28-12-2006
The TT-3616C is designed to be mounted on a flat surface anywhere inside a vessel and to be located up to 50 meters away from the TT-3026C mini-C Transceiver and up to 20 meters away from the TT-3606E Message Terminal.
The grounding wire delivered with the TT-3616C has a length of 1 meter and a wire cross section of 4mm2.
To help inserting wires into the terminals, a special tool is delivered as part of the accessory kit.
Power cable connections. Connect the positive supply wire to the terminal denoted DC+ and the negative supply wire to the terminal denoted DC-. The Remote On/Off terminal located next to DC- must be connected to DC- in order to turn on the unit. By combining this Remote On/Off with the similar signal on the TT-3606E Message Terminal and making the connection to DCvia a switch, then all equipment except the printer can be switch on and off by a simple low power switch.
Connecting the 20m or the 50m cable to the TT-3616C. In order to prepare the transceiver cable for mounting, start by removing 20 cm. of isolation.
Finally connect the individual wires to the 18 pole terminal block. It is labelled by wire colour. Connect the Transceiver cable as directed by these labels.
RS232 cable connection. Mount the RS232 cable supplied with the TT-3606E Message Terminal. An extended serial communication cable must not exceed 20 meters.
In order to prepare the cable for mounting, start by removing 12 cm. of isolation.
Pin 2 (GND)----------------------------------GND Pin 4 (RX ALARM IN)------------------I/O 2 (3616C) Pin 6 (TX ALARM IN)-------------------I/O 0 (3616C) Pin 7 (TT ALARM OUT)----------------I/O 4 (3616C) Pin 3 (IN/OUT 1)-------------------------I/O 1 (3616C) Pin 9 (VCC A IN)---------------------- +9V DC (3616C) Remember +24V DC at the Alarm Panel X1 Pin 6 and 7 from a power supply. The AP4365 starts beeping, if you bring the Sat-C into test mode via the 3606E.
An installation with three alert buttons. Note the jumper W1002, where the contact elements are horizontally aligned in order to enable an extra button on J1005.
An installation with four alert buttons. Note that the contact elements of both jumper W1001 and W1002 are horizontally aligned in order to enable extra buttons on both J1003 and J1005.
Enabling of the SSAS option. The SSAS functionality can be enabled and disabled by entering the SSAS option code. Remember there will NOT be light in the test button, before the SSAS option is enabled, and the system is rebooted
TT-3000E Troubleshooting
With the command ru l you will get the status of all connected devices and show their status.