Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Product Software Release

Product Name Version Number Release Number Compatible CPLD Version/Revision

Eternity PE 3S 11 2 Release-1 (Main application V11R2) V1R2 and onwards

Compatible PCB Version/Revision

138-006-01-02 and onwards

Microcontrollers N.A. Version/Revision (if applicable) File Name, File Size and MD5sum File Name Field build.txt EON48D_v4r5.mfb etpe_bri_dsp_v1r1.mfb etpe_ds1_dsp_v1r1.mfb etpe_dspimgldr_v1r2.o etpe_gsm_dsp_v1r1.mfb etpe_slave_app_v1r6.o etpe3s.sh etpe3s_cpu_dsp_boot1_v1r1.mfb etpe3s_cpu_dsp_boot2_v1r1.mfb etpe3s_dsp_app_v10r1.mfb etpe3s_mstr_app_v11r2.o ExIP_BuildInfo.txt extip_V05R13.tar.gz systemver PE3S_Kernels busybox dosfsck etpe_kernel_v1r8.img flash_eraseall hotplug.sh proftpd proftpd.conf usbplugnplay.sh Production Flash Image 1.23 MB 131 KB 1.29 MB 41.4 KB 1.40 KB 921 KB 2.35 KB 8.38 KB 8173BD2FA3FFCDE782C93B5D2B9E5447 0D8CCC09AA4D07D9E9B539499918E62F 3EB2A7197A25DF8A3D967D48D5F4A668 894B133552984479D61DCC9E7E621FAE 2C53B2CA31006B74F94DEB3DDC982D7E 0AC0C8AE161CC394D9A65BA9EEFF9930 78167A287FB44E86B96D2905F127F4C0 AD6BB42631BF07ADE9DDD1309431FC5B 24 bytes 94 KB 160 KB 163 KB 27.2 KB 152 KB 1.68 MB 20.6 KB 27.4 KB 32.8 KB 1.01 MB 11 MB 190 bytes 930 KB 17 bytes 15DBCBCFA425C0DD5A8DC432E78E0371 F11BF4ACFC8EBEE70231B4B1B95CF695 E712A0522A78916E76A7CBB4933F1964 C17A4CBB66CBF10054041632782D1F4D 7EF08EB8E1C0048EDA2474DAE3054E52 0DECB036876E9AFB31717F5294C6154F E03AE0C95E361E6AE08ADD9F657A3B95 82B89128C8C6198054175F3E44AB2C83 630A6513B758AD91AB85B5AC21CEC4A6 4C547D9E48AD4152C7278F2D99E93F8A BF6919226735A8EF64DD08E7624BEAD8 8A80D28FE006F0DD1D00373F98221A46 9493A5061C4C0BF9F91399A6C4F1B933 75C9B48FF2A05CA7C2B99973F7F0B863 6EB918E4ABD9F0832727D3B7E33E7648 File Size MD5Sum

______________________________________________________________________________________________ MATRIX COMSEC PVT. LTD. Page 1 of 3

Product Software Release

EtPE3S_Flash_Image_V11R2.bin

32MB

6bd4d05b0d2eac89c1ba737e892f7128

Date 30/09/13 a) Will this firmware up gradation affect the system configuration? b) Will the system automatically set to default No configuration? c) Give details of configuration changes after upgradation Debug Deactivated? N.A. Version/Revision updated in YES Reports? Version /Revision of SAD document to which this release Refer Release note of ME V11R2 complies to (Mention exceptions, if any) System Manual Version: Refer Eternity ME V11R2 Release Note Users Guide Version: Refer Eternity ME V11R2 Release Note Quick Start Version: Refer Eternity ME V11R2 Release Note Change required in Bonded YES Stock? Notes: Details of Modification Auto Kernel updatability support as per previous release:

Month: September Month: September Month: September

Note: Following three steps are for information regarding automatic kernel updatability. 1) The appropriate kernel will be updated automatically based on current kernel if needed. 2) While rebooting the system after Field upgrading, kindly make sure that power does not go and system is not powered off till dial tone comes on any port else the kernel will be corrupted and system will be non-functional. Changes Master Application: 1) Refer Release note of Eternity ME V11R2 Reminder for support team: New production boards with V10R12 will not be down-gradable as there is change in u-boot. Changes DSP Application: 1) FSK CLI Detection: Incoming FSK CLI was not detected at few customers site. This was happening after CLI validation is added for its different parameters. While doing these changes, the Message type checked was only MDMF (0x80). And at customer's site the message type received in incoming CLI was SDMF (0x04). So, SDMF message type is included in validation as correct type.

2) T1-E1: Problem: DTMF tone was not detected at one of the customers site. Analysis: DTMF tone duration length received was less than 20ms but at T1E1 port default DTMF tone detection
______________________________________________________________________________________________ MATRIX COMSEC PVT. LTD. Page 2 of 3

Product Software Release

duration was fixed to 20ms minimum. Solution: From this application, T1E1 port can detect DTMF tone of minimum 10ms duration and that duration parameters are made programmable 1. DTMF Detection Minimum ON Time 2. DTMF Detection Minimum OFF Time 3. DTMF Detection Minimum Level (dB)
Note: These changes work only with Master application V11R2 onwards only. SYSTEM Related:

Modification
Standby Mode for SLT Port: SLIC Lib V3R20 Used GSM Lib V2R24 used Quectel M95 Engine support added. SMS Server

SAD Revision / Field Issue #


0.140.3

Dependency
1) CPU DSP 2) SLIC library 3) Master application GSM Library Slave-layer application 1) Master application