General contents
Contents
Contents
Distribution
Horizontal busbars up to 1600A Lateral Linergy busbars up to 1600A Lateral flat busbars up to 1600 A up to 3200 A Form 2 partitioning Form 3 partitioning
Enclosures
Cubicles, frameworks IP55 cover panels Plinth, gland plates Accessories
Dimensions
Cubicles
401F_E0010TDM.indd
Index
Index
03000
03583 04502 04503 04504 04505 04506 04516 04518 04525 04526 04528 04536 04538 04545 04546 04548 04550 04634 04635 04636 04637 04640 04641 04642 04645 04651 04662 04664 04671 04678 04901 04911 04924 04943 04955 04956
Module
401E22905/6 401E22215/2 401E22215/2 401E22215/2 401E22215/2 401E22215/2 401E22315/2 401E22315/2 401E22315/4 401E22315/4 401E22315/4 401E22110/1 401E22110/1 401E22110/3 401E22110/3 401E22110/3 401E22110/3 401E22215/3 401E22215/3 401E22215/3, 401E22315/5 401E22315/5 401E22110/1, 401E22110/3 401E22110/1, 401E22110/3 401E22215/3, 401E22315/5 401E22315/3 401E22215/3 401E22110/1, 401E22110/3, 401E22315/2, 401E22315/4 401E22110/1, 401E22110/3 401E22110/3 401E22315/2, 401E22315/4 401E22905/6 401E22905/4 401E22905/3 401E22905/6 401E22905/6 401E22905/6 401E23120/2 401E23110/2 401E23110/2 401E23110/2 401E23110/2 401E23110/2 401E23110/2 401E23110/2 401E23110/4 401E23110/4 401E23110/4 401E23110/4 401E23110/4 401E23110/4 401E23110/4 401E22905/4 401E22905/3 401E22905/3 401E22905/4
04000
06000
06461 06501 06502 06503 06512 06513 06514 06515 06522 06524 06525 06533 06535 06537 06538 06540 06543 06545 06555
401F_E0012TDM.indd
Index
Index
Designation
Form 2 horiz. cover W300 D500 Form 2 horz. cover W300 D500+300 Form 2 horz. cover W700 D500
Module
401E22905/5 401E22905/5 401E22905/5
08000
08566 08911
Front plate support frame, W=650mm Earthing wire, 6mm Bottom support for lateral vertical busbar D500 Bottom support for lateral vertical busbar D800 Bottom support for lateral vertical busbar D800, 115mm spacing Horizontal busbar support W300, D500 Horizontal busbar support W300, D800 Horizontal busbar support D800, 115mm spacing Vertical lateral busbar support D500 Vertical lateral busbar support D800 Vertical lateral busbar support D800, 115mm spacing Entry cable gland plate W300 D500 Entry cable gland plate W300 D800 Entry cable gland plate W700 D500 Entry cable gland plate W700 D800 Earthing lead, 6mm section, 160mm length, 8.3mm terminal Earthing lead, 25mm section, 350mm length, 8.3mm terminal Swing 19" rack coupling kit 4 lifting eyes M12 4 lifting brackets Front plinth 100x300 Front plinth 200x300 Front plinth 100x700 Front plinth 200x700 2 Plinth side panels 100x500 2 Plinth side panels 200x500 2 Plinth side panels 100x700 2 Plinth side panels 200x700
401E23110/3 401E23120/2 401E22315/2, 401E22315/4 401E22315/2, 401E22315/4 401E22315/2, 401E22315/4 401E22110/1, 401E22110/3 401E22110/1, 401E22110/3 401E22110/1, 401E22110/3 401E22315/2, 401E22315/4 401E22315/2, 401E22315/4 401E22315/2, 401E22315/4 401E23110/5 401E23110/5 401E23110/5 401E23110/5 401E23120/2 401E23120/2 401E23110/3, 401E23120/2 401E23120/2 401E23120/2 401E23110/5 401E23110/5 401E23110/5 401E23110/5 401E23110/5 401E23110/5 401E23110/5 401E23110/5
NSY
NSYAS500 NSYAS800 NSYAS800L NSYBHS500 NSYBHS800 NSYBHS800L NSYBVS500 NSYBVS800 NSYBVS800L NSYEC351 NSYEC381 NSYEC751 NSYEC781 NSYEL166D8 NSYEL3525D8 NSYSFBK19 NSYSFEB NSYSFELB NSYSPF3100 NSYSPF3200 NSYSPF7100 NSYSPF7200 NSYSPS5100 NSYSPS5200 NSYSPS8100 NSYSPS8200
401F_E0012TDM.indd
General presentation
Presentation
PD391264b_SE
PD391265b_SE
The Prisma Plus functional system can be used for all types of low-voltage distribution switchboards (main, subdistribution and final) up to 3200 A, in commercial and industrial environments. Switchboard design is very simple: A metal structure The switchboard is made up of one or more frameworks combined side-by-side or back-to-back, on which a complete selection of cover panels and doors can be mounted.
PD391266b_SE
A distribution system Horizontal busbars or vertical busbars positioned in a lateral compartment or at the rear of the cubicle are used to distribute electricity throughout the switchboard. Complete functional units Each device is part of a functional unit comprising: b dedicated mounting plate for device installation b front plate to block direct access to live parts prefabricated busbar connections b devices for on-site connections. Each functional unit contributes to a function in the switchboard. The functional units are modular and are arranged rationally, one on top of another, within the enclosure. The system includes everything required for functional unit mounting, supply and onsite connection. The components of the Prisma Plus system and those of the functional units in particular have been designed and tested taking into account device characteristics. This design approach ensures a high degree of reliability in system operation and optimum safety for personnel.
PD391267b_SE
401F_E10020.indd
General presentation
Presentation
PD391268b_SE
PD391269b_SE
401F_E10020.indd
General presentation
Characteristics
Presentation
PD391272b_SE
Electrical characteristics
Use of the components in the Prisma Plus functional system ensures the creation of switchboards complying with standards IEC 50298, EN 50298, IEC 61439-2 and EN 61439-2, as well as local versions with the following electrical characteristics: b rated insulation level of main busbars: 1000 V b rated operational current Ie: 3200 A b rated peak withstand current Ipk: 187 k b rated short-time withstand current Icw: 85 kA rms/1 second b frequency: 50/60 Hz.
Mechanical characteristics
b b b b b b b b v - - v v b Steel sheet metal. Electrophoresis treatment + hot-polymerised polyester epoxy powder. White colour RAL 9001. Can be dismantled. Can be combined side-by-side and back-to-back. Degree of protection: IP55. Degree of protection against mechanical impacts: IK10 with door. Framework dimensions: two widths: W 300: cable compartment W 700: device compartment or cable compartment two depths: 500, 800 mm height: 2000 mm Indoor cubicles.
401F_E10020.indd
General presentation
Presentation
Decisions concerning the Form of separation and the degree of protection are the subject of an agreement between the manufacturer and the user.
E33522
Form 2
PH System offers Form 2 cubicles It is a physical separation of horizontal, vertical busbars from the functional units, complying with standard IEC 61439-2
Form 2b.
E33523
Form 3b
PH System offers Form 3b cubicles. They are achieved by separating from one another the functional units of a Form 2 switchboard. Device must be equipped of downstream terminal shields.
Form 3b.
401F_E10020.indd
Functional units
Switchgears
Catalogue numbers
DD384395
Cat. no.
400E21100 400E21110 400E21120 400E21130 400E21150 400E21200 400E21210 400E21160 400E21250 400E21400 400E21500400E21600
Intermediaire uprights.
401F_E21000.indd
Distribution
Horizontal busbars
Busbar calculation
Number and size of copper busbars
Permissible current (A) No. of bars/phase
IP55 750 1 bar 60 x 5 900 1 bar 80 x 5 1250 2 bars 60 x 5 1600 2 bars 80 x 5 Note: the permissible current values for the busbars are given for an ambient temperature of 35 C around the switchboard.
Number of supports
Framework width Size of bars (mm) No. of supports lcw (kA rms/1 s) (mm)
y 15 y 25 y 30 y 40 y 50 1 bar 60 x 5 1 bar 80 x 5 2 bars 60 x 5 2 bars 80 x 5 All sizes
W 700 mm
2 1
3 2
W 300 mm
DD384397
NYBSHS500
Busbar selection
Flat busbars, W 2000 mm
Designation
Copper bar without holes, 60 x 5 Copper bar without holes, 80 x 5
Cat. no.
04536 04538
Busbar supports
Two fixed supports for 700 mm wide frameworks and one fixed support for 300 mm wide frameworks are mandatory. If more supports are required, use free supports. Designation
Fixed support and free support. Distance between busbar centres Fixed support for horizontal bars Free support (additional)
DD381226
04664
DD381225
04662
Joints
DD384398
Designation
1 joint for bars
Cat. no.
W 60 mm 04640 W 80 mm 04641 Note: when installed at the bottom of cubicles, the busbars must be partitioned, see page401F22905.indd/2.
Joints.
401F_E22110.indd
Distribution
Horizontal busbars
Up to 3200 A
Flat copper bars 10 mm thick
Catalogue numbers
The bars are secured by insulated supports attached to the framework. The tables opposite indicate: b the number and size of the bars to be used, depending on the permissible current level in the busbars b the number of busbar supports for each type of framework, depending on: v the size of the busbars v the rated short-time withstand current Icw. For more information on busbar calculations, see DESW016. The modularity of the busbar is 3 modules.
DD384396
Busbar calculation
Number and size of copper busbars
Permissible current (A) No. of bars/phase
IP55 1080 1 bar de 50 x 10 1250 1 bar de 60 x 10 1600 1 bar de 80 x 10 1850 2 bars de 50 x 10 2000 2 bars de 60 x 10 2500 2 bars de 80 x 10 2900 2 bars de 100 x 10 Note: the permissible current values for the busbars are given for an ambient temperature of 35 C around the switchboard.
3 2
W 300 mm
W 300 mm
401F_E22110.indd
Distribution
Horizontal busbars
Up to 3200 A
Flat copper bars 10 mm thick
Catalogue numbers
DD384397
NYBSHS500
Busbar selection
Flat busbars, W 2000 mm
Designation
Copper bar without holes 50 x 10 Copper bar without holes 60 x 10 Copper bar without holes 80 x 10 Copper bar without holes 100 x 10
Cat. no.
04545 04546 04548 04550
Busbar supports
Two fixed supports for 700 mm wide frameworks and one fixed support for 300 mm wide frameworks are mandatory. If more supports are required, use free supports.
Fixed support and free support.
Designation
Distance between busbar centres Fixed support for horizontal bars Free support (additional) for bars
Bar width
y 80 mm > 80 mm y 80 mm > 80 mm
Designation
Distance between busbar centres Fixed support for horizontal bars Free support (additional) for bars
DD381226
Bar width
y 80 mm > 80 mm y 80 mm > 80 mm
DD384398
04664 Joints.
04662
Joints
Designation
1 joint for bars
Cat. no.
Width 50 and 60 mm 04640 Width 80 and 100 mm 04641 Note: when installed at the bottom of cubicles, the busbars must be partitioned, see page401F22905.indd/5.
401F_E22110.indd
Distribution
Catalogue numbers
The table opposite indicates: b the catalogue numbers of the bars to be used, depending on the permissible current level in the busbars b the number of supports required, depending on the rated short-time withstand current (Icw in kA rms/1s). For more information on other ambient temperatures, see DESW016.
Busbar calculation
Linergy busbars Cat. no.
y 25 y 30 y 40 y 50 y 60 y 65 y 75 y 85
Linergy 630 Linergy 800 Linergy 1000 Linergy 1250 Linergy 1600
3 4 5 7 8
Note: The permissible current values for the busbars are given for an ambient temperature of 35 C around the switchboard. The bottom support also maintains the bars in position. Each catalogue number represents one bar.
PD391273b_SE
Busbar selection
Linergy busbars, W 1670 mm
Cat. no. selection: see the table below. Each bar is supplied with a stop for the bottom support:
DD381233 DD381234 DD381235
Busbars up to 1600 A. The bottom support also maintains the bars in position.
401F_E22215.indd
Distribution
Catalogue numbers
DD384399
Busbar supports
Supports are used to install busbars to the left or right of the device zone. They are supplied with 8.8 class mounting hardware.
06502
Designation
Busbar supports
DD380741 DD380742
Cat. no.
04651
04651
Busbar supports.
Each bar is supplied with a stop for installation on the bottom support.
DD384400
Horizontal-busbar connections
Designation
These connections are used to connect horizontal busbars, 75 mm centre distance, 5 or 10 mm thick, to lateral Linergy busbars. Supplied with mounting hardware. Cat. no.
04634 04635 04636 04636 + 04642 Connection to horizontal busbars, 1000 A connection 5 mm thick 1600 A connection Connection to horizontal busbars, width of horizontal bars y 80 mm 10 mm thick width or horizontal bars > 80 mm Connection 04635 to horizontal busbars, 5 mm thick.
DD384401
401F_E22215.indd
Distribution
Lateral at busbars
up to 1600 A
Busbars 5 mm thick
Catalogue numbers
The bars are secured by insulated supports. Three fixed supports, attached to the framework, are mandatory. If necessary, additional free supports may be used. The bars rest on a bottom support. The table opposite indicates: b the number and size of the bars to be used, depending on the permissible current level in the busbars b the number of supports required in a cubicle, depending on the rated short-time withstand current (Icw).
NSYBVS500
Busbar calculation
IP55 750 900 1250 1600
No. of bars/phase
1 bar de 60 x 5 1 bar de 80 x 5 2 bars de 60 x 5 2 bars de 80 x 5
Note: The permissible current values for the busbars are given for an ambient temperature of 35 C around the switchboard.
DD384402
Busbar selection
Flat busbars, W 1675 mm
Designation
Copper bar with holes 60 x 5 Copper bar with holes 80 x 5
Cat. No.
04516 04518
04662
Busbar supports
Three fixed supports are required to maintain the busbars. If more than three supports are required, use additional free supports. Designation Cubicle W 300 D 500 D 800
75 NSYBVS800 04662
DD381650
Distance between 75 busbar centres Fixed support for lateral NSYBVS500 flat busbars Free support (additional) 04662
DD383350
NSYBVS500.
04662.
Busbar chocks
The bars are secured by three mandatory fixed supports and two free supports.
DD384403
The bottom support maintains the bars in position. It is not considered a busbar support. Designation Cubicle W 300 D 500 D 800
75 NSYAS800 115 NSYAS800L
Distance between 75 busbar centres Bottom support for lateral NSYAS500 flat busbars
DD383352
NSYAS500 NSYAS500.
401F_E22315.indd
Distribution
Lateral at busbars
up to 1600 A
Busbars 5 mm thick
Catalogue numbers
Horizontal-busbar connections
DD384405
To satisfy safety clearances, the assembly points on adjacent bars must be staggered as shown above.
In case of direct connection (75 or 115 mm centre distance) with a horizontal busbars, bottom support part no. NSYAS500, NSYAS800 or NSYAS800L are not required.
401F_E22315.indd
Distribution
Lateral at busbars
up to 3200 A
Busbars 10 mm thick
Catalogue numbers
The bars are secured by insulated supports. Three fixed supports, attached to the framework, are mandatory. If necessary, additional free supports may be used. The bars rest on a bottom support. The table opposite indicates: b the number and size of the bars to be used, depending on the permissible current level in the busbars b the number of supports required in a cubicle, depending on the rated short-time withstand current (Icw). Above 1600 A, the busbars must be doubled and installed in two busbar sections, side by side. In this case, they must be interconnected by three equipotential links.
DD384402
Busbar calculation
IP55 1080 1250 1600 1850 2000 2500 3200
5 3
Note: The permissible current values for the busbars are given for an ambient temperature of 35 C around the switchboard.
NSYBVS500
Busbar selection
Flat busbars, W 1675 mm
Designation
Copper bar with holes 50 x 10 Copper bar with holes 60 x 10 Copper bar with holes 80 x 10
Cat. no.
04525 04526 04528
04662
DD381505
D 800
75 NSYBVS800 04662
D 800
115 NSYBVS800L 04678
NSYBVS500. The bars are secured by three mandatory fixed supports and two free supports.
DD384403
04662.
Busbar chocks
The bottom support maintains the bars in position. It is not considered a busbar support. Designation
Distance between busbar centres Bottom support for lateral flat busbars
D 800
75 NSYAS800 115 NSYAS800L
Busbars up to 3200 A.
DD383352
NSYAS500
NSYAS500.
401F_E22315.indd
Distribution
Lateral at busbars
up to 3200 A
Busbars 10 mm thick
Catalogue numbers
Connection with a horizontal busbars, 10 mm thick. In this case, use the bottom support ref. NSYAS500, NSYAS800 or NSYAS800L. Designation
Connection vert. busbars (1 bar/phase) with horizontal bars
Horizontal Busbars
W y 80 mm W > 80 mm W y 80 mm W > 80 mm W y 80 mm W > 80 mm
Vert. Busbars
50/60 mm 50/60 mm 80 mm 80 mm 50/80 mm 50/80 mm
Cat. no.
04636 04636 + 04642 04637 04637 + 04642 04637 04637 + 04642
The connection between horizontal busbars, 10 mm thick, and lateral flat busbar is direct, after drilling the bars.
DD383367
DD384406
DD383399
To satisfy safety clearances, the assembly points on adjacent bars must be staggered as shown above.
In case of direct connection (75 or 115 mm centre distance) with a horizontal busbars, bottom support part no. NSYAS500, NSYAS800 or NSYAS800L are not required.
401F_E22315.indd
Distribution
Form 2 partitioning
Catalogue numbers
Separation of busbars from the functional units.
Configuration Form 2
Form 2 partitioning is essential to ensure excellent protection for the installation and operators working in the switchboard. When added to standard protection features (terminal shields, prefabricated connections, etc.), it eliminates the risk of direct contacts with live parts. Prisma Plus offers Form 2b. Form 2b provides much better safety than Form 2a, notably during connection, because the terminals are separated from the busbars.
PD391274b_SE
401F_E22905.indd
Distribution
Form 2 partitioning
Catalogue numbers
DD384407
Cat. no.
06545 04924
06545.
DD384408
DD383356
Partitioning extension
For the PH system switchboards 800 mm depth (500 + 300), a partitioning extension for 300 mm depth is required. Designation
Partitioning extension in 800 mm depth
DD384441
Cat. no.
06543
06543.
401F_E22905.indd
Distribution
Form 2 partitioning
Catalogue numbers
DD384409
DD383360
Cat. no.
06540
06540.
DD384410
Inter-cubicle partitioning
Metal partition, used to separate two adjacent cubicles. It is made up of two panels, each 850 mm high. The top and bottom ends have knock-outs for horizontal busbars. Supplied with the necessary supports and hardware, the partition is mounted on the framework and does not hinder installation of the functional mounting plates Cat. no. selection Designation
Inter-cubicle partitioning D 500 mm D 800 mm
Cat. no.
06555 04911 + 06543
06555.
DD383362
401F_E22905.indd
Distribution
Form 2 partitioning
Catalogue numbers
DD384412
Set of two barriers (front and rear), plus a slotted rear panel for efficient natural convection in the switchboard. The set can be used to partition horizontal busbars installed at the top or bottom of the cubicle. The space required for the busbars is not increased. Cat. no. selection Designation
W 300 mm W 700 mm D 500 mm D 800 mm D 500 mm D 800 mm
Cat. no.
06560 06563 06570
Note: when the busbars are at the bottom of the cubicle, gland plates are mandatory.
DD384411
401F_E22905.indd
Distribution
Form 3 partitioning
Catalogue numbers
DD384420
Form 3 partitioning
Front connection
Presentation A horizontal metal partition can be used to physically separate functional units from one another. It is fixed at the rear by a support (two uprights) secured to the framework (500 mm deep) or to the intermediate uprights (800 mm deep frameworks). A set of brackets can be used to install partial Form 3 partitioning in the cubicle. It does not take up any useful space in the switchboard. Cat. no. selection Designation
Horizontal metal partition, W 650 mm Rear support for partitions, W 650 mm 6 universal angle brackets
DD384422
Cat. no.
04901 04943 03583
04901 + 04943.
DD384421
Rear connection
Presentation For rear connection, in addition to the horizontal partitions, vertical partitions are required at the rear of each functional unit. There are two heights: b 3 to 4 modules b 5 to 6 modules. Cat. no. selection Designation
Vertical partitions (two cat. no. per functional unit)
DD383396
Cat. no.
3 to 4 modules 5 to 6 modules 04955 04956
401F_E22905.indd
Enclosures
Cubicles, frameworks
Catalogue numbers
DD384413
Cat. no.
06502 x 2 06514
b Composition of catalogue numbers: v 2 frames v 2 flanges v mounting hardware v 4 uprights v 1 roof. b Roof characteristics: - equipped with a factory-mounted polyurethane (PUR) gasket - supplied with mounting hardware - with markings for clear identificatuion of cable-running zones b The cables compartment can be mounted on the right or left. b Can be combined side-by-side or back-to-back. b Receive the IP55 cover panels. An earthing braid (NSYEL166D8 or NSYEL3525D8) must be installed between the roof and the frame.
06502 x 2 + 06514.
DD384414
Cat. no.
06502 06503 06515
b Composition of catalogue numbers: v 2 frames v 2 flanges v mounting hardware v 4 uprights + intermediary uprights v 1 roof. b Roof characteristics: - equipped with a factory-mounted polyurethane (PUR) gasket - supplied with mounting hardware - with markings for clear identificatuion of cable-running zones. b The cables compartment can be mounted on the right or left. b Can be combined side-by-side or back-to-back. b Receive the IP55 cover panels. An earthing braid (NSYEL166D8 or NSYEL3525D8) must be installed between the roof and the frame.
401F_E23110.indd
Enclosures
Cubicles, frameworks
Catalogue numbers
DD384415
Cat. no.
06501 x 2 06512
b Composition of catalogue numbers: v 2 frames v mounting hardware v 4 uprights v 1 roof. b Roof characteristics: - equipped with a factory-mounted polyurethane (PUR) gasket - supplied with mounting hardware - with markings for clear identificatuion of cable-running zones. b The cables compartment can be mounted on the right or left. b Can be combined side-by-side or back-to-back. b Receive the IP55 cover panels. An earthing braid (NSYEL166D8 or NSYEL3525D8) must be installed between the roof and the frame.
06501 x 2 + 06512.
DD384416
Designation
Cat. no.
06501 06502 06512
b Composition of catalogue numbers: v 2 frames v mounting hardware v 2 adapted uprights v 1 roof. b Roof characteristics: - equipped with a factory-mounted polyurethane (PUR) gasket - supplied with mounting hardware - with markings for clear identificatuion of cable-running zones. b The cables compartment can be mounted on the right or left. b Can be combined side-by-side or back-to-back. b Receive the IP55 cover panels. An earthing braid (NSYEL166D8 or NSYEL3525D8) must be installed between the roof and the frame.
Designation
Cat. no.
06501 x 2 06513
b Composition of catalogue numbers: v 2 frames v mounting hardware v 4 uprights v 1 roof. b Roof characteristics: - equipped with a factory-mounted polyurethane (PUR) gasket - supplied with mounting hardware - with markings for clear identificatuion of cable-running zones. b The cables compartment can be mounted on the right or left. b Can be combined side-by-side or back-to-back. b Receive the IP55 cover panels. An earthing braid (NSYEL166D8 or NSYEL3525D8) must be installed between the roof and the frame.
401F_E23110.indd
Enclosures
Cubicles, frameworks
Catalogue numbers
DD384417
Cat. no.
08566
b Reversible for left or right-hand opening. b Secured at two points. b Can be mounted on 700 mm wide cubicles.
DD384418
Framework combinations
The PH system frameworks can be combined side-by-side or back-to-back. A combination kit is required.
Cat. no.
NSYSFBK19
(1) Back to back association must be shipped individually and combined during on-site installation.
DD384419
401F_E23110.indd
Enclosures
Catalogue numbers
DD384423
Front panel
W 700 mm door
Designation
Plain door Transparent door W 300 mm W 700 mm W 700 mm
Cat. no.
06522 06524 06525
06525.
b Equipped with a factory-mounted polyurethane (PUR) gasket. b Reversible for left or right-hand opening. b Equipped with a black handle and keylock (key 405). An earthing wire (08911) must be installed between the door and the frame. To connect it, a M6 captive nut from the set cat. no. 06461 is required.
DD384424
Rear panel
Rear panel
Designation
Rear panel W 300 mm W 700 mm
Cat. no.
06533 06537
06537.
b Equipped with a factory-mounted polyurethane (PUR) gasket. b Supplied with mounting hardware. b One-piece, reinforced panel designed to ensure the degree of protection. An earthing braid (NSYEL166D8 or NSYEL3525D8) must be installed between the rear panel and the frame.
DD384425
Side panel
Side panel
Designation
Set of two side panels D 500 mm D 800 mm
Cat. no.
06535 06538
06535.
b Equipped with a factory-mounted polyurethane (PUR) gasket. b Supplied with mounting hardware. An earthing braid (NSYEL166D8 or NSYEL3525D8) must be installed between the lateral panels and the frame.
401F_E23110.indd
Enclosures
Catalogue numbers
DD384428
The plinth is made up of two catalogue numbers: b one catalogue number comprising four corner posts + two cross-pieces (front and rear), that can be used in side-by-side combinations or stacked to form a plinth 200 mm high (maximum) b one catalogue number comprising two side plates (500 or 800 mm). Each catalogue number is supplied with the necessary hardware. Width Depth Plinth H 100
Front and rear crosspieces Lateral cross- Front and rear Lateral crosspieces cross-pieces pieces NSYSPF3200 NSYSPF7200 NSYSPS5200 NSYSPS8200 NSYSPS5200 NSYSPS8200
Plinth H 200
300 700
NSYSPF7100 + NSYSPS5100.
DD384427
Cat. no.
NSYEC351 NSYEC751 NSYEC381 NSYEC781
NSYEC751.
401F_E23110.indd
Enclosures
Accessories
Catalogue numbers
DD384440
Lifting rings
Designation
4 lifting rings 4 lifting brackets
DD383348
Set of four lifting rings screwed to the framework. Use a set of lifting rings for each framework (W 700 mm) containing devices. When two cubicles with devices have been combined, use a lifting beam. Cat. no.
NSYSFEB NSYSFELB
DD383349
Screws/Nuts
Designation
Set of 20 screws + M6 nuts
Cat. no.
06461
Earthing leads
Length (mm)
b Mandatory to ensure earth continuity of side panels, roof and door. b Material: terminal of brass and copper delivered with PVC cover, green and yellow. Section (mm) Terminal (mm) Cat. no.
NSYEL166D8 NSYEL3525D8 160 6 8.3 350 25 8.3 Note: composition set of 10 leads (nuts and washers not delivered).
The wire is equipped with a 5 mm diameter lug at one end and a 6 mm diameter lug on the other. Designation
Earthing wire, 6 mm
Cat. no.
08911
The wire is equipped with a 5 mm diameter lug at one end and a 6 mm diameter lug on the other. The earthing wire is used to earth: b a door or wicket door with devices b a front-plate support frame equipped with switchgear in a cubicle.
Coupling kit
For coupling enclosures either side-by-side or back-to-back (1): b Fixing system from the inside of the enclosure. b IP55 degree of protection. b Material: v flat flange: galvanised steel. v sealing gasket: EPDM. Designation Cat. no.
Swing 19 rack coupling kit NSYSFBK19 (1) Back to back association must be shipped individually and combined during on-site installation.
401F_E23120.indd
Dimensions
Cubicles
Dimensions
Profile
DD384437
500 800
Cover panels
Plain or transparent door, lateral panels
D384438
515 815
Fixing to floor
DD384439
500 800
401F_E31010.indd
Dimensions
Cubicles
Dimensions
Gland plates
DD384433 DD384434
500 800
500 800
505
50
Plain door
D 500.
DD384443
605 805
50
Plain door
D 600/800.
401F_E31010.indd
Dimensions
Cubicles
Dimensions
Busbars mounting
Lateral vertical busbars
DD384429
1600 A.
DD384431
2500 A.
DD384430
500
1005 75 75 75 500
2000 A.
DD384432
1305
500
3200 A.
401F_E31010.indd
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper. Publication: Schneider Electric Industries SAS Photos: Schneider Electric Printed: