
hight of profile H 30
delivery unit
dark grey watertight under heavy rain in accordance with German Industrial Standard (DIN) 18055 pre-compressed waterstop tape 20 30 28 rolls of 20 m each
MKB 20
29
MARO
pipe collar
Inner- in mm up to * d
Width of collar in mm a 330 330 330 330 330 500 500 500 500
* The inner- of the collar is selected in dependence of the outer diameter of the pipes
Function
Waterproofing by anchoring ribs (labyrinth system), accommodation of movements by an expansion part. The collar is manufactured to size of a given pipe outer diameter and fixed with tightening steel straps. The anchoring ribs are embedded into concrete and provide a waterproofing effect, like externally placed waterstops. In the area of the expansion joint the pipes are interrupted; the joint is bridged with the expansion part and the spacers. Different movements of adjacent structural members are accommodated by the expansion part of the collar.
Components/Packing
Pipe collar made of Tricomer BV-quality, DIN 18541, complete with 2 (two) stainless-steel straps Note: The polystyrene protective packing between the ribs is for transportation only and has to be removed prior to the installation.
30
General Information
for all Products
Information/ Use
All details contained in this leaflet are product descriptions. They are general recommendations based on extensive research and practical experience but do not consider the actual application work. No indemnity may be claimed from the information given. If necessary, please contact our technical department for more information. If required for specific applications, additional tests can be carried out in our laboratory to supplement the standard tests and the normal material compatibility information.
Technical Changes
We reserve the right to alter either the form of the profiles or the material properties in case of new technical developments. The information and recommendations in our Waterproofing Manual, leaflets and quotations have to be considered. The standard dimensions shown in the tables are quoted in mm, unless no other information is given. The drawings shown are schematic and may differ from the actual installation on site. The waterstop drawings shown are examples for the profiles listed in the right hand columns. 1999: Tricosal GmbH, Illertissen All rights reserved. No part of this publication may be reproduced, translated or in any form photo-electronically transmitted without prior permission.
Dimensions
Drawings
Copyright
Edition Copies
31
Tricosal GmbH Von-Helmholtz-Strae 1 D - 89257 Illertissen Germany Phone: (+49) 73 03 / 180 - 0 Fax: (+49) 73 03 / 180 - 355 e-mail: tricosal@t-online.de BBZ AG Gewerbezentrum Rotfarb CH - 9213 Hauptwil Switzerland Phone: (+41) 71 / 422 - 1111 Fax: (+41) 71 / 422 - 5815 e-mail: bbz-ch@swissonline.ch BBZ USA, Inc. 100 Queen Street, Professional Center Southington, CT 06489 - 5031 Phone: 800 / 814 - 4489 Fax: 860 / 276 - 9832 e-mail: bbzusa@aol.com