INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING International Journal of & Electrical Engineering and(IJEET) Technology (IJEET), ISSN 0976 TECHNOLOGY

6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

ISSN 0976 6545(Print) ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), pp. 171-183 IAEME: www.iaeme.com/ijeet.asp Journal Impact Factor (2012): 3.2031 (Calculated by GISI) www.jifactor.com

IJEET
IAEME

DESIGN OF HIGH EFFICIENCY PELTON TURBINE FOR MICROHYDROPOWER PLANT


Bilal Abdullah Nasir1
1

Hawijah Technical Institute, Kirkuk, Iraq

ABSTRACT The Pelton turbine was performed in high head and low water flow, in establishment of micro-hydro electric power plant, due to its simple construction and ease of manufacturing. To obtain a Pelton hydraulic turbine with maximum efficiency during various operating conditions, the turbine parameters must be included in the design procedure. In this paper all design parameters were calculated at maximum efficiency. These parameters included turbine power, turbine torque, runner diameter, runner length, runner speed, bucket dimensions, number of buckets, nozzle dimension and turbine specific speed. Keywords:Pelton turbine, maximum efficiency, designparameters,micro-hydro power plant. 1. INTRODUCTION Hydraulic turbine can be defined as a rotary machine, which uses the potential and kinetic energy of water and converts it into useful mechanical energy. According to the way of energy transfer, there are two types of hydraulic turbines namely impulse turbines and reaction turbines. In impulse turbines water coming out of the nozzle at the end of the penstock is made to strike a series of buckets fitted on the periphery of the runner. The runner revolves freely in air and the casing is not important in impulse turbine. In a reaction turbine, water enters all around the periphery of runner and the runner remains full of water every time. The water leaves from the runner is discharged into the tailrace with a different pressure. Therefor casing is necessary for reaction turbines [1].Pelton turbine is an impulse turbine. The runner of the Pelton turbine consists of double hemispherical cups fitted on its periphery as shown in figure (1).

171

International Journal of Electrical Engineering Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, JanuaryJanuary February (2013), IAEME

Figure (1) The runner ofthePelton turbine The jet strikes these cups (buckets) at the central dividing edge of the front edge. The central dividing edge is also called as splitter. The water jet strikes edge of the splitter symmetrically and equally distributed into the two halves of hemispherical bucket. Theoretically, , if the buckets are exactly hemispherical, it will deflect the jet through 180. Then the velocity of the water jet leaving the bucket would be opposite in direction to the velocity of jet entering. Practically, this can not be achieved because the jet le leaving the bucket strikes the back of succeeding bucket and the overall efficiency would decrease. In practice, the angular deflection of the jet in the bucket is limited to about 165170. The amount of water discharges from the nozzle is regulated by a needle needle valve provided inside the nozzle as shown in figure (2).

Figure (2) The nozzle and deflector of the Pelton turbine: (a) the nozzle spear and deflector. (b) The nozzle components. A deflector is used to control the turbine speed. One or more water jets (nozzles) can be provided with the Pelton turbine depending on the water flow rate and the nozzle capacity.
172

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

The Pelton turbines have been given increasing interest by the research community within multiple fields. This is due to the increasing demand for energy on a global basis in addition to the growing focus on meeting the increasing demand by utilizing renewable energy resources. An increase in efficiency in the order 0.1 % would lead to large increase in electrical power production. Innovation within energy business is kept a close corporate secret and all research done on a turbine designed by commercial companies is confidential. Thus the deferent research communities have no common practical case with which they can cooperate within their distinctive fields [2]. The literature on Pelton turbine design available is scarce at best due to the competitive nature of the industry and the resulting secrecy surrounding design methods and innovations. In the last decade a lot of papers about numerical and experimental analysis and design of Pelton turbines have been published. A water jet from Pelton turbine injector was analyzed experimentally and numerically by Barkinson in reference [3]. The influence of jet velocity and jet quality on turbine efficiency were investigated by Vesely and Staubli in references [4,5]. A bucket simulation using three adjacent buckets was shown by Mack and Moser in reference [6]. Unsteady analysis of a Pelton runner with mechanical simulation was presented by Parkinson in reference [7]. A numerical analysis of water flow in a two jets Pelton turbine with horizontal axis was presented by Jost in reference [8]. A modification in the bucket design of Pelton turbine is suggested by SurajYadav in reference [9] to increase the efficiency of the Pelton turbine. The effect of runner to jet speed ratio on the Pelton turbine efficiency is tested experimentally by Bryan in reference [10]. In this paper a complete design procedure of a Pelton turbine, based on analytical and empirical calculation of the turbine parameters. The design steps was presented by Matlab Simulink computer program. The designed Pelton turbine was used in micro-hydro electric power plant to operate at maximum efficiency. 2. DESIGN STEPS OF THE PELTON TURBINE The design procedure of the Pelton turbine which is used in micro-hydro power generation can be systematic as follow: 1. Preparing the site data of power plant This involves the calculations and measuring the net head and the water flow rate. a. Calculation of the net head (Hn): (1)

Where Hg = the gross head which is the vertical distance between water surface level at the intake and at the turbine. Htl = total head losses due to the open channel, trash rack, intake, penstock and gate or valve. These losses approximately equal to 6% of gross head. b. Calculation of the water flow rate (Q): The water flow rate can be calculated by measuring the river or stream flow velocity (Vr) in (m.s-1) and its cross-sectional area (Ar) in (m2), then:

(2)
173

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

2. Calculation of the turbine input power (Pti) The electrical input power to the turbine in (Watt) can be calculated as: 3. Calculation of the turbine speed (N)

(3)

The correlation between the specific speed (Ns) and the net head (Hn) is given for the Pelton turbine as [11]: . 85.49 (4) Where nj = number of turbine nozzles (jets), and can be calculated as: Where Qt = water flow capacity of each nozzle (m3.s-1). Then the turbine speed in (r.p.m) can be calculated as [11]: (5)

4. Calculation of the runner circle diameter (Dr) The water jet through nozzle has a velocity (Vj) in (m.s-1) can be calculated as [11]: (m.s-1) 2

(6)

(7)

The runner tangential velocity (Vtr) in (m.s-1) can be calculated as: (m.s-1) 60 Also the runner tangential velocity can be given as [11]:

(8)

(m.s-1)

(9)

Where x = ratio of runner tangential velocity to nozzle or jet velocity.

From equations (8) and (9): 60

(10)

At maximum efficiency the ratio of (x) between (0.46) to (0.47). Then the runner diameter at maximum efficiency can be calculated from equations (7) and (10) as: 38.6 (11)
174

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

The required diameter must be greater than this calculated value due to inconsistencies in the manufacture of the buckets and the need to have a minimum distance of safety between the nozzle and the Pelton runner. If the turbine is free to rotate under no-load speed (run-away speed), the runner tangential speed should be equal to the jet speed as:


Or

2 60

The run-away speed (Nr) is independent on the water flow rate. 5. Calculation of nozzle dimensions [11]: The water flow rate through each nozzle (Qn) can be calculated as: (m3.s-1)

60

(r.p.m)

(12)

(13)

The nozzle area (Aj) can be calculated as: (m2) 4

(14)

Then from equations (13) and (14) the nozzle diameter (Dj) can be calculated as: 4 (m) The nozzle length can be calculated as [11]: (m) tan

(15)

(16) (17)

(m)

The nozzle exits have to be located as close to the Pelton runner as possible to prevent the jet from diverging the designed diameter. The distance between the nozzle and runner should be 5% of the runner circle diameter, plus an extra (3) mm clearance to account for emergency deflectors as:

0.05

(m)

(18)

175

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

The distance between nozzle and bucket taking into account the minimum clearance between the nozzle and buckets was given as:

The required distance was bigger than the calculated above, due to inconsistencies in the manufacture of buckets and the need to have a minimum distance of safety between the nozzle and Pelton runner. 6. Calculation of bucket dimensions [11]

0.625

(m)

(19)

3.4 3

The bucket axial width can be calculated as: (m) (20)

The bucket radial length can be calculated as: (m) (21)

The bucket depth can be calculated as:

1.2

(m)

(22)

The number of buckets in each runner must be determined so that no water particle was lost while minimizing the risks of detrimental interactions between the out flowing water particles and adjacent buckets. It can be calculated as: 15 2 (23) The length of the moment arm of bucket can be calculated as:

0.195

(m)

(24)

The runner size was determined by its diameter, and its shaper was determined by the number of buckets. The runner shaft was sized to mount directly on the generator shaft. The flinger seal was also necessary to seal the whole through which the generator shaft enters the turbine box. The radius of bucket center of mass to center of runner was given as:

0.47

(m)

(25)

The bucket volume was given as:


0.0063

(m3)

(26)

176

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

The mass of bucket can be calculated as:

(Kg)

(27)

7. Penstock design [11] The penstock was the piping that brings the water from the river or stream to the point where it begins to be directed to the turbine. Penstock material was made of high pressure such as PVC, chosen for its availability, affordability and low friction loss characteristics. The PVC was susceptible to mechanical damage from ultraviolet radiation. If the piping was weakened in any way, due to the high pressure in the penstock in any surge event, failure was a definite possibility. To prevent this, the PVC piping would be founded in concrete along its entire length. At the bottom of penstock, before the entrance to the turbine house, a valve would be installed. This valve would allow the penstock to be emptied for turbine maintenance. The thickness of penstock was chosen by determining the potential water hummer effect. A water hummer effect was a surge pressure that occurs when the nozzles in turbine become plugged and the flow in penstock was suddenly stopped. The thickness of penstock (tb) can be calculated by the following relations;

508 1.2 10 400 2.69 .

(m) (m)

(28) (29)

The surge pressure (Hs) in (m) can be calculated as:

(m)

(30)

(m.s-1)

(31)

(m.s-1)

(32)

The safety factor to mitigate the water hummer effect in the design of micro-hydro electric power plant was given as [13, 14]: . 2.5 (33) 5 10

(m)

(34)

177

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

8. Deflector design [15, 16] An emergency deflector system must be installed to protect the generator in case a load circuit failure, and the generator rotates at over speed. The force in each deflector can be calculated as: (Newton) (35)

The required force in each deflector was given as: (Newton) (36)

The torque acting on the deflector arm was given as: (N.m) (37)

The required torque acting on the deflector arm was given as: (N.m) (38)

9. Calculation of maximum turbine efficiency [12] The turbine efficiency generally affected by three factors: i.) Hydraulic losses or power losses those occur due to flow irregularity within the bucket. ii.)Windage losses which occur because of resistance in the air to the moving bucket. iii.) Mechanical losses in the system used to transmit the power from the turbine to the generator. If the turbine was mounted directly to the generator, there were no mechanical losses in the turbine. The input power to the turbine can be calculated as: (W) 2

(39)

The power output developed by the turbine was given as:

1 cos 2 1 cos

(W)

(40)

Then the turbine hydraulic efficiency can be calculated as:

(41)

180 160 170

(42)

178

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

0
Or 0.5

For maximum hydraulic turbine efficiency:

(43)

Then the maximum hydraulic efficiency was given as:

1 cos 2

(44)

The turbine windage efficiency was given as:

(45)

Then the total turbine efficiency was given as:

(46)

If the turbine was mounted directly to the generator the mechanical losses can be neglected and the mechanical efficiency (tm) equal to unity. The torque developed by the turbine can be calculated as:

(N.m)

(47)

3. RESULTS The design calculations of the Pelton turbine were implemented by a Matlab Simulink computer program. Table (1) shows the design parameters of the Pelton turbine with constant flow rate (Q = 0.1 m3.s-1) and variable gross head of the plant site (Hg= 50 140 m), while table (2) shows the same turbine parameters at constant head (Hg = 50, 60 m) with variable water flow rate (Q = 0.1 0.4 m3.s-1) of the site. Figure (3) shows the variation of runner to nozzle diameter ratio with specific speed at different values of water flow rate, while figure (4) shows the variation of the same ratio with the nozzle length. From these results, the turbine maximum efficiency was found to be 97% constant. In case of variable head, all the design parameters were varied with head except of number of runner buckets and runner diameter, while in a variable flow rate all the design parameters were constant except of turbine power, specific speed and nozzle length.
179

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME
Dr/Dj Runner/Nozzle Diameter Ratio 10 9.5 9 8.5 8 7.5 7 6.5 6 5.5 5 20 30 40 50 Specific Speed 60 70 80 Ns Q=0.1m /s
3

Q=0.2m /s

Q=0.3m /s

Q=0.4m /s

Figure (3) Variation of runner to nozzle diameter ratio with specific speed at different values of water flow rate.
Dr/Dj Runner/Nozzle Diameter Ratio 10 9.5 9 8.5 8 7.5 7 6.5 6 5.5 5 180 200 220 240 Nozzle Length 260 280 300 Ln (mm) Q=0.4 m /s Q=0.3 m /s
3 3

Q=0.2 m /s

Q=0.1 m /s

Figure (4)Variation of runner to nozzle diameter ratio with nozzle length at different values of water flow rate. Table (1) design parameters of the Pelton turbine at maximum efficiency and constant flow rate (Qt =0. 1 m3.s-1) Pto t Tt N Dj Vtr Vj Ln Hg (m) Ns Dr(m) nb (Kw) (%) (N.m) (r.p.m) (m) (m) (m) (m) 50 43 96.9 660 620 33.5 0.43 0.065 13.9 29.8 0.27 19 60 51.5 96.9 722 680 32 0.43 0.062 15.2 32.5 0.26 19 70 60 96.9 779 735 31 0.43 0.060 16.4 35.2 0.25 19 80 68.5 96.9 832 787 30 0.43 0.058 17.5 37.5 0.25 19 90 77.2 96.9 882 835 29 0.43 0.056 18.6 40 0.24 19 100 85.8 96.9 930 881 28.3 0.43 0.055 19.6 42 0.24 19 110 94.3 96.9 974 925 27.7 0.42 0.053 20.6 44 0.24 19 120 103 96.9 1016 967 27 0.42 0.052 21.5 46 0.233 19 130 111.5 96.9 1057 1007 26.6 0.42 0.051 22.4 48 0.230 19 140 120 96.9 1097 1045 26 0.42 0.050 23.2 50 0.228 19

180

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

Table (2) design parameters of the Pelton turbine at maximum efficiency and constant gross head Hg(m) Qt (m3.s-1)
0.1 0.2 0.3 0.4 0.1 0.2 0.3 0.4

Pto Tt (Kw) (N.m)


43 85.8 129 171.5 51.5 103 154.4 206 660 1320 1980 2640 722 1444 2167 2889

t (%)
96.9 96.9 96.9 96.9 96.9 96.9 96.9 96.9

N (r.p.m)
620 620 620 620 680 680 680 680

Ns
33.5 47.4 58 67.1 32 45.4 55.6 64.2

Dr(m)
0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43

Dj (m)
0.065 0.065 0.065 0.065 0.062 0.062 0.062 0.062

Vtr (m)
13.9 13.9 13.9 13.9 15.2 15.2 15.2 15.2

Vj (m)
29.8 29.8 29.8 29.8 32.5 32.6 32.6 32.6

Ln (m)
0.270 0.240 0.220 0.208 0.250 0.230 0.210 0.202

nb
19 19 19 19 19 19 19 19

(50)

(60)

4. CONCLUSIONS The Pelton turbine is suitable for installing small hydro-electric power plants in case of high head and low water flow rate. A complete design of such turbines has been presented in this paper based on theoretical analysis and some empirical relations. The maximum turbine efficiency was found to be 97% constant for different values of head and water flow rate. The complete design parameters such as turbine power, turbine torque, turbine speed, runner dimensions andnozzle dimensionsare determined at maximum turbine efficiency. Nomenclature

Ab Aj Ap Ar Bd Bl Bw Cn Dj Dpn Dpt Dr Dt Fc Fd Fdr g Hg Hn Hs Ht Htl Kd Kwm Lab Ln

Peripheral area of penstock (m2) Jet or nozzle cross-sectional area (m2) penstock cross-sectional area (m2) River or steam cross-sectional area (m2) Bucket depth (m) Bucket radial length (m) Bucket axial width (m) Nozzle (jet) discharge coefficient ( 0.98) Jet or nozzle diameter (m) Diameter of penstock connected to the nozzle (m) Diameter of penstock connected to the turbine (m) Runner (wheel) circle diameter (m) Deflector thickness (m) Friction factor acted upon by bearings (1.2) Deflector force (N) Required deflector force (N) Gravity acceleration constant (9.81 m.s-2) Gross head (m) Net head (m) Surge head (m) Total head (m) Total head loss (m) Drag coefficient Bulk water modulus (2.1*109 N.m-2) Length of bucket moment arm (m) Nozzle length (m) 181

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

Greek symbols Nozzle tapper angle (degrees) Bucket roughness coefficient ( 0.98) Deflection angle between bucket and jet (160170) Air density (1.23 Kg.m-3) a Density of bucket material (Kg.m-3) m Water density (1000 Kg.m-3) w Runner velocity (radian.sec-1) Runner run-away velocity (radian.sec-1) r Total turbine efficiency t Turbine hydraulic efficiency th Turbine mechanical efficiency tm Turbine windage efficiency tw
182

Lpt Mb Mp nb nj np N Nr Ns Pti Pto Qn Qt Rbr Rd Rr S.F tp tpe tsp Td Tdr Tt Vb Vj Vr Vtr Vw x Xnb Xnr V

Length of penstock between intake and turbine (m) Mass of bucket (Kg) Modulus of penstock material (for PVC = 2.8*109 N.m-2) Number of buckets Number of turbine nozzles Manning factor of penstock Turbine (runner) speed (r.p.m) Turbine run-away speed (r.p.m) Turbine specific speed Turbine input power (watt) Turbine output power (watt) Nozzle flow rate (m3.s-1) turbine flow rate (m3.s-1) Radius of bucket center of mass to runner center (m) Radius of deflector arm (m) Radius of runner (m) Safety factor to prevent water hummer effect (> 2.5) Thickness of penstock (m) Effective thickness of penstock (m) Tensile strength of penstock material (N.m-2) Deflector torque (N.m) Required deflector torque (N.m) turbine torque (N.m) Volume of bucket (m3) Water jet velocity (m.s-1) River velocity (m.s-1) Runner tangential velocity (m.s-1) Pressure wave velocity (m.s-1) Ratio of runner tangential velocity to jet velocity Distance between bucket and nozzle (m) Distance between nozzle and runner (m) Change in velocity of penstock (m.s-1)

International Journal of Electrical Engineering and Technology (IJEET), ISSN 0976 6545(Print), ISSN 0976 6553(Online) Volume 4, Issue 1, January- February (2013), IAEME

REFERENCES [1]Atthanayake, I. U.: "Analytical study on flow through a Pelton turbine bucket using boundary layer theory", International Journal of Engineering and Technology (IJET), Vol. 9, No. 9, pp. 241-245, 2009. [2]Solimslie, B. W. and Dahlhaug, O. G.: "A reference Pelton turbine design", 6th, IAHR Symposium on Hydraulic Machinery and Systems, IOP Publishing, IOP Conf. Series: Earth and Environmental Science, 15, 2012. [3] Parkinson, E. and et al.: "Experimental and numerical investigation of free jet flow at a model nozzle of a Pelton turbine", Proceeding of the XXI IAHR Symposium on Hydro Machines and Systems, Switzerland, 2002. [4]Vesely, J. and Pochyly, F.: "Stability of the flow through Pelton turbine nozzles", Hydro2003, Dubrovnik, Croatia, 2003. [5]Staubli, T. and et al.: "Jet quality and Pelton efficiency", Proceeding of Hydro-2009, Lyon, France,2009. [6] Mack, R. and Moser, W.: "Numerical investigation of the flow in a Pelton turbine", Proceeding of the XXI IAHR Symposium on Hydro Machines and Systems, Switzerland, 2002. [7] Parkinson, E. and et al.: "Unsteady analysis of a Pelton runner with flow and mechanical simulations", Hydro-2005, Beljak, Austria, 2005. [8]Jost, D. and et al.: "Numerical prediction of Pelton turbine efficiency", 25th, IAHR Symposium on Hydraulic Machinery and Systems, IOP Conf. 12, 2010. [9]SurajYadav: "Some aspects of performance improvement of Pelton wheel turbine with reengineered blade and auxiliary attachments", International journal of Scientific and Engineering Research, Vol. 2, No. 9, September, pp. 1-4, 2011. [10] Bryan, R. C. and Sharp, K. V.: "Impulse turbine performance characteristics and their impact on Pico-hydro installation", Renewable Energy Journal, Elsevier, Vol. 50, pp. 959964, 2013. [11] Thake, J.: "The micro-hydro Pelton turbine manual, design, manufacture and installation for small-scale hydro power", ITDG Publishing, UK, 2000. [12] Fluid-machinery, chapter-2, Pelton turbine. Available from: htt:// Ptumech. Loremate.com / fluid-machinery / node / 12 / [accessed 12 / 1 / 2013]. [13] Harvey, A. and et al.: "Micro-hydro design manual", ITDG Publishing, UK, 2005 [14] Comunidad Nueva Alianza: "Micro-hydro electric design", Engineering Design Document, Producing by Xelateco, Endorsed by AIDG, Guatemala, July, 2006. [15] Carvill, J.: "Mechanical engineers data handbook", Butterworth-Heinmann, 1993. [16] Johnson, R. M. and et al.: "Pelton turbine deflector over speed control for a small power system", IEEE Transactions on Power Systems, Vol. 19, No. 2, pp. 1032-1037, 2004.

183