Rosemount 8700 Series Magnetic Flowmeter Transmitter Configuration Data Sheet

Customer: Transmitter Model No.: 8732EST1A1NAM4Q4 Transmitter Tag No.: FE-3365/FIT-3365 Transmitter Tag (software): Sales Order Number: Line item: Unit number: Sales Person:

Process Information
Flow Rates:

Min: 45.00

Max: 120.00 Operating Pressure: 2.00 Operating Temperature: 22.00

m3/hr m3/hr bar-g C

Fluid Description: WATER Operating Density: 998.045 Specific Gravity:

kg/m3

Basic Configuration Options


LRV: URV: Damping: Descriptor: Message: Date (day/month/year): Security State: 0.000 120.000 2.0 m3/hr m3/hr seconds Special Volume Unit: Special Rate Unit: Conversion Factor: Base Volume Unit: Base Time Unit: Alarm Option: Rosemount High Totalizer 1 Unit Cubic meters Totalizer 2 Unit Totalizer 3 Unit

Off

Ident Number NOT USED

Advanced Configuration Options


Pulse Scaling: 1 Pulse=: Pulse Width: Coil Pulse Mode: Pulse Loop Power: Analog Loop Power: Local Display Language: Flow Rate Display: Totalizer 1 Display: Totalizer 2 Display: Totalizer 3 Display: Reverse Flow: m/s 5 Hz External Internal English Eng. Units and % Span Forward - Reverse Operational Mode: Signal Processing: No. of Samples: Max. % Limit: Time Limit: Low Flow Cutoff: Simulate: Burst Mode Output: Signal Selection: Multidrop/Network Address: Normal Off

0.04 NOT USED Disabled 0

Sec ft/s

Disabled

Digital Input/Digital Output


Digital I/O 1 Control: Digital Input 1 Mode: Digital Output 1 Mode: Digital Output 2 Mode: Flow Hysteresis: Flow High Limit 1: Flow Low Limit 1: Flow Limit 1 Mode: Flow Limit 1 Alert: Off Diagnostic Status Alert: Flow High Limit 2: Flow Low Limit 2: Flow Limit 2 Mode: Flow Limit 2 Alert: Off Totalizer Hysteresis: Totalizer High Limit: Totalizer Low Limit: Totalizer Limit Mode: Totalizer Limit Alert: Off m3/hr m3/hr

m3/hr m3/hr m3/hr

Cubic meters Cubic meters Cubic meters

Basic Diagnostics
Electronics Temperature: Empty Pipe Functionality: Trigger Level: Empty Pipe Counts: Off Off 100 5

Advanced Diagnostics (Requires DA1/D01 Option)


High Process Noise: Grounding Wiring: Electrode Coating: Electrode Coating limit 1: Electrode Coating limit 2: kohms kohms

Diagnostics Analog Alert

8714i Meter Verification Diagnostic (Requires DA2/D02 Option)


Empty Pipe: Flowing Full: Full, No Flow: Continuous Meter Verification:

Sensor (Flowtube) Information


Sensor Serial No.: Sensor Model No.: 8705TSA040C1W0NAB3Q4 Sensor Tag No.: FE-3307 Sensor Size: 040 Sensor Calibration No.: Electrode Material: Electrode Type: Flange Material: Flange Type: Liner Material: 316 SST Standard Carbon Steel ANSI 150 PTFE Teflon

This report is provided according to the terms and conditions of the Instrument Toolkit End-Use Customer License Agreement. Project Name: Version: 3.0 (Build173C) CMPC-PCD-2424 CLARIFICADOR Project Number: Printed: 001-20120402-000024 03-04-2012