Professional Documents
Culture Documents
Fire Service Valves Catalogue
Fire Service Valves Catalogue
This catalogue has been compiled with greatest care and we have endeavored to provide information as
accurate as possible. However Econosto Mideast b.v cannot be held responsible for any possible errors,
omissions and inaccurate / incomplete information as a result of further developments / changes and no
rights may be derived from its content. Data given in this catalogue may be changed without notice.
The sizes and weights in this catalogue are published with all rights reserved. We reserve the right to make
adjustments to these data for technical and economical reasons and also due to Econosto’s continuing
program of product improvement. Every data change will be incorporated in the next revision of this
catalogue. You can get information about the changes in data from the sales department of Econosto or the
local distributor in your area.
Copyright : No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in
any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior
written permission of the publisher.
EME/F/V/12/00
Section Overview / Figure Number Overview
Section Page
Company Profile 03
Certificates 07
Gate Valves 11
Check Valves 20
Y Strainers 24
Butterfly Valves 27
Alarm Check Valves 34
Deluge Valves 42
Pressure Gauge 63
Water Spray Nozzle 64
Flange Tables 70
Figure Page
GVOSY E 200 12
GVOSY E 250 13
GVOSY E 300 F 14
GVNRS E 200 15
GVNRS E 250 16
GVNRS E 300 F 17
IP888 E 18
WP999 E 19
ECONCHECK F 21
DDCV E 22
ECONCHECK G 23
YS-F-1161 EF 25
YS-G-1251 EG 26
DG 28
HPG 29
DW 30
HPW 31
Econfly G 32
Econfly T 33
ACV F 175 35
ECON RC 40
WMAG 41
DVA 175 F 44
DVH 175 F 52
Econ PG 63
HV - A 64
HV - AS 64
MV -E 66
MV - A 68
MV - AS 68
EME/F/V/12/00
page 01
&RPSDQ\3UR¿OH(FRQRVWR*URXS
AFWiviWiHV
It’s core activities include the development, manufacturing, marketing, distribution and service of a
full range of high-quality valves, gaskets, industrial hoses, pipes and fittings, flanges and related
equipment for the chemical and petrochemical industries, shipbuilding, equipment and machine
engineering, heating, ventilation & air-conditioning and general industry. Added value is provided
by developing, machining and supplying products specifically geared to projects and customers.
In this respect, Econosto specifically benefits from intensive contacts with leading industrial
engineering firms. An increasing percentage of sales is generated on the project market, in the
form of non-recurring, long-term contracts that guarantee future contributions to cash flow.
Econosto is an international market leader committed to providing high quality products backed by
outstanding customer service and technical support.
Commitment to Quality
Within the Econosto group, Quality reigns
supreme. The name Econosto is respected
as one of the leading manufacturers of
valves and related pipeline equipment in the
world. It’s a reputation earned through the
philosophy of total dedication to quality,
innovation and customer service that’s been Distribution Centre in Holland
a hallmark of the Econosto Group. And it’s a
reputation we strive to maintain. Our
operating mission is to continue to produce an unrivalled level of excellence in our products,
service, performance and availability.
EME/F/V/12/00
page 04
Company Pro¿le - Econosto Mideast B.V.
Overview
Econosto Mideast B.V. is part of the Econosto Group established in 1892 in Rotterdam - The
Netherlands. It is the subsidiary of Econosto Flow and Sealing Technology B.V. based in the
Netherlands. In 1983, we began our pioneering efforts to build ourselves into a force to reckon
with in the Middle East. Growing from strength to strength, Econosto Mideast B.V. has its head
quarters in Dubai Investments Park (DIP), Dubai and our own offices and agents in most of the
Middle East countries, neighbouring Arab countries, Africa and the sub-continent.
Econosto’s experience in valves, pipes, flanges, gaskets, instruments and pipeline equipment
spreads over more than 100 years. Econosto has well established sales offices, warehouses
(stocks) and sound representations throughout major countries & markets of the world. Under the
dynamic team of thorough - core professionals Econosto Mideast B.V. has made significant
presence in the Middle East, the Arab world, CIS counties & Africa and is well entrenched in the
U.A.E. and other countries in the G.C.C. Apart from other countries Econosto Mideast B.V. also
have offices in India, Pakistan and South Africa. In other territories like Iran, Iraq, Jordan,
Lebanon, Egypt, Syria, Kazakhistan we operate through reputed agents. Econosto has a team of
dedicated and qualified Engineers in the sales & marketing division in all our offices (Sharjah,
Dubai, Abu Dhabi, Qatar, Kuwait, Saudi Arabia, Oman, Pakistan, South Africa) to ensure a high
level of professional service to our customers.
Econosto Mideast Quality Management System has been approved by ABS Quality Evaluations
Ltd., in compliance with: Quality - ISO 9001:2008, Environmental Management System - ISO 14001:
2004, Occupational Health & Safety - OHSAS 18001: 2007.
EME/F/V/12/00
page 05
Econosto is an international market leader committed to providing high quality products backed
by outstanding customer service and technical support. Our global expertise combined with local
availability, ensures that our customers benefit from high quality products, together with
outstanding customer service and technical support.
Warehouses in Dubai and Qatar, one of the largest in the Middle East, facilitate exstock
delivery of valves, Instruments, gaskets, pipes, fittings and pipeline equipment and operate on a
fully computerized stock control system to
ensure continued availability and thus
customer satisfaction. We also have a
stocking point in Dammam in Saudi Arabia
for local distribution in the Kingdom. The
standard inventory comprises of a
exhaustive range of Valves, Pipes, Fittings
(M.I. & B.W), Flanges, Gaskets, Grooved
Fittings and Couplings, Instruments and
related pipeline equipment according to
API, DIN, BS EN, ANSI and ASTM
specifications. Our warehouse and office
in Dubai Investments Park has an area
of 30,000 sq.meters and is located at a
prime location in Dubai.
Meeting expectations
Our industrial customers are constantly innovating. Econosto can make a strong contribution in
research and development through technical support and applications. It goes without saying that
these products not only meet our own strict norms but certainly comply with client specifications
too. Thanks to our skilled engineers and well equipped production plants we can modify and test
products under our own control to meet the client’s wishes. With the strength of our knowledge,
we always find a suitable solution.
Project management
The combination of the knowledge of project management, planning, co-ordination, progress
control and status reporting give Econosto an unique position in the market. That is why you can
expect us to be able to manage national and international projects in a professional manner.
In addition we have extensive
collaborations with renowned engineering
and consultancy companies. And
regardless the size of the project,
Econosto always delivers in compliance
with the applicable quality, safety, labor
conditions and environmental norms.
Advantages
Complete product range according to the valid
norms and specification
Technical support and consultancy
Just-in-time deliveries
Key supply and total cost of ownership
Specials according to client specification
Project and account management
Framework agreements ireand bundled
Fighting deliveries
Application
EME/F/V/12/00
After-sales service /F
Our own product development and engineering
page 06
Vi
sion & Mi
ssi
on Statementand QHSE Pol
icy
VISION STATEMENT
QHSE POLICY
x To be the bestin class by creating a corporat e culture
thatwillbe a modelof an i nnovat i
ve company. W e at Econosto Mi deast b.v. aim to achi
eve the highest standards of
x EME wi l
l be a dynami c, uni que and prof it
abl e Quality, Health, Safety and Environment throughoutouroperations.
business enterprise t
hatachi eves unri valled cust omer Quality
service by ourpeopl e,passi onately st ri
ving to be t he
best W e are dri
ven by ourcomm i t
m entto continuous qual i
ty i
m provem entand
x EME wi l
lbe the leading company i nt he indust ry with exceedi
Mi
ng ourcustom erexpectati
deast b.v. in 1984, our domi
ons.Since the establ
nant operati
ng phi l
i
shm entofEconosto
osophy has been to
continuous commi tment t o qual it
y& t otalcust omer recognize cli
ent requi rem ent
s and devel op / provi de superi or quali
ty,
sati
sfaction com peti
ti
ve product s and professionalservices to sati
sfy and exceed our
x EME wi llnotonl y be the besti n cl ass,i twi l
lbe a custom erexpectati
has been ourguidi
ons.Customerdel
ng force.
i
ghtthrough totalqual ity and service
fantasti
c company wi th a greatenvi ronmentt o work
in, where everybody f eels comf ortabl e, grows and W e fi
rmly believe thatan i nternati
onally recognized Quality Managem ent
enriches bot h their professional and personal l ife, System com pl yi
ng with I
SO 9001: 2008 is an i
m portantel
ementi n achievi
ng
ourstrategic business goals and obj ecti
ves.W e regard Qual ity Assurance
having a lotoffun i
nt he process as an on-going process i ntegrated into the overallcorporate goal-setti
ng
process.
MISSION STATEMENT
Health, Safety and Environment (HSE)
x To be t he leadi ng manuf acturer and suppl i
er int he
valve and pi pi
ng i ndust ry conduct ing our busi ness Econosto Mi deastb.v.af fi
rms it
s comm itm entto provi de and conti
nually
witht otalintegri ty. i
m prove a safe and heal thy work pl
ace foralli
ts em pl
oyees and ensure that
i
ts operations are carri
ed outin a m annerthatprotects the envi
ronmentand
x To f orm st rategi c al l
iances and part nerships wi th comm uni tyin general.
cust omers and suppl iers,t o understand theirneeds,
with an ai m t o add val ue,by provi ding cost effective Our philosophy i s that allaccidents are preventabl
e and no task is so
i
m portant that ri
sk of i
nj ury to peopl
e or dam age to the envi
ronm ent i
s
product s and sol utions t hatare oft he highestqual i
ty j
usti
fi
ed.
standards.
x To be passi onat ely cust omer f ocused and market Our objectives shall be based on:
driven,cont inual l
y st rivi
ng t o raise our performance x Prom oti ng a posi ti
ve HSE cul ture and com plying wi th all
levels. appl i
cabl e HSE statutoryregulati
ons
x To const ant lyfind new ways t o exceed expect ations x Identifying,el i
mi nati
ng,preventing and control
li
ng hazards and
ofourcust omers and t o st ay ahead ofthe compet ition pollution that coul d cause injury, i
ll
ness, or envi ronm ental
dam age
through i nnovat i
on x Provi ding trai
ning and resources forem pl
oyees to m ai
ntai
n HSE
x To at tract and ret ain t he bri ghtest
, boldest and systems and i ntegrati
ng HSE procedures into every operati on
ent husiast i
c workf orce and creat e an envi ronment within the company
where each i ndi vidual can devel op t o theirf ull Every m emberofthe managem entteam shal lvisi
bly uphold the pri
ncipl
es
pot ential. ofthis pol
icy and i
ntegrate them t
hroughoutthei roperati
ons and ensure the
x To del iverourst ake hol ders i ncreased sustained and HSE managem entsystem i simpl em ented and maintained to sustai
n thi
s
poli
cy.
superi orret urns.
Certi
fi
cates
page 07
Qual
ity,Heal
th & Safetyand Envi
ronmentManagementSystem (QHSE)
page 08
Specialized services
offered are:
Fire Protection Engineering:
&RGH&RQVXOWLQJ
%XLOGLQJ&RGH$QDO\VLV
/LIH6DIHW\(YDOXDWLRQV Fire Protection Division emphasizes
([LW$QDO\VLV6WXGLHV innovation in each project. Our goal is
)LUH /LIH6DIHW\3URJUDP'HYHORSPHQW WR¿QGWKHRSWLPDOVROXWLRQWKDW
3HUIRUPDQFH%DVHG'HVLJQ5HYLHZV SURYLGHVDKLJKOHYHORIOLIHVDIHW\DQG
9DOXH(QJLQHHULQJ
asset protection at the best possible
cost while meeting all applicable
Code Consulting: FRGHVDQGUHJXODWLRQV
%XLOGLQJ&RGH$QDO\VLV
2XUQXPEHURQHIRFXVLVVHUYLFHWR
/LIH6DIHW\(YDOXDWLRQV RXUFXVWRPHUVDQGFRPPXQLFDWLRQ
([LW$QDO\VLV6WXGLHV ZLWKDOOVWDNHKROGHUVLQHDFKSURMHFW
)LUH /LIH6DIHW\3URJUDP'HYHORSPHQW :HEHOLHYHWKDWJRRGGHVLJQFRXSOHG
3HUIRUPDQFH%DVHG'HVLJQ5HYLHZV ZLWKRSHQDQGKRQHVWFRPPXQLFDWLRQ
between all partners through the
System(s) – Turnkey Solutions: HQWLUHGHVLJQDQGFRQVWUXFWLRQRID
6SULQNOHU6\VWHPVDVSHU1)3$ SURMHFWLVWKHUHFLSHIRUDVXFFHVVIXO
6WDQGSLSH6\VWHPVDVSHU1)3$ RXWFRPHDQGKDSS\FOLHQWV
)LUH:DWHU3XPSLQJ6\VWHPDVSHU1)3$
2XUXOWLPDWHJRDOVDUHWREXLOGORQJ
'HOXJH6SUD\6\VWHPVDVSHU1)3$
WHUPUHODWLRQVKLSVZLWKRXUFOLHQWVWR
)RDPEDVHG6\VWHPDVSHU1)3$
DGYDQFHWKH¿HOGRI¿UHSURWHFWLRQWR
)LUH$ODUP6\VWHPDVSHU1)3$
VDYHOLYHVDQGSURSHUW\WKURXJK
)LUH+\GUDQW6\VWHPVDVSHU1)3$
H[FHOOHQWGHVLJQDQGWREHSUR¿WDEOH
&OHDQ$JHQW6\VWHPVDVSHU1)3$
ZKLOHGRLQJVR
RWKHUUHTXLUHGVXSSUHVVLRQV\VWHPVDVSHU
UHOHYDQW1)3$VWDQGDUGV
(FRQRVWR¶V )LUH 3URWHFWLRQ 'LYLVLRQ ^(&21 ),5(` VSHFLDOL]HV LQ QHDUO\ HYHU\ VHFWRU RI )LUH 3URWHFWLRQ &RGH
&RQVXOWLQJ LQFOXGLQJ ¿UH SURWHFWLRQ V\VWHPV GHVLJQ VXSSO\ LQVWDOODWLRQWKUR¶ ZRUNLQJ SDUWQHUV WHVWLQJ
FRPPLVVLRQLQJ PDLQWHQDQFH EXLOGLQJ FRGH DQDO\VLV ¿UH OLIH VDIHW\ VWXGLHV SODQ UHYLHZ DOO GLVFLSOLQHV ¿UH
SURWHFWLRQPDVWHUSODQQLQJDQGHGXFDWLRQDOVHPLQDUV
2XUHQJLQHHUVKDYHH[WHQVLYHH[SHULHQFHLQODUJHVFDOHSURMHFWVIRUDOOW\SHVRIRFFXSDQFLHVDQGDUHZHOOYHUVHG
RQWKHHQWLUHPRGHOEXLOGLQJFRGHVLQFOXGLQJWKH,QWHUQDWLRQDO&RGHVDQG1)3$FRGHV VWDQGDUGV
³&HQWUDOL]HG (QJLQHHULQJ 'HSDUWPHQW´ HIIHFWLYHO\ XWLOL]HV WKHLU FRPSXWHU FDSDELOLWLHV IRU K\GUDXOLF DQDO\VLV
FRPSXWHUDLGHGGHVLJQ$XWR&$'FRVWHVWLPDWLQJDQGSURMHFWPDQDJHPHQW
EME/F/V/12/00
page 09
Gate Valves
W here throttl
ing i
s requi
red,Econosto recommends the use ofa gl obe valve.Cl ose regulati
on is
impossi ble with a regul
ar gate valve.Vel oci
ty offlow agai nsta partl y opened di sc may cause
vibration and chatteri
ng and resultin damage to the seatsurfaces and the i nternalassembl y as
wel l
.Moreoverwhen throttl ed the disc is subjected to severe wire-drawing erosive effects.Gate
Valves are desi gned foruse in ful
ly open orful l
y closed positi
on and are notrecommended for
throttl
ing.
page 11
Gate Valves
Cast Iron Gate Valve to AWWA C509 Rising Stem, Resilient Wedge, 200 PSI Working pressure,
Flanged to ANSI B16.1 Class 125, fusion bonded epoxy coated to fire engine red. Pre grooved
stem for supervisory switch mounting.
Pressure
Working cold non-shock pressure : 200 PSI
Hydrostatic test pressure Shell : 400 PSI
Seat : 200 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Flange drilling
Size ( 2 ½" - 12")
Stem ( SS Brass )
Material Specification
No C omponent Material
01 Body Cast Iron ASTM A126 Class B
02 Wedge Cast Iron ASTM A126 Class B, EPDM Encapsulated
03 Wedge Nut Stainless Steel
04 Gasket EPDM
05 Stem Brass
Stainless Steel
06 Bonnet Cast Iron ASTM A 126 Class B
07 O-Ring EPDM
08 Packing Graphite
09 Hand Wheel Ductile Iron ASTM A536 Gr.65-45-12
10 Bolts and Nuts Stainless Steel
11 Packing Gland Cast Iron ASTM 126 Class B
12 Yoke Nut Bronze ASTM B62 C83600
13 Lock Nut Ductile Iron ASTM A536 Gr.65-45-12, Chrome Plated
page 12
Gate Valves
Ductile Iron Gate Valve to AWWA C509 Rising Stem, Resilient Wedge, 250 PSI Working pressure,
Flanged to ANSI B16.1 Class 125, Fusion bonded epoxy coated to fire engine red. Pre grooved
stem for supervisory switch mounting.
Pressure
Working cold non-shock pressure : 250 PSI
Hydrostatic test pressure Shell : 500 PSI
Seat : 250 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Flange drilling
Size ( 2 ½" - 12")
Stem ( SS / Brass )
Material Specification
No C omponent Material
01 Body Ductile Iron ASTM A536 Gr.65-45-12
02 Wedge Ductile Iron ASTM A536 Gr.65-45-12
03 Wedge Nut Stainless Steel
04 Gasket EPDM
05 Stem Brass
Stainless Steel
06 Bonnet Ductile Iron ASTM A536 Gr.65-45-12
07 O-Ring EPDM
08 Packing Graphite
09 Hand Wheel Ductile Iron ASTM A536 Gr.65-45-12
10 Bolts and Nuts Stainless Steel
11 Packing Gland Cast Iron ASTM 126 Class B
12 Yoke Nut Bronze ASTM B62 C83600
13 Lock Nut Ductile Iron ASTM A536 Gr.65-45-12, Chrome Plated
page 13
Gate Valves
Ductile Iron Gate Valve to AWWA C515, Rising stem, Resilient wedge, 300 PSI
Working Pressure, Flanged to ANSI B16.1 Class 250, Fusion bonded epoxy coated to fire
engine red.
Pressure
Working cold non-shock pressure : 300 PSI
Hydrostatic test pressure Shell : 600 PSI
Seat : 300 PSI
Application
Cold water, Fire water
ECON Ductile Iron Gate Valve
Options (Available on Request) Fig . GVOSY E 300 F
EN 1092 - 2 PN10 / CL125 Flange drilling
Resilient Wedge OS&Y
300 PSI / 20 bar
Accessories UL Listed
Supervisory switch, Model OSYSU-1,2 FM Approved
AWWA C515
Operation
Hand wheel
Ordering Information
Figure number D
Flange drilling
Size ( 2 ½" - 12")
H (Open)
Material Specification
No C omponent Material
01 Body Ductile Iron ASTM A536 Gr.65-45-12
02 Wedge Ductile Iron ASTM A536 Gr.65-45-12, EPDM Encapsulated
03 Wedge Nut Stainless Steel
04 Gasket EPDM
05 Stem Stainless Steel
06 Packing Graphite - Non-Asbestos
07 Bonnet Ductile Iron ASTM A536 Gr.65-45-12
08 Yoke Nut Bronze L
09 Hand Wheel Ductile Iron ASTM A536 Gr.65-45-12
10 Packing Gland Ductile Iron ASTM A536 Gr.65-45-12
11 Body Bonnet Bolt Carbon Steel
12 Gland Flange Bolt and Nuts Stainless Steel
page 14
Gate Valves
Cast Iron Gate Valve to AWWA C509, Resilient Wedge, 200 PSI Working pressure, Flanged to
ANSI B16.1 Class 125, Fusion bonded epoxy coated to fire engine red.
Pressure
Working cold non-shock pressure : 200 PSI
Hydrostatic test pressure Shell : 400 PSI
Seat : 200 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Flange drilling
Size ( 2 ½" - 12")
Stem ( SS / Brass )
Material Specification
No C omponent Material
01 Body Cast Iron ASTM A126 Class B
02 Wedge Cast Iron ASTM A126 Class B, EPDM Encapsulated 2 ½” & 3 “
03 Wedge Nut Bronze ASTM B62 C83600
04 Gasket EPDM
05 Stem Brass
Stainless Steel
06 Bonnet Cast Iron ASTM A 126 Class B
07 O-Ring EPDM
08 Indicator Post Flange Ductile Iron ASTM A536 Gr.65-45-12
09 Operating Nut Ductile Iron ASTM A536 Gr.65-45-12
10 Indicator Flange Bolts Stainless Steel
11 Body Bonnet Bolts and Nuts Carbon Steel
4” & above
page 15
Gate Valves
Ductile Iron Gate Valve to AWWA C509, Resilient wedge, 250 PSI Working pressure, Flanged to
ANSI B16.1 Class 125, Fusion bonded epoxy coated to fire engine red.
Pressure
Working cold non-shock pressure : 250 PSI
Hydrostatic test pressure Shell : 500 PSI
Seat : 250 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Flange drilling
Size ( 2 ½" - 12")
Stem ( SS / Brass )
Material Specification
No C omponent Material
01 Body Ductile Iron ASTM A536 Gr. 65-45-12
02 Wedge Ductile Iron ASTM A536 Gr. 65-45-12, EPDM Encapsulated 2 ½” & 3”
03 Wedge Nut Bronze ASTM B62 C83600
04 Gasket EPDM
05 Stem Brass
Stainless Steel
06 Bonnet Ductile Iron ASTM A536 Gr. 65-45-12
07 O-Ring EPDM
08 Indicator Post Flange Ductile Iron ASTM A536 Gr.65-45-12
09 Operating Nut Ductile Iron ASTM A536 Gr.65-45-12
10 Indicator Flange Bolts Stainless Steel
11 Body Bonnet Bolts and Nuts Carbon Steel
4” & Above
page 16
Gate Valves
Ductile Iron Gate Valve to AWWA C515, resilient wedge, 300 PSI Working pressure, Flanged to
ANSI B16.1 Class 250, Fusion bonded epoxy coated to fire engine red.
Pressure
Working cold non-shock pressure : 300 PSI
Hydrostatic test pressure Shell : 600 PSI
Seat : 300 PSI
Application
Cold water, Fire water
Material Specification
No C omponent Material
01 Body Ductile Iron ASTM A536 Gr. 65-45-12
02 Wedge Ductile Iron ASTM A536 Gr. 65-45-12, EPDM Coated
03 Disc Nut Bronze
04 Gasket EPDM
05 Stem Stainless Steel
06 Bonnet Ductile Iron ASTM A536 Gr. 65-45-12
07 NPT Plug Brass B16 C36000
08 Thrust Collar Bronze ASTM B62 C83600
09 Gland Ductile Iron ASTM A536 Gr. 65-45-12
10 Wrench Nut Ductile Iron ASTM A536 Gr. 65-45-12
11 Indicator Post Flange Ductile Iron ASTM A536 Gr. 65-45-12
12 Indicator Flange Bolts Stainless Steel
13 Body Bonnet Bolt Carbon Steel
page 17
Vertical Indicator Post
Cast iron vertical indicator post, field adjustable.
Application
Operating ECON non rising stem (NRS) fire service valves
Material Specification
No C omponent Material
01 Hex Cap Screw Carbon Steel ASTM A307B
02 Hex Nut Carbon Steel ASTM A307B
03 Crane Coupling Ductile Iron ASTM A536 Gr.65-45-12
04 Cotter Pin Stainless Steel AISI 304
05 Base Flange Cast Iron ASTM A126 Class B
06 Hex Nut Carbon Steel ASTM A307B
07 Hex Cap Screw Carbon Steel ASTM A307B
08 Stand Pipe Carbon Steel ASTM A53
09 Stem 1" Square SS AISI 1020
10 Body Cast Iron ASTM A126 Class B
11 Locking Wrench Ductile Iron ASTM A536 Gr.65-45-12
12 Target Carrier Nut Stainless Steel AISI 304 / Bronze ASTM B62 C83600
13 Hex Cap Screw Carbon Steel ASTM A307B
14 Hex Nut Carbon Steel ASTM A307B
15 Hex Cap Screw Carbon Steel ASTM A307B
16 Target Cast Aluminium
17 Window Glass Plexiglass
18 Gasket PTFE
19 Operating Nut Stainless Steel AISI 304 / Bronze ASTM B62 C83600
20 Top Section Cast Iron ASTM A126 Class B
21 Snap Ring Stainless Steel AISI 066
22 Plug Malleable Iron
23 Square Nut Carbon Steel ASTM A307B
24 Hex Cap Screw Carbon Steel ASTM A307B
EME/F/V/12/00
page 18
Wall Indicator Post
Cast iron vertical indicator post, field adjustable.
Application
Operating ECON non rising stem (NRS) fire service valves
Material Specification
No C omponent Material
01 Eye Bolt Carbon Steel ASTM A307B
02 Hex Nut Carbon Steel ASTM A307B
03 Washer Carbon Steel ASTM A 570 Gr. 33
04 Hand Wheel Ductile Iron ASTM A536 Gr.65-45-12
05 Hex cap Screw Carbon Steel ASTM A307B
06 Square Nut Carbon Steel ASTM A307B
07 Snap Ring Stainless Steel AISI 1066
08 Cover Cast Iron ASTM A126 Class B
09 Operating Nut Stainless Steel AISI 304 / Bronze ASTM B62 C83600
10 Target Carrier Nut Stainless Steel AISI 304 / Bronze ASTM B62 C83600
11 Window Glass Plexiglass
12 Gasket PTFE
13 Hex Nut Carbon Steel ASTM A307B
14 Plug Malleable Iron
15 Target Cast Aluminium
16 Hex Cap Screw Carbon Steel ASTM A307B
17 Hex Nut Carbon Steel ASTM A307B
18 Body Cast Iron ASTM A 126 Class B
19 Stem SS AISI 1045
20 Crane Coupling Ductile Iron ASTM A536 Gr.65-45-12
21 Cotter Pin Stainless Steel AISI 304
EME/F/V/12/00
page 19
Check Valves
Asmenti oned above the checkval vesare used to preventthe reversaloffl ow in piping systems.The
valve iskeptopen byl ine pressure whi le cl
osure isautomati cal lyactivated bythe reversaloffl ow by
the weightofthe di sc mechani sm.The di sc and any otherassoci ated movi ng parts are al ways ina
state ofmovementi fthe veloci ty offlow and pressure i s notsufficientto hol d the disc in wi de open
and stable / fixed positi
on.Thi smayl ead to a high frequencynoi se in the pipeline.Premature wear
and noi syoperati on orvi brati
on can be avoi ded bysel ecting the size ofthe checkval ve on the basi s
offlow condi ti
ons.The correctsi zing ofcheck val ve is very i
mportant,parti cularly when the servi ce
is on waterl ines and othernon-compressi ble fl
uids.Propersi zing ofcheck val ves is very important
foramaxi mum servi cel i
feandal soi slocatingi tawayfrom thepul satingpump.W henusedi nproxim-
ityofa pump,we recommend thatthe checkval ve shoul d be the same si ze asthe di scharge ori fi
ce
on the pump.The excessi ve turbul ence through the check val ve notonl y causes a cl atter,butalso
resultsin rapi d wearofthe i nternalparts.
page 20
Check Valves
Ductile Iron Check valve to AWWA C508, Clear waterway, Maximum operating pressure 300 PSI,
Flanged ends to ANSI B16.1 Class 125/250 FF. Fusion bonded epoxy interior and exterior to fire
engine red.
Pressure
Working cold non-shock pressure : 300 PSI
Application
Cold water, Fire water
Material Specification
No C omponent Material
01 Seat Ring Bronze B62
02 NPT Plug Brass
03 Hinge Pin SS304 AISI 304
04 Retainer Washer Bronze B62
05 Disc Ductile Iron A536 65-45-12
06 Disc Seat EPDM
07 Clapper Arm Ductile Iron A536 65-45-12
08 Gasket EPDM
09 Cover Ductile Iron A536 65-45-12
10 Body Ductile Iron A536 65-45-12
12 660 343 -
page 21
Check Valves
Cast Iron Check valve, Maximum operating pressure 175 PSI, Wafer ends, Suitable to mount
between ANSI B16.1 Class 125 FF. Flanges, Fire engine red epoxy painting.
Pressure
Working cold non-shock pressure : 175 PSI
Hydrostatic test pressure : 350 PSI
Application
Cold water, Fire water
Material Specification
No C omponent Material
01 Body Cast lron ASTM Al26 Class B
02 Disc Stainless Steel AlSl 304
03 Spring Stainless Steel AISl 304
04 Hinge Pin Stainless SteeI AISl 416
05 Stop Pin Stainless Steel AISl 416
06 Spacer PTFE
07 Pin Retainer Stainless SteeI AISI 416
08 Gasket PTFE
09 Washer PTFE
10 Lifting Hook Carbon SteeI(Not Shown,only for 8",10"&12")
page 22
Check Valves
Ductile Iron Swing Check Valve, Maximum operating pressure 300 PSI, Grooved ends,
Epoxy coated interior and exterior to fire engine red.
Pressure
Working cold non-shock pressure : 300 PSI
Max test pressure : 600 PSI
Application
Cold water, Fire water
½” NPT
Material Specification
No C omponent Material D C
01 Body Ductile iron conforming to ASTMA 536 epoxy coated
02 Clapper 2"-5" type 304or 302 SS to ASTMA 167 6"-8" DI to ASTMA 536 65-45-12
03 Clapper Facing EPDM
04 Seat Ring Type SS 304
05 Spring Stainless steel
06 Hinge Pin Stainless steel
07 Hinge Pin Bushings Sintered bronze to ASTMB438
E
Dimensions & Weights
Nominal Size A B C D E Weight
DN (Inches) mm mm mm mm mm Kg
2 169 60 36 81 111 2.5
2½ 183 61 39 86 114 5.0
3 198 67 51 93 125 6.0
4 218 79 57 108 152 9.0
6 270 108 84 171 216 18.0
8 325 128 100 203 260 33.0
EME/F/V/12/00
page 23
Strainers
page 24
Y Type Strainers
Cast Iron Y strainer, 175 PSI operating pressure, Flanged ends to ANSI B16.1 Class 125,
Epoxy coated to fire engine red.
Pressure
Working cold non-shock pressure : 175 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Size ( 2 ½" - 12") ECON Cast Iron Y Strainer
Fig . YS-F-1161 EF
175 PSI / 12 bar
UL Listed
Material Specification
No C omponent Material Standard Screens
01 Body Cast Iron ASTM A126 Class B Size Hole Dia. Free Flow Area
(mm) (mm) (%)
02 Cover Cast Iron ASTM A126 Class B
03 Screen Stainless Steel AISI 304 65 3.0 51
04 Gasket PTFE/Graphite
05 Plug Ductile Iron ASTM A536 Gr. 65-45-12 80 - 200 4.3 54
06 Bolts Carbon Steel
150 - 250 6.0 63
300 6.3 70
page 25
Y Type Strainers
Ductile Iron ‘Y’ strainer, 175 PSI operating pressure, Grooved ends, Epoxy coated to fire
engine red.
Pressure
Working cold non-shock pressure : 175 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Size ( 2 ½" - 12") ECON Ductile Iron Y Strainer
Fig .YS-G-1251 EG
175 PSI / 12 bar
UL Listed
Material Specification
No C omponent Material Standard Screens
01 Body Ductile Iron ASTM A536 Gr. 70-50-05 Size Hole Dia. Free Flow Area
(mm) (mm) (%)
02 Cover Ductile Iron ASTM A536 Gr. 70-50-05
03 Screen Stainless Steel AISI 304 65 2.54 37.4
04 Gasket PTFE/Graphite
05 Plug Ductile Iron ASTM A536 Gr. 70-50-05 80 - 200 4.7 46
06 Bolts Carbon Steel
250 4.7 51
300 6.3 58
page 26
Butterfly Valves
Valvesbel ow 65mm nomi nalbore have a bronze bodywi th threaded orgrooved ends.Al lwaferend
valves are suitable formounti ng between ANSIB16.1 Cl ass 125 flanged.Forgrooved end val ves
please referthe table forpipe dimensi ons.AllECON Fi re Servi ce Butterfl
y Valves are suppli
ed wi
th
i
ntegralgearboxes.The gearboxesare desi gned forl
ow torque and hi gh cycl
el i
fe.The gearboxes
also come wi th an easy to read fl
ag type positi
on i
ndi
cator.The val ve and tamperswi tch assembly
are rated forboth outdoorand i ndooruse.
Allbutterfl
y val
ves al
so come with factory i
nstal
led UL l
isted dualsupervi
sory/tamperswitches.The
valvesare designed for175 PSI(12 bar)and 300 PSI(21 bar)operati ng pressures.Pl
ease referthe
wiri
ng diagram fortamperswi tch detail
s.
EME / F / V / 11 / 01
EME/F/V/12/00
page 27
Butterfly Valves
Ductile Iron Butterfly Valves, Grooved ends, 175 PSI operating pressure EPDM encapsulated
disc, Gear operated, complete with factory installed dual tamper switches.
Pressure
Working cold non-shock pressure : 175 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Size ( 2 ½" - 8")
Material Specification
No C omponent Material
01 Body Ductile Iron ASTM A536 Nylon Coated
02 Disc Ductile Iron ASTM A536 EPDM Encapsulated
03 Stem Stainless Steel
04 Gear housing Ductile Iron ASTM A536 65-45-12
page 28
Butterfly Valves
Ductile Iron Butterfly Valves, Grooved ends, 300 PSI operating pressure EPDM encapsulated
disc, Gear operated, complete with factory installed dual tamper switches.
Pressure
Working cold non-shock pressure : 300 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Size ( 2 ½" - 8")
Material Specification
No C omponent Material
01 Body Ductile Iron ASTM A536 Nylon Coated
02 Disc Ductile Iron ASTM A536 EPDM Encapsulated
03 Stem Stainless Steel
04 Gear housing Ductile Iron ASTM A536 65-45-12
page 29
Butterfly Valves
Ductile Iron Butterfly Valves, Wafer ends, 175 PSI operating pressure EPDM encapsulated
body, Gear operated, complete with factory installed dual tamper switches.
Pressure
Working cold non-shock pressure : 175 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Size ( 2 ½" - 8")
Material Specification
No C omponent Material
01 Body Ductile Iron ASTM A536 EPDM Encapsulated
02 Disc Ductile Iron Ni Cr Plated
03 Stems Stainless Steel
04 Gear housing Ductile Iron ASTM A536 65-45-12
05 Hand Wheel ASTM A 619
page 30
Butterfly Valves
Ductile Iron Butterfly Valves, Wafer ends, 300 PSI operating pressure EPDM encapsulated
body, Gear operated, complete with factory installed dual tamper switches.
Pressure
Working cold non-shock pressure : 300PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Size ( 2 ½" - 8")
Material Specification
No C omponent Material
01 Body Ductile Iron ASTM A536 EPDM Encapsulated
02 Disc Ductile Iron ASTM A536 Ni Cr Plated
03 Stem Stainless Steel
04 Gear housing Ductile Iron ASTM A536 65-45-12
05 Hand Wheel Ductile Iron ASTM A536 65-45-12
page 31
Butterfly Valves
Bronze Butterfly Valves, Grooved ends, 175 PSI operating pressure EPDM encapsulated disc,
Gear operated, complete with factory installed dual tamper switches.
Pressure
Working cold non-shock pressure : 175 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Size ( 2” & 2 ½")
Material Specification
No C omponent Material
01 Body Bronze ASTM B505
02 Disc Ductile Iron ASTM A536 EPDM Encapsulated
03 Stem Stainless Steel
page 32
Butterfly Valves
Bronze Butterfly Valves, Threaded ends, 175 PSI operating pressure EPDM encapsulated disc,
Gear operated, complete with factory installed dual tamper switches.
Pressure
Working cold non-shock pressure : 175 PSI
Application
Cold water, Fire water
Ordering Information
Figure number
Size (1 ¼" - 2 ½”)
Material Specification
No C omponent Material
01 Body Bronze ASTM B505
02 Disc Ductile Iron ASTM A536 EPDM Encapsulated
03 Stem Stainless Steel
page 33
Alarm Check Valves
Note:The li
sti
ng ofUL,approvals and m anufacturer'
swarranty are valid onl
y when the al
arm
check val
vesinstal
led wi
th ECON tri
m setand i
nstall
ed as pertri
mi nstal
lati
on gui
de l
ines.
EME/F/V/12/00
page 34
Alarm Check Valves
Cast Iron Check Valve, Maximum operating pressure 175 PSI, Flanged ends to ANSI B16.1
Class 125 FF. threaded tapping BSPT, suitable for vertical mounting, Fire engine red
epoxy painting.
Pressure
Working cold non-shock pressure : 175 PSI
Hydrostatic test pressure : 355 PSI
Application
Wet pipe system as per NFPA 13 and NFPA 25
ECON Cast Iron Alarm Check
Options (Available on Request) Valve
Flange drilling to IS : 1538 Fig . ACV F 175
NPT Threaded opening 175 PSI / 12 bar
UL Listed
Accessories
Constant pressure trim
Retard chamber
Water motor alarm gong
Ordering Information
Valve size ( 3" - 8")
Flange drilling
Trim details
Material Specification
No C omponent Material
01 Housing Cast Iron
02 Seat Bronze
03 Clapper Bronze
04 Seat Rubber Neoprene
05 Rubber Clamp Stainless Steel AISI 304
06 Bolt Stainless Steel AISI 304
07 Clapper Bush Bronze
08 Body Bush Bronze
09 Hinge Pin Stainless Steel AISI 304
10 Bolts Steel
11 Plug Brass
12 Cover Gasket Neoprene
13 Hand hold Cover Cast Iron
page 35
Alarm Check Valves
19
19
18
16 17 24
16
23
17
15
18
18
To Drain
13
27
14
$ 20
1 2
22
10 12
2
1
2 6 1
11
25
1 7
26
8
1 9
1 5
5
2
4
1 3 3
21
page 36
Alarm Check Valves
Schematic
To System
PG PG
PS
AT G
AV
AC
To Drain
To Drain To Drain
From Supply
To
cD
Sprinkler
Alarm
D
To
Drain To
Drain
A B
Dimensions
Nominal Size A B C D E
DN (Inches) mm mm mm mm mm
350 490 710 230 290
EME/F/V/12/00
3
4 380 490 710 230 290
6 400 530 750 230 290
8 420 550 790 240 310
page 37
Alarm Check Valves
To Drain
page 38
Alarm Check Valves
Schematic
To System PS
PG PG
AT RC
AV To Drain
AC
To Drain
To Drain
From Supply
To
Sprinkler
Alarm
E
C
D
To
Drain To
Drain
A B
Dimensions
Nominal Size A B C D E
DN (Inches) mm mm mm mm mm
EME/F/V/12/00
page 39
Alarm Check Valves
Stainless steel retard chamber, ¾ “ BSPT (F) inlet, weight 2.6 kg
Application
Part of UL listed Trim for Econ ACV F 175
3/4" BSPT
ECONOSTO
page 40
Alarm Check Valves
Water motor alarm gong ¾” BSPT inlet, 1” BSPT outlet, 205mm gong diameter aluminium
housing epoxy red powder coated, weight 3.0kg
Pressure
Low flow test pressure : 5 PSI
High flow test pressure : 100 PSI
Ordering Information
Figure number ECON Water Motor
Mounting type Alarm Gong
Fig . WMAG
UL Listed
Spri
nkl
erAl
arm
Model-W mag A
listed
3S38
ECONOSTO
Inlet
Outl
et
View 'A'
25
Clean Out
Plug
To Drain
22 2 1 3 4 5 14 11 12
16
15
9
No C omponent Material No C omponent Material Ø233
10
01 Housing Aluminium Alloy 1 Housing Aluminium Alloy 14
02 Gong Impeller Delrin 2 Gong Impeller Delrin 8
03 Retaining Ring SS 316 3 Retaining Ring SS 316 23
17 Striker Arm Bolt Aluminium Alloy 17 Striker Arm Bolt Aluminium Alloy 15
Ø122 19 17
18 Striker Arm Washer Aluminium Alloy 18 Striker Arm Washer Aluminium Alloy 21 18
20 13
19 Drive Shaft Aluminium Alloy 19 Drive Shaft Aluminium Alloy
9
20 Housing Cover Aluminium Alloy 20 Housing Cover Aluminium Alloy 10
Ø233
Mounting Type B
EME/F/V/12/00
page 41
Deluge Valve
page 42
Deluge Valve
page 43
Deluge Valves
Cast Iron, Quick release, Hydraulically operated diaphram valve, Maximum operating
Pressure 175 PSI, Flange x Flange to ANSI B16.1 Class 125 FF. Threaded tapping
BSPT ( NPT Optional ) suitable for vertical mounting, Fire engine red epoxy paint finish.
Pressure
Working cold non-shock pressure : 175 PSI
Hydrostatic test pressure : 355 PSI
Application
Deluge systems
Ordering Information
Size ( 2 " - 8")
Flange drilling
Trim options
ØA
12
11
10
9
B
8
Outlet
3
4
Material Specification 5
D
No C omponent Material 6
01 1
Housing Cast Iron C Inlet
02 Seat Bronze
03 Clapper Bronze
04 Seat Rubber Neoprene
05 Rubber Clamp Bronze
06 Bolt (M10) Stainless Steel
07 Diaphragm Neoprene
08 Clamp Ring Bronze
09 Cover Cast Iron
10 Bolt (M20) Carbon Steel
Bolt (M16) Carbon Steel
Bolt (M16) Carbon Steel
11 Bolt (M10) Stainless Steel
12 Bolt (M20) Carbon Steel
Bolt (M16) Carbon Steel
Bolt (M16) Carbon Steel
page 44
Deluge Valves
Dry Pilot Trim with Electric Release for Model DVA 175 F
A1
#
36 From Compressor
#
To Detection Line A3
A2 HD
F IR
E P
16
R OT
E
PV
T.
LT
D.
U
L IS
L
AIR
PR
BN S E P E
/WA
40 T E D F IRE S S UR T E
E R R OT G
V A
MODE IC E E C T
R
UG
IONE F OR
13
17
L-
HDP
6
16 12
7 11 14
7
10
6 18
5
15
7 4
8 3 7 HD
F IR
E P
R OT
E
PV
T.
LT
To Open
D.
11 U
L
L IS
AIR
PR
BN S E P E
/WAT
40 T E D F IRE S S UR
E R R OT G
V A
ER
MODE IC E E C T
L-
HDP
UG
IONE F OR
12 13 Drain
7 To Open
# 28 2 11
Drain
9 10
S1
S2
1 20
S3 To Open
To Priming
Connection Drain
S4
(Below Upstream 19
To Open
Stop Valve)
Drain
28
33 HD
F IR
E P
R OT
E
PV
T.
LT
D.
P3 U
L
L IS
AIR
PR /WAT
40 T E D F IRE S S UR
13
BN S E P E ER
E R R OT G
V A UG
MODE IC E E C T
IONE F OR
L-
HDP
34
P2 #
P1 21 12
29 35
22
30 17
23 31 16
7
32 6
22
26 24
To Alarm
27/2 22
Sprinkler
27/1 25
To Drain
To Drain
EME/F/V/12/00
page 45
Deluge Valves
Trim Components
Qty. Qty. Qty. Qty. Qty.
No Component Size DN50 DN80 DN100 DN150 DN200
01 Pipe Nipple ½" x 80 mm 1 1 1 1 1
02 6 Way Manifold - 1 1 1 1 1
03 Restriction Check Valve - 1 1 1 1 1
04 Y-Strainer ½" 1 1 1 1 1
05 Pipe Nipple ½" x 110 mm - - - 1 1
05 Hex Nipple - 1 1 1 - -
06 Elbow ½" 3 3 3 3 3
07 Hex Nipple ½" 6 6 6 6 6
08 Union ½" 1 1 1 1 1
09 Ball Valve ½" 1 1 1 1 1
10 Elbow ¼" 2 2 2 2 2
11 Hex Nipple ¼" 3 3 3 3 3
12 Gauge Valve ¼" 3 3 3 3 3
13 Pressure Gauge UL Listed 3 3 3 3 3
14 Pipe Nipple ½" x 300 mm - - - - 1
14 Pipe Nipple ½" x 255 mm - - - 1 -
14 Pipe Nipple ½"x 210 mm - - 1 - -
14 Pipe Nipple ½" x 180 mm 1 1 - - -
15 Emergency Release Station MR - 1 1 1 1 1 1
16 Tee ½" 3 3 3 3 3
17 Reducing Hex Nipple ½" x ¼" 2 2 2 2 2
18 Positive drain Actuator - 1 1 1 1 1
19 Pipe Nipple 2" x 110 mm - - 1 1 1
19 Pipe Nipple 1 ¼" x 110 mm 1 1 - - -
20 Angle Valve 2" - - 1 1 1
20 Angle Valve 1 ¼" 1 1 - - -
21 Pipe Nipple ½" x 150 mm - - - 1 1
21 Pipe Nipple ½" x 130 mm 1 1 1 - -
22 Hex Nipple 1" - - 3 3 3
22 Hex Nipple ¾" 3 3 - - -
23 Elbow 1" - - 1 1 1
24 Reducing Tee 1" x ½" x 1" - - 1 1 1
24 Reducing Tee ¾" x ½" x ¾" 1 1 - - -
25 Angle Valve 1" - - 1 1 1
25 Angle Valve ¾" 1 1 - - -
26 Drip Valve - 1 1 1 1 1
27/1 Funnel - 1 1 1 1 1
27/2 Funnel Holder - 1 1 1 1 1
28 Plug ½" 2 2 2 2 2
29 Pipe Nipple ¾" x 100 mm 1 1 1 1 1
30 Swing Check Valve ¾" 1 1 1 1 1
31 Hex Nipple ¾" 1 1 1 1 1
32 Reducing Tee ¾" x ½" x ¾" 1 1 1 1 1
33 Copper Tube Assembly ½" - - - - 1
33 Copper Tube Assembly ½" - - - 1 -
33 Copper Tube Assembly ½" - - 1 - -
33 Copper Tube Assembly ½" 1 1 - - -
34 Ball Valve ½" 1 1 1 1 1
35 Pipe Nipple ½" x 60 mm - - - - 1
35 Hex Nipple ½" 1 1 1 1 -
36 Orifice Nipple ½" 1 1 1 1 1
P1 Pipe Nipple ½" x 135 mm 1 1 1 1 1
P2 Elbow ½" 1 1 1 1 1
P3 Pressure Switch ½" (m) 1 1 1 1 1
A1 Pressure Switch ½" (m) 1 1 1 1 1
A2 Tee ½" 1 1 1 1 1
A3 Hex Nipple ½" 1 1 1 1 1
S1 Pipe Nipple ½" x 130 mm - - 1 1 1
S1 Pipe Nipple ½" x 135 mm 1 1 - - -
S2 Elbow ½" 1 1 1 1 1
S3 Pipe Nipple ½" x 180 mm - - 1 1 1
S3 Pipe Nipple ½" x 135 mm 1 1 - - -
EME/F/V/12/00
page 46
Deluge Valves
Schematic
To Detection
From
~
Line PS Compressor
PG
RCN
NO
PDA
~ PG
NO
OD
~
SV M
RCV
NO PG PS
ER
To
System DV
~
~
NO OD
NC NC
G ~
DR.V CD
~ ~ NC ~ F
OD CD OD
~
From
Supply
Valve Stop Valve PS - Pressure Switch M - Six Way Mainfold G - Sprinkler Alarm
Non Return Valve Optional OD - Open Drain RCN - Restriction Nozzle NO - Normally Open
Strainer By User CD - Common Drain PDA - Positive Drain Actuator NC - Normally Closed
Angle Valve DR.V - Drip Valve DV - Deluge Valve PG - Pressure Gauge SV - Solenoid Valve
F - Funnel ER - Emergency Release Box
Compressed
Air Line
E
To
Sprinkler
Alarm
To Open
Drain To Priming
D
Connection
To Drain
A B
Dimensions
Nominal Size A B C D E
DN (Inches) mm mm mm mm mm
2 350 450 930 450 410
3 350 450 930 450 410
EME/F/V/12/00
page 47
Deluge Valves
Wet Pilot Trim with Electric Release for Model DVA 175 F
14
6
5 To Detection
15
7 4 Line
8 3 HD
FIR
E PRO
TE
PVT
.L
To Open
TD.
11 U
L
AIR
LISTED PRES
40
/W
FIRE SURE
BN SERVIPROT
ATE
MODE CE ECTIO
L-HDP
R
GAUG
E FOR
N
12 13 Drain
7
# 27 2 11
9 10
S1
S2
1 19
S3 To Open
To Priming Drain
Connection S4
(Below Upstream 18
To Open
Stop Valve) Drain
27
32 HD
FIR
E PRO
TE
PVT
.L
TD.
P3 U
L
AIR
LISTED PRES
40
/W
ATE
13
FIRE SURE
BN SERVIPROT R
GAUG
MODE CE ECTIOE FOR
L-HDP N
33
P2 #
P1 20 12
28 34
21
29 17
22 30 16
7
31 6
21
25 23
26/2 21 To Sprinkler
Alarm
26/1 24
To Drain
To Drain
EME/F/V/12/00
page 48
Deluge Valves
Wet Pilot Trim with Electric Release for Model DVA 175 F
Trim Components
Qty. Qty. Qty. Qty. Qty.
No Component Size DN50 DN80 DN100 DN150 DN200
01 Pipe Nipple ½" x 80 mm 1 1 1 1 1
02 6 Way Manifold - 1 1 1 1 1
03 Restriction Check Valve - 1 1 1 1 1
04 Y-Strainer ½" 1 1 1 1 1
05 Pipe Nipple ½" x 110 mm - - - 1 1
05 Hex Nipple - 1 1 1 - -
06 Elbow ½" 3 3 3 3 3
07 Hex Nipple ½" 3 3 3 3 3
08 Union ½" 1 1 1 1 1
09 Ball Valve ½" 1 1 1 1 1
10 Elbow ¼" 1 1 1 1 1
11 Hex Nipple ¼" 2 2 2 2 2
12 Gauge Valve ¼" 2 2 2 2 2
13 Pressure Gauge UL Listed 2 2 2 2 2
14 Pipe Nipple ½" x 300 mm - - - - 1
14 Pipe Nipple ½" x 255 mm - - - 1 -
14 Pipe Nipple ½" x 210 mm - - 1 - -
14 Pipe Nipple ½" x 180 mm 1 1 - - -
15 Emergency Release Station MR - 1 1 1 1 1 1
16 Tee ½" 1 1 1 1 1
17 Reducing Hex Nipple ½" x ¼" 1 1 1 1 1
18 Pipe Nipple 2" x 110 mm - - 1 1 1
18 Pipe Nipple 1 ¼" x 110 mm 1 1 - - -
19 Angle Valve 2" - - 1 1 1
19 Angle Valve 1 ¼" 1 1 - - -
20 Pipe Nipple ½" x 150 mm - - - 1 1
20 Pipe Nipple ½ " x 130 mm 1 1 1 - -
21 Hex Nipple 1" - - 3 3 3
21 Hex Nipple ¾" 3 3 - - -
22 Elbow 1" - - 1 1 1
22 Elbow ¾" 1 1 - - -
23 Reducing Tee 1" x ½" x 1" - - 1 1 1
23 Reducing Tee ¾" x ½" x ¾" 1 1 - - -
24 Angle Valve 1" - - 1 1 1
24 Angle Valve ¾" 1 1 - - -
25 Drip Valve - 1 1 1 1 1
26/1 Funnel - 1 1 1 1 1
26/2 Funnel Holder - 1 1 1 1 1
27 Plug ½" 2 2 2 2 2
28 Pipe Nipple ¾" x 100 mm 1 1 1 1 1
29 Swing Check Valve ¾" 1 1 1 1 1
30 Hex Nipple ¾" 1 1 1 1 1
31 Reducing Tee ¾" x ½" x ¾" 1 1 1 1 1
32 Copper Tube Assembly ½" - - - - 1
32 Copper Tube Assembly ½" - - - 1 -
32 Copper Tube Assembly ½" - - 1 - -
32 Copper Tube Assembly ½" 1 1 - - -
33 Ball Valve ½" 1 1 1 1 1
34 Pipe Nipple ½" x 60 mm - - - - 1
34 Hex Nipple ½" 1 1 1 1 -
P1 Pipe Nipple ½" x 135 mm 1 1 1 1 1
P2 Elbow ½" 1 1 1 1 1
P3 Pressure Switch ½" (m) 1 1 1 1 1
S1 Pressure Switch ½" (m) 1 1 1 1 1
S1 Pipe Nipple ½" x 130 mm - - 1 1 1
S1 Pipe Nipple ½" x 135 mm 1 1 - - -
S2 Elbow ½" 1 1 1 1 1
S3 Pipe Nipple ½" x 180 mm - - 1 1 1
S3 Pipe Nipple ½" x 135 mm 1 1 - - -
S4 Solenoid Valve ½" (Two way) 1 1 1 1 1
EME/F/V/12/00
page 49
Deluge Valves
Schematic
To Detection PG
~
Line
OD NO
~
SV M
RCV
NO PG PS
ER
To System
~ DV
~
NO
OD
NC NC
G ~
DR.V
CD
~ ~ NC F
~
CD OD
OD
~
From
Supply
Valve Stop Valve PS - Pressure Switch M - Six Way Mainfold G - Sprinkler Alarm
Non Return Valve Optional OD - Open Drain RCN - Restriction Nozzle NO - Normally Open
Strainer By User CD - Common Drain PDA - Positive Drain Actuator NC - Normally Closed
Angle Valve DR.V - Drip Valve DV - Deluge Valve PG - Pressure Gauge SV - Solenoid Valve
F - Funnel ER - Emergency Release Box
To
C
Sprinkler
Alarm
To Open
Drain To Priming
Connection
D
To Drain
A B
Dimensions
Nominal Size A B C D E
DN (Inches) mm mm mm mm mm
2 350 450 700 450 410
3 350 450 700 450 410
EME/F/V/12/00
page 50
Deluge Valve
page 51
Deluge Valves
Cast Steel, Quick release, Hydraulically operated diaphram valve, Maximum operating
Pressure 175 PSI, Flange x Flange to ANSI B16.1 Class 125 FF. Threaded tapping
BSPT suitable for vertical or horizontal mounting, Globe pattern, Fire engine red epoxy
paint finish.
Pressure
Working cold non-shock pressure : 175 PSI
Hydrostatic test pressure : 350 PSI
Application
Deluge systems as per NFPA 13.
ECON Cast Steel Deluge
Options (Available on Request) Valve
Flange drilling to IS:1538
Fig . DVH 175 F
175 PSI / 12 bar
Accessories UL Listed
Dry Pilot basic trim
Wet Pilot basic trim
Electric trim
Test and alarm trim
Water motor alarm gong
Ordering Information
Size ( 3 " - 8")
Flange drilling
Trim options
Material Specification
No C omponent Material
01 Housing Cast Steel ASTM A 216 WCB
02 Lock Nut SS 304
03 Hex Nut SS 304
04 Seat Bronze IS:318 LTB - II / ASTM B 62
05 O - Ring Neoprene
06 Hex Head Bolt SS 304
07 Rubber Clamp Bronze IS:318 LTB - II / ASTM B 62
08 Rubber Seat Neoprene
09 O - Ring Neoprene
10 Spindle SS 304 / ASTM A 276 Type 304
11 Clapper Bronze IS:318 LTB - II / ASTM B 62
12 Diaphragm Neoprene
13 Clamp Ring Bronze IS:318 LTB - II / ASTM B 62
14 Hex Head Bolt SS 304
15 Spring SS 316
16 Hex Head Bolt IS:1363 / Steel ISO 4018 (Galvanized)
17 Spindle Adaptor Brass IS:319 - 1/ASTM B 16
18 O - Ring Cover Neoprene
19 O - Ring Cover Cast Steel ASTM A 216 Gr. WCB
20 Plug Chrome Plated
21 Hex Nut IS:1363 / Steel ISO 4018 (Galvanized)
4 412 290 67
6 462 321 99
8 552 360 177
page 52
Deluge Valves
Pneumatic and Electric Trim for Horizontal mounting for DVH 175 F
To Detection
To Sprinkler Line
Alarm
To Open
From Drain
Compressor
To Open
Drain
To Open
Drain
To Open
Drain
To Open
To Priming Drain
Connection
(Below Upstream
Stop Valve)
To Open
Drain
EME/F/V/12/00
page 53
Deluge Valves
Pneumatic and Electric Trim for horizontal mounting for DVH 175 F
Trim Components
Qty. Qty. Qty. Qty.
No Component Size DN80 DN100 DN150 DN200
01 Union ½" 2 2 2 2
02 Hex Nipple ½" 8 8 8 8
03 Ball Valve ½" 1 1 1 1
04 Elbow ½" 2 2 2 2
05 Y-Strainer ½" 1 1 1 1
06 Restriction Check Valve - 1 1 1 1
07 Tee ½" 4 4 4 4
08 Pipe Nipple ½" x 80 mm 1 1 1 1
09 Pipe Nipple ½" x 120 mm - - - 1
09 Pipe Nipple ½" x 100 mm 1 1 1 -
10 Emergency Release Station - 1 1 1 1
11 Dry Pilot Actuator - 1 1 1 1
12 Reducing Hex Nipple ½" x ¼" 3 3 3 3
13 Gauge Valve ¼" 2 2 2 2
14 Elbow ¼" 3 3 3 3
15 Pressure Gauge - 2 2 2 2
16 Hex Nipple 1" 1 1 1 1
17 Drip Valve - 2 2 2 2
18 Hex Nipple ¼" - 1 1 1
19 Hex Nipple 2" 1 - - -
19 Pipe Nipple 1 ¼" 1 - - -
20 Angle Valve 1 ¼" 1 1 1 1
21 Reducing Nipple ½" x ¼" x 65 mm 1 1 1 1
22 Reducing Tee 1" x ½" x 1" - - 1 1
23 Angle Valve 1" 1 1 - -
24 Reducing Hex Nipple ½" x ¼" 1 1 1 1
24 Reducing Nipple ½" x ¼" x 65mm 2 2 2 2
25 Plug ½" 1 1 1 1
26 Plug ¾" 1 1 1 1
27 Plug ½" 1 1 1 1
28 Plug ½" - - 1 1
29 Orifice Nozzle ½" 1 1 - -
T1 Pipe Nipple ¾" x 100 mm 1 1 1 1
T1 Pipe Nipple ¾" x 80 mm 2 2 2 2
T2 Elbow ¾" 1 1 1 1
T3 Hex Nipple ¾" 1 1 1 1
T4 Swing Check Valve ¾" 1 1 1 1
T5 Tee ¾" 1 1 1 1
T6 Reducing Hex Nipple ¾" x ½" - - - 1
T7 Ball Valve ½" - - 1 -
T8 Copper Tube with fitting ½" 1 1 - -
T8 Copper Tube with fitting ½" 1 1 1 1
T8 Copper Tube with fitting ½" 1 1 1 1
E1 Hex Nipple ½" 1 1 1 1
E2 Solenoid Valve ½" 1 1 1 1
P1 Pressure Switch ½" 1 1 1 1
P2 Tee ½" 1 1 1 1
P3 Hex Nipple ½" 1 1 1 1
EME/F/V/12/00
page 54
Deluge Valves
Hydraulic and Electric Trim for Horizontal mounting for DVH 175 F
To Sprinkler
Alarm
To Detection
Line
To Open
Drain
To Open
Drain
To Open
Drain
To Open
Drain
To Priming
Connection
(Below Upstream
Stop Valve)
To Open
Drain
EME/F/V/12/00
page 55
Deluge Valves
Hydraulic and Electric Trim for Horizontal mounting for DVH 175 F
Trim Components
Qty. Qty. Qty. Qty.
No Component Size DN80 DN100 DN150 DN200
01 Union ½" 1 1 1 1
02 Hex Nipple ½" 4 4 4 4
03 Ball Valve ½" 1 1 1 1
04 Elbow ½" 3 3 3 3
05 Y-Strainer ½" 1 1 1 1
06 Restriction Check Valve - 1 1 1 1
07 Tee ½" 2 2 2 2
08 Pipe Nipple ½" x 80 mm 1 1 1 1
09 Pipe Nipple ½" x 120 mm - - - 2
09 Pipe Nipple ½" x 100 mm - 2 2 -
10 Emergency Release Station - 1 1 1 1
11 Gauge Valve ¼" 2 2 2 2
12 Elbow ¼" 1 1 1 1
13 Pressure Gauge - 2 2 2 2
14 Hex Nipple 1" 2 2 2 2
15 Drip Valve - 1 1 1 1
16 Hex Nipple ¼" 1 1 1 1
17 Pipe Nipple 2" - 1 1 1
17 Pipe Nipple 1 ¼" 1 - - -
18 Angle Valve 2 - 1 1 1
18 Angle Valve 1 ¼" 1 - - -
19 Reducing Nipple ½" x ¼" x 65 mm 1 1 1 1
20 Reducing Tee 1" x ½" x 1" 1 1 1 1
21 Angle Valve 1" 1 1 1 1
22 Reducing Hex Nipple ½" x ¼" - - 1 1
22 Reducing Nipple ½" x ¼" x 85 mm 1 1 - -
23 Plug ½" 1 1 1 1
24 Plug ¾" 2 2 2 2
25 Plug ½" 1 1 1 1
26 Plug ½" 1 1 1 1
T1 Pipe Nipple ¾" x 100 mm - - 1 1
T1 Pipe Nipple ¾" x 80 mm 1 1 - -
T2 Elbow ¾" 1 1 1 1
T3 Hex Nipple ¾" 2 2 2 2
T4 Swing Check Valve ¾" 1 1 1 1
T5 Tee ¾" 1 1 1 1
T6 Reducing Hex Nipple ¾" x ½" 1 1 1 1
T7 Ball Valve ½" 1 1 1 1
T8 Copper Tube with fitting ½" - - - 1
T8 Copper Tube with fitting ½" - - 1 -
T8 Copper Tube with fitting ½" 1 1 - -
E1 Hex Nipple ½" 1 1 1 1
E2 Solenoid Valve ½" 1 1 1 1
EME/F/V/12/00
page 56
Deluge Valves
Hydraulic and Electric Trim for Vertical mounting for DVH 175 F
To Sprinkler
Alarm
** 39
36 37
38
24
35
37
14 23
34
To Open
13 33 Drain
*
*
32
15
17 31
27 22
16 30
21
29
14 21
To Open
20 Drain
13 18
19
25
26
6 To Open
16
12 26 Drain
2 26
2
7 10
8
1 9
4
2
9 To Detection
5
3 Line
#
#
To Priming 40
Connection 9
11 41
(Below Upstream 28
Stop Valve)
#
To Open To Open
# Drain
Drain
EME/F/V/12/00
page 57
Deluge Valves
Hydraulic and Electric Trim for Vertical mounting for DVH 175 F
Trim Components
Qty. Qty. Qty. Qty.
No Component Size DN200 DN150 DN100 DN80
1 Union ½” 1 1 1 1
2 Hex Nipple ½” 3 3 3 3
3 Pipe Nipple ½” x 60 mm - 1 1 1
3 Pipe Nipple ½” x 90 mm 1 - - -
4 Pipe Nipple ½” x 100 mm - - 1 1
4 Pipe Nipple ½” x 130 mm 1 1 - -
5 Ball Valve ½” 1 1 1 1
6 Elbow ½” 1 1 1 1
7 ‘Y’ type Strainer ½” 1 1 1 1
6 Restriction Check Valve - 1 1 1 1
9 Tee ½” 3 3 3 3
10 Pipe Nipple ½” X 80 mm 1 1 1 1
11 Emergency Release Station - 1 1 1 1
12 Reducing Hex Nipple ½”x ¼” 1 1 1 1
13 Gauge Valve ¼” 2 2 2 2
14 Pressure Gauge ¼” 2 2 2 2
15 Hex Nipple ¼” 1 1 1 1
16 Elbow ¼” 2 2 2 2
17 Reducing Nipple ¼” x ½” x 65 mm 1 1 1 1
18 Drip Valve - 1 1 1 1
19 Reducing Hex Nipple 1 x ½” 1 1 1 1
20 Tee 1” 1 1 1 1
21 Hex Nipple 1” 2 2 2 2
22 Angle Valve 1” 1 1 1 1
23 Pipe Nipple 2 1 ¼” x 80 mm 1 1 1 -
23 Pipe Nipple 1 ¼” x 80 mm - - - 1
24 Angle Valve 2” 1 1 1 -
24 Angle Valve 1 ¼” 1 - - 1
25 Pipe Nipple ¼” x 90 mm 1 1 1 1
26 Plug ½” 3 3 3 3
27 Plug ¾” 1 1 1 1
28 Plug ½” 1 1 1 1
Test and Alarm Trim (Optional)
29 Hex Nipple ½” 1 1 1 1
30 Elbow ½” 1 1 1 1
31 Copper Tube Assy. ½” 1 - - -
31 Copper Tube Assy. ½” - 1 - -
31 Copper Tube Assy. ½” - - 1 -
31 Copper Tube Assy. ½” - - - 1
32 Tee ½” 1 1 1 1
33 Hex Nipple ½” 1 1 1 1
34 Ball Valve ½” 1 1 1 1
35 Reducing Hex Nipple ¾” x ½” 1 1 1 1
36 Tee ¾” 1 1 1 1
37 Hex Nipple ¾” 2 2 2 2
38 Swing Check Valve ¾” 1 1 1 1
39 ‘Y’ Type Strainer ¾” 1 1 1 1
Electric Trim for Solenoid Valve (Optional)
40 Hex Nipple ½” 1 1 1 1
41 Solenoid Valve ½” Two Way 1 1 1 1
EME/F/V/12/00
page 58
Deluge Valves
Pneumatic and Electric Trim for Vertical mounting for DVH 175 F
To Sprinkler
Alarm
** 38
35 36
25
37
34 24
36
15
33 To Open
Drain
14 32 23
*
22
16
18
31
* 22
To Open
30
21 Drain
27 19
17 29 20
39
15
To Open
14 #
Drain
44
To Detection
4 From
26 Line
15 Compressor
6 #
17
13 26 8
26 14 43
2
2 42
7 10 13 #
9 #
8
2 2
1 9 9
2
1 12
2
2 2
1
5
9 To Open
2
3 Drain
To Priming 28 #
9
Connection 11 #
40
(Below Upstream
Stop Valve)
To Open # 41
To Open
Drain
# Drain
EME/F/V/12/00
page 59
Deluge Valves
Hydraulic and Electric Trim for Vertical mounting for DVH 175 F
Trim Components
Qty. Qty. Qty. Qty.
No Component Size DN200 DN150 DN100 DN80
1 Union ½” 3 3 3 3
2 Hex Nipple ½” 9 9 9 9
3 Pipe Nipple ½” x 60 mm - 1 1 1
3 Pipe Nipple ½” x 90 mm 1 - - -
4 Pipe Nipple ¼” x 90 mm 1 1 1 1
5 Ball Valve ½” 1 1 1 1
6 Elbow ½” 1 1 1 1
7 ‘Y’ Type Strainer ½” 1 1 1 1
8 Restriction Check Valve - 2 2 2 2
9 Tee ½” 5 5 5 5
10 Pipe Nipple ½” x 80 mm 1 1 1 1
11 Emergency Release Station - 1 1 1 1
12 Dry Pilot Actuator - 1 1 1 1
13 Reducing Hex Nipple ½” x ¼” 2 2 2 2
14 Gauge Valve ¼” 3 3 3 3
15 Pressure Gauge ¼” 3 3 3 3
16 Hex Nipple ¼” 1 1 1 1
17 Elbow ¼” 2 2 2 2
18 Reducing Nipple ¼” x ½” x 65 mm 1 1 1 1
19 Drip Valve - 1 1 1 1
20 Reducing Hex Nipple 1” x ½” 1 1 1 1
21 Tee 1” 1 1 1 1
22 Hex Nipple 1” 2 2 2 2
23 Angle Valve 1” 1 1 1 1
24 Pipe Nipple 2” x 80 mm 1 1 1 -
24 Pipe Nipple 1 ¼” x 80 mm - - - 1
25 Angle Valve 2” 1 1 1 -
25 Angle Valve 1 ¼” - - - 1
26 Plug ½” 3 3 3 3
27 Plug ¾” 1 1 1 1
28 Plug ½” 1 1 1 1
Test and Alarm Trim (Optional)
29 Elbow ½” 1 1 1 1
30 Copper Tube Assy. ½” 1 - - -
30 Copper Tube Assy. ½” - 1 - -
30 Copper Tube Assy. ½” - - 1 -
30 Copper Tube Assy. ½” - - - 1
31 Tee ½” 1 1 1 1
32 Hex Nipple ½” 1 1 1 1
33 Ball Valve ½” 1 1 1 1
34 Reducing Hex Nipple ¾” x ½” 1 1 1 1
35 Tee ¾” 1 1 1 1
36 Hex Nipple ¾” 2 2 2 2
37 Swing Check Valve ¾” 1 1 1 1
38 ‘Y’ Type Strainer ¾” 1 1 1 1
39 Hex Nipple ½” 1 1 1 1
Electric Trim for Solenoid Valve (Optional)
40 Hex Nipple ½” 1 1 1 1
41 Solenoid Valve ½” Two Way 1 1 1 1
Elctric Trim for Pressure Switch (Optional)
42 Hex Nipple ½” 1 1 1 1
EME/F/V/12/00
43 Tee ½” 1 1 1 1
44 Pressure Switch ½” 1 1 1 1
page 60
Deluge Valves
Pneumatic and Electric Trim for Vertical mounting for DVH 175 F
To Detection Line
To Detection Line
PG
From
G
PS RCV Compressor
From
Compressor
* Outlet
PG RCV
PG
DR.V
OD
RCV To Drain DPA * ~ PG
OD
OD DPA
M SV
PG
OD
G To
~ RCV Drain *
PV * OD
SV
DV M
OD
DV
From Inlet Inlet OD
Outlet
Supply PV
PG
DR.V
CD From
OD Supply
CD
Hydraulic and Electric Trim for Vertical mounting for DVH 175 F
To Detection Line G
* PG
RCV * ~
DR.V
OD
OD OD
M SV PG
PG
OD
G ~ To Detection Line
PV *
RCV *
OD
OD
SV
Inlet
DV
From DV M
Outlet
Supply
Inlet OD
PG
PV
DR.V
CD
OD
CD From
Supply
page 61
Deluge Valves
page 62
Pressure Gauge
Technical Data
Model ECON PG
Dial Size 90 MM (3.5")
Connection ¼" BSPT
(¼" NPT Optional)
Range 0-16 Kg./Sq. Cm and
0-250 PSI
Burdon Tube & Phosphorus Bronze
Movement Burdon tube and brass
movement
Dial Type White background
black graduation scale
with dual reading in Kg.
Pressure Gauge
/ Sq. Cm and PSI Fig. ECON PG
Case and Bazel Polished Stainless
Steel Case. Positive
seal against weather,
moisture and dust
8 10
Mounting Direct
12
150
Window Hardened Glass 100
14
Accuracy +/- 2% of FSD for 50 200
16
250
Kg/cm2
Weight (Approx) 0.3 Kg AIR/WATER
psi
0
PRESSURE GAUGE FOR
LISTED FIRE PROTECTION
SERVICE
Approval UL Listed 40 BN
MODEL - ECON PG
1/4" BSPT
MODEL-ECON PG Pressure Gauges are specifically designed for Fire Sprinkler Services. The
pressure gauge is UL Listed. It has a corrosion resistant stainless steel case as well as Bazel and
Brass wetted parts. The dial has pressure reading in KG/SQCM and PSI. The gauge window is
made of hardened glass.
31
The pressure gauge must be mounted by square provided for spanner grip on the socket and
not by turning the case. Turning of the case will damage the gauge. Use PTFE tape around male
threads of the gauge for sealing. Pressure gauge must be mounted in vertical position and
isolated with valve or cock. The pressure gauge must be handled with due care. For best results,
the storage as well as any further shipment be made in original packing only.
Ø100
The pressure gauge, which is visibly damaged, should not be installed. It is recommended that
the pressure gauges must be inspected regularly for possible corrosion or damage. The gauge
must be periodically calibrated as per requirement of NFPA/TAC or as per the local authority
having jurisdiction.
EME/F/V/12/00
page 63
High Velocity Water Spray Nozzle
Technical Data
Model HV-A, HV-AS
Maximum Working 12 Kg./Sq.Cm. (175 PSI) (12 Bar)
Pressure
Effective 3.5 to 10.5 Bar
Working Pressure (50 - 150 PSI)
End Connection ¾" BSPT
(¾" NPT Optional)
Material Housing & Scroll-Brass High Velocity Water
(Equivalent to Astm B21) Spray Nozzle (Brass)
Included Water Spray K-factor Fig. HV - A
Spray Angle and Angle Metric (US)
K-factor 75° - 22 (1.54)
80° - 18 (1.26)
90° - 32 (2.24)
100° - 26 (1.82) C
115° - 42 (2.94)
120° - 23 (1.61)
A
Weight (Approx) 0.200 Kg
Finish Brass Finish
Nickel Chrome Plated (optional)
Ordering Specify Model, K-Factor,
Information Spray angle and Finish 3/4" BSPT
Description
High Velocity Water Spray Nozzles are internal swirl plate type open nozzles designed for use in
fixed water spray or deluge system for the fire protection application.
These nozzles produce solid uniform and dense core of high velocity water spray to effect fire
control. Nozzles are normally used to cool the surface as well as for extinguishment. Nozzles are
typically used for Deluge protection of special hazards such as oil filled transformers, switch-
gear, chemical process equipments, conveyor system and flammable liquid storage areas. The
minimum desirable pressure to achieve a reasonable spray pattern is 3.5 Kg./sq.cm. (50 psi). The High Velocity Water
water distribution pattern is giving maximum effective axial distance from the nozzle. The system Spray Nozzle (Brass)
designer must consider wind velocity while designing the system for outdoor application. Field
obstruction if any affecting the spray pattern of the nozzle must be considered.
Fig. HV - AS
The nozzle may be oriented in any position as deemed necessary to cover the hazard.
3.5 bar to 7 bar pressure at Nozzle is recommended for effective application requiring High
Velocity Water delivery for rapid extinguishment of all fires by emulsification. The main pipeline
strainers are required in the system. The Blow-off cap can be used to prevent the deposting
of foreign material in the water way of the nozzle. Use of Blow-off cap is optional and not UL
A
listed.
Maintenance
The spray nozzle must be handled with due care. For best results , the storage as well as any
further shipment be made in original packing only.
B
Nozzle which is visibly damaged should not be installed. Use Teflon tape or soft thread sealant
on the male thread of the nozzle.
EME/F/V/12/00
page 64
High Velocity Water Spray Nozzle
K 22 x 75° 49 30
K 18 x 80° 44 30
K 32 x 90° 49 30
K 26 x 100° 55 30
K 23 x 120° 49 30
K 42 x 115° 49 30
Discharge Characteristics
Pressure in PsI
30 60 90 120 150 175
140
120
K42
30
100
K32
Q = Flow in LPM
Flow in GPM
K26
80 K23 20
K22
60
K18
40 10
20
0 2 4 6 8 10 12
P - Pressure in Kg./Sq.Cm.
blockage if any. The nozzle should be cleaned or replaced if required. The system must be operated with optimum water
flow at least three times in a year or as per the provision of NFPA / TAC or local authority having jurisdiction.
The owner is solely responsible for maintaining the water spray system and components therein, so that it performs
properly when required.
EME/F/V/12/00
page 65
Medium Velocity Water Spray Nozzle
Technical Data
Model MV-E
Maximum Working 12 Bar (175 PSI)
Pressure
Effective Working 1.4 to 3.5 Bar
Pressure (20 - 50 PSI)
End Connection ½" BSPT
(½" NPT Optional)
Material Refer Table
Included Water 140°, 120°, 110°, 100°,
Spray Angle For 90°, 80°, 65°
Each K-factor
Orifice Size And mm (Inch) Metric (US)
K-factor 6.3( 0.248) - K18(1.26) **
6.0 (0.236) - K22 (1.54)
7.0 (0.275) - K30 (2.10) ECON Medium Velocity
7.5 (0.295) - K35 (2.45)
8.0 (0.314) - K41 (2.87) Water Spray Nozzle
9.0 (0.354) - K51 (3.57) (Aluminium Bronze)
10.0 (0.393)- K64 (4.48) Fig . MV - E
11.0 (0.433)- K79 (5.53)
12.0 (0.472)- K91 (6.37)
12.5 (0.492)- K102(7.14)
**K-18 nozzle is with square edge orifice, others with tapered bore.
46±2
Weight (Approx) 0.115 Kg
Finish Natural Brass finish,
Chrome plated brass,
Electroless Nickel plated,
Epoxy powder coated
64±2
Approvals UL Listed
Ordering Specify K-Factor, Spray
Information Angle, Finish, Model and
end Connection
Description
The Econosto Medium Velocity Water Spray Nozzles are open type (non-automatic)
nozzles, designed for directional spray application in fixed fire protection system.
Medium velocity water spray nozzle has an external deflector, which discharges water in
a directional cone shaped pattern of small droplet size. The water is uniformly distributed
over the surface to be protected.
The Nozzles are effectively designed to apply water to exposed vertical, horizontal, curved
and irregular shaped surfaces to allow cooling to prevent excessive absorption of heat
from an external fire and avoid structural damage or spread of fire. In some application,
nozzles may be installed to control or extinguish the fire depending on the water design
density as per applicable codes.
The nozzle is used in deluge water spray system for special hazard fire protection
application.
As the design and intent of specific water spray system may vary considerably, MV-E Nozzle
is made available in several combination of orifice sizes and spray angles.
The minimum desirable pressure to achieve a reasonable spray pattern is 1.4 Kg./Sq.cm.
The water distribution pattern is at an average pressure of 2.0 Kg/Sq.cm. The change in
EME/F/V/12/00
pressure between 1.4 to 3.5 Kg./sq.cm. does not affect considerable change in spray angle.
System designer must consider wind velocity while designing the system for outdoor
page 66
Medium Velocity Water Spray Nozzle
Model MV - E
Table - Material of Construction
Discharge Characteristics
Flow in GPM
10 20 30 40 50 60 70
7 100
02
P - Pressure in Kg./Sq.Cm
K41
K18
K30
K1
6
K35
1
K22
80
1
K9
4
K5
9
K6
K7
Pressure in PSI
5
4 60
3
40
2
20
1
0
0 20 60 100 140 180 220 260 300
QQ--DISCHARGE
Discharge -- LPM
LPM from
FROMNozzle
NOZZLE
Q =K P where P is supply pressure in Kg/sq.cm., K= nozzle constant (K-factor) in metric
USsupply
Q =K√P where P is K factor = Metric
pressure K factorK= nozzle
in Kg/sq.cm., 14.2745constant (K-factor) in metric
US K factor = Metric K factor ÷ 14.2745
application. Field obstruction if any affecting the spray pattern of the nozzle must also be considered. The nozzle
may be oriented to any position as deemed necessary to cover the hazard.
The Blow-off plugs can be used to prevent the depositing of foreign materials in the water way of the nozzles,
which could interfere with the discharge of spray nozzle. Blow -off plugs is optional and are not UL listed.
The main pipeline strainer as per NFPA-15 are required for system utilizing nozzle orifice diameter less than 9.5mm
(3/8 inch), i.e. Econosto Nozzle having K-factor 51 and less, and also for the system water which is likely to contain
obstructive materials.
Maintenance
The spray nozzle must be handled with due care. For best results, the storage as well as any further shipment must
be made in original packing only.
Use Teflon tape or soft thread sealant on male thread of the nozzle. The nozzles must be hand tightened into the
fitting. Excessive tightening torque may result into serious damage to nozzle arms and the deflector which may
affect spray pattern of the nozzle and it’s performance.
It is recommended that water spray system be inspected regularly by authorised technical personnel. The nozzle
must be checked for atmospheric effects, external and internal obstruction, blockage if any. The nozzle should be
cleaned or replaced if required. The system must be operated with optimum water flow at least twice in a year or as
per the provisions of NFPA/TAC or local authority having jurisdiction. The owner is solely responsible for maintaining
EME/F/V/12/00
the water spray system and the components therein so that it performs properly when required.
page 67
Medium Velocity Water Spray Nozzle
Technical Data
Model MV - A without Strainer
MV - AS with Strainer
Maximum Working Pressure 12 Bar (175 PSI)
Effective Working Pressure 1.4 To 3.5 Bar
(20 - 50 PSI)
End connection ½" BSPT
(½" NPT Optional)
Material Refer Table
Included Water 140°, 120°, 110°, 100°,
spray Angle for 90°, 80° & 65°
each K-factor
Orifice size and mm(Inch) Metric (US)
K-factor 6.3 (0.248) - K18 (1.26)**
6.0 (0.236) - K22 (1.54)
7.0 (0.275) - K30 (2.10)
7.5 (0.295) - K35 (2.45)
8.0 (0.314) - K41 (2.87) ECON Medium Velocity
9.0 (0.354) - K51 (3.57)
10.0 (0.393) - K64 (4.48)
Water Spray Nozzle
11.0 (0.433) - K79 (5.53) (Aluminium Brass)
12.0 (0.472) - K91 (6.37) Fig. MV - A, MV - AS
12.5 (0.492) - K102 (7.14)
(Only K-factors K-18, K-22, K-30, K-35 & K-41
are available with Strainer in model-AS)
**K-18 Nozzle is with square edge orifice, others with tapered bore.
MV - A
Weight (Approx) 0.115 Kg 46±2
Finish Natural Brass finish,
Chrome plated brass,
Electroless Nickel Plated,
Epoxy powder coated
Approvals UL Listed
64±2
Ordering Specify K-factor, Spray
Information Angle, Finish, Model and
end connection
Description
The Econosto Medium Velocity Water Spray Nozzles are open type (non-automatic) nozzles,
designed for directional spray application in fixed fire protection system. MV - AS
46±2
Medium velocity water spray nozzle has an external deflector, which discharges water in
a directional cone shaped pattern of small droplet size. The water is uniformly distributed
over the surface to be protected.
The Nozzles are effectively designed to apply water to exposed vertical, horizontal, curved
and irregular shaped surfaces to allow cooling which prevents excessive absorption of
heat from external fire and in turn prevents structural damage or spread of fire. In some
applications the nozzles may be installed to control or extinguish the fire depending on
84±2
water design density as per applicable codes. The nozzle is used in deluge water spray
system for special hazard fire protection application. As the design and intent of specific
water spray system may vary considerably, MV-A nozzle is made available in several
combinations of orifice sizes and spray angles.
The minimum desirable pressure to achieve a reasonable spray pattern is 1.4 Kg./Sq.Cm.
The water distribution pattern is at an average pressure of 2.0 Kg/Sq.Cm. The change in
pressure between 1.4 to 3.5 Kg./Sq.Cm. does not considerably change the spray angle.
System designer must consider wind velocity while designing the system for outdoor
applications. Field obstruction if any affecting the spray pattern of the nozzle must also be
EME/F/V/12/00
considered. The nozzle may be oriented to any position as deemed necessary to cover the
hazard. Blow-off plugs can be used to prevent the depositing of foreign materials in the
page 68
Medium Velocity Water Spray Nozzle
Model MV - A, Model MV - AS
Table - Material of Construction
Housing Forged Brass - Equivalent to ASTM B21 Forged Brass - Equivalent to ASTM B21
Discharge Characteristics
Flow in GPM
P - Pressure in Kg./Sq.Cm
Pressure in PSI
water way of the nozzles which could interfere with discharge of the spray nozzle. Blow-off plugs are optional and
are not UL listed.
The main pipeline strainer as per NFPA-15 is required for system utilizing nozzle orifice diameter less than 9.5mm
(3/8 inch), i.e. Econosto Nozzle having K-factor 51 and less, and also for the system where water is likely to contain
obstructive materials.
Maintenance
The spray nozzle must be handled with due care. For best results, the storage as well as any further shipment
be made in original packing only. Nozzle which is visibly damaged should not be installed. Use Teflon tape or
soft thread sealant on male thread of the nozzle. The nozzles must be hand tightened into the fitting. Excessive
tightening torque may result into serious damage to nozzle arms and the deflector which may affect spray pattern
of the nozzle and it’s performance. It is recommended that water spray system be inspected regularly by authorised
technical personnel. The nozzle must be checked for atmospheric effects, external and internal obstruction or
blockages if any. The system must be operated with optimum water flow at least twice in a year or as per the
provisions of NFPA /TAC or local authority having jurisdiction. The owner is solely responsible for maintaining the
EME/F/V/12/00
water spray system and the components there in so that it performs properly when required.
page 69
/>LiÃ
Flange dim., ASME B16.5 (½" - 2½")
Tables - Flange dim., ASME B16.5 (12”-
(½” - 2½”)
24”)
½" A 3½ 88.9 3.75 95.2 3.75 95.2 4.75 121 4.75 121 5.25 133.4
b 42552 11.1 Ñ 14.3 Ñ 14.3 ¿ 22.2 ¿ 22.2 1.1875 30.2
D2 1Ä 34.9 1Ä 34.9 1Ä 34.9 1Ä 34.9 1Ä 34.9 1Ä 34.9
D1 2.375 60.3 2.625 66.7 2.625 66.7 3.25 82.6 3.25 82.6 3½ 88.9
n 4 4 4 4 4 4 4 4 4 4 4 4
d Å 15.9 Å 15.9 Å 15.9 ¿ 22.2 ¿ 22.2 ¿ 22.2
¾" A 3.875 98.4 4.625 117.5 4.625 117.5 5Ã 130 5Ã 130 5.5 139.7
b ½ 12.7 Å 15.9 Å 15.9 1 25.4 1 25.4 1¼ 31.8
D2 1Ô 42.9 1Ô 42.9 1Ô 42.9 1Ô 42.9 1Ô 42.9 1Ô 42.9
D1 2.75 69.8 3.25 82.5 3.25 82.5 3½ 88.9 3½ 88.9 3.75 95.2
n 4 4 4 4 4 4 4 4 4 4 4 4
d Å 15.9 ¾ 19 ¾ 19 ¿ 22.2 ¿ 22.2 ¿ 22.2
1 " A 4.25 108 4.875 123.8 4.875 123.8 5.875 149.2 5.875 149.2 6.25 159
b Ñ 14.3 Ô 17.5 Ô 17.5 1Ã 28.6 1Ã 28.6 1Ä 34.9
D2 2 50.8 2 50.8 2 50.8 2 50.8 2 50.8 2 50.8
D1 3Ã 79.4 3½ 88.9 3½ 88.9 4 102 4 102 4.25 108
n 4 4 4 4 4 4 4 4 4 4 4 4
d Å 15.9 ¾ 19 ¾ 19 1 25.4 1 25.4 1 25.4
1¼" A 4.625 117.5 5.25 133.4 5.25 133.4 6.25 159 6.25 159 7.25 184.2
b Å 15.9 ¾ 19 Õ 20.6 1Ã 28.6 1Ã 28.6 1½ 38.1
D2 2½ 63.5 2½ 63.5 2½ 63.5 2½ 63.5 2½ 63.5 2½ 63.5
D1 3½ 88.9 3.875 98.4 3.875 98.4 4.375 111 4.375 111 5Ã 130
n 4 4 4 4 4 4 4 4 4 4 4 4
d Å 15.9 ¾ 19 ¾ 19 1 25.4 1 25.4 1Ã 28.6
2 " A 6 152.4 6.5 165.1 6.5 165.1 8.5 215.9 8.5 215.9 9.25 234.9
b ¾ 19 ¿ 22.2 1 25.4 1½ 38.1 1½ 38.1 2 50.8
D2 3.625 92.1 3.625 92.1 3.625 92.1 3.625 92.1 3.625 92.1 3.625 92.1
D1 4.75 121 5 127 5 127 6.5 165.1 6.5 165.1 6.75 171
n 4 4 8 8 8 8 8 8 8 8 8 8
d ¾ 19 ¾ 19 ¾ 19 1 25.4 1 25.4 1Ã 28.6
2½" A 7 177.8 7.5 190.5 7.5 190.5 9.625 244 9.625 244 10.5 266.7
b ¿ 22.2 1 25.4 1Ã 28.6 1Å 41.3 1Å 41.3 2.25 57.2
D2 4.125 104.8 4.125 104.8 4.125 104.8 4.125 105 4.125 105 4.125 105
D1 5.5 139.7 5.875 149.2 5.875 149.2 7.5 190.5 7.5 190.5 7.75 197
n 4 4 8 8 8 8 8 8 8 8 8 8
d ¾ 19 ¿ 22.2 ¿ 22.2 1Ã 22.2 28.6 28.6 1¼ 31.8
EME/F/V/12/00
£ÓxÉ£xäÊLãÓxÉ£xäÊLÃ
ÎääÊLà ÎääÊLÃÈääÊLà ÈääÊLÃääÊLà ääÊLÃ
£xääÊLà £xääÊLÃÓxääÊLà ÓxääÊLÃ
QV
iÃR QR
QV
iÃRQV
iÃR
QR QR
QV
iÃR
QV
iÃR
QR QR
QV
iÃR
QV
iÃR
QR QR
QV
iÃR
QV
iÃR
QR QR
QV
iÃR
QV
iÃR
QR QR
QV
iÃR QR
3 " A 7.5 190.5 8.25 209.6 8.25 209.6 9.5 241 10.5 267 12 305
b Ð 23.8 1Ã 28.6 1¼ 31.8 1½ 38.1 1¿ 47.6 2.625 66.7
D2 5 127 5 127 5 127 5 127 5 127 5 127
D1 6 152.4 6.625 168.3 6.625 168.3 7.5 190.5 8 203 9 228.6
n 4 4 8 8 8 8 8 8 8 8 8 8
d ¾ 19 ¿ 22.2 ¿ 22.2 1 25.4 1¼ 31.8 1Ä 34.9
4 " A 9 228.6 10 254 10.75 273 11.5 292 12.25 311 14 356
b Ð 23.8 1¼ 31.7 1½ 38.1 1.75 44.4 2.125 54 3 76.2
D2 6.1875 157.2 6.1875 157.2 6.1875 157.2 6.1875 157.2 6.1875 157.2 6.1875 157.2
D1 7.5 190 7.875 200 8.5 215.9 9.25 235 9.5 241 10.75 273
n 8 8 8 8 8 8 8 8 8 8 8 8
d ¾ 19 ¿ 22.2 1 25.4 1¼ 31.8 1Ä 34.9 1Å 41.3
5 " A 10 254 11 279.4 13 330.2 13.75 349 14.75 375 16.5 419
b Ð 23.8 1Ä 34.9 1.75 44.4 2 50.8 2.875 73 3.625 92.1
D2 7.3125 185.7 7.3125 185.7 7.3125 185.7 7.3125 185.7 7.3125 185.7 7.3125 185.7
D1 8.5 215.9 9.25 234.9 10.5 266.7 11 279 11.5 292 12.75 324
n 8 8 8 8 8 8 8 8 8 8 8 8
d ¿ 22.2 ¿ 22.2 1Ã 28.6 1Ä 34.9 1Å 41.3 1¿ 47.6
8 " A 13.5 342.9 15 381 16.5 419 18.5 470 19 482.6 21.75 552
b 1Ã 28.6 1Å 41.3 2.1875 55.6 2½ 63.5 3.625 92.1 5 127
D2 10.625 269.9 10.625 269.9 10.625 269.9 10.625 269.9 10.625 269.9 10.625 269.9
D1 11.75 298.4 13 330.2 13.75 349.2 15.5 394.2 15.5 394.2 17.25 438
n 8 8 12 12 12 12 12 12 12 12 12 12
d ¿ 22.2 1 25.4 1¼ 31.8 1½ 38.1 1.75 44.5 2.125 54
10 " A 16 406.4 17.5 444.5 20 508 21.5 546 23 584 26.5 673
b 1.1875 30.2 1¿ 47.6 2½ 63.5 2.75 69.8 4.25 108 6.5 165
D2 12.75 323.8 12.75 323.8 12.75 323.8 12.75 323.8 12.75 323.9 12.75 323.9
D1 14.25 361.9 15.25 387.4 17 431.8 18.5 470 19 482.6 21¼ 540
n 12 12 16 16 16 16 16 16 12 12 12 12
d 1 25.4 1Ã 28.6 1Ä 34.9 1½ 38.1 2 50.8 2.625 66.7
EME/F/V/12/00
xÊÊUÊÊ/>LiÃÊ}iiÀ>
xÊÊUÊÊ/>LiÃÊ}iiÀ> <ä£ä <ä£ä «>}iÊ£Ó£È
«>}iÊ£Ó£È
page 71
/>LiÃ
Flange dim., ASME B16.5 (12"- 24")
Tables - Flange dim., ASME B16.5 (12”- 24”)
16" A 23.5 596.9 25.5 647.7 27 686 27.75 705 32.5 826
b 1.4375 36.5 2.25 57.2 3 76.2 3½ 88.9 5.75 146
D2 18.5 470 18.5 470 18.5 470 18.5 470 18.5 470
D1 21¼ 539.8 22.5 571.5 23.75 603.3 24.25 616 27.75 705
n 16 16 20 20 20 20 20 20 16 16
d 1Ã 28.6 1Ä 34.9 1Å 41.3 1.75 44.5 2.625 66.7
20" A 27.5 698.5 30.5 774.7 32 813 33.75 857 38.75 984
b 1.0625 42.9 2½ 63.5 3½ 88.9 4.25 108 7 178
D2 23 584.2 23 584.2 23 584.2 23 584.2 23 584.2
D1 25 635 27 685.8 28.5 724 29.5 749.3 32.75 832
n 20 20 24 24 24 24 20 20 16 16
d 1¼ 31.8 1Ä 34.9 1.75 44.5 2.125 54 3Ã 79.4
Abbreviations
UL – Underwriters Laboratory.
FM – Factory Mutual.
NFPA – National Fire Protection Association.
ANSI – American National Standards Institute.
AWWA – American Water Works Association.
EME/F/V/12/00
page 73
Sharj
ah – U.A.E. Abu Dhabi– U.A.E. Doha -QATAR Dammam -K.S.A. Jeddah – KSA
P.O.Box3115 P.O.Box70187 Logisti
csVill
age Qatar P.O.Box37,Dammam 31411 P.O.Box812,Jeddah 21421
T:+971 6 5686471 T:+971 2 6334500 Zone 91 -W adiAbu Seleel T:+966 3 8595091 T:+966 2 2632824
F:+971 6 5686472 F:+971 2 6334501 AlW ukai
r F:+966 3 8592739 F:+966 2 2632824
E:econosto@ econosto.ae E:econosto@ econadh.ae T:+974 44672666 24 Hrs:+966 50 5862949 24Hrs:+966-50-5584663
M:+974 55861984 E:econosto@ sahara.com.sa E:stanlyg@ sahara.com.sa
E:ni
nesh@ econosto-mideast.ae
page
page137
page 13
28