Contract

Project

REINFORCED CONCRETE DESIGN TO BS Ref: 8110


Section

engg/10/s4

Member

Date Page No.

Prepared NOEL Checked T.E

Company Project Title REINFORCED CONCRETE DESIGN TO BS 8110

Job Reference Design Engineer Date Project Description (if any)

engg/10/s4 NOEL

REINFORCED CONCRETE DESIGN TO BS 8110

Design Codes

BS 5950 BS 8110

Design Aids

SCALE Microsoft Excel AutoCAD

217582777.xls.ms_office

Contract

S4

REINFORCED CONCRETE DESIGN TO BS Ref: 8110


Section DESIGN OF ONE-WAY SPANNING RC SLAB Member Date Page No. Prepared

engg/10/s4

NOEL Checked

DESIGN OF ONE WAY REINFORCED CONCRETE SLAB TO BS8110 Design in accordance with BS 8110 Panel Identity : FIRSTFLOOR Location: Material Properties & Dimensions 10.000m => 4.000m => Exposure Conditions Reinforcement size Section size Loading Self Weight = False Ceiling = Terrazzo/Screed = Ceiling Plaster = Basic Services = Partition Load = Any other Load = Characteristic Dead Load, gk = Characteristic Imposed Load, qk = Design Load = 3.60 kN/m2 0.00 1.00 0.00 1.00 2.50 0.00 Specify - incidental 8.10 kN/m2 2.00 kN/m2 14.54 kN/m2 Support Conditions: One Way Slab Mild Main = 16 150 117 mm mm mm fy = fcu = lx = ly = ly / lx = 410 25 4.000 10.000 2.500 N/mm2 N/mm2 m m One Way Slab Cover = Distribution = width, b = Eff. depth, d2 = 25 10 1000 101 mm mm mm mm

depth, h = Eff. Depth, d1 =

One Way Slab Internal Span of Continuous Slab For Internal Span of Continuous Slab Support Moment = Span Moment = 14.7 14.7 kNm kNm

Reinforcement Design As, min = 225.0 mm2 M M/fcubd2 Support Span 14.7 14.7 0.043 0.043 z/d 0.940 0.940 z 110.0 110.0 As,req.(mm2) As,pr.(mm2) Bar Dia. Bar Spacing 374 10 200 393 374 225 Deflection Check Basic l/d = Service Stress, fs = Modification Factor, Mf = 26 243.8 N/mm2 1.536 Act. s/d = All. s/d = 34.19 39.94 393 314 10 10 200 250

Distribution Reinforcement

Deflection Control: Deflection ok!

DESIGN SUMMARY Slab Panel : FIRSTFLOOR designed as ONE - Way Spanning Slab Internal Span of Continuous Slab Slab designed for Dead Load of 8.1 kN/m2 and Imposed Load of 2 kN/m2 Slab Thickness =150mm with cover to Main reinforcement of 25mm Short Span Reinforcement: At Support Y10 at 200mm centres At Span Y10 at 200mm centres Distribution Reinforcement: Y10 at 250mm centres

PASS! PASS! PASS!

217582777.xls.ms_office 3/19/2014

Contract

S4 (2)

REINFORCED CONCRETE DESIGN TO BS Ref: 8110


Section DESIGN OF ONE-WAY SPANNING RC SLAB Member Date Page No. Prepared

engg/10/s4

NOEL Checked

DESIGN OF ONE WAY REINFORCED CONCRETE SLAB TO BS8110 Design in accordance with BS 8110 Panel Identity : FIRST FLOOR Location: Material Properties & Dimensions 10.000m => 4.000m => Exposure Conditions Reinforcement size Section size Loading Self Weight = False Ceiling = Terrazzo/Screed = Ceiling Plaster = Basic Services = Partition Load = Any other Load = Characteristic Dead Load, gk = Characteristic Imposed Load, qk = Design Load = 3.60 kN/m2 0.00 1.00 0.00 1.00 2.00 0.00 Specify - incidental 7.60 kN/m2 2.00 kN/m2 13.84 kN/m2 Support Conditions: One Way Slab Mild Main = 16 150 122 mm mm mm fy = fcu = lx = ly = ly / lx = 410 25 4.000 10.000 2.500 N/mm2 N/mm2 m m One Way Slab Cover = Distribution = width, b = Eff. depth, d2 = 20 10 1000 106 mm mm mm mm

depth, h = Eff. Depth, d1 =

One Way Slab End Span of Continuous Slab For End Span of Continuous Slab Support Moment = Span Moment = 19.0 19.0 kNm kNm

Reinforcement Design As, min = 225.0 mm2 M M/fcubd2 Support Span 19.0 19.0 0.051 0.051 z/d 0.939 0.939 z 114.6 114.6 As,req.(mm2) As,pr.(mm2) Bar Dia. Bar Spacing 466 10 150 524 466 225 Deflection Check Basic l/d = Service Stress, fs = Modification Factor, Mf = 23 228.0 N/mm2 1.502 Act. s/d = All. s/d = 32.79 34.55 524 314 10 10 150 250

Distribution Reinforcement

Deflection Control: Deflection ok!

DESIGN SUMMARY Slab Panel : FIRST FLOOR designed as ONE - Way Spanning Slab End Span of Continuous Slab Slab designed for Dead Load of 7.6 kN/m2 and Imposed Load of 2 kN/m2 Slab Thickness =150mm with cover to Main reinforcement of 20mm Short Span Reinforcement: At Support Y10 at 150mm centres At Span Y10 at 150mm centres Distribution Reinforcement: Y10 at 250mm centres

PASS! PASS! PASS!