Standard assembly of IF connector(China manufacture)

This standard is suitable for current Chinese suppliers product. Any


modification in design and construction will be noticed and lead to
different assembly.















clamp




Step-3
If the connector Pin very loose,then
Use the plier to clamp the Pin.
Step-1
8D-FB connector Pin
Step-2
Use the short conductor insert into the
connector Pin,and check it whether very
loose.
Step-4
The Pin had already been clamped
For tight.











Step-5
Lock nut,flat ring,and rubber gasket
Insert into IF cable.
Step-6
Remove outer insulator about 30mm.
Step-7
Shave off outer inaulator about 10mm
to taper.
Step-8
Shaves to taper on the side edge.













Step-9
Insert clamp ring into outer
strongly.outer end is stuck out about
0.5mm from edge of clamp ring.
Step-10
If outer is 0.5mm or more,cut out extra
rubbish by knife when clamp ring
strongly inserted.
Step-11
Fold back braided ahield and trim cut
Step-12
Cut aluminum shield in about half and
divided



For H type connectors









Step-13
Fold back aluminum shield
Step-14(H type)
Overlaps aluminum with braided shield
and trim cut
Step-15(H type)
Cut outinner insulator from the root











Step-16(H type)
Remove inner insulator
Step-17(H type)
Cut center conductor in 17mm,Taper
the end of center conductor using file


















Step-18 (H type)
Insert metal bush/insulator to center
conductor.
Step-19 (H type)
Set metal bush/insulator in the
connector correctly.
Step-20 (H type)
Insert cable straight in the connector
so that the center conductor may
enter a center pin.

















Step-21 (H type)
Tightening turns by lock nut. Turn only lock nut.
Don't turn connector side.
Space between lock nut and connector, 1.5mm is limits.
Dont tighten lock nut strongly.
If the locknut is tightened very strongly, Outer shield will be torn off in the connector.

Completed

For L type connectors











Step-14 (L type)
Insert metal bush to center conductor.

Step-15 (L type)
Insert metal bush to close the shield.

Step-16 (L type)
Cut out inner insulator from the root

Step-17(L type)
Cut center conductor in 12mm,Taper the end
of center conductor using file











Step-18 (L type)
First Insert metal bush to connector,
Insert cable straight into theconnector so that the
center conductor may enter a center pin.

Step-19 (L type)
Tighten lock nut.
Don't turn connector side. Turn only lock nut.
Space between lock nut and connector, 1.5mm is limits.
Dont tighten lock nut strongly.
If lock nut is tightened very strongly, Outer shield will be torn off in the connector.

completed
Note in Installation:














When the IF cable connect to IDU and ODU
Must orderliness the IF cable befor tighten the connector