Rotametros FVA 250
Rotametros FVA 250
Rotametros FVA 250
Fig. 2 Flow tube/scale angle ___________________________________________________________ Fig. 1 F VA 250 variable area flow meter ___________________________________________________________
___ Application
The VA 250 variable area flowmeters with a standard length of 250 mm (9.84 inch) and a completely metal design can be used to measure many different types of liquids and gases passing through closed piping. The robust design means that they can also be used in rough conditions. Different types of flanges, liners and float materials satisfy the requirements of the pharmaceutical and chemical industries. The measured value is displayed directly on the scale, and output via a switch contact or as a current output. The main applications for the VA 250 can be found in the following fields: Chemical industry Water Power generation and distribution.
___________________________________________________________
___
Classification according to PED 97/23/EG Order No. 7ME58207ME5821xAxxx-xxxx xBxxx-xxxx xCxxx-xxxx xDxxx-xxxx xExxx-xxxx Permissible media Category
___________________________________________________________
Gases and group 1 Gases and group 1 Gases and group 1 Gases and group 1 Gases and group 1
liquids of fluid liquids of fluid liquids of fluid liquids of fluid liquids of fluid
Flow Dimension for measured variables Rated operating conditions Mounting Ambient temperature
Hysteresis Ambient temperature F VA251 (inductive contact) Switching principle Connection Rated voltage Self-inductance Self-capacitance
Medium conditions Accuracy Temperature of medium Viscosity limits Qmax [m3/h] ! 0,1 > 0,1 to 0,5 > 0,5 to 3 > 3 to 10 > 10 to 25 > 25 to 50 > 50 to 100 > 100 Design Flanges Material Fitting Float Wetted parts materials Degree of protection (display unit) Qmax [USgpm] ! 0,44 > 0,44 to 2,2 > 2,2 to 13 > 13 to 44 > 44 to 110 > 110 to 220 > 220 to 440 > 440
Inductive contact, single contact; twin contact as option PG 11 10..28V DC 500H 80 nF -20 to +70C (-4 to 158F)
to to to to to to to
Ambient temperature without EX-protection F Va 252 (electric remote sensor, current output) Principle Connection Power supply Self-capacitance Short-circuit current Output 2-wire system 3-and 4-wire systems Load Ambient temperature without EX-protection
Rotation angle transmitter 2-, 3- or 4-wire system DC 12 to 30V <10 nF max. 160mA 4 to 20mA 0 to 20mA max. 900 at 30V
DIN, ANSI Stainless steel 1.4571/ 316Ti Stainless steel 1.4571/ 316Ti, Hastelloy, Titanium, Aluminium Stainless steel 1.4571/316Ti, PTFE, C22.8, Hastelloy depending on version IP65
C22.8 mat.No. mat.No.1.4571/ mat.No.1.4571/ 1.4571/316Ti 316Ti 316Ti mat.No.1.4571/ mat.No.1.4571/ mat.No.1.4571/ 316Ti 316Ti 316Ti C22.8
PTFE
mat.No.1.4571/316Ti
Flange
mat.No.1.4571/ mat.No.1.4571/ mat.No. 1.4571/ mat.No.1.4571/316Ti with PTFE liner 316Ti 316Ti 316Ti with PTFE liner Hastelloy PTFE
Float/flow mat.No.1.4571/ mat.No.1.4571/ mat.No.1.4571/ tube 316Ti 316Ti 316Ti Max.tem125C (257F) 125C (257F) 125C (257F) perature of optional 300C optional 300C optional 160C medium (572F) (572F) (320F) Nominal pressure DN15 to DN80/ DN15 to DN80/ DN15 to DN25 (1/2 to 3 inch): (1/2 to 3 inch): (1/2 to 1 inch): PN40 (580 psi) PN40 (580 psi) PN40 (580 psi) DN100 (4 inch): DN100 (4 inch): PN16 (232 psi) PN16 (232 psi)
50C (122F)
Connection DIN2501
DN 15 DN 25 DN 50 DN 80 DN 100
Full-scale value Flow tube l/h 16 25 40 63 100 160 250 400 630 1.000 1.600 2.500 4.000 6.300 10.000 16.000 20.000 25.000 40.000 50.000 63.000 100.000 (USgpm) (0,07) (0,11) (0,18) (0,28) (0,44) (0,7) (1,1) (1,76) (2,77) (4,4) (7,0) (11,0) (17,6) (27,7) (44) (70) (88) (110) (176) (220) (277) (440) A B C D E F G H J K L M N P Q R S T U V W X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x DN15-25 (1/2-1 inch) 250 (1,1) DN15-25 (1/2-1 inch) 400 (1,76) DN15-25 (1/2-1 inch) 630 (2,77) DN25 (1 inch) 1.000 (4,4) DN25 (1 inch) 1.600 (7,0) DN25 (1 inch) 2.500 (11,0) DN50 (2 inch) 4.000 (17,6) DN50 (2 inch) 6.300 (27,7) DN50 (2 inch) 10.000 (44)
Nominal diameter
l/h (Usgpm)
25.000 (110)
1)
For the FF-P version, only the measuring ranges of the listed nominal diameters are possible Pressure loss mbar (psi) 60 (0,87) 60 (0,87) 90 (1,3) 160 (2,3) 240 (3,5)
Measuring ranges and pressure losses for liquids (density "= 1kg/l (62,43 lb/cu.ft) and viscosity 1mPa.s(cp)) with standard scales. The dynamic range is always 1:10.
mat.No.1.4571/316Ti
Flange
mat.No.1.4571/ mat.No.1.4571/ mat.No.1.4571/316Ti with PTFE liner 316Ti 316Ti with PTFE liner mat.No.1.4571/ 316Ti 125C (257F) optional 160C (320F) DN15 to DN25 (1/2 to 1 inch) PN40 (580 psi) Titanium/ Hastelloy 80C (176F) PN16 (232 psi) PTFE
Float/flow tube
Titanium mat.No.1.4571/ 316Ti 125C (257F) optional 300C (572F) DN15 to DN80/ (1/2 to 3 inch): PN40 (580 psi) DN100 (4 inch): PN16 (232 psi)
Max. tempe125C (257F) rature of optional 300C (572F) medium Nominal pressure DN15 to DN80/ (1/2 to 3 inch): PN40 (580 psi) DN100 (4 inch): PN16 (232 psi)
50C (122F)
Connection DIN2501
DN 15 DN 25 DN 50 DN 80 DN 100
Full-scale value Flow tube m/h (USgpm) 0,5 1,0 1,6 2,5 4,0 12,0 16,0 25,0 25,0 40,0 63,0 100,0 100,0 160,0 250,0 400,0 400,0 630,0 (0.294) (0.589) (0.942) (1.47) (2.35) (7.06) (9.42) (14.71) (14.71) (23.54) (37.08) (58.86) (58.86) (94.17) (147.1) (235.4) (235.4) (370.8) A B C D E F G H H J K L L M N P P Q X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
Minimum inlet pressure mbar (psi) 500 (7,25) 100 (1,45) 100 (1,45) 100 (1,45) 100 (1,45)
Measuring ranges and pressure losses for air (pabs= 1,013 bar (14,69 psi) at T=20C (68F)). The dynamic range is 1:10 for each flow tube.
see left Heating/cooling sheath Without (standard) H/K with flange connection H/K without flange connection Display With local display (standard) With magnet spring contact F VA 251 With inductive contact F VA 251 With electric remote sensor F VA 252 (0 bis 20mA) With electric remote sensor F VA 252 (4 bis 20mA)
Contact function No contact (standard) For magnet spring contact (twin contact): Close on upward or downward violation of limit Open on upward or downward violation of limit Close on downward violation, open on upward violation of limit Open on downward violation, close on upward violation of limit For inductive contacts: Open on downward violation of limit Close on downward violation of limit Close on upward or downward violation of limit Open on upward or downward violation of limit Close on downward violation, open on upward violation of limit Open on downward violation, close on upward violation of limit
A B C D E
J K L M N P
A B C D E F G H J K L M N P Q R S T U V W X 1 2 9 0 1 2
L1Y
Calibration Standard calibration Without calibration certificate 0 With calibration certificate 1 Special calibration 9 R1Y (1,6% accuracy) Further designs Order code Please add "-Z" to Order No. and specify Order code(s) Acceptance test B to C12 DIN50049, Section. 3.1 and EN10204 Measured medium, specify in Y01 plain text (always required): Medium, measuring range, dimension, density, density dimension, viscosity, viscosity dimension, operating temperature, operating pressure Silicone-free version Y04 Water as measured medium Y05 Viscosity: 1mPas (cp) Density: 1 kg/l (62,43 lb/cu.ft) Stainless steel tag plate Y17 Special version: Y99 specify in plain text Note:See table on page 3 for possible combinations of nominal diameters and flow tube. Teletransmitters and contacts cannot be ordered simultaneously.
Order code -
Heating/cooling sheath Without (standard) H/C with flange connection H/C without flange connection Display With local display (standard) With magnetic spring contact F VA 251 With inductive contact F VA 251 With electric remote sensor F VA 252 (0 to 20mA) With electric remote sensor F VA 252 (4 to 20mA) Contact function No contact (standard) For magnet spring contacts: Close on upward or downward violation of limit Open on upward or downward violation of limit Close on downward violation, open on upward violation of limit Open on downward violation, close on upward violation of limit For inductive contacts: Open on downward violation of limit Close on downward violation of limit Close on upward or downward violation of limit Open on upward or downward violation of limit Close on downward violation, open on upward violation of Open on downward violation, close on upward violation of limit
0 2 3 A B C D E
A D E G H
A B C D E
J K L M N P
A B C D E F G H R J K L M N P 1 2 9
L1Y
0 1 2
Calibration Standard calibration Without calibration certificate 0 With calibration certificate 1 Special calibration 9 R1Y (1,6% accuracy) Further designs Order code Please add "-Z" to Order No. and specify Order code(s) Acceptance test B to C12 DIN50049, Section 3.1 and EN10204 Measured medium, specify in Y01 plain text (always required) Medium, measuring range, dimension, density, density dimension, viscosity, viscosity dimension, operating temperature, operating pressure Silicone-free version Y04 Stainless steel tag plate Y17 Special version: Y99 specify in plain text Note: See table on page 4 for possible combinations of nominal diameters and flow tube. Teletransmitter and contacts cannot be ordered simultaneously.