B.

Centring the condenser for Kohler illumination


After focusing the thin section, the field diaphragm is closed, the front lens of the condenser
inserted into the optical path, and the field diaphragm focused in the image plane by adjusting
the substage height (figure. 1.5-2 I-II). The following situations may be encountered:
a. The centr of the field diaphragm image coincides with crosshairs, i.e. the centre of the
field of view, indicating that the condensor is perfectly centired (figure. 1.5-2 III).
b. The field diaphragm image is offset with respect to the crosshair. In this case, The field
diaphragm image must be centred by turning the condensor-centring screw (figure. 1.5-2
II-III).
Finally, in order to avoid glare bye lateral stray light, the field diaphragm should be opened only
slightly beyond the margin of the field of view (figure. 1.5-2 IV).
C. Centring the light source
In modern microscopes, light source and collector are commonly integrated into the base of the
microscope and thus need not be centred. In certain microscope, centring bolts in the lamp case
allow to centre the lamp socket. After the condensor has been centred, the lamp position is
adjusted until the object field is evenly and brightly illuminated.
For precise kohler illumination, the collector must be adjusted so that an image of the lamp
filament is created in the plane of the aperture diaphragm of the condensor. This filament image
can be made visible by putting tracing paper onto the aperture diaphragm. A further image of the
filament is created in the upper focal plane of the objective which can be observed more
conveniently in conoscopic mode.
Filament image can only be observed if frosted glass inserts are removed from the illumination
path!
D. Adjustment of the oculars
If a microscope is fitted with a binocular head, the eyepiece must be adjusted individually in
order to obtain a focused image for both eyes, also after changing between different objectives.
Furthermore, the oculars must be adjusted for the correct interpupillary distance, i.e, the distance
between the eyes.
The oculars of infinity-corrected microscope are adjusted as follows (whereby the ocular with
the crosshairs should be placed in the right tube of the binocular):
1. Look through the ocular and close the left eye. The crosshairs in the right ocular is
observed with the right eye and focused with the diopter adjustment ring on this ocular.
Then the object image is focused by carefully adjusting the stage height with the fine
adjustment knob.
2. Now clos the right eye and observe the object image with the left eye through the left
ocular, without adjusting the stage vertically. If the image is not properly focused, the
adjustment must be made using the diopter adjustment ring on the left ocular. When
focusing the object image, it is important that both eyes are relaxed and focused to
infinity.

B. menyentringkan kondensor pada pencahayaan Kohler
Setelah memfokuskan sayatan tipis, bagian diafragma ditutup , lensa depan kondensor dimasukkan ke
dalam jalur optik, dan diafragma difokuskan pada bidang gambar dengan menyesuaikan tinggi substage
( gambar. 1,5-2 I- II ) . Situasi yang mungkin terlihat sebagai berikut:
a . Pusat gambar diafragma bertepatan dengan benang silang, yaitu pusat bidang pandang ,
menunjukkan bahwa kondensor yang memusat sempurna( figure. 1,5-2 III ) .
b . Bidang diafragma gambar diimbangi sehubungan dengan benang silang . Dalam hal ini , Bidang
diafragma gambar harus berpusat dengan memutar sekrup kondensor-sentring ( figure. 1,5-2 II - III ) .
Akhirnya , untuk menghindari silau oleh cahaya lateralis, diafragma harus dibuka hanya sedikit di luar
margin bidang pandang ( figure. 1,5-2 IV ).
C. Menyentringkan sumber cahaya
Pada mikroskop modern, sumber cahaya dan kolektor biasanya diintegrasikan ke dalam dasar mikroskop
dan dengan demikian tidak perlu terpusat . Dalam mikroskop tertentu , baut penyentringan dalam suatu
lampu memungkinkan dalam memusatkan lampu soket . Setelah kondensor telah terpusat , posisi
lampu disesuaikan sampai bidang objek secara merata dan cerah diterangi .
Dalam penerangan Kohler yang tepat, kolektor harus disesuaikan agar gambar dari lampu filament
dibuat dalam bidang bukaan diafragma kondensor tersebut . Gambar filamen ini dapat dibuat terlihat
dengan menempatkan kertas kalkir ke bukaan diafragma . Sebuah gambar lebih lanjut dari filamen
dibuat dalam bidang fokus atas tujuan yang dapat diamati lebih nyaman dalam mode konoskop.
Gambar filamen hanya bisa diamati jika sisipan kaca buram akan dihapus dari jalur iluminasi!
D. Penyesuaian lensa okuler
Jika mikroskop dilengkapi dengan kepala teropong , lensa mata harus disesuaikan secara individual
dalam rangka untuk mendapatkan gambar yang terfokus untuk kedua mata , juga setelah mengubah
antara tujuan yang berbeda. Selanjutnya, lensa okuler harus disesuaikan dengan jarak interpupillary
yang benar , yaitu , jarak antara mata. mikroskop okuler - dikoreksi disesuaikan sebagai berikut ( dimana
mata dengan garis bidik harus ditempatkan dalam tabung kanan teropong ):
1 . Lihatlah melalui mata dan menutup mata kiri . Garis bidik di mata kanan diamati dengan mata kanan
dan fokus dengan cincin penyesuaian diopter pada mata ini . Kemudian gambar objek difokuskan
dengan hati-hati menyesuaikan ketinggian panggung dengan tombol penyesuaian halus .
2 . Sekarang tutup mata kanan dan mengamati gambar objek dengan mata kiri melalui mata kiri, tanpa
menyesuaikan panggung secara vertikal . Jika gambar tidak terfokus dengan benar , penyesuaian harus
dibuat dengan menggunakan cincin penyesuaian diopter pada mata kiri. Ketika fokus objek gambar ,
penting bahwa kedua mata santai dan fokus hingga tak terbatas .