3vt1708 2dc36 0aa0
3vt1708 2dc36 0aa0
3vt1708 2dc36 0aa0
3VT1708-2DC36-0AA0
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 80A RATED CURRENT IR= 63... 80A OVERLOAD PROT. II= 400... 800A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Similar to image
Technical data:
Product designation Width Height Depth Size of the circuit-breaker Acceptability for application Design of the overcurrent release Protective function of the overcurrent release Product function / ground-fault protection Continuous current / rated value Operating voltage / for main current circuit at 50 Hz / for AC / maximum at 60 Hz / for AC / maximum for DC / maximum Impulse voltage resistance / rated value Number of poles Active power loss / maximum Performance class for circuit breaker W V V V kV 690 690 250 8 3 7 N A mm mm mm 3VT1_5 molded case circuit breakers 75 130 80 3VT1 system protection TM LI No 80
3VT1708-2DC36-0AA0 Page 1/ 3
03/12/2014
Operating cycles / maximum Operating frequency 1 / rated value 2 / rated value Breaking capacity limit short-circuit current (lcu) at 240 V / rated value at 415 V / rated value at 500 V / rated value at 690 V / rated value Breaking capacity operating short-circuit current (lcs) at 240 V / rated value at 415 V / rated value at 500 V / rated value at 690 V / rated value Ultimate short-circuit current making capacity (Icm) / at 415 V / rated value Adjustable response current / of the current-dependent overload release initial value final value Adjustable response current / of the non-delayed short-circuit release initial value final value Type of mounting Design of the electrical connection / for main current circuit Arrangement of electrical connectors / for main current circuit Number of NC contacts / for auxiliary contacts Number of NO contacts / for auxiliary contacts Number of changeover contacts / for auxiliary contacts Product component undervoltage release mechanism Voltage trigger undervoltage release with leading contact Suitability for use / circuit breaker Item designation according to DIN EN 61346-2 Ambient temperature during operating minimum
1/h
120
Hz Hz
50 60
kA kA kA kA
40 25 12 6
kA kA kA kA kA
20 13 6 3 52
A A
63 80
A A
No No No Yes
-40
3VT1708-2DC36-0AA0 Page 2/ 3
03/12/2014
maximum during storage minimum maximum Derating temperature / for the rated value of the continuous current Utilization category Protection class IP Product function overload protection for zero conductors / short-circuit and overload protection of the thermal overload release mounting position
55
C C C
-40 55 40
A IP40
Yes No adjustable with vertical mounting surface +/-180 rotatable, with vertical mounting surface +/- 30 tiltable to the front and back 20,000 6,000
Mechanical operating cycles as operating time / typical Electrical operating cycles as operating time / typical
Certificates/approvals:
General Product Approval Declaration of Conformity Test Certificates other
other
Environmental Confirmations
Further information:
Information- and Downloadcenter (Catalogs, Brochures,) http://www.siemens.com/lowvoltage/catalogs Industry Mall (Online ordering system) http://www.siemens.com/lowvoltage/mall Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3VT1708-2DC36-0AA0/all Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VT1708-2DC36-0AA0 CAx-Online-Generator http://www.siemens.com/cax
last change:
Mar 3, 2014
3VT1708-2DC36-0AA0 Page 3/ 3