HV Modular induction motors

Technical data for totally enclosed squirrel


cage three phase motors

6000 V - 50 Hz

IP 55 - IC 611 - Insulation class F, temperature rise class B


Efficiency
Output Motor
kW
type

Full
3/4
Product Speed load
load
ID
r/min 100 % 75 %

500 r/min = 12 poles

Power factor

Current

Torque

Full
3/4
load
load
100 % 75 %

IN

IS

I0

TN

TS

T max

IN

Nm

TN

TN

Rotor
inertia
kgm2

Motor
weight
kg

Sound
pressure
level LP
dB(A)

6000 V 50 Hz

180

AMI 400L12A

10274

494

91.4

90.9

0.65

0.57

29

3.9

19

3483

0.8

2.0

18.2

2960

76

200

AMI 400L12A

10275

492

91.6

91.3

0.68

0.62

31

3.7

18

3879

0.7

1.7

19.4

3050

76

224

AMI 400L12A

10276

492

91.7

91.7

0.70

0.64

33

3.5

18

4350

0.7

1.6

20.6

3140

76

245

AMI 400L12A

10277

493

92.2

92.0

0.71

0.65

36

4.0

20

4745

0.8

1.8

26.2

3320

76

280

AMI 450L12A

10278

493

93.5

93.7

0.76

0.71

38

4.3

19

5418

0.8

1.9

39.9

3850

76

315

AMI 450L12A

10279

493

93.6

93.8

0.77

0.72

42

4.2

20

6098

0.7

1.8

42.6

3960

76

355

AMI 450L12A

10280

493

93.7

94.0

0.77

0.72

47

4.1

22

6874

0.7

1.8

45.2

4080

76

400

AMI 450L12A

10281

493

93.9

94.1

0.77

0.72

53

4.2

25

7744

0.7

1.8

47.9

4200

76

450

AMI 450L12A

10282

494

93.9

94.0

0.75

0.69

61

4.5

31

8700

0.8

1.9

53.3

4410

76

500

AMI 500L12A

10283

493

94.5

94.7

0.78

0.74

65

4.3

29

9677

0.7

1.9

70.2

5100

76

560

AMI 500L12A

10284

494

94.6

94.8

0.78

0.73

73

4.4

34

10833

0.7

1.9

74.6

5250

76

630

AMI 500L12A

10285

494

94.8

95.0

0.78

0.74

82

4.4

37

12187

0.7

1.9

83.5

5550

76

710

AMI 500L12A

10286

494

94.9

95.1

0.78

0.73

92

4.6

43

13726

0.7

2.0

92.5

5850

76

800

AMI 500L12A

10287

494

95.1

95.2

0.78

0.73

104

4.8

49

15456

0.8

2.0

105.9

6290

76

900

AMI 560L12A B

10288

493

95.1

95.5

0.82

0.78

111

4.6

44

17422

0.7

2.1

159.7

7550

74

1000

AMI 560L12A B

10289

494

95.3

95.7

0.81

0.77

125

4.9

53

19341

0.8

2.2

167.8

7750

74

1120

AMI 560L12A B

10290

494

95.5

95.9

0.82

0.78

137

4.8

54

21663

0.7

2.2

191.9

8340

74

1250

AMI 560L12A B

10291

494

95.7

96.0

0.81

0.76

155

5.2

67

24149

0.8

2.4

208.0

8680

74

1400

AMI 560L12A B

10292

495

95.8

96.1

0.80

0.75

175

5.4

78

27029

0.9

2.5

232.2

9220

74

1600

AMI 560L12A B

10293

495

95.9

96.2

0.81

0.76

199

5.4

87

30891

0.9

2.4

256.3

9810

74

1800

AMI 630L12A B

10294

495

96.2

96.5

0.83

0.80

218

5.2

80

34696

0.9

2.1

335.1

11030

75

2000

AMI 630L12A B

10295

496

96.3

96.6

0.83

0.80

241

5.3

88

38537

0.9

2.1

378.2

11730

75

2240

AMI 630L12A B

10296

496

96.5

96.7

0.83

0.79

270

5.6

105

43097

0.9

2.3

438.8

12680

75

2500

AMI 630L12A B

10297

497

96.7

96.8

0.81

0.77

306

5.6

128

48045

0.8

2.4

514.8

13860

75

Data presented in rating lists are typical values. Guaranteed values on request.
All engineered motors are optimized for the specified application.
Accurate motor data will be given on request at quotation phase.
Legally binding performance and specification data is given to the end user once each order is confirmed.

ABB | BU Motors and Generators | HV induction motors, technical catalog for IEC motors EN 09-2011 89