Professional Documents
Culture Documents
Interfases de Comunicacion PLC Multimarca
Interfases de Comunicacion PLC Multimarca
Interfases de Comunicacion PLC Multimarca
CONTENTS
1. Abstract................................ Abstract............................................................ ............................................................ 1.1. 1.2. Touch Screen Communication Interface Feature .................. Communication Interface Protocol .............................
Serial Interface(RS-232C) ....................................... Serial Interface(RS-422/485) ....................................
1.2.1. 1.2.2.
1.3.
2. Serial Master Communication Type................................ Type..................................... ..................................... 2.1. LG MasterMaster-K Series................................ Series ......................................... .........................................
Master-K Serial Interface ..................................... Master-K CPU Direct Interface ................................. Available Address List ........................................
2.2.
2.3.
2.4.
2.4.1. 2.4.2.
2.5.
2.6.
2.6.1. 2.6.2.
2.7.
2.8.
2.8.1. 2.8.2.
2.9.
2.9.1. 2.9.2.
2.10.
2.11.
2.12.
2.12.1. 2.12.2.
2.13.
2.13.1. 2.13.2.
2.14.
2.14.1. 2.14.2.
2.15.
2.16.
2.16.1. 2.16.2.
3. Serial Slave Communication Protocol ................................. ................................. 129 3.1. SLAVE Protocol Description Description .................................. .................................. 130
READ Command ................................................... 131 Response Command(ACK) for READ ................................. 131 Write Command .................................................. 132 Response Command(ACK) for WRITE ................................ 132
Cable Diagram .............................................. .............................................. 133 Touch Screen Setup................................ Setup .......................................... .......................................... 133 Communication Programming Example ........................... 134
1. Abstract
1.1. Touch Screen Communication Interface Feature
Touch Screen has data indication function and operating function replacing operation panel including complex switch buttons and indication lamps, and also have many kinds of communication interface to external controllers for CIM configuration. Communication interface features of Touch Screen are as follows. Support standard serial interface RS-232C/422/485. Support communication master function to read and write external controllers memory data by using controllers fixed communication protocol through standard serial interface. And also provide Slave Protocol for serial interface to embedded system and Personal computer.
Contents
Direction
Contents
Receive Data Send Data Data Terminal Ready Signal Ground Data Set Ready Send Request Signal Send Enable Signal
4 5 6 7 8 9
Please refer transmission part of manual for how to connect and download between PC and Touch Screen.
Controller
Type
Connection Module
Ref.
Option Module CPU Direct CPU Direct CPU Direct A0J2C214 CPU Direct AJ71C24-S8 CPU Direct A1SJ71C24-R2 CPU Direct A1SJ71UC24-R2 CPU Direct AJ71UC24 CPU Direct AJ71UC24 CPU Direct AJ71UC24 AJ71QC24 CPU Direct FX2N-232-BD
Serial(RS-485) Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial
QnA
FX
G3L-CUEA CPU Direct G7L-CUEB CPU Direct K7F-CUEA CPU Direct K4F-CUEA CPU Direct K3F-CU2A CPU Direct G7LCUEB G7LCUEC CPU Direct
Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial Serial (RS-422) Serial (RS-232C) Serial (RS-232C/ RS-422) Serial (RS-232C) Serial (RS-422) Serial Serial Serial Serial Serial Serial
80S F80H,F120H, Micrex-F F120S,F140S, F150S C200H/C200HS C500/C1000H/ OMRON C2000H/C500F C50/C120/C500/C20 0H/C1000H/C2000H/ C120F/C500F/CS1 FARA-N70/700 FARA
FFU120B, FFK120A C200H-LK202-V1 C200H-LK201-V1 C500-LK201-V1/ C500-LK203 C120-LK201-V1 C120-LK202-V1 CCU CPU Direct
FARA-N70/700PLUS CPU Direct AB Modicon SLC500[5/03,04] PLC-5 884/984 SPC-10 SPC-24S SPC SPC-100 SPC-120S SPC-300 CPU Direct CPU Direct CPU Direct Modbus
Serial
S7-200PPI (CPU212/214) S7-MPI Siemens S7-300 S7-400 GE FANUC 90-30 GE FANUC 90-70
CPU311/CPU331
CPU Direct
Serial (RS-422)
IC697CMM711
Serial
YASKAWA
MP-920 CP-9200SH (CP-217) Prosec-T (T3,T3H,T2N, T2E) Tiny PLC (TCP32/37) DL-205 DL-305 DL-405
CPU Direct
Serial (RS-232C)
Toshiba
Serial (RS-232C)
POSCON
POSFA phld-1a/2a
SAIA
PCD2
Note
CPU Direct means serial communication through loader port of controllers CPU module.
(2)
RS-485
Connection
Diagram(K10S1,K10S,K30S,K60S,K100S
Touch
Caution n
In case of RS-485 connection, you have to connect resister at each terminal as follows for noise reduction. Controller Touch Screen Connector
1(11) 1 485(+) 485(-) 2(12) 3(13) 4(14) 5(15) RDA RDB SDA SDB SG
270
270
<
(2) Serial setup in Touch Screen Communication setup in Comm. Setup Menu are as follows : Serial Baud Rate : Same as controllers setup Serial Data Bit : 8bit(Fixed) Serial Stop Bit : 1bit(Fixed) Serial Parity Bit : None(Fixed) Serial Signal Level: Same as controllers setup Station No. at Communication Diagnosis(0~31) : Same as controllers setup
K10S, K30S, K60S, K100S K10S1 K60H,K200H None Refer to connection Diagram.(RS-232C) All Touch Screen
Warning
In case of Using Loader Port, Only above 3 wires have to be connected. Other wire connection except above 3 can cause controllers Mal-function or abnormal state.
(2) Serial Setup Special setup is not needed. Default communication setup of Touch Screen are as follows : Serial Baud Rate : 9600bps Serial Data Bit : 8bit Serial Stop Bit: 1bit Serial Parity Bit : None Serial Signal Level : RS-232C Station No. at Communication Diagnosis(0~31): Not used.