MIP 6641/009 SERIES MRC A-21R, REF: MIP 6641/009 SERIES MRC,
REF: NSTM 555-33.6.8, REF: MIP 6641/009 SERIES MRC S-3, R-19
(3)
Deck
(4)
Electrical
General Departmental
Safety Officer
Damage Control
Deck
Electrical
General Departmental
Mechanical
(8)
Safety Officer
Damage Control
Deck
Electrical
(6)
Mechanical
(8)
Safety Officer
Combat Systems
Deck
Damage Control
(a)
fittings are not lock-wired with the required tag attached. The
blowers require a "warning" or "caution" sign attached
concerning operation in an explosive atmosphere. The safety
screens are not installed on the red devil blower, and they are
not in good repair. The red devil blowers are not electrically
safety checked annually. REF: The red blowers are in use for
other than DC. (2 Blowers required for DC use only), SSN 688
CLASS SSM,VOL 4, PART 6, CHAPTER 6- PORTABLE EMERGENCY AND
DAMAGE CONTROL EQUIPMENT, SSBN 726 CLASS SSM, VOL 4, PART 6,
CHAPTER 6 -EMERGENCY EQUIPMENT, MIP 3000/029 SERIES MRC A-12,
OPNAVINST 5100.19 (SERIES) ART D0804 A.(2) & B.(8), AEL 2380044060 (Inlet bell w/screen),Part # 5001-3E-678,
NSN 41-01-204-2799 (Duct Bell assembly) Part # 5001-3E-12A, NSN
4140-01-344-5368REF: NSTM 074-21.5 VOL 3, NSTM 512-1.4.7
(b) (S)(R) (B4I0) PMS is not being conducted for
the range guard system installed on the submarine, specifically
the ventilation nozzles above the grill are not being checked.
Recommend removing overhead panel to access ventilation cover
and perform appropriate PMS on these nozzles. There is not at
least 3" of free travel between the cable tube and the ends of
the link assembly. REF: MIP 5556/004 SERIES MRC M-2, S-4R, A-1
(c) (S)(R) (B1B8) PKP extinguisher PMS is not being
conducted IAW applicable MRC's. Not all PKP extinguisher fill
cap seat and gaskets have a light coat of silicone compound
applied. The gaskets are worn and pitting. Recommend conducting
all associated PMS on all PKP extinguishers and replacing all
gaskets. Not all PKP extinguisher brackets contain all rubber
bumpers required. Order open purchase: ANSUL COMPANY (800) 8626785 EXT 3580, P/N BACKFRAME GROMMETS #14089 HANDLE GROMMETS
#8688, MIP 6641/009 SERIES MRC Q-7R, A-18R
(d) (S)(R) (B5I0) PMS on AFFF extinguishers is not
being conducted IAW applicable MRC's. AFFF extinguishers are
under/over charged with solution (Weight of cylinder, Range 27
LBS. 9 OZS.-28 LBS. 4 OZS.) Not all AFFF extinguishers and
brackets are firmly mounted. Not all AFFF brackets contain all
the required rubber bumpers. Order open purchase: AMEREX
(205)655-3217 Bracket Grommets P/N 01990. Not all AFFF
extinguisher weights are being correctly recorded on the record
tag. REF: MIP 6641/009 SERIES MRC A-1R, Q-10R, R-48
(3)
Deck
(a)
Electrical
Mechanical
Safety Officer