Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

Baldor

Large Frame AC
Induction Motors

Why Baldor?
For over 85
years, Baldor has
strived to provide
customers with
the best value
and reliability in
industrial electric
motors. That
dedication shows
in customer
preference for
Baldor motors.
To be considered
as the most
preferred...

Customer
Preference

90%

94%

50%
20%

1985 1990 2000 2003


Percentage of research studies in which
Baldor was chosen most preferred.

Baldor offers the industrys broadest line of stock


products. Save valuable time with just one call to
Baldor. We offer more than 7,000 stock motors, drives,
generators and gearboxes.
Energy-efficiency leader. We began lowering the
energy consumption of our motors in the 1920s, long
before others were even talking about it. Today, our
expansive line of Super-E premium-efficient motors
ranges from 1 through 1250 hp. Baldors Super-E line
offers customers the highest overall efficiency levels
in the industry.
Baldor products are
available at more locations
than any other brand.
Our 35 district offices
across North America offer
immediate availability of
Baldor products to thousands
of distributors.
Continuous innovation to improve reliability.
Baldor leads the motor industry in applying new
technologies and materials to improve motor reliability.
Baldor was the first to introduce ISR (Inverter Spike
Resistant) magnet wire, which is up to 100 times
more resistant to voltage spikes. Baldor was first to
use Exxons new Polyrex EM grease, which protects
motor bearings better, providing improved lubrication
life, greater shear stability, and superior resistance to
washout, rust and corrosion.

Industrys
shortest lead
times/Flexible
manufacturing.
Baldor has the
industrys shortest
lead times on
custom motors
just ten working
days. Our unique
FLEX FLOW
manufacturing process lets us produce any order in any
quantity, quickly and efficiently.
Industrys best information. Only Baldor offers
customers so many choices for product information
with a wide variety of catalogs and product brochures, a
CD-ROM electronic catalog, the Baldor Web site (www.
baldor.com), or you may talk to a Baldor customer
service person at one of our sales offices.

Table of Contents

Page
Specifications and Features
Design Features 3
ISR Wire / POLYREXEM Grease 5
Energy Savings 6
Design Characteristics 7
Open Drip Proof - WPI, WPII 9
IEC Metric Frame 10
Totally Enclosed Fan Cooled 11
Inverter/Vector - Totally Enclosed Blower Cooled 13
Matched Performance Curve 14
Explosion-Proof 14
Custom Motor Options 18
Motor Performance Data
Totally Enclosed Fan Cooled
Totally Enclosed Blower Cooled
Open Drip Proof
Explosion Proof

15
17
17
17

Motor Dimensions 19-23


Connection Diagrams
Sample Test Data Report

www.baldor.com

24-25

26

The Best Value


in Large Motors, too.
Years ago, when Baldor began making large frame AC
motors and drives, we spent a lot of time in the field.
We talked in depth with plant maintenance and design
engineers. We asked about tough environments such
as mining, pulp and paper manufacturing, and chemical
processing. We took the opportunity to learn in great
detail what capabilities and characteristics people like
and need. And most important, we learned what not to
do.
One of the frequent suggestions was the need for better
structural integrity and rigidity. And many wanted motors that were tough enough to withstand the rigors of
even the most extreme applications.
Today, Baldor makes tough, reliable motors up to 1,250
HP for a wide variety of applications. And we continue
to listen and follow through on what customers want.
Thats why you can count on Baldor for superior value.
Baldor large frame motors and drives feature:
Choice of all popular enclosures,
voltages and frequency, custom orders
are no problem.
Super-E

Premium

Choice of Baldor
NEMA
efficiency or high efficiency designs.

Extra heavy-duty cast iron frames,
endplates and stiff foot structures, to
minimize potential vibration problems.

A Baldor 400 Hp, 449T Open Drip Proof Motor located in the
Dallas water pumping station.

Electrical grade steel laminations, to


minimize eddy currents and hysteresis
losses, results in cooler operation and
more efficiency.
Upgraded low-loss electrical grade core plates,
to reduce core losses for the life of the motor
(others offer as low as C-3, standard).
Ability to meet many industry standard
specifications such as IEEE 841or
company-specific specs.

Premium rotor system design, to operate


below the 1st critical design speed by at
least a 15% safety margin can be
operated from a adjustable speed control
through entire speed range.

There are many other advantages to specifying


Baldor large frame motors or drives. Youll find
them on the following pages as well as all the specs
you need to make the perfect decision
for your application.

Choice of standard high-pressure


die-cast aluminum rotors or fabricated
copper bar rotors.

Take a look. Talk to your Baldor distributor. If you dont


see what you need, ask us about custom capabilities.
You can likely have it on your floor in three weeks or
less.

Precision dynamic balanced with state-of the-art equipment, to ensure finished


motors meet NEMA vibration standards.
Class H-rated vacuum pressure
impregnated (VPI) insulation systems
with surge rings on all end turns to
minimize risk of premature failure.

www.baldor.com

Large Frame AC Motors: Built for Reliable Performance


Class F (or better) insulation system allows
winding to withstand higher temperatures resulting
in longer life. Medium voltage motors feature
formed copper coils with glass mica-wrapped
magnet wire, further insulated with Nomex tape.
Baldor ISR (Inverter Spike Resistant)copper
magnet wire on low voltage motors (<600V).

Two-part epoxy primer


inside and out; two-part
epoxy finish paint on
severe duty motors.
Fan and fan cover designed
for maximum cooling and
quieter operation.

Stator and rotors utilize premium


core plate providing low core
losses for the life of the motor.

Standard surge
ropes on end
turns.

Regreasing provisions with


reliefs for easy bearing maintenance.
Dual mounting foot holes, especially
convenient when mounting a motor
for replacement duty.
Rugged cast iron frames, endplates
and conduit boxes for greater
strength and stiffness, resulting in
lower vibration and longer life.

Standard vacuum
pressure impregnation
(VPI) using 100% epoxy
solids for long life and
greater protection.

Diagonally split oversized cast iron conduit box


exceeding NEC standards makes connections
easier. Rotatable in 90 increments and is easily
converted from F-1 to F-2 mounting. Provision
for grounding in conduit box and on the ODE
mounting foot.

www.baldor.com

Auxiliary conduit box on medium


voltage ratings for winding RTDs
and space heaters.

High-pressure die cast aluminum


rotor through 449T frame; fabricated
copper bar rotor on larger sizes
for increased efficiency. Precision
balanced for smooth operation and
longer bearing life.

Locked bearing construction


reduces endplay. Convertible to
roller bearing for belted loads.
Optional sleeve bearings available.

Operates below the first critical speed by at least


a 15% margin - allows operation throughout entire
speed range with adjustable speed control.
High strength shaft steel.

Generalized Ranges
Enclosure

FRAME SIZES

Ref. Page

449T

5000

5800

TEFC

250-400 HP

400-600 HP

400-800 HP

ODP

200-450 HP

500-800 HP

500-1250 HP

WPI

500-800 HP

500-1250 HP

WPII

500-800 HP

500-1250 HP

400-600 HP

400-800 HP

10

Inverter/ Vector

250-350 HP

Explosion Proof

250-300 HP

11

Typical 4-Pole HP ranges.

www.baldor.com

Going Beyond the Industry Standard


in Severe Duty Motors
Baldors Severe Duty motors are another example of our commitment to provide reliable
performance, while exceeding customer expectations.

Wound with ISR (Inverter Spike Resistant) Magnet Wire

Motors wound with ISR wire are up to


100 times more resistant to transient
voltage spikes, high frequencies
and short rise time pulse frequently
produced by inverters and vector
drives. The result is a better motor
with longer life, reduced downtime
and better overall value.

ISR Wire is Superior in Pulse Endurance Test


1000

Technical Specifications:
NEMA MW-35
Pulse Endurance
Test Conditions:
Twisted pairs @ 20,000 Hz,
2 kV, 0.025 microsecond
risetime, 50% duty cycle, 90C

100

Index

Recognized as Product of the Year


by Plant Engineering magazine in
1996, Baldors ISR wire is a standard
feature in Baldor AC motors, 575 volt
and under, 1 hp and up.

Pulse Endurance Index =


Life of Product/Life of 18 H
MW-35 (Reference)

10

Thermal Properties, Chemical


Resistance and Dielectric
Strength:
ISR Wire is equal to or better
than MR wire.

Thermal Rating: 200C


Source:
Phelps Dodge Magnet Wire
Company (Used with permission)

0.1
Moisture Resistant
MR Wire

Triple Build
Wire

ISR Wir e

Technical Specifications: NEMA MW-35


Pulse Endurance Test Conditions: Twisted pairs @ 20,000 Hz,
2 kV, 0.025 microsecond risetime, 50% duty cycle, 90C
ulse Endurance Index = Life of Product/Life of 18 H MW-35 (Reference)
Thermal Properties, Chemical Resistance and Dielectric Strength:
ISR Wire is equal to or better than MR wire.
Thermal Rating: 200C
Source: Phelps Dodge Magnet Wire Company (Used with permission)

Standard on All Baldor Motors: Exxon Polyrex EM Polyurea Grease


Its a fact: Bearing failure is the #1 mechanical reason for motor failure. So the better the grease
protecting those bearings, the better and longer the motor performs.
Today, that better grease is Exxons new Polyrex EM polyurea grease now standard on all
Baldor motors. It provides lubrication life of more than four times greater than other polyurea
greases in tests up to 350F. It exhibits greater durability when subjected to mechanical shearing
forces. Furthermore, a specially formulated additive in the grease resists washout, rust and
corrosion even when subjected to salt water conditions.

Outstanding High-Temperature
Lubrication Life

430
415
400
385
370
355
340
325
310
295
280
265

Penetration after
60 strokes
Penetration after
100,000 strokes

Polyrex EM

Competitive
Polyurea Grease

Typical Lithium
Complex Grease

ASTM D 3336 Grease Life at


350F (hours)

ASSTM D 217
Cone Penetration (mm/10)

Excellent Shear Stability

800
700
600
500
400
300
200
100
0

As illustrated here, the proprietary polyurea thickener system in


Polyrex EM exhibits excellent durability and stability when subjected to
a mechanical shearing force. Mechanical shear stability is a measurement
of the greases thickener system. Good mechanical shear stability is
important in roller bearing applications where excessive grease softening
may lead to grease leakage or purging from the bearing.
Source: Exxon Mobil Product Data Sheet DG-3C, 6/15/99.

www.baldor.com

Polyrex EM

Competitive
Polyurea
Grease

Typical
Synthetic
Lithium Complex
Grease

Typical
Lithium
Complex
Grease

In the severe ASTM D 3336 High-Temperature Grease Life Test,


Polyrex EM dramatically out performed a competitive polyurea
grease and conventional lithium-complex greases.
Source: Exxon Mobil Product Data Sheet DG-3C, 6/15/99.

Making Energy Efficiency Work For You


Why is Energy Efficiency Important?
Electric motor-driven systems used in industrial processes consumed 679 billion kWh, or 63% of all electricity used in U.S. industrial
sector, according to a U.S. Department of Energy report published in 1998. The report goes on to reveal that industrial motor energy
could be reduced by up to 18 percent if companies were to apply motor and motor system efficiency upgrades, including the use of
adjustable speed drives. The potential positive impacts on companies bottom lines and the environment are significant.

Purchase Price is Only


a Small Piece of the Pie

Initial
Purchase 2%
One
Rewind 0.7%

The pie chart to the right shows the typical life cycle cost of a 100 hp
motor operating in continuous duty over a 20-year life. As you can see,

Energy
97.3%

the original purchase price is almost insignificant compared to what it


will cost to power the motor during its useful life.

How Baldor Super-E


Efficiencies Compare to
Industry Standards
Baldors line of Super-E motors offers customers the

Electric Motor Efficiency Ratings


100%

Baldor
Super-E

highest level of overall efficiencies available from any


motor manufacturer, complying with NEMA Premium

EPAct
efficiencies

efficiency.

BE$T Baldor Energy Savings


Tool Makes Calculating
Payback Easy

Average
efficiency of
motors in use

85

In order to make payback calculations easier for


customers, Baldor developed BE$T (Baldor Energy

70

Savings Tool). BE$T helps calculate energy cost

1 1.5 2

Horsepower

and energy savings for motors, as well as payback


timeframes. A popular feature of BE$T is that it

What is Higher Efficiency Worth?

allows users to make head-to-head comparisons of

$1500

analysis.
BE$T Baldor Energy Savings Tool is available as a
download through Baldors award-winning Web site
(www.baldor.com/support/index.asp,) as well
as a stand-alone CD-Rom available from the
Baldor Literature Hotline (1-800-828-4920).

Dollar Savings Per Year

up to three motors, giving customers the information


to make an informed decision through comparative

10 15 20 25 30 40 50 60 75 100 125 200

168
Hour Week
Continuous

1200

80 Hour
Week
2 Shifts

900

40 Hour
Week
1 Shift

600

Savings based on
a 40 hp, Baldor
Super-E 94.5%
compared with the
average efficiency
of motors in use.
(50 weeks/year)

300
0

.05

.06

.07

.08

.09

.10

Power Cost Per kWH

www.baldor.com

Electrical Design Characteristics


Specification
Voltage

Low
Voltage

Description
460 or 575 volts, random-wound

950 volts, random-wound

2300, 3300, 4160 or 2300/4160 volts, formed-coil

460, 950 or 6600 volts, formed-coil

Frequency

60 Hz standard, 50 Hz optional

Service Factor

1.15 standard

Ratings

NEMA Design B

NEMA Design C (contact Baldor for frame size)

NEMA Design D (contact Baldor for frame size), 1.0 S.F.

Crusher Duty (high pull-out, pull-up and locked rotor torques)

Duty Cycle
Ambient Temperature

Continuous Duty

Special Duty Cycles

40oC ambient temperature

Higher or lower ambient temperatures

Temperature Rise

Class B rise (80oC) at 1.0 service factor, Class F rise at 1.15SF

Laminations

Low-loss electrical grade steel

Windings

Class H+ (200oC) ISR (Inverter Spike

Resistant)

copper magnet wire

Class H+ (200oC) Copper form-wound coils wound with mica


tape and VPI epoxy impregnated
Insulation Class

Class F, Non-hygroscopic epoxy VPI

Class H, Non-hygroscopic epoxy VPI

End Turn Bracing

Surge rings laced to end-turns and VPI epoxy impregnated


for structural integrity

Stator Insulation

Nomex Class H slot liner

Woven Class H glass phase insulation

Epoxy impregnated blocking felt between coils

Lead Material

Non-wicking cross-linked polyethylene material

Thermal Protection

Thermostats

RTDs with separate conduit box 100 platinum standard,


10 copper or 120 nickel optional; (RTDs standard in stock
TEFC and ODP motors 300 Hp and up)

Thermistors

(Strip space heaters standard in stock TEFC motors 300 Hp and up)

1024 PPR Electrically isolated BEI optical encoder standard on


Baldor Vector Drive motors (other PPR available)

NorthStar (LakeShore) or Avtron pulse generators available

Resolvers available

Standard test supplied with motor (Balance test, winding resistance,


no-load, full load, amps and speed, power factor, torque
and hi-pot test per NEMA MG-1)

Heat run and complete efficiency testing at temperature

Either of above tests as witnessed

CSA recognized components through 449T (File LR2262)


5000 and 5800 TEFC frame through 600 HP and up to 600 volts;
500 HP and up to 4160 volts (File LR36841)

Space Heaters
Feedback Devices

Testing

Approvals

120 volt standard, other voltages optional

S = Standard O = Optional

Medium
Voltage

www.baldor.com

Mechanical Design Characteristics


Specification
Frame Dimensions
Construction
Multiple Mounting
Holes in Base
Face mounting
Nameplate
Conduit Box

Slinger & Seals


Drains
Hardware
Ground Lug
Lifting Provisions
Enclosure
Cooling Fan
Rotor Construction
Balance
Shaft Material

Paint

Bearings

Lubrication

Grease Provisions
Engineering
Specifications
Limited Warranty

Description
NEMA
IEC Metric
Complete cast iron frame, endplates, conduit box and fan cover
(5800 frame has steel fan cover)
Multiple mounting holes standard.
Dowel pin holes standard on all 5000 and 5800 frames.
C-face, D-flange, P-base available
Custom mounting configurations available
Stainless steel, Complete operating data in accordance
with NEMA MG-1. Bearing identification numbers included
Oversized cast iron, diagonally split box, rotatable in 90o increments.
Gasketed lid and gaskets between frame and box. NPT threaded
opening. F-1 orientation standard, convertible to F-2 (top-mount
conversion available on 5800 frame)
Extra-large oversized conduit boxes available
Forsheda V-type neoprene slinger each (Chemical Process motors only)
Inpro seal on shaft
One-way drain and breather located at lowest point of motor when
mounted in a horizontal position
Grade 5, U.S. Standard, zinc dichromate or cadmium-plated steel
Stainless steel hardware
Located in conduit box. Silicon-bronze stud-type.
Integrally-cast lifting lugs motor can be lifted with any enclosure in tact
TEFC, Open Drip-proof, WPI, WPII, TEBC, TEWAAC
TEFC & TEBC Non-sparking
Non-sparking metal
High pressure die-cast aluminum (through 449)
Fabricated copper bar construction (5000 up)
Dynamically balanced better than NEMA MG1 specs
1045 high strength steel (through 5000 frame)
4140 high strength steel (5800 frame - up)
Other high strength alloys or forged shafts
Grey lacquer over primer coat
Two-part epoxy system with 4-6 mils build (Chemical Process motors)
Customer specified paint
Premium grade vacuum-degassed ball bearings
Roller bearing on drive end
Renk sleeve bearings (5000-up)
Electrically isolated bearings
Bearing temperature RTDs
Vibration monitors
Exxon Ployrex EM grease (or equivalent)
Oil lube for sleeve bearings
Customer specified grease
Oil mist lubrication
NPT fittings installed in endplate with pressure relief fittings on drain lines
Oil sight gauges for sleeve bearings
IEEE 841- 2001
Customer specific requirements
3 years on Super-E, 24 months on Standard-E,
18 months most other motors

S
O

Medium
Voltage
S
O

O
O

O
O

O
S
O

O
S
O

S
O
S
S

S
O
S
S

S
O
S
S
S
S
S
O
S
S
O
S
O
O
O
O
O
S
S
O
O
S
S
O
O

S
O
S
S
S
S
S
O
S
S
O
S
O
O
O
O
O
S
S
O
O
S
S
O
O

Low Voltage

S = Standard O = Optional

www.baldor.com

Open Drip Proof and


WPI WPII
Baldor Electric offers a rugged cast iron industrial motor in your
choice of open enclosures. Standard motor designs
are high efficiency, but our Super-E with NEMA Premium
efficiency is also available.
460, 575, 950, 2300, 3300, 4160 or 6600 volts 60 Hz
380, 400, 415, 950, 2300, 4160 or 6000 volts 50 Hz
High efficiency or Super-E NEMA Premium efficiency
Class B rise with Class F insulation
Baldor ISR (Inverter Spike Resistant) magnet wire on designs
below 600 volts

ODP High Efficiency 460 or 575 volts, 60 Hz, 1.15 SF


HP

kW

200
250
300
350
400
450
500
600
700
800
900
1000
1250

150
187
224
261
298
336
373
448
522
600
671
746
933

RPM
3600
444TS
445TS
445TS
445TS
449TS
449TS/5009S
5009S
5009S
5009S
5808S
5808S
5808S

1800
445T
445T
445T
445T
449T
449T
5009L
5009L
5011L
5011L
5808
5810
5810

1200
445T
449T
449T
5009L
5009L
5009L
5011L
5011L
5808
5810
5812

444TS, 445TS, 445T motors do not have standard VPI.

900
5007L
5009L
5009L
5009L
5011L
5011L
5808
5810
5810

5000 & 5800 frame motors can be ODP or WPI.

ODP WPI High Efficiency 2300 or 4160 volts, 60 Hz, 1.15 SF


HP

kW

150
200
250
300
350
400
450
500
600
700
800
900
1000
1250

112
150
187
224
261
298
336
373
448
522
600
671
746
933

RPM
3600
449TS
449TS
449TS
449TS
5009S
5009S
5009S
5009S
5009S
5009S
5808S
5808S

1800
449T
449T
449T
449T/5009L
5009L
5009L
5009L
5009L
5011L
5011L
5808
5810
5810
5810

Data subject to change without notice.

1200
449T
5009L
5009L
5009L
5009L
5011L
5011L
5011L
5808
5810
5812

900
5009L
5009L
5009L
5011L
5011L
5808
5808
5810
5810
5812

5000 & 5800 frame motors can be ODP or WPI.


Contact a Baldor office for latest capabilities.

www.baldor.com

IEC Metric Frames Available


In addition to the NEMA frames show here, Baldor motors
are available with IEC metric mounting dimensions in
frames through 450. Contact Baldor for dimensions and
layout drawings.

ODP/WPI High Efficiency 6600 volts, 60 Hz, 1.15 SF


HP

kW

350
400
450
500
600
700

261
298
336
373
448
522

RPM
3600
5808S
5808S
5808S
5808S
5808S
5808S

1800
5009L
5009L
5009L
5009L
5011L
5808

1200
5009L
5009L
5011L
5808
5810

900
5011L
5808
5810
5810

1200
5009L
5009L
5009L
5011L
5011L
5011L
5808
5810
5812

900
5009L
5009L
5011L
5011L/5808
5808
5810
5810

WPII High Efficiency 460 or 575 volts, 60 Hz, 1.15 SF


HP

kW

300
350
400
450
500
600
700
800
900
1000
1250

224
261
298
336
373
448
522
600
671
746
933

RPM
3600
5009S
5009S
5009S
5009S
5009S
5009S
5009S*/5808S
5808S
5808S

1800
5009L
5009L
5009L
5009L
5009L
5011L
5011L
5011L
5810
5810
5810

WPII High Efficiency 2300 or 4160 volts, 60 Hz, 1.15 SF


HP

kW

300
350
400
450
500
600
700
800
900
1000
1250

224
261
298
336
373
448
522
600
671
746
933

RPM
3600
5009S
5009S
5009S
5009S
5009S
5009S
5009S/5808S
5009S*/5808S
5808S

1800
5009L
5009L
5009L
5009L
5009L
5011L
5011L
5808
5810
5810
5810

Data subject to change without notice.

1200
5009L
5009L
5011L
5011L
5011L
5808
5810
5810
5812

900
5009L
5009L
5808
5808
5810
5812

Contact a Baldor office for latest capabilities.

www.baldor.com

10

TEFC Totally Enclosed


Fan Cooled

Baldor Electric offers the ultimate rugged


cast iron industrial motor for your most severe
process applications. Motor designs are
Super-E premium efficiency, but high
efficiency is also available.
460, 575, 950, 2300, 3300, 4160 or
6600 volts 60 Hz
380, 400, 415, 950, 2300, 4160 or
6000 volts 50 Hz
Super-E premium or high efficiency
Class B rise with Class F insulation
Baldor ISR (Inverter Spike Resistant)
magnet wire on designs below 600 volts

TEFC Super-E NEMA Premium Efficiency


460 or 575 Volts, 60 Hz, 1.15 SF
HP

kW

200

RPM
3600

1800

1200

900

150

447TS

447T

449T

5007L

250

187

449TS

449T

449TY

5009L/5810

300

224

449TS

449TY/449TSY

449TY

5011LY/5810

350

261

449TS

449TY/449TSY

5009L/5810

5011LY/5810

5011LY/5810

5810

400

298

449TS

449TY/449TSY
5007L/5810

450

336

5007SY

5007L/5810

5011LY/5810

5810

500

373

5009SY

5009L/5810

5011LY/5810

5812

600

448

5009SY

5011LY/5810

5810

5812

700

522

5810

5810

800

600

5810

900

671

5812

Sleeve bearings required.


Data subject to change without notice.

11

Contact a Baldor office for latest capabilities.

www.baldor.com

TEFC Super-E NEMA Premium Efficiency


2300 or 4160 Volts, 60 Hz, 1.15 SF

RPM

HP

kW

100

74.6

125

93.2

449T

150

112

447TS

449T

449T

5007L

200

150

449TS

449T

449T/5007L

5009L

250

187

449TS/5007SY

449T/5007L

5007L/5009L

5011LY/5810

300

224

5007SY

449TY/5007L/5011LY

5009L/5011LY/5810

5011LY/5810

350

261

5007SY

5007L/5011LY

5009L/5011LY/5810

5810

400

298

5007SY

5007L/5011LY/5810

5011LY/5810

5810

450

336

5007SY

5007L/5011LY/5810

5011LY/5810

5810

500

373

5009SY

5009L/5011LY/5810

5011LY/5810

5812

600

448

5011LY/5810

5810

700

522

5810

5812

800

600

5812

3600

1800

1200

900

449T

TEFC Super-E NEMA Premium Efficiency


6600 Volts, 60 Hz, 1.15 SF

RPM

HP

kW

3600

1800

1200

900

150

112

5007SY

5007L

5007L

5009L

200

150

5007SY

5007L

5007L

5011LY

250

187

5007SY

5007L

5009L

5011LY

300

224

5009SY

5007L

5011LY

5810

350

261

5009SY

5007L

5011LY

5810

400

298

5009SY

5009L

5011LY

5810

450

336

5009SY

5011LY

5810

500

373

5011LY

5810

600

448

5810

Sleeve bearings required.


Data subject to change without notice.

Contact a Baldor office for latest capabilities.

www.baldor.com

12

Inverter / Vector Duty TEBC Totally Enclosed Blower Cooled

Baldor Electric offers the ultimate rugged cast iron industrial motor
for your adjustable speed, constant torque applications. Motors are Super-E
NEMA Premium efficiency.
460 or 575 or 6600 volts 60 Hz
380, 400 or 415, or 6000 volts 50 Hz
Super-E NEMA Premium efficiency
Able to start across line without drive
Class F rise with Class H insulation
Baldor ISR (Inverter Spike Resistant)
magnet wire on designs below 600 volts
Separately powered heavy duty axial
cooling fan
Electrically isolated BEI optical encoder
on vector drive motors optional Avtron or
NorthStar pulse generators
Shaft grounding assembly
Option formed coil winding on 460 or 575 V.

Inverter/Vector 460 or 575 Volts, 60 Hz, 1.0 SF


RPM

HP

kW

3600

1800

1200

900

200

150

447TS

447T

449T

5007L

250

187

449TS

449T

449T

5009L/5810

300

224

449TS

449T

449T

5011LY/5810

350

261

449TS

449T

5009L/5810

5011LY/5810

400

298

449TS

5007L/5810

5011LY/5810

5810

450

336

5007S

5007L/5810

5011LY/5810

5810

500

373

5009S

5009L/5810

5011LY/5810

5810

600

448

5009S

5011LY/5810

5810

700

522

5810

5810

800

600

5810

Sleeve bearings required.


Data subject to change without notice.

13

Contact a Baldor office for latest capabilities.

www.baldor.com

Matched Performance Curves


450.00

PEAK TORQUE

1200.0

400.00

1050.0

350.00

900.0

300.00

750.0

250.00

AMPS

600.0

200.00

TORQUE

HORSEPOWER

450.0

150.00
100.00

300.0
CONTINUOUS
OPERATING AREA

150.0
0.0

300

600

900

1200

1500

HORSEPOWER AMPS

These performance curves show the


continuous operating constant torque speed
range that can be produced without exceeding
Class F temperature rise in the motor. Peak
torque is the maximum amount of torque a
Baldor inverter or vector drive can produce.
This may be limited by either the motors
breakdown torque or the current from
the control.

1350.0

TORQUE (ft-lbs)

Matched Performance is Baldors


solution to the concern, What kind of constant
horsepower speed range will I get with this
combination of motor and control? Each
test is performed in Baldors own
engineering laboratory.

50.00
1800

0.00

2100

SPEED (rpm)

Explosion Proof Motors


Baldor Electric offers the ultimate rugged cast
iron industrial motor for applications where
hazardous fumes or dust may be present.
460, or 575 60 Hz
380, 400, or 415 volts 50 Hz
Super-E NEMA Premium efficiency or high efficiency
Class B rise with Class F insulation
Baldor ISR (Inverter Spike Resistant) magnet wire
UL and CSA approved for hazardous locations
Includes UL approved conduit box

Explosion Proof Motors 460 or 575 volts, 60 Hz, 1.0 SF


HP

kW

150
200

RPM
3600

1800

1200

900

112

445TS

445T

449T

449T

150

449TS

449T

449T

250

187

449TS

449T

449T

300

224

449TS

449T

Class I, Group C & D; Class II, Groups F and G, T3C


Data subject to change without notice.

Contact a Baldor office for latest capabilities.

www.baldor.com

14

Performance Data
TEFC NEMA Premium Efficiency 460 Volts, 3 Phase, 60 Hz, 1.15 SF
AMPS @ 460V

HP

200

250

300

350

400

450

500

600

700
800

kW

149

187

224

261

298

336

373

448

522
600

RATED
TORQUE
FULL LOCKED LB. FT.
LOAD ROTOR

RPM FRAME

CATALOG #

3570

447TS

ECP4416T-4

214

1720

1780

447TS

ECP4407T-4

225

1530

1180

449T

ECP44206T-4

242

890

5007L

Custom

238

3545

449TS

ECP44252T-4

1780

449T

ECP4408T-4

1180

449TY

EFFICIENCY %

FULL
1/2
LOAD

3/4

BEARINGS

FULL
D.E. O.D.E.
LOAD

1/2

3/4

294

94.4

95.2

95.4

87

91

92

6314

6314

589

95.0

96.0

96.2

82

86

87

6319

6314

1647

890

94.5

95.2

95.8

70

80

81

6319

6314

1342

1180

93.7

94.4

95.0

76

81

82

6324

6222

272

2162

370

95.4

95.8

95.8

81

87

90

6314

6314

281

1910

740

95.2

95.8

96.2

82

85

87

6319

6314

ECP44256T-4

294

1690

1105

95.0

95.6

95.8

73

80

83

6319

6314

890

5009L

Custom

298

1775

1475

94.6

95.2

95.4

72

79

82

6324

6222

3545

449TS

ECP44302T-4

320

2546

444

95.3

95.5

95.8

86

90

91

6314

6314

1785

449TY

ECP44304T-4

337

2290

883

95.2

96.0

96.2

81

86

87

6319

6314

1185

449TY

ECP44306T-4

355

2370

1328

94.3

95.0

95.0

71

80

83

6319

6314

1185

5007L

Custom

344

2592

1765

95.2

95.6

95.8

80

84

86

6322

6222

3545

449TS

ECP44352T-4

344

2930

518

95.3

96.0

96.2

88

91

92

6314

6314

1785

449TY

ECP44354T-4

393

2670

1032

95.0

95.8

95.8

81

86

87

6319

6314

1185

5009L

Custom

400

1880

1551

95.5

95.8

95.8

79

82

84

6322

6222

895

5810

Custom

422

2574

2054

94.0

94.5

94.5

68

77

81

3545

449TS

ECP44402T-4

422

3155

592

95.4

95.8

95.8

89

92

93

6314

6314

1780

449TY

ECP44404T-4

454

3151

1179

95.6

95.8

96.2

78

82

87

6319

6314

1190

5011L

Custom

446

3025

1765

95.9

96.3

96.0

82

87

88

6322

6222

890

5810

Custom

2358

3570

5009S

Custom

482

2917

660

95.8

96.2

96.2

86

90

91

6314

6314

1790 50011LY

Custom

498

3315

1320

95.4

95.8

96.2

80

84

88

6322

6222

1185

5011L

Custom

486

3757

1995

94.9

95.7

95.8

78

86

87

6322

6222

890

5810

Custom

2654

3575

5009S

Custom

530

3389

735

96.2

96.4

96.2

89

92

92

6314

6314

1785

5011L

Custom

540

3487

1465

95.6

96.1

96.5

84

88

90

6322

6222

1185

5011L

Custom

552

3822

2216

96.0

96.2

96.2

82

87

89

6322

6222

890

5810*

Custom

2950

6324

6322

3575

5009S

Custom

636

4464

881

95.8

96.0

96.2

89

91

92

6314

6314

1790

5011L

Custom

638

3803

1758

96.2

96.8

97.0

88

91

91

6322

6222

1185

5810

Custom

2658

6324

6322

3585

5009S

Custom

1025

6314

6314

1785

5810

Custom

2058

6322

6322

1185

5810*

Custom

3101

6324

6322

1785

5810*

Custom

2353

6324

6322

*1.0 SF
If data is not shown, contact a Baldor office.
Data subject to change without notice.

15

POWER FACTOR
%

Contact a Baldor office for latest capabilities.

www.baldor.com

Performance Data
TEFC NEMA Premium Efficiency 460 Volts, 60 Hz, 1.15 SF with Roller Bearings
AMPS @ 460V

HP

kW

RPM FRAME

150

112

1180

447TY

ECP44156TR-4

178

1154

667

95.2

95.8

95.8

49

79

82

NU319

6314

200

149

1780

447TY

ECP4407TR-4

225

1530

589

95.0

96.0

96.2

82

86

87

NU319

6314

1180

449TY

ECP44206TR-4

242

1647

890

94.5

95.2

95.8

70

80

81

NU319

6314

250

187

1780

449TY

ECP4408TR-4

281

1910

740

95.0

96.0

96.2

81

86

87

NU319

6314

1180

449TY

ECP44256TR-4

294

1690

1105

95.0

95.6

95.8

73

80

83

NU319

6314

1785

449TY

ECP44304TR-4

337

2290

883

95.2

96.0

96.2

81

86

87

NU319

6314

1185

449TY

Custom

355

2370

1328

94.3

95.0

95.0

71

80

83

NU319

6314

1185

5007L

Custom

344

2592

95.2

95.6

95.8

80

84

86

300

224

CATALOG #

RATED EFFICIENCY % POWER FACTOR % BEARINGS


TORQUE
FULL LOCKED
FULL
FULL
1/2 3/4
1/2 3/4
D.E. O.D.E.
LOAD ROTOR LB. FT.
LOAD
LOAD

350

261

1785

449TY

ECP44354TR-4

393

2670

1032

95.0

95.8

96.2

81

86

87

NU319

6314

400

298

1780

449TY

ECP44404TR-4

449

3050

1179

95.2

96.0

96.2

81

86

87

NU319

6314

TEFC High Efficiency 460 Volts, 3 Phase, 60 Hz, 1.15 SF


AMPS @ 460V

CATALOG #

RATED EFFICIENCY % POWER FACTOR %


TORQUE
FULL LOCKED
FULL
FULL
1/2 3/4
1/2 3/4
LOAD ROTOR LB. FT.
LOAD
LOAD

HP

kW

RPM FRAME

200

149

1180

449T

M44206T-4

236

1337

885

94.8 95.3

95.0

64

76

300

224

1785

449T

M44304T-4

328

2566

883

95.8 96.0

95.8

81

350

261

1785

449T

M44354T-4

388

2871

1032

94.5 95.7

95.8

400

298

1785

449T

Custom

440

3134

1180

95.8 96.1

95.8

If data is not shown, contact a Baldor office.


Data subject to change without notice.

BEARINGS
D.E.

O.D.E.

81

6314

6319

86

88

6314

6319

81

88

89

6314

6319

82

88

89

6314

6319

Contact a Baldor office for latest capabilities.

www.baldor.com

16

Performance Data
TEFC NEMA Premium Efficiency 575 Volts, 60 Hz, 1.15 SF
HP

200

250

300

350

400

450

500

600

700
800

kW

149

187

224

261

298

336

373

448

522
600

RPM

AMPS @ 575V RATED


FULL LOCKED TORQUE
FRAME CATALOG #
LOAD ROTOR LB. FT.

EFFICIENCY %
1/2

3/4

FULL
LOAD

1/2

BEARINGS

3/4

FULL
LOAD

D.E.

O.D.E.

3570

447TS

174

294

94.8

95.4

95.8

83

87

89

6314

6314

1780

447T

ECP4407T-5

179

1602

589

95.2

95.8

96.2

80

84

87

6319

6314

1180

449T

Custom

194

1341

890

94.4

95.1

95.8

75

78

81

6319

6314

890

5007L

Custom

196

1175

1180

94.6

95.2

95.0

70

78

81

6324

6222

3545

449TS

Custom

370

6314

6314

1780

449T

Custom

249

1986

740

95.0

95.6

96.2

81

83

86

6319

6314

1180

449TY

Custom

235

1105

95.8

83

6319

6314

890

5009L

Custom

242

1390

1475

94.1

94.8

95.4

79

81

82

6324

6222

3545

449TS

Custom

444

6314

6314

1785

449TY

Custom

319

2366

833

95.0

95.8

96.2

80

84

87

6319

6314

1185

449TY

Custom

1328

6319

6314

890

5011L

Custom

290

1716

1765

94.8

95.2

95.4

77

80

82

6322

6222

3545

449TS

Custom

518

6314

6314

1785

449TY

Custom

389

2773

1032

95.2

95.9

96.2

82

83

86

6319

6314

1185

5009L

Custom

308

2204

1551

95.1

95.5

95.8

83

87

88

6322

6222

895

5810

Custom

2054

3545

449TS

Custom

592

6314

6314

1780

449TY

Custom

460

3162

1179

95.0

95.8

96.2

81

84

86

6319

6314

1190

5011L

Custom

1765

6322

6222

890

5810

Custom

2358

6324

6322

3570

5009S

Custom

660

6314

6314

1790

5009L

Custom

1320

6322

6222

1185

5011L

Custom

1995

6322

6222

890

5810

Custom

2654

6324

6322

3575

5009S

Custom

422

2622

735

95.5

96.0

96.2

88

91

92

6314

6314

1785

5011L

Custom

1465

6322

6222

1185

5011L

Custom

438

3026

2216

96.2

96.4

96.2

82

87.5

89

6322

6222

890

5810*

Custom

2930

6324

6322

3575

5009S

Custom

881

6314

6314

1790

5011L

Custom

510

3760

1758

96.0

96.2

96.2

91.5

92.7

93.1

6322

6222

1185

5810

Custom

532

3380

2641

95.8

96.1

96.2

80

83

87

6324

6322

3585

5009S

Custom

1025

6314

6314

1785

5810

Custom

2058

6322

6322

1185

5810*

Custom

3101

6324

6322

1785

5810*

Custom

2353

6324

6322

*1.0 SF
Data subject to change without notice.

17

POWER FACTOR %

If data is not shown, contact a Baldor office.


Contact a Baldor office for latest capabilities.

www.baldor.com

Performance Data
TEFC NEMA Premium Efficiency 2300 or 4160 Volts, 60 Hz, 1.15 SF
AMPS @
4160V

HP

200

250

300

350

400

450

500

600

kW

149

187

224

261

298

336

373

448

700

522

800

600

EFFICIENCY %
RATED
TORQUE
FULL LOCKED LB. FT.
FULL
1/2
3/4
LOAD ROTOR
LOAD

POWER FACTOR %

BEARINGS

1/2

3/4

FULL
LOAD

D.E.

O.D.E.

94.1

82

89

92

6314

6314

94.5

94.1

85

89

89

6319

6314

94.8

94.5

81

85

85

6319

6314

93.5

93.9

93.6

73

77

77

6322

6222

367

94.4

95.1

95.0

86

90

91

6314

6314

734

92.7

94.5

95.0

81

87

89

6322

6222

380

1104

93.8

94.6

95.0

78

83

85

6324

6222

194

1475

92.9

93.8

94.1

69

74

77

6322

6222

36

260

440

94.7

95.3

95.4

88

91

92

6314

6314

ECP50304L-2341

37

239

880

93.4

94.9

95.4

83

88

90

6322

6222

ECP50306L-2341

40

505

1104

93.9

94.5

95.0

78

82

86

6324

6222

Custom

43

239

1770

93.4

94.7

94.5

55

67

75

6322

6222

5007SY

Custom

42

292

518

95.1

95.3

95.4

86

90

91

6314

6314

5011LY

ECP50354L-2341

43

285

1111

94.3

95.1

95.4

83

88

89

6322

6222

1185

5011LY

ECP50356L-2341

46

300

1545

93.9

94.6

95.0

75

83

85

6324

6222

890

5810

Custom

47

293

2065

94.2

95.1

95.0

74

80

83

6326

6322

3570

5007SY

ECP50402S-2341

48

332

587

94.8

95.5

95.4

86

91

91

6314

6314

1790

5011LY

ECP50404L-2341

50

323

1174

93.8

95.0

95.4

82

87

89

6322

6222

1185

5011LY

ECP50406L-2341

52

349

1765

93.9

94.8

95.0

74

82

86

6324

6222

890

5810

Custom

54

351

2360

94.0

95.1

95.0

73

80

82

RPM

FRAME

CATALOG #

3570

447TS

Custom

25

159

294

93.1

94.1

1780

5007L

Custom

25

152

589

94.0

1185

5009L

Custom

27

174

890

94.4

890

50011L

Custom

29

150

1180

3570

5007SY

ECP50252S-2341

31

216

1790

5007L

ECP50254L-2341

31

214

1185

5009L

ECP50256L-2341

30

890

5011LY

Custom

36

3570

5007SY

ECP50302S-2341

1790

5009L

1185

5011LY

890

5011LY

3570
1790

3580

5007SY

Custom

55

558

660

95.0

95.6

95.4

88

90

92

6314

6314

1790

5011LY

ECP50454L-2341

56

364

1320

94.4

95.2

95.4

83

88

89

6322

6222

1190

5011LY

ECP50456L-2341

68

283

1985

93.7

95.0

95.4

60

70

75

6324

6222

890

5810

Custom

2654

3570

5009SY

ECP50502S-2341

60

401

734

95.4

96.0

95.8

87

90

92

6314

6314

1790

5011LY

ECP50504L-2341

60

386

1467

96.1

96.2

95.8

85

89

90

6322

6222

1190

5011LY

ECP50506L-2341

72

314

2204

93.9

95.2

95.4

59

69

75

6324

6222

890

5810*

Custom

2950

3570

5009SY*

Custom

72

379

883

95.8

95.9

95.6

92

91

91

6314

6314

1790

5011LY

Custom

73

458

1760

94.1

95.1

95.4

88

90

90

6322

6222

1185

5810

Custom

74

509

2645

94.6

95.5

96.2

80

85

89

6324

6322

1785

5810

Custom

96

584

2343

93.9

94.8

95.4

91

92

92

6322

6322

1185

5810*

Custom

96

585

3081

95.1

95.8

95.9

71

75

79

6324

6322

1785

5810*

Custom

174

577

2343

95.0

95.2

95.4

90

91

92

6322

6322

*1.0 SF
Data subject to change without notice.

If data is not shown, contact a Baldor office.


Contact a Baldor office for latest capabilities.

www.baldor.com

18

Performance Data
TEBC Vector Drive Motors 460 Volts, 60 Hz, 1.0 SF
HP

kW

RPM

250
300
350
400
450
500

187
224
261
298
336
373

1780
1785
1785
1785
1790
1790

AMPS @ 460V RATED


TORQUE
FULL LOCKED LB. FT.
FRAME CATALOG #
LOAD ROTOR
449TC
Custom
276
1720
740
449TC
Custom
333
2500
883
449TC
Custom
388
2750
1032
5007L
Custom
432
2766
1172
5007L
Custom
492
3075
1320
5009L
Custom
540
3487
1465

EFFICIENCY %
1/2

3/4

93.9
95.1
95.3
95.5
95.3
95.1

94.9
95.8
95.6
96.2
96.3
95.9

FULL
LOAD
95.8
95.8
95.8
96.2
96.5
96.8

POWER FACTOR
%
FULL
1/2 3/4
LOAD
79
86
89
81
86
88
83
87
89
85
89
91
85
89
91
84
88
90

BEARINGS
D.E. O.D.E.
6314
6314
6314
6222
6222
6222

6319
6319
6319
6322
6322
6322

MAX
Speed
2400
2400
2400
1800
1800
1800

ODP High Efficiency 460 Volts, 60 Hz, 1.15 SF


HP

kW

RPM

FRAME

CATALOG #

400
400
450
450
500
500
600
600

298
298
336
336
373
373
448
448

3550
1780
3550
1780
3550
1780
3550
1780

449TS
449T
449TS
449T
5009S
5009L
5009S
5009L

M25402T-4
M25404T-4
M25452T-4
M25454T-4
Custom
Custom
Custom
Custom

AMPS @ 460V RATED


TORQUE
FULL LOCKED LB. FT.
LOAD ROTOR
440
2544
591
448
3110
1179
488
2900
663
506
3200
1327
532
3459
732
582
3381
1467
652
4068
882
658
3476
1760

POWER FACTOR
%
FULL
FULL
1/2 3/4
LOAD
LOAD
93.6
85
89
91
94.5
79
86
87
94.1
85
89
91
94.5
80
86
88
95.8
82
88
90
95.8
80
82
85
95.8
87
89
90
96.2
87
90
90

EFFICIENCY %
1/2

3/4

94.8
94.4
95.2
95.2
95.4
95.2
95.1
96.2

94.5
94.7
95.0
95.1
96
95.5
95.9
96.4

BEARINGS
D.E. O.D.E.
6314
6321
6314
6321
6217
6222
6217
6222

6314
6314
6314
6314
6217
6222
6217
6222

ODP/WPI High Efficiency, 2300/4160 V, 60 Hz, 1.15 SF


POWER FACTOR
AMPS @ 460V RATED
EFFICIENCY %
BEARINGS
%
TORQUE
FULL LOCKED LB. FT.
FULL
FULL
1/2
3/4
1/2 3/4
D.E. O.D.E.
LOAD ROTOR
LOAD
LOAD

HP

kW

RPM

FRAME

CATALOG #

300

224

3560

449T

Custom

37

240

442

92.7

93.8

94.1

85

89

92

6314

6314

300

224

1785

5009L

Custom

38

224

883

94.1

94.6

94.5

82

87

89

6222

6222

400

298

3580

5009S

Custom

49

557

587

94

94.8

95

84

88

90

6217

6217

400

298

1790

5009L

Custom

52

329

1174

93.3

95.1

95

81

86

86

6222

6222

500

373

3580

5009S

Custom

61

401

735

95.2

95.6

95.4

85

88

90

6217

6217

500

373

1790

5009L

Custom

64

427

1468

93.7

94.5

95

82

85

87

6222

6222

600

448

3580

5009S

Custom

72

462

881

94.7

95.5

95.8

84

88

90

6217

6217

600

448

1790

5009L

Custom

76

416

1763

93.7

94.8

95.4

80

85

88

6222

6222

TEFC Explosion Proof 460 Volts, 60 Hz, 1.15 SF


POWER FACTOR
AMPS @ 460V RATED
EFFICIENCY %
BEARINGS
%
TORQUE
FULL LOCKED LB. FT.
FULL
FULL
1/2
3/4
1/2 3/4
D.E. O.D.E.
LOAD ROTOR
LOAD
LOAD

HP

kW

RPM

FRAME

CATALOG #

200

150

1785

447T

M74204T-4

218

1448

588

95.0

95.5

95.4

80

88

90

6319

6314

250

187

1785

449T

M74254T-4

272

1774

736

94.8

95.6

95.4

79

87

90

6319

6314

300

224

1785

449TY

M74304T-4

328

2241

883

95.1

95.8

95.8

80

88

90

6319

6314

If data is not shown, contact a Baldor office.


Data subject to change without notice.

19

Contact a Baldor office for latest capabilities.

www.baldor.com

Common Custom Motor Options


Electrical

Bearing RTDs

Winding RTDs , Thermistors or Thermostats

Special Design C or D Windings

Fabricated Copper Bar Rotors (5000 frame and up)

Complete Electrical Tests, Heat Runs and

Assorted Tests (Witnessed and Unwitnessed)

Multi-speed Motors

Surge Protection/lighting arrestors

Various tests
5000 frame TEFC motor with Renk sleeve bearings and RTD.

Mechanical

Metric Dimensions on Frame and Shaft

Roller Bearing

Renk Sleeve Bearings

Special Grease

Larger Diameter Shaft

Longer Shaft Length

Double Shaft Extensions

Space Heaters

WPII Enclosure Hoods (5000 frame and up)

IEEE 841 Features

Speed Feedback Devices

Low audible noise designs available

Conduit Box Volumes


Motor
Frame Size

Baldor Volume
In3

NEMA Minimum Volume


In3

NPT
Hole Size

444T/445T

600

600

2.5

445T/447T

600

600

2.5

447T/449T

1570

840

5005/5006/5007

2100

2000

4 (2)

5008/5009

2100

2000

4 (2)

5010/5011

2100

2000

4 (2)

5808/5809/5810/5812

3000

N/A

4 (3)

Note: All Cast Iron construction. Lead separator gasket between box and frame is a neoprene rubber cone design for a water-tight seal around the lead wires.
Conduit box lid gasket is neoprene rubber. Grounding provision is located inside the conduit box. Additional and/or larger conduit boxes are available.

www.baldor.com

20

Dimensions

ODP 447T / 449T


C

P
N

AB

GREASE FITTING
(EACH END)

V
KEY
O
U

2F

E
AC

AA

BA

H
NEMA
FRAME
447TS
447T
449TS
449T

2F

AA

AB

BA

21.5
21.5
21.5
21.5

28
28
28
28

44.38
48.12
44.38
44.12

11
11
11
11

9
9
9
9

20 & 25
20 & 25
20 & 25
20 & 25

.81
.81
.81
.81

5.13
8.87
5.13
8.87

22.47
22.47
22.47
22.47

22.93
22.93
22.93
22.93

2.375
3.375
2.375
3.375

4.75
8.5
4.75
8.5

4-NPT
4-NPT
4-NPT
4-NPT

20.47
20.67
20.47
20.67

7.5
7.5
7.5
7.5

ODP / WPI 449 / 5000 / 5800


C
P

LIFTING
PROVISIONS

N-W
V
AIR
IN

AIR
IN

2.81

AB

AIR
OUT

KEY
O

U
D

2F

AC
H

2F
NEMA
FRAME
449TS
449T
5009S
5009L
5011S
5011L
5808S
5808L
5810S
5810L

1 NPT

4 NPT
AA

BA

2F

N-W

21.53
21.53
30.06
30.06
30.06
30.06
35.50
35.50
35.50
35.50

28.00
28.00
36.40
36.40
43.40
43.40
38.63
38.63
44.63
44.63

44.42
48.18
51.75
56.62
59.75
64.62
54.25
60
62.25
68

11.00
11.00
12.50
12.50
12.50
12.50
14.50
14.50
14.50
14.50

9.00
9.00
10.00
10.00
10.00
10.00
11.50
11.50
11.50
11.50

20 & 25
20 & 25
22 & 25 & 28
22 & 25 & 28
32 & 36
32 & 36
22 & 25 & 28
22 & 25 & 28
28 & 32 & 36
28 & 32 & 36

0.81
0.81
0.94
0.94
0.94
0.94
1.18
1.18
1.18
1.18

4.75
8.50
6.75
11.62
6.75
11.62
6.75
12.50
6.75
12.50

22.38 24.90 2.375


22.38 24.90 2.375
28.32 38 2.500
28.32 38 3.875
28.32 38 2.500
27.57 38 3.875
33.25 44 3.375
33.25 44 4.125
33.38 44 3.375
33.38 44 4.875

AA

AB

AC

BA

4.50
8.250
6.50
11.12
6.50
11.12
6.50
9.00
6.50
9.00

4-NPT
4-NPT
4-NPT
4-NPT
4-NPT
4-NPT
4-NPT
4-NPT
4-NPT
4-NPT

21.40
21.40
27.87
28.50
28.75
28.75
32.00
32.00
32.00
32.00

16.75
16.75
21.90
22.50
22.75
22.75
25.88
25.88
25.88
25.88

7.50
7.50
8.50
8.50
8.50
8.50
9.75
9.75
9.75
9.75

Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also
be available from our CD-ROM or website at www.baldor.com.

21

www.baldor.com

Dimensions

WPII 5000/5800
P

C
AB

AIR EXHAUST

2.81

AIR
INTAKE

3.5
2.0

V
3.12

N-W

SOLID COVER

4.7

BA

2E

2F

2F

NEMA
FRAME

AC

AA

2F

N-W

AA

AB

AC

BA

5009S

30.06 36.40

54.88

12.50

10.00

22 & 25 & 28

0.94

6.75

51.75

30

2.500

6.50

4-NPT 28.50

22.50

8.50

5009L

30.06 36.40

59.75

12.50

10.00

22 & 25 & 28

0.94

11.62

51.75

30

3.875

11.12

4-NPT 28.50

22.50

8.50

5011S

30.06 43.40

62.88

12.50

10.00

32 & 36

0.94

6.75

51.75

32.13

2.500

6.50

4-NPT 29.50

22.00

8.50

5011L

30.06 43.40

67.75

12.50

10.00

32 & 36

0.94

11.62

51.75

32.13

3.875

11.12

4-NPT 29.50

22.00

8.50

5808S

35.50 38.63

57.37

14.50

11.50

22 & 25 & 28

1.18

6.75

60

39

3.375

6.50

4-NPT 33.31

27.20

9.75

5808L

35.50 38.63

63.0

14.50

11.50

22 & 25 & 28

1.18

11.25

60

39

4.125

9.00

4-NPT 33.31

27.20

9.75

5810S

35.5

44.63

65.37

14.50

11.50

28 & 32 & 36

1.18

6.75

60

39

3.375

6.50

4-NPT 33.31

27.20

9.75

5810L

35.5

44.63

71.0

14.50

11.50

28 & 32 & 36

1.18

11.25

60

39

4.875

9.00

4-NPT 33.31

27.20

9.75

Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also
be available from our CD-ROM or website at www.baldor.com.

www.baldor.com

22

Dimensions

TEFC 447T / 449T


P

C
AB

GREASER & RELIEF


(EACH END)

KEY

SLINGER

O
U

2F

BA

AA

AC
A

B
NEMA
FRAME

4411TS

21.75

36.70

57.05

11.00

9.00

4411TY

21.75

36.70

61.23

11.00

9.00

447TS

21.75

23.75

44.00

11.00

9.00

16.5 & 20

447T

21.75

23.75

47.75

11.00

9.00

16.5 & 20

449TS *

21.75

28.75

48.90

11.00

9.00

449TS

21.75

28.75

48.90

11.00

9.00

449T

21.75

28.75

52.65

11.00

449TY

21.75

28.75

54.35

11.00

2F

AA

AB

BA

25 & 28 & 32 0.81

4.93

22.94

25.25

2.375

4.75

4NPT

21.71

7.50

25 & 28 & 32 0.81

9.11

22.94

25.25

3.375

8.50

4NPT

21.71

7.50

0.81

6.44

22.94

24.56

2.375

4.75

3 NPT

20.57

7.50

0.81

8.93

22.94

24.56

3.375

8.50

3 NPT

20.43

7.50

20 & 25

0.81

4.93

22.94

24.56

2.375

4.75

4-NPT

21.71

7.50

20 & 25

0.81

5.19

22.94

24.56

2.375

4.75

4-NPT

21.71

7.50

9.00

20 & 25

0.81

8.94

22.94

24.56

3.375

8.50

4-NPT

21.71

7.50

9.00

20 & 25

0.81

9.11

22.94

24.56

3.375

8.50

4-NPT

21.71

8.50

*2-pole only, Design has shaft end bearing cooling fan

TEFC 5000
P

C
AB

V
O

U
3/4 NPT
2NPT

N-W
H

2F

BA

AC

AA

B
NEMA
FRAME

Poles

2F

N-W

5007SY

25.65

28.4

54.03

12.50

10.00

18 & 20 & 22

5007L

4&6

25.65

28.4

56.93

12.50

10.00

18 & 20 & 22

5009SY

25.65

34.4

60.03

12.50

10.00

5009L

4&6

25.65

34.4

62.93

12.50

5011LY

4&6

25.65

42.4

72.05

12.50

AA

AB

BA

0.94

6.75

26.84

29.90

2.500

6.50

4-NPT 26.88

9.87

0.94

11.62

26.84

29.90

3.875

11.12 4-NPT 26.88

8.50

25 & 28

0.94

6.75

26.84

29.90

2.500

6.50

4-NPT 26.88

9.87

10.00

25 & 28

0.94

11.62

26.84

29.90

3.875

11.12 4-NPT 26.88

8.50

10.00

32 & 36

0.94

11.54

26.84

29.90

3.875

11.12 4-NPT 26.88

9.71

Note: Drawings shown are for reference only. Please contact Baldor for a
detailed dimensional drawing of the specific motor you require. Drawings
may also be available from our CD-ROM or website at www.baldor.com.

23

www.baldor.com

Dimensions

TEFC 5800
P

C
AB

KEY
V
O
U
D

4 NPT
AA
N-W

1 NPT

AC
A

B
NEMA
FRAME

BA

2F

2F

N-W

AA

AB

AC

BA

5810

32.00 42.40 75.18 14.50 11.50 28 & 32 & 36

1.18

12.50

34.00

33.00

4.125

11.00 4-NPT 30.19

24.50

11.38

5812

32.00 51.40 81.77 14.50 11.50

1.18

9.00

34.00

33.00

4.125

8.75

24.50

11.84

40 & 45

4-NPT 30.19

Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also be available from
our CD-ROM or website at www.baldor.com.

www.baldor.com

24

Dimensions
TEBC Inverter/Vector
C

46.9

VOLUME
160 IN 3

17.59
9.65

42.5 REF.

AB
N-W
V
U

1/2 NPT
C/BOX FOR
BLOWER MOTOR
3.79

H HOLE

449TC* 21.75 28.75 64.37 11.00 9.00

1.44
2-NPT

AC

2F
B

ENCODER MTG.
(OPPOSITE SIDE)

NEMA
FRAME

4.7

AA HOLE

BA

1/4 DIA.
TYP. 4

G
2C
A

2F

20 & 25

0.81

N-W

24.55 24.55 3.375

AA

AB

AH

AJ

AK

BA

8.5 4-NPT 21.71 8.25 14.00 16.00 7.50

5007L

25.65 28.40 68.06 12.50 10.00 18 & 20 & 22 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88

8.50

5009L

25.65 34.40 74.05 12.50 10.00

25 & 28

0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88

8.50

5011LY 25.60 42.40 85.87 12.50 10.00

32 & 36

0.94 11.54 26.84 29.90 3.875 11.12 4-NPT 26.88

9.71

5810

32.00 42.40 87.96 14.50 11.50 28 & 32 & 36 1.18 12.50 34.00 33.00 4.125 11.00 4-NPT 30.19

11.38

5812

32.00 51.40 95.96 14.50 11.50

11.38

40 & 45

1.18 12.50 34.00 33.00 4.125 11.00 4-NPT 30.19

BB

BD

TAP

0.25 16.75 5/8-11

* Only 449TC stock motor designs have frame with standard C-face
Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also be available from
our CD-ROM or website at www.baldor.com.

25

www.baldor.com

Dimensions
TEFC Explosion Proof 449T
C

P
N
V

AB

KEY
O

BA

2F
H

AC

AA

GREASE RELIEF
(EACH END)
NEMA
FRAME

2F

H-W

AA

AB

BA

445TS

21.75

20.25

40.50

11.00

9.00

14.5 & 16.5

0.81

4.90

22.91

24.81

2.375

4.75

3-NPT

23.6

7.50

445T

21.75

20.25

44.25

11.00

9.00

14.5 & 16.5

0.81

8.75

22.91

24.81

3.375

8.50

3-NPT

23.6

7.50

449TS

21.75

28.75

49.00

11.00

9.00

20 & 25

0.81

4.94

22.94

24.81

2.375

4.75

3-NPT

27.67

7.50

449T

21.75

28.75

52.75

11.00

9.00

20 & 25

0.81

8.72

22.94

24.81

3.375

8.50

3-NPT

27.67

7.50

449TY

21.75

28.75

54.25

11.00

9.00

20 & 25

0.81

8.72

22.94

24.81

3.375

8.50

3-NPT

27.67

9.00

Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also be
available from our CD-ROM or website at www.baldor.com.

Limited Warranty
Three years on Super-E, 24 months on Standard-E, 18 months on most other motors, 5 years on IEEE841.

www.baldor.com

26

Connection Diagrams Main Motor Power Leads


9 Lead
Wye-Connected Motor
OPTIONAL T'STATS

P1

LOW VOLTAGE

HIGH VOLTAGE

2Y
5

1Y
6

8
2

9
3

4
4

7
1
P2

6 9

7
1

8
2

9
3

LINE

LINE

9 Lead
Delta-Connected Motor
OPTIONAL T'STATS
P1
1

47

LOW VOLTAGE
(2D)
7
8 9
6

4
2

HIGH VOLTAGE
(1D)
7
8 9

P2
LINE
3

Notes:
1. Three lead motors may be designed as either wye-connected or delta-connected.
2. Interchange any two line leads to reverse rotation.
3. Optional thermostats are provided when specified.
4. Actual number of internal parallel circuits may vary.

27

www.baldor.com

LINE

Connection Diagrams Main Motor Power Leads


3 Lead
TYPICAL WYE- CONNECTED MOTOR
1

TYPICAL DELTA - CONNECTED MOTOR

P1

P1
1

OPTIONAL T'STATS
P2
3

2
OPTIONAL T'STATS

3
P2
3

LINE

Notes:
1. Three lead motors may be designed as either wye-connected or delta-connected.
2. Interchange any two line leads to reverse rotation.
3. Optional thermostats are provided when specified.
4. Actual number of internal parallel circuits may vary.

NEMA Standard Lead Markings


Lead Marking

Motor

Power Leads

T1, T2, T3, etc.

Thermostat

P1, P2, etc.

Space Heater

H1, H2, H3, H4, etc.

Winding Resistance Temperature


Detector (RTD)

R1, R2, R3, R4, etc.

www.baldor.com

28

Encoder Receptacle Connections


For Vector Drive Motors
PIN

FUNCTION

Z(C)

VDC (5-15 VDC Standard)

Shield

Circuit Ground

Case Ground

A Compliment (A)

B Compliment (B)

Z (C) Compliment (Z or C)

A
B

H
K

E
F

Standard Receptacle MS3112E12-10P (Baldor Part # WD1434)


Standard Plug
MS3116J12-10S (Baldor Part # WD1435)
Both receptacle and plug are provided with the motor. Note that together these connections are weatherproof.

Mod-Express
In addition to the Chemical Processing motors shown in this brochure that are available from stock, customized
motors are available for special requirements on OEM applications. Baldors short lead times
can supply the motor for your specific application with special voltage, base speed, Design C torque, C-Face,
D-Flange, IEC metric dimensions, or other application-based needs. Special motors are in use on mixers,
aerators, crushers, centrifuges, hoists, pumps, and HVAC equipment.
Motors may be taken from Baldors Fort Smith inventory and modified through our Mod-Express program.
These modifications include:

Dynamic Balance of Rotor

Inpro Seal

F-2 Conversion

Special Performance Tests

Roller Bearings

Bearing Thermocouples, Thermistors or RTDs

Space Heaters

Winding Thermocouples, Thermistors or RTDs

Vibration Levels
Vibration levels are in accordance with NEMA MG-1 section 12.06.

29

www.baldor.com

www.baldor.com

30

Contact your nearest Baldor District Office at these


World Wide locations, or visit www.baldor.com
UNITED STATES
ARIZONA
PHOENIX
4211 S 43RD PLACE
PHOENIX, AZ 85040
PHONE: 602-470-0407
FAX: 602-470-0464
ARKANSAS
CLARKSVILLE
1001 COLLEGE AVE.
CLARKSVILLE, AR 72830
PHONE: 479-754-9108
FAX: 479-754-9205
CALIFORNIA
LOS ANGELES
6480 FLOTILLA
COMMERCE, CA 90040
PHONE: 323-724-6771
FAX: 323-721-5859
HAYWARD
21056 FORBES STREET
HAYWARD, CA 94545
PHONE: 510-785-9900
FAX: 510-785-9910

COLORADO
DENVER
2520 W BARBERRY PLACE
DENVER, CO 80204
PHONE: 303-623-0127
FAX: 303-595-3772
CONNECTICUT
WALLINGFORD
65 SOUTH TURNPIKE ROAD
WALLINGFORD, CT 06492
PHONE: 203-269-1354
FAX: 203-269-5485
FLORIDA
TAMPA/PUERTO RICO/
VIRGIN ISLANDS
3906 EAST 11TH AVENUE
TAMPA, FL 33605
PHONE: 813-248-5078
FAX: 813-247-2984
GEORGIA
ATLANTA
62 TECHNOLOGY DR.
ALPHARETTA, GA 30005
PHONE: 770-772-7000
FAX: 770-772-7200
ILLINOIS
CHICAGO
1601 Frontenac Road
Naperville, IL 60563
PHONE: 630-848-5100
FAX: 630-848-5110

INDIANA
INDIANAPOLIS
5525 W. MINNESOTA STREET
INDIANAPOLIS, IN 46241
PHONE: 317-246-5100
FAX: 317-246-5110
800-428-4141
IOWA
DES MOINES
1800 DIXON STREET, SUITE C
DES MOINES, IA 50316
PHONE: 515-263-6929
FAX: 515-263-6515
MARYLAND
BALTIMORE
6660 SANTA BARBARA RD.
SUITE 22-24
ELKRIDGE, MD 21075
PHONE: 410-579-2135
FAX: 410-579-2677
MASSACHUSETTS
BOSTON
6 PULLMAN STREET
WORCESTER, MA 01606
PHONE: 508-854-0708
FAX: 508-854-0291
MICHIGAN
DETROIT
33782 STERLING PONDS BLVD.
STERLING HEIGHTS, MI 48312
PHONE: 586-978-9800
FAX: 586-978-9969




GRAND RAPIDS
668 3 MILE ROAD NW
GRAND RAPIDS, MI 49504
PHONE: 616-785-1784
FAX: 616-785-1788

MINNESOTA
MINNEAPOLIS
21080 134TH AVE. NORTH
ROGERS, MN 55374
PHONE: 763-428-3633
FAX: 763-428-4551
MISSOURI
ST LOUIS
422 INDUSTRIAL DRIVE
MARYLAND HEIGHTS, MO 63043
PHONE: 314-298-1800
FAX: 314-298-7660




KANSAS CITY
1501 BEDFORD AVENUE
NORTH KANSAS CITY, MO 64116
PHONE: 816-587-0272
FAX: 816-587-3735

Baldor Electric Company


BR435

NEW YORK
AUBURN
ONE ELLIS DRIVE
AUBURN, NY 13021
PHONE: 315-255-3403
FAX: 315-253-9923
NORTH CAROLINA
GREENSBORO
1220 ROTHERWOOD ROAD
GREENSBORO, NC 27406
P O BOX 16500
GREENSBORO, NC 27416
PHONE: 336-272-6104
FAX: 336-273-6628
OHIO
CINCINNATI
2929 CRESCENTVILLE ROAD
WEST CHESTER, OH 45069
PHONE: 513-771-2600
FAX: 513-772-2219




CLEVELAND
8929 FREEWAY DRIVE
MACEDONIA, OH 44056
PHONE: 330-468-4777
FAX: 330-468-4778

OKLAHOMA
TULSA
2 EAST DAWES
BIXBY, OK 74008
PHONE: 918-366-9320
FAX: 918-366-9338
OREGON
PORTLAND
20393 SW AVERY COURT
TUALATIN, OR 97062
PHONE: 503-691-9010
FAX: 503-691-9012
PENNSYLVANIA
PHILADELPHIA
1035 THOMAS BUSCH
MEMORIAL HIGHWAY
PENNSAUKEN, NJ 08110
PHONE: 856-661-1442
FAX: 856-663-6363




PITTSBURGH
616H BEATTY ROAD
MONROEVILLE, PA 15146
PHONE: 412-380-7244
FAX: 412-380-7250

TENNESSEE
MEMPHIS
4000 WINCHESTER ROAD
MEMPHIS, TN 38118
PHONE: 901-365-2020
FAX: 901-365-3914

TEXAS
HOUSTON
4647 PINE TIMBERS
SUITE # 135
HOUSTON, TX 77041
PHONE: 713-895-7062
FAX: 713-690-4540




DALLAS
3040 QUEBEC
DALLAS, TX 75247
PHONE: 214-634-7271
FAX: 214-634-8874

UTAH
SALT LAKE CITY
2230 SOUTH MAIN STREET
SALT LAKE CITY, UT 84115
PHONE: 801-832-0127
FAX: 801-832-8911
WISCONSIN
MILWAUKEE
2725 SOUTH 163RD STREET
NEW BERLIN, WI 53151
PHONE: 262-784-5940
FAX: 262-784-1215
INTERNATIONAL SALES
FORT SMITH, AR
P.O. BOX 2400
FORT SMITH, AR 72902
PHONE: 479-646-4711
FAX: 479-648-5895
CANADA
EDMONTON, ALBERTA
4053-92 STREET
EDMONTON, ALBERTA T6E 6R8
PHONE: 780-434-4900
FAX: 780-438-2600

OAKVILLE, ONTARIO
2750 COVENTRY ROAD
OAKVILLE, ONTARIO L6H 6R1
PHONE: 905-829-3301
FAX: 905-829-3302

MONTREAL, QUEBEC
1844 WILLIAM STREET
MONTREAL, QUEBEC H3J 1R5
PHONE: 514-933-2711
FAX: 514-933-8639

WINNIPEG, MANITOBA
54 PRINCESS STREET
WINNIPEG, MANITOBA R3B 1K2
PHONE: 204-942-5205
FAX: 204-956-4251

VANCOUVER,
BRITISH COLUMBIA
1538 KEBET WAY
PORT COQUITLAM, BC V3C 5M5
PHONE 604-421-2822
FAX: 604-421-3113

AUSTRALIA
UNIT 3, 6 STANTON ROAD
SEVEN HILLS, NSW 2147,
AUSTRALIA
PHONE: (61) (2) 9674 5455
FAX: (61) (2) 9674 2495




UNIT 8, 5 KELLETTS ROAD


ROWVILLE, VICTORIA, 3178
AUSTRALIA
PHONE: (61) (3) 9753 4355
FAX: (61) (3) 9753 4366

Amrica DEL SUR


Aptdo. 9109 0818 Zona 6
Bethania,
Ciudad de Panam, Panam
PHONE: +507 261-5347
Fax: +507 261-5355
Centro Amrica y Caribe
RESIDENCIAL PINARES DE SUIZA
POL. 15 #44,
NVA. SAN SALVADOR,
EL SALVADOR
PHONE: +503 2288-1519
FAX: +503 2288-1518
CHINA
SHANGHAI JIAHUA
BUSINESS CENTER
ROOM NO. A-8421
808 HONG QIAO ROAD
SHANGHAI 200030
PHONE: 86-21-64473060
FAX: 86-21-64078620
GERMANY
DIESELSTRASSE 22
D-85551 KIRCHHEIM
MUNICH, GERMANY
PHONE: (49) (89) 90508 0
FAX: (49) (89) 90508 492
INDIA
14, COMMERCE AVENUE
MAHAGANESH COLONY
PAUD ROAD
PUNE - 411 038
MAHARASHTRA, INDIA
PHONE: 91 20 25 45 95 30
FAX: 91 20 5 4 95 30

KOREA
ROOM 208-37
INCHEON INDUSTRIAL GOODS
CIRCULATING CENTER
SONGHYEON 3-DONG, DONG-GU
INCHEON. KOREA, 401-705
PHONE: 82 32 588 3253
FAX: 82 32 588 3254
MXICO
KM. 2.0 BLVD. AL AEROPUERTO
LEN 37545, GUANAJUATO,
MXICO
PHONE: 52 477 761 2030
FAX: 52 477 761 2010
MIDDLE EAST & NORTH AFRICA
VSE INTERNATIONAL CORP.
3233 NORTH ARLINGTON HEIGHTS
SUITE 100W
ARLINGTON HEIGHTS, IL 60004
PHONE: 847 590 5547
SINGAPORE
51 KAKI BUKIT ROAD 2
K B WAREHOUSE COMPLEX
SINGAPORE 417863
PHONE: (65) 6 744 2572
FAX: (65) 6 747 1708
SWITZERLAND
POSTFACH 73
SCHUTZENSTRASSE 59
CH-8245 FEUERTHALEN
SWITZERLAND
PHONE: (41) (52) 6474700
FAX: (41) (52) 6592394
TAIWAN
4F, NO. 25, SEC. 1,
TUNHUA S ROAD,
TAIPEI 10557, TAIWAN, R.O.C.
PHONE: (886-2) 2577-4352
FAX: (886-2) 2577-4157
UNITED KINGDOM
6 BRISTOL DISTRIBUTION PARK
HAWKLEY DRIVE
BRISTOL BS32 0BF U.K.
PHONE: 44 1454 859000
FAX: 44 1454 8590019

ITALY
Baldor ASR AG
SUCCURSALE DI Mendrisio
Via Borromini, 20A
CH-6850 Mendrisio
Switzerland
PHONE: 41 91 640 9952
FAX: 41 91 630 2633
JAPAN
DIA BLDG 802,
2-21-1 TSURUYA-CHO,
KANAGAWA-KU
YOKOHAMA, 221-0835, JAPAN
PHONE: 81-45-412-4506
FAX: 81-45-412-4507

Baldor Electric Company


P.O. Box 2400
Fort Smith, AR 72902-2400 U.S.A
Ph (479) 646-4711 Fax (479) 648-5792
International Fax (479) 648-5895
www.baldor.com

Printed in U.S.A.
12/05 PROG 25,000

You might also like