Professional Documents
Culture Documents
Attaching Server To Storage System - Master
Attaching Server To Storage System - Master
Reporting Problems
To send comments or report errors regarding this document, please email: UserCustomizedDocs@emc.com. For issues not related to this document, contact your service provider. Refer to Document ID: 1430479
Attaching a Linux Server with EMC PowerPath to a CX4-960 Storage System in a Fibre Channel Switch Configuration
This document explains how to attach a Linux server with EMC PowerPath to a CX4-960 in a Fibre Channel switch configuration. If you are an EMC partner, refer to the EMC Services Partner website to download the Unisphere server software mentioned in this guide. The partner site is available from the Navigator drop-down menu on Powerlink. IMPORTANT Some of the procedures in this document apply only to the server, only to the virtual machine, or to both the server and the virtual machine. Read each section carefully to determine where to perform the procedure. If you will configure your storage-system connections to your ESX or Hyper-V server, you must attach the ESX or Hyper-V server to your storage system before performing the steps in this document. For information on attaching an ESX or Hyper-V server, generate a new host attach document and select the appropriate ESX or Hyper-V server version.
The main topics in this document are: Before you start ............................................................................. Determining if your server has a supported configuration................ Installing HBAs in the server.......................................................... Installing or updating the HBA driver ............................................ Installing PowerPath software ....................................................... Installing Unisphere server software............................................... Connecting the storage system to the server in a Fibre Channel switch configuration ..................................................................... Registering the server with the storage system ................................ Verifying storage-system health...................................................... Setting storage-system failover values for the server initiators with Navisphere Manager..................................................................... 3 5 7 9 11 14 27 34 36 38
Verifying your high-availability Fibre Channel configuration ........... Configuring an existing storage system........................................... Preparing LUNs to receive data ...................................................... Sending Linux disk information to the storage system ..................... Verifying your failover configuration with PowerPath .....................
40 41 47 48 49
Attaching a Linux Server with EMC PowerPath to a CX4-960 Storage System in a Fibre Channel Switch Configuration
Read the release notes for your storage system, which are available in the Technical Documentation and Advisories section on the Powerlink website. If you have not done so already, complete the configuration planning worksheets (administrative worksheets) in the storage-system configuration planning guide or planning worksheets document. You can generate an up-to-date version of the planning guide customized for your installation from the Plan link on the storage-system support website. You must have a supported Windows host on the same network as the storage-system management ports. You can use this host: