Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Morin Series S Actuator

Stainless Steel Spring Return and Double Acting


Pneumatic Quarter-turn Actuators
Output Torques to 240,000 lb.in.
Features and Benefits
Innovative stainless steel construction
as standard provides superior
corrosion resistance both internally
and externally.
Scotch yoke design using precision
bearings eliminates dead band in
the yoke mechanism, providing the
greatest torque output at the
beginning and end of stroke.
Heat-treated stainless steel thrust pin
and rollers transfer piston force to
17-4PH stainless steel yoke by rolling
to reduce friction, for longer life and
more efficient torque transmission.
Bi-directional travel stops provide
accurate valve rotation adjustment.
Teflon piston bearings, piston rod
bushings and output shaft bushings
provide longer life, reduce
maintenance, and require no
lubrication.
Universal design position indicator
and pointer allows for either parallel
or perpendicular mounting.
Stainless steel construction allows
proximity switches to be directmounted in the actuator housing,
eliminating the need to mount bracket
and cam assemblies on top of the
actuator.
NAMUR drive slot allows mounting of
accessories closer to the actuator,
resulting in a more compact, precise
assembly, and eliminates the need for
coupling.
Spring return model design requires
no special tools to safely and easily
disarm the spring in the field,
reducing down time and providing a
man safe spring.

General Applications

Technical Data

For remote control of any quarter-turn


application: ball, butterfly, rotary plug or
damper style valves, etc. To be used in
chemical process, food and beverage,
iron and steel, off-shore marine,
pharmaceutical, power, oil and gas,
pulp and paper, and textile industries.

Supply pressure:

40 to 160 psig
(see torque chart,
MORMC-0333)

Supply medium:

Air or any gas


compatible with
materials of
construction

Temperature rating
Standard range:
Optional range:
Angular rotation:

Flow Control

-20F to 210F
-65F to 300F
90 degrees
8 degrees

Morin is either a trademark or registered trademark of Tyco International Services AG or its affiliates in the
United States and/or other countries. All other brand names, product names, or trademarks belong to
their respective holders.
Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024-US-1202

Morin Series S Actuator

Morin has a Heart of Stainless Steel


Morin Stainless Steel Yoke
The heart of any scotch yoke actuator is the yoke. Morin uses 17-4PH
stainless for this critical area as standard.
The yoke is the mechanism used to convert linear force to torque. This
area is most often where the life of the actuator is controlled.

Principles of Construction
Using high quality materials of construction and modern
rugged design concepts Morin becomes the standard for
low cost valve actuation while providing high quality
performance.
The S actuator housings are all machined from 316
stainless steel castings. This produces a rugged, low cost
product through reduced machining time and by eliminating
wasteful excess material.
Any components that rotate or slide during operation, such
as the high strength stainless steel output shaft, stainless
steel piston rod, stainless steel thrust pin or the stainless
steel piston, are all supported by replaceable friction
reducing bearings.

Bi-directional Travel Stops


Adjustable stops on each end cap
provide the flexibility of accurate valve
rotation positioning at the end of the
open and close stroke. Both stops
are located on the cylinder centerline,
the optimal position to maximize
travel adjustment and eliminate any
detrimental side loading on the travel
stops. Adjustable from 82 to 98.

Ingress Protection
Actuator meets IP66 and IP67 for
standard units.

Spring Designed for Safety


All spring return models incorporate a
man-safe spring design that allows the
actuator to be safely assembled and
disassembled in the field without the
need for special tools. The integral tie
rods are bored and tapped to provide a
means of loading and unloading the
spring in a safe and convenient manner.

Scotch Yoke Torque Characteristics


Available Options
Double Acting Air to Air

Single Acting Spring Return


125
Air
Break

Hydraulic Override

Spring
Break

Break Torque

Full Stroke Adjustment

100

100
Air
Stroke

Spring
Stroke

Proximity Preparation

75

Lockout Device

75

Torque

Torque

Jackscrew Override

125

50
Spring
End

25

Air
End

45

Partial Stroke Test

Running
Torque

50

25

90

Stroke

Copyright 2012 Tyco Flow Control. All rights reserved.

45

90

Stroke

MORMC-0024
2

Morin Series S Actuator

Materials of Construction
Double Acting Models 003 to 100 and 144 (Except Model 135)

Bearings
Teflon Composite

Scotch Yoke
17-4PH Stainless Steel with
440C Roller Bearings

Housing and End Caps


316 Stainless Steel

Piston
316 Stainless Steel

Piston Bearing
Teflon

Piston Rod Bearings


Teflon or Bronze
(depending on Model)

Cylinders
316 Stainless Steel

Double Acting Models 135 to 1150 (Except Model 144)

Bearings
Teflon Composite

Scotch Yoke
17-4PH Stainless Steel with
440C Roller Bearings

Housing and End Caps


316 Stainless Steel

Piston
316 Stainless Steel

Piston Bearing
Teflon

Piston Rod Bearings


Teflon or Bronze
(depending on Model)

Copyright 2012 Tyco Flow Control. All rights reserved.

Cylinders
316 Stainless Steel

MORMC-0024
3

Morin Series S Actuator

Manual Options
To provide the actuation package best suited for your application, the Morin line offers a full range
of manual accessories.

Partial Stroke Test Device


(PSTD)

Lockout

Jackscrew Override (JSO)

Integral lockout allows safe


shutdowns for maintenance and
isolation of systems.

Manual operation when power is


lost. Simple and effective.

Hydraulic Override (MHP)

AWWA

Manual operation when power is


lost. Includes speed controls.

Tested per American Waterworks


Association C504. Available for
pneumatic or water service
operation.

Direct Mounting Cast


Adapters

Provides a method of testing


ESD packages without
shutdown.

Many valve top works covered,


including some ISO mounting.
Assures economic but correct
mounting alignment.

+ F/C

Full Stroke Adjuster


Provides mechanical control of
maximum and/or minimum valve
stroke.

Proximity Switch
Preparation

High or Low Temperature


Ratings

Allows installation of cartridge


style proximity switches. Leaves
top works open for mounting of
other devices.

Standard rating of -20F to 210F


[-29C to 99C] covers most
applications. Optional ratings
down to -65F [-54C] and up to
300F [149C].

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
4

Morin Series S Actuator

Mechanical Data
Notes:

Mechanical Data

1. Air Consumption:
Cubic inches shown in chart represent
actual free air volume in cylinder between
piston and end cap when furthest apart. Air
consumption will vary depending on supply
pressure. To determine standard cubic feet
per minute use the following formula:

(_____ )(________________)(
Vol. in3

Supply Air psig + 14.7

1728

14.7

Strokes/Minute

Example: Calculate SCFM for Model 023


double acting using 80 psig air supply and
5 strokes/minute.

Actuator
Model

Number
of
Pistons

Cylinder
Bore
(inch)

Stroke
(inch)

Volume1
Cubic In
90 Stroke

Cycle Time2
Seconds
90 Stroke

003

2.250

1.5

0.3

006
012

1
2

2.750
2.750

2
2

12
23

0.5
0.7

10
12

023
036

1
1

4.375
5.438

3
3

45
70

1.0
1.5

27
30

050
072

1
2

6.250
5.438

3
3

92
137

2.2
2.5

36
37

100
135

2
1

6.250
8.250

3
5

182
267

3.0
4.5

46
165

144
210

4
1

5.438
10.250

3
5

274
413

3.5
5.0

74
185

270
370

2
1

8.250
12.250

5
6

526
707

6.0
8.0

210
390

420
575

2
1

10.250
15.500

5
6

816
1132

8.5
9.5

257
519

740
1150

2
2

12.250
15.500

6
6

1395
2245

10.0
12.0

530
775

1480
2380

2
2

12.250
15.500

12
12

2744
4444

20.0
24.0

850
1050

003
006

1
1

2.250
2.750

1.5
2

6
12

0.3
0.5

6
11

012
023

2
1

2.750
4.375

2
3

23
45

0.7
1.0

14
34

036
046

1
2

5.438
4.375

3
3

70
88

1.5
2.0

42
43

072
100

2
2

5.438
6.250

3
3

137
182

2.5
3.0

55
64

135
144

1
4

8.250
5.438

5
3

267
274

4.5
3.5

210
110

210
270

1
2

10.250
8.250

5
5

413
526

5.0
6.0

235
250

370
420

1
2

12.250
10.250

6
5

707
816

8.0
8.5

540
379

575
740

1
2

15.550
12.250

6
6

1132
1395

9.5
10.0

779
704

1150
1480

2
2

15.550
12.250

6
12

2245
2744

12.0
20.0

1082
1650

2380

15.500

12

4444

24.0

1850

Weight
(lbs.)

Double Acting

SCFM =

( )(
45
_____
1728

)( )

80 +14.7
_________
14.7

SCFM = 0.84

2. Cycle times shown represent average time


to stroke 90 degrees using standard pilot
valves and should be used as a guide only.
Cycle times can be increased or decreased
dramatically by using speed controls,
oversized pilot valves or quick exhaust
valves.

Spring Return

Typical Section
Double Acting/One Piston

Typical Section
Spring Return/Two Pistons

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
5

Morin Series S Actuator

Scotch Yoke Mechanics

Stroke in degrees
-5

10

15 20 25 30 35 40 45 5055 60 65 70 75 80 85

90

95

Piston rod stroke


A

Moment arm
minimum (X)
at mid stroke (45)

Y
Moment arm
maximum (Y) at end
of stroke (90)

Normal 90 stroke
X = Min. moment arm
Y = Max. moment arm

Conclusion: Greatest Torque Output is at


Beginning and End of Stroke-Where its Needed!

100 stroke

For max. moment arm at any stroke position multiply min. moment by secant

Output Torques
Output Torques (lb. in.) Double Acting air to air
Actuator
Model

40

50

60

70

80

Air Supply (psig)


90
100
110

120

130

140

150

160

003

Start / End
Minimum

173
110

219
140

259
165

305
190

345
220

391
250

431
280

472
310

518
330

006

Start / End
Minimum

300
235

375
290

450
350

525
405

600
460

675
520

750
575

825
640

900
690

975
750

1050
810

1125
870

1200
940

012

Start / End
Minimum

690
470

863
580

1035
700

1208
810

1380
940

1553
1050

1725
1170

1898
1275

2070
1405

023

Start / End
Minimum

1150
855

1450
1070

1725
1285

2010
1500

2300
1710

2585
1925

2875
2140

3160
2350

3450
2570

3740
2780

4020
3000

4300
3210

4600
3420

036

Start / End
Minimum

1980
1370

2475
1710

2970
2055

3465
2400

3960
2740

4455
3080

4950
3425

5445
3770

5940
4110

6435
4450

6930
4800

7425
5140

7920
5480

050

Start / End
Minimum

2500
1840

3125
2300

3750
2760

4375
3220

5000
3680

5630
4140

6250
4600

6875
5060

7500
5520

8125
5980

8750
6440

9375
6900

10000
7360

072

Start / End
Minimum

3960
2740

4950
3425

5940
4110

6930
4790

7920
5480

8910
6160

9900
6850

10780
7540

11880
8220

100

Start / End
Minimum

5000
3680

6250
4600

7500
5520

8750
6440

10000
7360

135

Start / End
Minimum

7088
5250

8862
6565

10631
7875

12406
9185

14175
10500

15950
11810

17724
13125

19488
14440

21263
15750

144

Start / End
Minimum

7200
5460

9000
6850

10800
8210

12600
9580

14400
10960

210

Start / End
Minimum

11550
8160

14438
10200

17325
12240

20213
14280

23100
16320

25988
18360

28875
20400

31763
22440

34650
24480

37538
26520

270

Start / End
Minimum

14175
10500

17719
13125

21263
15750

24806
18375

28350
21000

31894
23625

35438
26250

38981
28875

42525
31500

370

Start / End
Minimum

19795
13080

24744
16350

29693
19620

34641
22890

39590
26160

44539
29430

49488
32700

54436
35970

59385
39240

420

Start / End
Minimum

21000
16320

26250
20400

31500
24480

36750
28560

42000
32640

575

Start / End
Minimum

31913
22440

39849
28050

47869
33660

55833
39270

63825
44880

71806
50490

79781
56100

87757
61710

740

Start / End
Minimum

38850
26160

48563
32700

58275
39240

67988
45780

77700
52320

87413
58860

97125
65400

106838
71940

1150

Start / End
Minimum

60375
44880

75469
56100

90563
67320

105656
78540

120750
89760

1480

Start / End
Minimum

74000
46621

92500
58276

111000
69931

129500
81586

148000
93242

166500
104897

2380

Start / End
Minimum

119000
75506

148750
94383

178500
113259

208250
132136

238000
151013

185000
116552

See www.morinact.com for complete torque book.

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
6

MAXIMUM OPERATING
PRESSURE = 120 psi

MAXIMUM OPERATING
PRESSURE = 100 psi

203500
128207

23037
17060

24812
18375

222000
139862

28350
21000

MAXIMUM OPERATING
PRESSURE = 120 psi
40425
28560

43313
30600

46200
32640

64334
42510

69283
45780

74231
49050

79180
52320

95738 103718 111694


67320 72930 78540
116550
78480

26576
19690

119669 127650
84150 89760

MAXIMUM OPERATING
PRESSURE = 120 psi
MAXIMUM OPERATING
PRESSURE = 120 psi
MAXIMUM OPERATING
PRESSURE = 120 psi
MAXIMUM OPERATING
PRESSURE = 120 psi

Morin Series S Actuator

Output Torques
Output Torques (lb. in.) Single Acting spring return
Actuator
Model

003

006

012

023

036

046

072

100

135

144

210

270

370

420

575

740

1150

1480

2380

Air Supply (psig)


90
100
110

40

50

60

70

80

120

130

140

150

160

Start
Minimum
End
Start
Minimum
End

110
50
55
195
99
110

135
63
70
245
123
137

160
72
80
290
151
168

185
86
95
340
175
194

210
95
105
390
199
221

Start
Minimum
End
Start
Minimum
End

390
208
231
750
360
400

485
263
292
945
459
510

585
312
347
1125
540
600

680
366
407
1305
635
705

780
416
462
1500
720
800

1680
815
905

1870
905
1005

2250
1080
1200

2615
1269
1410

3000
1440
1600

Start
Minimum
End
Start
Minimum
End

1170
567
630
1500
720
800

1460
711
790
1870
905
1005

1755
855
950
2250
1080
1200

2050
990
1100
2615
1269
1410

2340
1134
1260
3000
1440
1600

2630
1274
1415

2925
1418
1575

3510
1701
1890

3880
1880
2090

4095
1985
2205

4700
2250
2500

Start
Minimum
End
Start
Minimum
End

2340
1134
1260
3250
1575
1750

2925
1418
1575
4060
1971
2190

3510
1701
1890
4880
2358
2620

4095
1985
2205
5690
2754
3060

4700
2250
2500
6500
3150
3500

Start
Minimum
End
Start
Minimum
End

4390
2554
2838
4680
2268
2520

5485
3186
3540
5850
2835
3150

6580
3829
4254
7020
3402
3780

7680
4466
4962
8190
3969
4410

8775
5103
5670
9400
4500
5000

9875
5740
6378

10970
6377
7086

13160
7657
8508

15355
8932
9924

17550
10206
11340

Start
Minimum
End
Start
Minimum
End

6825
3639
4043
8780
4683
5203

8530
4544
5049
10970
5846
6496

10240
5455
6061
13160
7019
7799

11940
6366
7073
15355
8187
9097

13650
7277
8085
17550
9356
10395

15350
8187
9097
19746
10524
11693

17060
9098
10109
21940
11693
12992

20475
10915
12128

23890
12731
14146

27300
14553
16170

Start
Minimum
End
Start
Minimum
End

12025
6701
7446
13650
6946
7718

15030
9403
10448
17060
8685
9650

18040
10050
11167
20475
10418
11576

21045
11727
13030
23890
12153
13503

24050
13404
14893
27300
13892
15435

27055
15080
16756
30705
15630
17367

30060
16757
18619
34120
17369
19299

36075
20105
22339

42090
23453
26059

48100
26807
29785

Start
Minimum
End
Start
Minimum
End

18690
9507
10563
24050
13404
14893

23360
11888
13209
30060
16757
18619

28030
14261
15845
36075
20105
22339

32700
16642
18491
42090
23453
26059

37375
19018
21131
48100
26807
29785

42045
21390
23767
54108
30163
33514

46720
23767
26408
60120
33514
37238

56060
28530
31700

65400
33283
36981

74750
38037
42263

Start
Minimum
End
Start
Minimum
End

37375
19018
21131
48100
23310
25900

46720
23767
26408
60125
29138
32375

56060
28530
31700
72150
34965
38850

65400
33283
36981
84175
40712
45235

74750
84090
38037
42790
42263
47544
96200 108225
46620
52448
51800
58275

93440
47534
52815
120250
58275
64750

Start
Minimum
End

77350
37485
41650

96688
46857
52063

116025 135363
56228 65599
62475 72888

154700 174038
74970
84342
83300
93713

193375
93713
104125

MAXIMUM OPERATING
PRESSURE = 100 psi
MAXIMUM OPERATING
PRESSURE = 100 psi

Copyright 2012 Tyco Flow Control. All rights reserved.

MAXIMUM OPERATING
PRESSURE = 120 psi

MAXIMUM OPERATING
PRESSURE = 120 psi
MAXIMUM OPERATING
PRESSURE = 120 psi
MAXIMUM OPERATING
PRESSURE = 120 psi
MAXIMUM OPERATING
PRESSURE = 120 psi

MORMC-0024
7

Morin Series S Actuator

Dimensions
Models 012, 046, 072, 100 and 144*

Q Typical

A
B

C 1 (sq)

C 2 (sq)

Boss for Proximity


Switch Option

P NPT Typical

H
Diameter
E

Models 003, 006, 023, 036 and 050


Q Typical

D
B

316 SS

J
C 1 (sq)

F (dia)

K
L

Boss for Proximity


Switch Option
(excluding Model 003)

G
P NPT Typical
H
Diameter

Notes: 1. Shown without pointer for clarity.


2. For mounting dimensions, refer to pages 12 and 13.
* Model 144 consists of two model 072 actuators connected by a single
drive shaft. Request drawing A-5037 for more detailed information.

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
8

Morin Series S Actuator

Dimensions (inches), Double Acting


Model

C1

C2

003DA

9.06

3.50

2.69

3.06

0.75

1.00

1.37

2.75

3.25

1.00

1/8

0.62

006DA

12.34

5.97

3.18

3.91

1.00

0.10

1.38

1.50

3.00

4.75

1.31

1/8

1.00

012DA

12.74

6.37

3.18

3.18

3.91

4.81

0.10

1.38

1.50

3.00

4.75

1.31

1/8

1.00

023DA

18.60

8.81

4.81

5.78

1.43

0.25

1.75

2.16

4.31

6.69

1.88

1/4

1.15
1.25

036DA

18.48

8.81

5.81

6.28

1.43

0.75

1.75

2.16

4.31

6.69

1.88

1/4

050DA

18.49

8.81

7.13

6.94

1.43

1.41

1.75

2.16

4.31

6.69

1.88

1/4

1.25

072DA

19.33

9.67

5.81

5.81

6.28

6.38

0.75

1.75

2.16

4.31

6.69

1.88

1/4

0.83

100DA

19.35

9.68

7.12

7.12

6.94

6.38

1.41

1.75

2.16

4.31

6.69

1.88

1/4

0.75

144DA

19.33

9.67

5.81

5.81

6.28

6.38

0.75

1.75

5.05

10.10

12.49

1.88

1/4

0.875

Dimensions (inches), Spring Return


Model

C1

C2

003SR

9.06

3.50

2.69

3.06

0.75

1.00

1.37

2.75

3.25

1.00

1/8

0.62

006SR

14.44

5.97

3.18

3.91

1.00

0.10

1.38

1.50

3.00

4.75

1.31

1/8

1.00

012SR

14.84

6.37

3.18

3.18

3.91

4.55

0.10

1.38

1.50

3.00

4.75

1.31

1/8

1.00

023SR

21.82

8.81

4.81

5.78

1.43

0.25

1.75

2.16

4.31

6.69

1.88

1/4

1.25

036SR

23.51

8.81

5.81

6.28

1.43

0.75

1.75

2.16

4.31

6.69

1.88

1/4

1.25

046SR

22.80

9.79

4.81

4.81

5.93

6.24

0.25

1.75

2.16

4.31

6.69

1.88

1/4

1.25

072SR

24.37

9.67

5.81

5.81

6.28

5.99

0.75

1.75

2.16

4.31

6.69

1.88

1/4

1.25
1.25
1.25

100SR

24.38

9.68

7.12

7.12

6.94

5.99

1.41

1.75

2.16

4.31

6.69

1.88

1/4

144SR

24.37

9.67

5.81

5.81

6.28

5.99

0.75

1.75

5.05

10.10

12.49

1.88

1/4

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
9

Morin Series S Actuator

Dimensions
Models 270, 420, 740, and 1150
A
B

Q Typical

C
G
P NPT Typical
H
Diameter
E

Models 135, 210, 370 and 575


D
A

Q Typical

B
J
K

F Diameter

G
P NPT Typical
H
Diameter

Models 1480 and 2380

D
B

Q Typical

J
K

G
E

Notes: 1. Shown without pointer for clarity.


2. For mounting dimensions, refer to pages 12 and 13.

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
10

P NPT Typical

Morin Series S Actuator

Dimensions (inches), Double Acting


C

Model

135DA

32.87

15.88

9.50

10.44

2.75

1.00

4.38

8.13

11.82

3.19

3/8

1.50

210DA

33.26

15.88

11.50

11.44

2.75

2.00

4.38

8.13

11.82

3.19

1/2

2.00
1.50

270DA

33.99

16.99

9.50

10.44

11.72

1.00

4.38

8.13

11.82

3.19

3/8

370DA

41.64

19.75

13.50

16.75

3.50

2.69

6.00

5.44

9.50

14.81

6.88

1/2

1.50

420DA

34.75

17.38

11.50

11.44

11.22

2.00

4.38

8.13

11.82

3.19

1/2

1.75

575DA

42.42

19.75

17.00

18.50

3.50

4.50

6.00

5.44

9.50

14.81

6.88

3/4

2.00

740DA

44.15

20.07

13.50

16.75

15.50

2.69

6.00

5.44

9.50

14.81

6.88

1/2

1.50
1.85

1150DA

45.39

22.69

17.00

18.50

14.88

4.50

6.00

5.44

9.50

14.81

6.88

3/4

1480DA

70.65

35.85

13.50

21.57

26.94

0.44

7.06

13.38

7.58

1/2

2.15

2380DA

88.29

36.51

17.00

22.08

25.06

2.19

7.06

13.38

7.58

3/4

2.50

Q
1.75

Dimensions (inches), Spring Return


Model

135SR

39.46

15.88

9.50

10.44

2.75

1.00

4.38

8.13

11.82

3.19

3/8

210SR

42.67

15.88

11.50

11.44

2.75

2.00

4.38

8.13

11.82

3.19

1/2

2.12

270SR

40.57

16.99

9.50

10.44

10.95

1.00

4.38

8.13

11.82

3.19

3/8

1.75

370SR

52.00

19.75

13.50

16.75

3.50

2.69

6.00

5.44

9.50

14.81

6.88

1/2

1.75

420SR

44.17

17.38

11.50

11.44

10.36

2.00

4.38

8.13

11.82

3.19

1/2

2.12

575SR

54.25

19.75

17.00

18.50

3.50

4.50

6.00

5.44

9.50

14.81

6.88

3/4

2.50
2.12

740SR

53.96

22.07

13.50

16.75

14.75

2.69

6.00

5.44

9.50

14.81

6.88

1/2

1150SR

57.25

22.69

17.00

18.50

13.75

4.44

6.00

5.44

9.50

14.81

6.88

3/4

2.50

1480SR

86.98

35.85

13.50

21.57

26.30

0.44

7.06

13.38

7.58

1/2

2.50

2380SR

88.29

36.51

17.00

22.08

25.10

2.19

7.06

13.38

7.58

3/4

2.50

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
11

Morin Series S Actuator

Mounting Details
Model 003 Top and bottom of housing (symmetrical)
1/4

- 20 UNC Tap x 0.50 Deep


on 1.500 sq. Bolt Pattern

7/16

0.44

Typ.
SYM.

0.438 square
0.435

0.157/0.160 wide
0.197/0.205 deep
Drive Slot

A
Section A - A

Models 006 to 100 and 144 Top and bottom of housing (symmetrical)
Models 006 and 012 = 0.87
Models 023 to 100 = 1.18

Models 006 and 012 = 0.746/0.743


Models 023 to 100 = 0.998/0.995

Models 006 and 012 = 5/16 - 18 UNC


Tap x 0.37 Deep on 2.000 sq. Bolt Pattern
Models 023 to 100 = 3/8 - 16 UNC
Tap x 0.37 Deep on 3.000 sq. Bolt Pattern

1.00 typ.
SYM.

0.157/0.160 wide
0.197/0.205 deep
Drive Slot

NAMUR Drive
Both Ends
B
Section B - B

Models 135, 210, 270 and 420 Bottom of housing ISO 5211-F16
3/4

2.000/1.994 Diameter Shaft


1/2 sq. x 3.19 Long Keyway
with 0.031 radius inside key way corners
(to be used with 1/2" x 3 3/16" key)

- 10 UNC Tap x 1.18" Deep


(4) Places as Shown on
6.500 Diameter Bolt Circle

1.18

C
Section C - C

Models 135, 210, 270 and 420 Top of housing - Mounting details
0.251 CBore x 0.209 Deep
M6 Tap x 1/2" Deep

TUHS

M5 x 0.80 Tap x 3/8" Deep


(4) Places on NAMUR Pattern
1.181" x 3.149" Rectangle

NEPO

NEPO

NAMUR Adapter

SHUT

0.998/0.995
square

0.197
0.205
1.18

0.157/0.160 wide x 0.197/0.205 Deep


NAMUR Accessory Drive Slot

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
12

3.69

Morin Series S Actuator

Mounting Details
Models 370, 575, 740 and 1150 Bottom of housing ISO 5211-F30
3.000/2.994 Diameter Shaft
3/4 sq. x 3.75 Long Keyway
with 0.031 radius inside key way corners
(to be used with 3/4" x 3 13/16" key)

3/4

- 10 UNC Tap x 1.18" Deep


(8) Places as Shown on
11.73 Diameter Bolt Circle

5.31
1.18

4.56

22.5 Typ.

D
Section D - D

Models 370, 575, 740 and 1150 Top of housing Mounting details
0.251 CBore x 0.209 Deep
M6 Tap x 1/2" Deep

SHUT

NAMUR Adapter
OPEN

OPEN

M5 x 0.80 Tap x 3/8" Deep


(4) Places on NAMUR Pattern
1.181 x 5.118 Rectangle

0.197
0.205
SHUT

0.998/0.995 square

1.18

0.157/0.160 wide x 0.197/0.205 Deep


NAMUR Accessory Drive Slot

Models 1480 and 2380 Bottom of housing ISO 5211-F35


45
Female Drive
6.250 Dia. Bore x 11" Deep
1.501 Rectangular Keyway with
0.12 Radius Inside Keyway Corners
use 11/2" x 1" Rectangle Key

E
1 - 8 UNC Tap x 13/4" Deep
(8) Places as Shown on
14.02 Diameter Bolt Circle

1.18

22.5
Typ.
E
Section E - E

Models 1480 and 2380 Top of housing Mounting details


0.251 CBore x 0.209 Deep
M6 Tap x 1/2" Deep

M5 x 0.80 Tap 3/8" Deep


(4) Places on NAMUR Pattern
1.181" x 3.149" Rectangle

NAMUR Adapter

0.996/0.993
square

0.197
0.205
1.18

0.157/0.160 Wide x 0.197/0.205 Deep


NAMUR Accessory Drive Slot

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
13

Morin Series S Actuator

Model Numbering
S

- 270

00

- JSO

Actuator Model
S Stainless Steel

Actuator Size
Model code based on approx. torque
symmetrical double acting at 80 psig
003
072
575
006
100
740
012
135
1150
023
210
1480
036
270
2380
046
370
050
420

Interface Bolting
U UNC Mounting Threads
M Metric Mounting Threads

Function
D Double Acting
S Spring Return

Configurations
Spring code denotes air pressure divided by 10 where spring force gives
the same spring end torque as air end torque using symmetric yoke.
00 No spring (double acting)
04 40 pound spring
05 50 pound spring
06 60 pound spring
Etc. See Morin Torque Book (MORMC-0333) for available springs

Spring Return Failure Rotation


0 No spring (double acting OR actuator rotates clockwise on loss of air)
1 Actuator rotates counterclockwise on loss of air

Option
(blank) No options (standard configuration)
Note: Some codes can be used in combination. Indicate by stacking " separated by "-".
Consult your sales representative for possible combinations.

How To Order
1. Double Acting example:
Air supply: 80 psig
Break torque: 7,200 lb.in.
S-072U-D000
S:
Series
072:
Model number
U:
UNC mounting threads
D000:
Double acting

2. Spring Return example:


Air supply: 80 psig
Ending torque: 12,950 lb.in.
Fail rotation: Clockwise
S-370U-S080
S:
Series
370:
Model number
U:
UNC mounting threads
S080:
Spring set

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
14

3. For all spring return models:


Use air pressure to determine
spring set.
All spring sets ending with 0 fail
clockwise (40, 50, 60, etc.).
All spring sets ending with 1 fail
counterclockwise (41, 51, 61, etc.).

Morin Series S Actuator

Westlock Controls Accessories


Stainless Steel Control Monitors and Transmitters*
Touch set cams in all control monitors are hand adjustable, spring loaded and self-locking
providing quick calibration of position sensors. Terminal strips are pre-wired and color
coded with generous working space for ease of use and extra wiring points for solenoid
integration. All units are standard with multiple conduits for easy field wiring and accessory
mounting. All AccuTrak and Quantum products utilize common bolt pattern for
mounting to actuators and can be supplied with mounting hardware as needed. Low
copper content aluminum enclosures (0.2% maximum copper content) insure robust
performance in corrosive environments. Control transmitters utilize non-contact Hall Effect
sensing technology and digital position transmission via 4-20 mA signal. Transmitters are
available with both HART and FOUNDATION Fieldbus digital communication protocols.

AccuTrak/Quantum 366

Digital EPIC D470

Digital EPIC D450

Network Solutions*
Intellis is a family of industrial control field Network Control Monitors which use embedded
control systems to automate valves and link field I/O to the host PLC or DCS. Each monitor
is assigned a unique address and accepts input/output signals from valve position
sensors, solenoids and external alarm and control devices. Hall Effect sensors are utilized
for valve position monitoring. Low-power Falcon solenoid valve provides integrated
actuation control. Network interface modules Pacs allow communication via a protocol of
choice. Westlock Intellis Network Control Monitors are available for linear or rotary
applications in all area classifications.

Intellis Control Monitor

Notes:

Stainless Steel, AccuTrak, Quantum, Intellis Network Solutions and Positioners * please
consult your sales representative for the availability of global certifications such
as ATEX, IEC, GOST, CSA and InMetro for specific configurations in these product lines,
as approvals may vary.

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
15

Morin Series S Actuator

Also Available
The Series B and C Actuators
Ductile Iron

Setting a new standard in actuation at


a price youd expect from a commodity
product.

316 Stainless Steel (Series B)


Carbon Steel (Series C)

Up To 160 psig max operating pressure


(see torque chart, MORMC-0333).

Double acting break torques to


1,400,000 lb.in.
Spring end torques to 583,288 lb.in.
For additional information, refer to
datasheet MORMC-0023.

Teflon
Chrome-plated Steel
17-4PH Stainless Steel
or Ductile Iron
Sintered Bronze
or Teflon composite

The Series HP Actuator


High pressure actuation with carbon steel
cylinders for superior corrosion resistance.
Up To 2250 psi max operating pressure
(see torque chart, MORMC-0333).
Double acting torques to 800,000 lb.in.
Spring end torques to 400,000 lb.in.
For additional information, refer to
datasheet MORMC-0072.

Tyco Flow Control (TFC) provides the information herein in good faith but makes no representation as to its comprehensiveness or accuracy. This data sheet is intended only as a guide to TFC products and services.
Individuals using this data sheet must exercise their independent judgment in evaluating product selection and determining product appropriateness for their particular purpose and system requirements. TFC MAKES NO
REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO
THE INFORMATION SET FORTH HEREIN OR THE PRODUCT(S) TO WHICH THE INFORMATION REFERS. ACCORDINGLY, TFC WILL NOT BE RESPONSIBLE FOR DAMAGES (OF ANY KIND OR NATURE, INCLUDING
INCIDENTAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES) RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. All Patents and Patents Pending in the U.S. and foreign countries are
property of their respective owners. Tyco reserves the right to change product designs and specifications without notice. All registered trademarks are the property of their respective owners. Printed in the USA.

Copyright 2012 Tyco Flow Control. All rights reserved.

MORMC-0024
16