PHYSICAL PROPERTIES
APPLICATION
Formulated for standard and fine pitch printing through stencil apertures as small as 0.18 mm (0.3mm pitch) at a print speed of between 10mm/sec and 200mm/sec. ALPHA UP-78-T is especially suitable for ultra fine pitch applications when used in conjunction with Alpha Metals laser cut stencils. Minimum stencil aspect ratio should be 1.3:1 (minimum aperture width / stencil thickness) for sharp, well-defined print definitions. Suitable application methods include: Squeegee Printing, MPM RheoPump and DEK ProFlow.
SAFETY
While the ALPHA UP-78-T flux system is not considered toxic, its use in typical reflow will generate a small amount of reaction and decomposition vapors. These vapors should be adequately exhausted from the work area. Consult the MSDS for additional safety information, and for toxicity data on alloys containing lead and silver.
STORAGE
ALPHA UP78-T should be stored in a refrigerator upon receipt at 0 - 10C (32 - 50F). This will be sufficient to maintain a nominal shelf life of six months. ALPHA UP-78-T should be permitted to reach room temperature before unsealing its package prior to use.
TECHNICAL SUPPORT
For enquiries, assistance and support contact Technical Services, Alpha Metals UK. Telephone: 0181 665 6666 Facsimile: 0181 665 473
The information contained herein is based on data considered accurate and is offered at no charge. No warranty is expressed or implied regarding the accuracy of this data. Liability is expressly disclaimed for any loss or injury arising out of the use of this information or the use of any materials designated. Rev. 6/4/08
RESULTS
PROCEDURES/REMARKS
PHYSICAL PROPERTIES Thixotropic Index Paste Colour and Specific Gravity Reflowed Residue Tack Force Viscosity Stencil Life Slump 0.74 Grey - 4.9g/cc Clear, colourless - tack free after reflow. 5.5% w/w. 1.8g/cm2 125 g.f @ 0hrs, 101 g.f @ 24Hrs Viscosity is suitable for all typical stencil-printing applications. > 24 hours Suitable for fine-pitch stencil printing. No bridging @ 200 micron gap JIS-Z-3284
J-Std 005. JIS Z3284. Malcom Spiral Viscometer. ICP-029 50%RH, 25oC J-Std 005 JIS - Z 3284
Although designed as a no-clean flux system, the residue may be cleaned with: SC1080 SC22 25% Solution SC30 BIOACT EC-7 BIOACT EC7-R 10% Alpha 2110 Stencils can be cleaned with Alpha SC-10 stencil cleaner.
The information contained herein is based on data considered accurate and is offered at no charge. No warranty is expressed or implied regarding the accuracy of this data. Liability is expressly disclaimed for any loss or injury arising out of the use of this information or the use of any materials designated. 6-4-08
Temperature (Celcius)
200
150
100
50
Time (Seconds)
UP78-T Competito
0
-1
24
Time (Hours)
-2 -3
The information contained herein is based on data considered accurate and is offered at no charge. No warranty is expressed or implied regarding the accuracy of this data. Liability is expressly disclaimed for any loss or injury arising out of the use of this information or the use of any materials designated. 6-4-08