Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Appendix C Specifications

TB842 ModuleBus Optical Port

TB842 ModuleBus Optical Port


Features
1 fiber optic port for the Optical ModuleBus expansion Connection to CI801 and CI840

Description TB842
TB842 ModuleBus Optical Port is a communication interface between the CI801 or CI840 FCI and the TB820 ModuleBus Modem of an I/O cluster or ABB drives units via the Optical ModuleBus. TB842 connects to CI801 via TB806 or CI840 via TU847 and TB806. TB842 can be used in both a simplex optical configuration as well as in a duplex optical configuration. In a simplex configuration, the optical ModuleBus nodes are connected in a ring. In a duplex configuration, the optical ModuleBus nodes are connected in a row. TB842 has two connectors for fiber optic connections and a connection to the communication interface module. The module is equipped with Transmitter/Receiver for up to 10 Mbit/s. Both plastic and HCS (Hard Clad Silica) optic fiber with connectors (Agilents, former Hewlett-Packard, Versatile Link) can be used with the TB842.

3BSE020923R5021

255

Technical Data

Appendix C Specifications

Technical Data
Table 61. Technical Data TB824
Item Application Configuration Fibers Connector Optical ModuleBus TB842 S800 I/O clusters and ABB variable drives Simplex and duplex optical fiber Plastic and HCS (Hard Clad Silica) Agilents, former Hewlett-Packard, Versatile Link Fiber optic interface, one transmit and one receive connection for max. 10 Mbit/s. Wavelength 650 nm Indicators Tx LED: Yellow indicates transmitting of data on the optical ModuleBus Rx LED: Yellow indicates receiving of data on the optical ModuleBus Current consumption +5 V Current consumption +24 V Power dissipation Equipment Class Ingress Protection Width Depth Height Weight 100 mA 20 mA 0.5 W Class I according to IEC 60536; (earth protected) IP20 according to IEC 60529 17.6 mm (0.69) 42.3 mm (1.67) 56.7 mm (2.23) 40 g (0.088 lbs.)

256

3BSE020923R5021

Appendix C Specifications

Connections

Connections
Table 62. Optical ModuleBus Connections (X2)
Port Tx Rx Duplex Signals Transmit data to down-stream device Receive data from up-stream device Simplex Signals Transmit data to first device Receive data from last device

Opto Cable for TB842 according to HP


Plastic Optical Fiber (POF) (TK811V... or TK812V...) up to 15 meters. Extra low loss attenuation Simplex or duplex cable Latching simplex or duplex connector. Cable attenuation maximum 4 dB

Hard Clad Silica (HCS) fiber up to 200 meters. Riser or plenum Simplex or duplex cable Latching simplex or duplex connector Cable attenuation maximum 2 dB

3BSE020923R5021

257

Block Diagram TB842

Appendix C Specifications

Block Diagram TB842

X1 E O E O RX TX X2

258

3BSE020923R5021

You might also like