Features
Compact and robust stainless steel assembly 1.4435 (316L) Piezoresistive and Pt 100 measuring element Gauge, absolute or sealed gauge Standard DIN pressure ranges from 0100 mbar to 01000 bar Calibration available for all common pressure units Complies with the EMC directive 89/336/EEC High reliability Short delivery time Customized versions due to modular assembly Available as level or flange transmitter Reverse polarity and short circuit protected Media temperature up to 150C (optional)

Typical applications
Machine installations Industrial process control Heating and ventilation Environmental monitoring Food industry Mobile hydraulics Test and calibration systems

- feel the Dif ference

Specifications
Pressure range Overpressure [bar] 0.1 0.5 3 bar > 0.5 2 3 x FS
(min. 3 bar)

> 2 25 3 x FS

> 25 600 3 x FS
(max. 850 bar, optional 1500 bar)

> 600 1000 1500 bar

Burst pressure Accuracy1) Thermal shift Zero Span Response time Long term stability (1 year)
1)

[bar] [ % FS] [ % FS/C] 070C -2585C 070C -2585C

30 0.5

30 0.5

3 x FS
(min. 25)

> 850
(optional 1500 bar) (optional 0.25, 0.1)

1500 1

(optional 0.25)

(optional 0.25, 0.1)

(optional 0.25, 0.1)

0.5

0.5

(optional 0.5, 0.25)

0.06 0.08 0.015 0.02 < 1 ms/1090% FS < 4 mbar

0.03 0.04 0.015 0.02

0.015 0.02 0.015 0.02

0.015 0.02 0.015 0.02

0.015 0.02 0.015 0.02

< 4 mbar

< 0.2% FS

< 0.2% FS

< 0.2% FS

Zero based non-conformity according to DIN 16086, including hysteresis and repeatability

Temperature measuring range Temperature measuring range Optional measuring ranges: lower range limit upper range limit Accuracy (probe, electronics, adjustment): -25100C on request -50C 150C 2C 4 20 mA Current transmitter 1530 V DC < 0.1% FS
+Vin Pout A A

Output signal Type Supply voltage (Ub) Supply voltage influence Circuit diagram P: Pressure T: Temperature

0 20 mA Current transmitter 1530 V DC < 0.1% FS


+Vin Pout A A

0 5V / 0 10 V Voltage transmitter 1530 V DC < 0.1% FS


+Vin Pout Tout GND V V

P T

P T

P T

I I

Tout I GND

Tout I GND

Load resistance Load resistance influence

(Ub 5V) / 0.02A < 0.1% FS Materials

(Ub 5V) / 0.02A < 0.1% FS

RL > 10kOhm < 0.1% FS

Process connection, diaphragm, housing Seals (standard)

Stainless steel 1.4435 (316L) Viton

(other materials on request) (other materials see ordering information)

Electromagnetic compability
Standard Emission: EN 50081-1:1992 EN 55022:1994 Immunity: EN 50082-2:1995 EN 61000-4-2:1995 ENV 50140:1993 ENV 50204:1995 EN 61000-4-4:1995 ENV 50141:1993 Generic emission standard Emission, class B Level Typical interferences

Generic immunity Electrostatic discharge Radiated electro-magnetic field Radiated electro-magnetic field (GSM) Fast transients (burst) Conducted radio-frequency

4kV contact, 8kV air 10V/m, 80-1000 MHz, 80% AM 1kHz 10V/m, 950 MHz, 200Hz on/off 2 kV 10V, 0.15-80 MHz, 80% AM 1kHz

Cellular phones, radio sets Digital portable phones Motors, valves Cellular phones, radio sets

The pressure transmitter ATM fulfill the emission and immunity requirements described in the EMC directive 89/336/EEC.

Ordering Information
Type Pressure type ATM/T Gauge Absolute Sealed gauge 0100 mbar 0160 mbar 0250 mbar 0400 mbar 0600 mbar 01.0 bar 01.6 bar 02.5 bar 04.0 bar 06.0 bar 010 bar 016 bar 025 bar 040 bar 060 bar 0100 bar 0160 bar 0250 bar 0400 bar 0600 bar 01000 bar Special calibration -25100C (standard) customized temperature measurement range G 1/2 M, frontal diaphragm G 1/2 M, flush diaphragm Special process connection Connector DIN 43650 (screwed on1)) 2) Connector Binder 723, 5-pin 2) Connector Binder 723, 5-pin (screwed on1)) 2) Connector MIL C26482, (10-6) 2) PE cable 3) 4) PUR cable 3) Teflon cable 3) Special electrical connection 0 5 V DC 010 V DC 020 mA 420 mA Special output signal Pressure 0.5 % FS 0.25% FS 0.1 % FS (on request)

26 X . XXXX . XXXX . XX . XXX


26 1 2 3 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 99

Pressure range

3 3 3 3 3 3 3 3

Temp. measuring range Process connection

(Fig. 5) (Fig. 6)

14 15 99 IP 65 IP 67 IP 67 IP 40 IP 67 IP 67 IP 67 01 03 43 06 13 15 21 99 46 47 00 05 99

Elektrical connection

(Fig. 10) (Fig. 11) (Fig. 12) (Fig. 13) (Fig. 14) (Fig. 14) (Fig. 14)

Output signal

Accuracy

Temperature according to data sheet according to data sheet according to data sheet

0 1 2

Temperature range Transmitter

Compensated 070C (media temperature 0 80C) Compensated -2585C (media temperature -25100C) Compensated -2585C (media temperature -25150C) Special temperature range

0 1 2 9

Options

Electronics packed ingul: Gauge pressure Absolute and sealed gauge pressure Special oil filling: ASEOL Food Halocarbon Seals: EPDM Kalrez Special options
4)

C D G H S T Z

1) 2)

Zero offset and span adjustable Cable socket connector not included 3) Please specify the required cable length

Suitable for drinking water (food approved)

Pressure Connection
20,5

Dimensions
Version for media temperature up to 100C

Electrical Connection
46.5

Pin 1 2 3 +Vin Pout GND Tout

G 1/2 M 18,4

SW27

34,5

Fig. 5

74

24

Fig. 10
19,5

3 1 2

G 1/2 M

18,4

24

33,5

SW27

Version for media temperature up to 150C

Fig. 6

101

Fig. 11

68

Cable socket connector


3 2 1 4 5

Pin 1 2 3 4 Pout Tout +Vin GND

74.5

Fig. 12
Cable socket connector
A B C D F E

Pin A B C D +Vin GND Pout Tout

Fig. 13

62.5

Colour white yellow brown green +Vin GND Pout Tout