CABLES
TRUNK CABLE
PRODUCT INTRODUCTION
HS series coaxial cable was developed to meet the increasing demands of broadband networks. HS series cable has the highest reliability and flexibility of any coaxial cable, low RF attenuation and an unprecedented 10 year warranty. HS Series is optimized for use in broadband feeder plants. It offers lower attenuation than other traditional products, with unmatched flexibility, reliability and cost effectiveness.
TRUNK CABLE
HANSEN
8
CABLES
TRUNK CABLE
CABLE CONSTRUCTIONS
GENERAL STRUCTURE
FLOODED
Flooding Compound
SOLID MESSENGER
TRUNK CABLE
HS-412 SERIES
Inches 0.089 0.362 0.412 0.025 0.475 0.0315
Specifications
Physical Dimensions
Component
Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over Outer Conductor Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness mm 2.26 9.19 10.46 0.64 11.99 0.76
Messenger Versions
Diameter of Steel Messenger 0.109 2.77
Mechanical Characteristics
Maximum Pulling Tension Minimum Breaking Strength Of Messenger 150 lbs. 1800 lbs. 68 kgf 816 kgf
9
Capacitance Impedance Velocity of Propagation Shielding Effectiveness 15.3 1.0 pf/ft 50 3.0 nf/km
Standard Construction
0.089 in.(2.26mm) copper clad aluminum or copper center conductor; gas expanded polyethylene dielectric; continuous aluminum outer conductor; flame retardant polyethylene (PE) jacket. Nominal O.D. 0.475 in. (11.99mm).
HANSEN
Electrical Characteristics
CABLES
6.0 in.
15.2 cm
TRUNK CABLE
HS-500 SERIES
Inches 0.109 0.450 0.500 0.025 0.560 0.030
Specifications
Physical Dimensions
Component
Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over Outer Conductor Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness mm 2.77 11.43 12.70 0.64 14.22 0.76
Messenger Versions
Diameter of Steel Messenger 0.109 2.77
Mechanical Characteristics
Minimum Bending Radius (Jacketed) Maximum Pulling Tension Minimum Breaking Strength Of Messenger 6.0 in. 300 lbs. 1800 lbs. 15.2 cm 136 kgf 816 kgf
HANSEN
10 Electrical Characteristics
Capacitance Impedance Velocity of Propagation Shielding Effectiveness 15.3 1.0 pf/ft 50 3.0 nf/km 75 2 ohms 87% >100dB
CABLES
Standard Construction
0.109 in.(2.77mm) copper clad aluminum or copper center conductor; gas expanded polyethylene dielectric; continuous aluminum outer conductor; flame retardant polyethylene (PE) jacket. Nominal O.D. 0.560 in. (14.22mm).
270 300 325 350 400 450 500 550 600 750 865 1000
TRUNK CABLE
HS-540 SERIES
Inches 0.124 0.514 0.540 0.0135 0.610 0.035
Specifications
Physical Dimensions
Component
Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over Outer Conductor Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness mm 3.15 13.03 13.72 0.343 15.49 0.89
Messenger Versions
Diameter of Steel Messenger 0.109 2.77
Mechanical Characteristics
Minimum Bending Radius (Jacketed) Maximum Pulling Tension Minimum Breaking Strength Of Messenger 4.0 in. 220 lbs. 1800 lbs. 10.2 cm 100 kgf 816 kgf
11
Capacitance Impedance Velocity of Propagation Shielding Effectiveness 15.3 1.0 pf/ft 50 3.0 nf/km
Standard Construction
0.124 in.(3.15mm) copper clad aluminum center conductor; gas expanded polyethylene dielectric; continuous aluminum outer conductor; flame retardant polyethylene (PE) jacket. Nominal O.D. 0.610 in. (15.49mm).
HANSEN
Electrical Characteristics
CABLES
TRUNK CABLE
HS-565 SERIES
Inches 0.129 0.519 0.565 0.023 0.625 0.030
Specifications
Physical Dimensions
Component
Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over Outer Conductor Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness mm 3.28 13.20 14.35 0.58 15.86 0.76
Messenger Versions
Diameter of Steel Messenger 0.109 2.77
Mechanical Characteristics
Minimum Bending Radius (Jacketed) Maximum Pulling Tension Minimum Breaking Strength Of Messenger 5.0 in. 350 lbs. 1800 lbs. 12.7 cm 159 kgf 816 kgf
HANSEN
12 Electrical Characteristics
Capacitance Impedance Velocity of Propagation Shielding Effectiveness 15.3 1.0 pf/ft 50 3.0 nf/km 75 2 ohms 89% >100dB
CABLES
Standard Construction
0.129 in.(3.28mm) copper clad aluminum center conductor; gas expanded polyethylene dielectric; continuous aluminum outer conductor; flame retardant polyethylene (PE) jacket. Nominal O.D. 0.625 in. (15.86mm).
270 300 325 350 400 450 500 550 600 750 865 1000
TRUNK CABLE
HS-625 SERIES
Inches 0.137 0.565 0.625 0.030 0.685 0.030
Specifications
Physical Dimensions
Component
Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over Outer Conductor Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness mm 3.48 14.30 15.88 0.79 17.40 0.76
Standard Construction
0.137 in.(3.48mm) copper clad aluminum center conductor; gas expanded polyethylene dielectric; continuous aluminum outer conductor; flame retardant polyethylene
Messenger Versions
Diameter of Steel Messenger 0.109 2.77
Mechanical Characteristics
Maximum Pulling Tension Minimum Breaking Strength Of Messenger 475 lbs. 1800 lbs. 216 kgf 816 kgf
12 Electrical Characteristics
Capacitance Impedance Velocity of Propagation Shielding Effectiveness 15.3 1.0 pf/ft 50 3.0 nf/km 75 2 ohms 87% >100dB
13
HANSEN
CABLES
7.0 in.
17.8 cm
TRUNK CABLE
HS-715 SERIES
Inches 0.166 0.686 0.715 0.0145 0.785 0.035
Specifications
Physical Dimensions
Component
Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over Outer Conductor Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness mm 4.22 17.42 18.16 0.37 19.94 0.89
Messenger Versions
Diameter of Steel Messenger 0.188 4.78
Mechanical Characteristics
Minimum Bending Radius (Jacketed) Maximum Pulling Tension Minimum Breaking Strength Of Messenger 5.0 in. 340 lbs. 3900 lbs. 12.7 cm 154 kgf 1769kgf
HANSEN
14 Electrical Characteristics
Capacitance Impedance Velocity of Propagation Shielding Effectiveness 15.3 1.0 pf/ft 50 3.0 nf/km 75 2 ohms 88% >100dB
CABLES
Standard Construction
0.166 in.(4.22mm) copper clad aluminum center conductor; gas expanded polyethylene dielectric; continuous aluminum outer conductor; flame retardant polyethylene (PE) jacket. Nominal O.D. 0.785 in. (19.94mm).
270 300 325 350 400 450 500 550 600 750 865 1000
TRUNK CABLE
HS-750 SERIES
Inches 0.167 0.680 0.750 0.035 0.820 0.035
Specifications
Standard Construction
0.167 in.(4.24mm) copper
Physical Dimensions
Component
Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over Outer Conductor Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness mm 4.24 17.27 19.05 0.91 20.83 0.90
clad aluminum center conductor; gas expanded polyethylene dielectric; continuous aluminum outer conductor; flame retardant polyethylene (PE) jacket. Nominal O.D. 0.820 in. (20.83mm).
Messenger Versions
Diameter of Steel Messenger 0.188 4.78
Mechanical Characteristics
Minimum Bending Radius (Jacketed) Maximum Pulling Tension Minimum Breaking Strength Of Messenger 8.0 in. 675 lbs. 20.3 cm 306 kgf
15
Capacitance Impedance Velocity of Propagation Shielding Effectiveness 15.3 1.0 pf/ft 50 3.0 nf/km
HANSEN
Electrical Characteristics
CABLES
TRUNK CABLE
HS-860 SERIES
Inches 0.203 0.828 0.860 0.016 0.960 0.050
Specifications
Physical Dimensions
Component
Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over Outer Conductor Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness mm 5.16 21.03 21.84 0.41 24.38 1.27
Messenger Versions
Diameter of Steel Messenger 0.188 4.78
Mechanical Characteristics
Minimum Bending Radius (Jacketed) Maximum Pulling Tension Minimum Breaking Strength Of Messenger 7.0 in. 450 lbs. 17.8 cm 204kgf
HANSEN
16 Electrical Characteristics
Capacitance Impedance Velocity of Propagation Shielding Effectiveness 15.3 1.0 pf/ft 50 3.0 nf/km 75 2 ohms 88% >100dB
CABLES
Standard Construction
0.203 in.(5.16mm) copper clad aluminum center conductor; gas expanded polyethylene dielectric; continuous aluminum outer conductor; flame retardant polyethylene (PE) jacket. Nominal O.D. 0.960 in. (24.38mm).
270 300 325 350 400 450 500 550 600 750 865 1000
HANSEN
CABLES