Professional Documents
Culture Documents
Main
Main
ALCATEL
1521 FL & 1531 FL
4x2 or 16x2 Mbit/s
March 2000
Page 0-1
Table of Contents
GLOSSARY .......................................................................................0-13
1.GENERAL INFORMATION............................................................... 1-1
1.1 Introduction............................................................................... 1-3
1.2 Basic function ............................................................................ 1-3
1.3 Single fibre operation ................................................................ 1-4
1.4 Functional Features.................................................................... 1-4
1.5 Functional Layout of 1521/31 FL Equipment ............................... 1-5
1.6 Optical Fibre Line Terminal Equipment (OFLTE) ........................... 1-6
1.6.1 Transmission functions 1521 FL ........................................... 1-7
1.6.2 Transmission functions 1531 FL ........................................... 1-8
1.6.3 Internal Supervision Functions (ISS)....................................... 1-8
1.6.4 Transmission Test Functions ................................................. 1-8
1.7 Alarms and Supervision.............................................................. 1-9
1.7.1 Common Network Controller Circuit (CNCC) ....................... 1-9
1.8 Equipment Configuration ......................................................... 1-10
1.8.1 1521/31 FL T9 related equipment ..................................... 1-10
1.8.2 1521/31 FL S9 related equipment ..................................... 1-12
1.8.3 1521 FL DT/1U Customer Line Terminal Equipment ............ 1-14
1.8.4 1531 FL 3U Customer Line Terminal Equipment ................. 1-16
1.8.5 Power Unit for 1531 FL 3U................................................ 1-17
1.9 Installation .............................................................................. 1-18
1.9.1 1521/31 FL T9 installation ................................................ 1-18
1.9.2 1521/31 FL S9 installation ................................................ 1-19
1.9.3 1521 FL DT/1U installation................................................ 1-19
1.9.4 531 FL 3U installation ....................................................... 1-20
1.9.5 Configuration from HHT or from ECT/OCT via CNCC......... 1-20
1.9.6 Installation tests ................................................................ 1-20
1.10 Operation and Maintenance .................................................. 1-21
1.10.1 Visual LED indications ..................................................... 1-21
1.10.2 Handheld Terminal Display for each OFDLS ..................... 1-21
1.10.3 Reporting to CNCC ........................................................ 1-22
1.10.4 Protected Monitoring Points (PMP) .................................... 1-22
1.10.5 Test Configurations ......................................................... 1-22
1.10.6 Protection Fuses.............................................................. 1-22
1.10.7 Protection Switching ........................................................ 1-22
2. SYSTEM DESCRIPTION .................................................................. 2-1
2.1 General.................................................................................... 2-2
2.1.1 Functionality for previous and current 1521/31 FL equipment 2-2
2.1.2 Optical Line Modulation Signal 1521 FL............................... 2-2
2.1.3 Optical Line Modulation Signal 1531 FL............................... 2-3
2.1.4 Internal Service Channel ..................................................... 2-3
2.1.5 Muldex Functions................................................................ 2-3
2.1.6 Tributary Ports .................................................................... 2-3
2.1.7 Control and Supervision Functions ....................................... 2-4
3AG 20602 ABAA
Page 0-2
Page 0-3
Page 0-4
Page 0-5
Page 0-6
Page 0-7
Table of Figures
Figure 1.1 1531 FL 16x 2 Mbit/s system................................................... 1-3
Figure 1.2 Functional 1521/1531 FL Layout ............................................. 1-5
Figure 1.3 Functional layout of a 1521 FL T9/S9....................................... 1-6
Figure 1.4 Functional layout of a 1521 FL DT/1U...................................... 1-6
Figure 1.5 Functional layout of a 1531 FL 3U. .......................................... 1-7
Figure 1.6 CNCC block diagram............................................................. 1-9
Figure 1.7 1511 AN shelf ..................................................................... 1-11
Figure 1.8 1521/31 FL T9 and CNCC T9 front layout ............................. 1-11
Figure 1.9 1521/31 FL S9 shelf ............................................................. 1-12
Figure 1.10 1521 FL S9, 1531 FL S9 and CNCC S9 front layout.............. 1-13
Figure 1.11 1521 FL DT........................................................................ 1-14
Figure 1.12 1521 FL 1U ....................................................................... 1-15
Figure 1.13 Front Panel of 1531 FL 3U Customer Line Terminal .............. 1-16
Figure 1.14 Access Panel of 1531 FL 3U Customer Line Terminal ............ 1-17
Figure 1.15 Access Panel of Power Unit.................................................. 1-17
Figure 2.1
Figure 2.2
Figure 2.3
Figure 2.4
Figure 2.5
Figure 2.6
Figure 2.7
Figure 2.8
Page 0-8
Figure 4.3 The 1521/31 FL S9 shelf dry loop alarm outputs....................... 4-5
Figure 4.4 The S9 shelf common URG-, NURG- and ATT- alarms .............. 4-6
Figure 4.5 CNCC alarm inputs................................................................ 4-6
Figure 4.6 CNCC alarm-lamp drivers...................................................... 4-6
Figure 4.7 CNCC alarm relay outputs...................................................... 4-6
Figure 4.8 S9 shelf Q2 bus connector ..................................................... 4-7
Figure 4.9 Auxiliary Channels Connector ................................................. 4-7
Figure 4.10 V.11 APS 1+1 adapter 120 ............................................... 4-7
Figure 4.11 75 shelf jumper setting for 1521 FL S9 tributaries................ 4-8
Figure 4.12 120 shelf DIP-switches for trib. and aux. channels. .............. 4-9
Figure 4.13 Tributary pin allocation for 50 pin D-SUBs............................ 4-10
Figure 4.14 75 - 120 adapter............................................................ 4-11
Figure 4.15 RJ45 D-SUB adapter ........................................................ 4-11
Figure 4.16 Tributary pin allocation 1521 FL vs. 1531 FL ........................ 4-12
Figure 4.17 Backplane DIP switch to tributary analogy ............................ 4-13
Figure 4.18 Circuit diagram for backplane tributary interfaces................. 4-15
Figure 4.19 1521 FL S9 card ................................................................ 4-17
Figure 4.20 Optical interface module, Rx or Tx ....................................... 4-18
Figure 4.21 1531 FL S9 card ................................................................ 4-19
Figure 4.22 Front view CNCC S9 .......................................................... 4-21
Figure 4.23 Layout of the CNCC S9 ...................................................... 4-23
Figure 5.1 1521 FL Desktop.................................................................... 5-3
Figure 5.2 1521 FL DT wall mounted....................................................... 5-4
Figure 5.3 Wall mounting fixture ............................................................. 5-5
Figure 5.4 Mains adapter ....................................................................... 5-5
Figure 5.5 1521 FL DT/1U Power socket .................................................. 5-6
Figure 5.6 1521 FL DT/1U alarm in-/out-puts .......................................... 5-6
Figure 5.7 Auxiliary alarm inputs ............................................................. 5-7
Figure 5.8 Auxiliary alarm outputs ........................................................... 5-7
Figure 5.9 Auxiliary Channels Connector ................................................. 5-8
Figure 5.10 Tributary 120 interface connector....................................... 5-8
Figure 5.11 X.21 tributary interface connector .......................................... 5-9
Figure 5.12 1+1 Protection cabling 1521 FL DT/1U ............................... 5-10
Figure 5.13 Tributary APS 1+1 Desktop Cable 75 ............................... 5-11
Figure 5.14 Tributary APS 1+1 Desktop Cable 120 ............................. 5-12
Figure 5.15 Tributary 1+1 Protection Cable X.21.................................... 5-12
Figure 5.16 V.11 APS 1+1 DT Cable 120 .......................................... 5-13
Figure 5.17 1521 FL DT cabinet ............................................................ 5-14
Figure 5.18 Installation of Back-up Battery ............................................. 5-15
Figure 6.1
Figure 6.2
Figure 6.3
Figure 6.4
Figure 6.5
Figure 6.6
Figure 6.7
Page 0-9
Page 0-10
Table of Tables
Table 2.1
Table 2.2
Table 2.3
Table 2.4
Table 2.5
Table 2.6
Table 2.7
Table 3.1
Table 3.2
Table 3.3
Table 3.4
Table 3.5
Table 3.6
Table 3.7
Table 3.8
Table 3.9
Page 0-11
Page 0-12
Glossary
6B/8B
ABER
AC
AIS
APS
AUXP
BAT
BER
BIDL
DC
DCE
DFB
DIP
DL
DLASA
DLASB
DTE
ECT
EOW
CNCC
CO
CRC-4
HBERA
HBERB
HDB3
HDSL
HHT
ICS
ISDN
ITU-T
LBER
LBERA
LBERB
LBV
LD
LED
LFA
LMF
LOS
LOS34
LPS
LTE
MD
MF
NC
Laser Diode
Light Emitting Diode
Loss of Frame (BF) Alignment
Loss of Multiframe Alignment
Loss of Signal
Loss of Signal (electrical input)
Line Protection Switching
Line Termination Equipment
(OFLTE at BT premises)
Mediation Device
Multiframe (G.704)
Not Connected
NDM
NE
NET
NTE
Network
Network Termination Equipment
(OFLTE at the customer premises)
Operating Centre
Office Craft Terminal
Optical Distribution Frame
Optical Fibre Digital Line System
(Associated LTE, NTE and optical fibre
route)
Optical Fibre Digital Line Terminal
Equipment
Optical LOS (A-line)
Optical LOS (B-line)
Alcatel Rack Equipment Practice
OC
OCT
ODF
OFDLS
FC/PC
OFLTE
FP
FPGA
OPOL
Optical Connector
Fabry Perot
Field Programmable Gate Arraey
Optical Power out of Limit
OLOSA
OLOSB
S9
Page 0-13
OPOLA
OPOLB
ORX
OTX
PC
PCB
PDH
PFAL
PSU
RAB
RAI
RAM
SAB
T
TE
TMN
T interface
Terminal Equipment
Telecommunications Management
Network
Transparent transfer of 2 Mbit/s
Time Slot
TRA
TS
TS 0
Tx/Rx
UEQ
UL
WDM
X.21
Timeslot 0
Transmission direction defined by
optical output/input
Unequipped Tributary
Uplink (towards network)
Wavelength Division Multiplexing
Data traffic supported by X.21
interface on customer OFLTE
Page 0-14
Prepared by:
+47 22 63 88 10
+47 22 63 83 43
71385 stk n
Copyright2000
Alcatel Telecom Norway AS
Oslo, Norway
All rights reserved
Page 0-15