Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

The Welch Allyn PC-Based Resting ECG

Spend less time with paperwork


and more time with your patients.
Convert to digital PC-based ECG technology and boost
your efciency with the Welch Allyn PC-Based Resting ECG
Tired of printing, scanning and shredding ECG records?
Improve Workow and Efciency
> Preview a complete 12-lead report on large-screen prior to printing
and eliminate repeat ECGs
> ECG measurements speed physician review and interpretation
> Flexible reports that you can print on plain (standard) paper using
an inkjet or laser printer. No need for expensive thermal paper.
No more fading problems
Make Clinical Decisions with Condence
> Serial comparison of previous ECGs to highlight changes
> Easily monitor patients with intermittent arrhythmias
> Connect with your EHR and eliminate the need to sort through lengthy
paper reports or interpret hard-to-read faxed copies of test results
Efcient Diagnosis
Optional MEANS ECG interpretation software
available for both adults and pediatric patients.
Use on-screen report editor to change or add
a diagnosis in seconds. Or select from preset
menus customized to your needs, for simpli-
ed review and editing of diagnostic tests.

Improved Condition
Management
Easily monitor trends and changes in patient
history. Retrieve previous records with the
touch of a keyno more digging through
paper les looking for the right information.
Connect to your EHR
No printing or scanning, as data is already
in the chart. Fax urgent referrals in no
time directly from the system. And
the database stores thousands of
test records.
The process of patient data gathering using the Welch Allyn product is excellentnow I dont
have to read 30 and 40 pages of ECGs. Now with the Welch Allyn devices, you hit one button
and everything is there for you. The process is so streamlined now, and that allows me to
focus more on my patients.
Sasha Van Dyke, Exercise Physiologist, Cardiology of Tulsa
Bidirectional Connectivity Right at Your Fingertips
While most devices only push information out to the EHR, our bidirectional connec-
tivity when you use one of our 10 certied partners, enables immediate sharing of
patient demographics and then critical test data between the EHR and the ECG so
information is immediately available for review anytime, anywhere. The benet?
You eliminate transcription errors because you dont have to continually re-enter data.
Maximize the power of your PC-Based ECG with the paperless efciency
and connectivity of the Welch Allyn CardioPerfect

Workstation software.

Data Access Where and When You Need It
All the benets of a full-featured, PC-based ECG in an affordable solution that
speeds the turnaround of test results, makes patient diagnostic information more
readily available and enhances communication for you, your staff, and your patients.
2009 Welch Allyn SM4006 Rev A
4341 State Street Road, PO Box 220, Skaneateles Falls, NY 13153-0220
(p) 1.800.535.6663 (f) 1.315.685.2174 www.welchallyn.com
Technical Specications
Digital ECG module
Dimensions (L x W x D): 5.8" x 4.3" x 1.3" (147 mm x 108 mm x 32.5 mm)
Weight: 8.4 ounces (includes battery)
Integrated debrillation protection
Computer interface: USB
10-lead patient cable with banana electrode adapters
Frequency response: 0.05 150 Hz
Sampling rate: 600 sps
Filters
25 to 35 Hz muscle tremor lter
Selectable 50/60 Hz
Software
Monitoring formats: 1 x 12, 4 x 3, 2x6
Print formats: 4 x 3, 2 x 6, average complexes, expanded
measurements matrix and rhythm strips
Print speeds: 5, 10, 12.5, 25, 50 and 100 mm/sec
Lead sensitivity: 5, 10 and 20 mm/mV software
Selectable QTc formula: Bazett, Hodges or Fridericia

Minimum Computer Requirements (Recommended)
Conguration: Tower or Desktop PC preferred; Laptop or Tablet.
Some tablet computers may not support data recording
CPU: Pentium 4 (or equivalent) or higher
Hard disk: 20 GB with 5 GB free space
RAM: 512 MB, 1 GB or higher recommended
Monitor Rresolution: 1024 x 768 True Color, 1280 x 1024 recommended,
15 or higher
Ports: 2 USB
Operating system: Windows 2000 SP4, XP SP2 (32 bit) or later,
Vista Business SP1 (32 bit) or later
Peripherals: Color printer recommended for spirometry. Compatible
with inkjet and laser printers
NOTES: Internet connection required for telemedicine option or to allow
Welch Allyn to provide on-line technical support.
PC running only CardioPerfect Worksation and EHR application during tests.
Ordering Information
CPR-UN-UB-D PC-Based Resting ECG, noninterpretive software12-lead resting ECG system including:
CardioPerfect

Workstation software, digital ECG patient cable with USB connection, software
for resting ECGECG measurements, rhythm/manual mode, average complexes, serial compari-
sons of ECGs and measurements, 500 resting tab electrodes and electronic operators manual
CPR-UI-UB-D PC-Based Resting ECG, interpretive software12-lead resting ECG system including:
CardioPerfect

Workstation software, digital ECG patient cable with USB connection, software
for resting ECGECG measurements/interpretation, rhythm/manual mode, average complexes,
serial comparisons of ECGs and measurements, 500 resting tab electrodes and electronic
operators manual
101442 CPWS Resting ECG, interpretive software, and Spirometry Module Bundle
Includes all hardware components included in CPR-UI-UB-D and SPIRO-S
101444 CPWS Resting ECG, interpretive software, and ABPM-6100S Module Bundle
Includes all hardware components included in CPR-UI-UB-D and ABPM-6100S
101455 CPWS Resting ECG, interpretive software, and SpiroPerfect and ABPM-6100S Module
BundleIncludes all hardware components included in CPR-UI-UB-D, SPIRO-S and ABPM-6100S
CPT

Codes
93000 Electrocardiogram, routine ECG with at least 12 leads; with interpretation and report
93005 Tracing only, without interpretation and report
93017 Interpretation and report only
93040 Rhythm ECG1 to 3 leads, with interpretation and report
CPT is a registered trademark of the American Medical Association.
Welch Allyn PC-Based Resting ECG
Adult ECG 162.tif Enlarged complex.png
interp window copy.png
ECG comparison.png
ECG measurements window.png
Precise information.
Easier diagnoses. Better patient care.
The Welch Allyn SpiroPerfect

PC-Based Spirometer
I N T R O D U C I N G
Accurate, integrated patient information at your fingertips
Fast, reliable pre- and post-bronchodilator FVC, SVC and MVV
testing with automatic interpretation and reversibility analysis
> View real-time Flow/Volume Loop and Volume/Time graphs
> Instantly verify quality and variability of proper test performance
> Motivate children with incentive graphicfor pediatric
patient coaching
> Reduce risk of cross contamination with single-use
disposable transducers
> Select single and multiple flow calibration protocols
Easily monitor, review, store and print on your existing
computer with the Welch Allyn CardioPerfect

Workstation
> Choose from multiple predicted norms and report formats
> Compare previous tests with the Trending tool
> Make available to multiple staff via computer network
> Interface with Electronic Medical Records or patient
management systems for onsite or offsite review of key
data. Telemedicine option is available for e-mail transfer.
In seconds, you and your staff can see and compare accurate results from pulmonary function tests with the friendly, featherweight
Welch Allyn SpiroPerfect

PC-Based Spirometer. You can clearly evaluate pulmonary obstruction or restriction, increase success
rates of patients who are undergoing smoking cessation, show progress, and help pediatric patients comply with test procedures.
Integrated. Customizable. Intuitive.
1
2
3
4
5 Display real time curves
Customizable parameters
Automatic
interpretation
Identify type
and date
Patient
records
Store, retrieve, print or edit patient records using
the Welch Allyn CardioPerfect Workstation database.
Easily identify all diagnostic test types and dates
each procedure was performed.
Automatic interpretation follows ATS Interpretative
Strategies and test reproducibility criteria.
See a quick snapshot of patient results. Select from
6 parameters to show real-time testing and summary.
View measurement tables with 19 fully customizable
parameters.
Display real time curves as Flow/Volume, Volume/Time,
Flow/Time or Pre, Post. All efforts or best effort can be
displayed on the same graph for easy comparison.
1
2
3
4
5
Welch Allyn SpiroPerfect

PC-Based Spirometer
Transfers Test Data
to Electronic Medical
Records Systems
Enjoy the convenience of our accurate patented
Disposable Flow Transducers. Designed for use
by an adult or child, these single-use disposables
minimize the risk of cross contamination. No
sterilization, no cleanupjust safety and savings.
Get connected to your EMR through
Welch Allyns CardioPerfect

Workstation Software
The Welch Allyn SpiroPerfect

PC-Based Spirometer downloads information to the Welch Allyn CardioPerfect

Workstation
Software, which provides paperless efficiency as well as connectivity to many leading EMR systems. This software puts
patient records from a variety of Welch Allyn diagnostic instruments at your fingertips, giving you the ability to store, access,
review, compare and edit diagnostic test data from any computer on your network.
Retrieve records with the touch of a key, and review
and edit right on the screen
Store thousands of records with ease
Access information from your exam rooms, your office,
or at home
Fax or e-mail reports directly for consults
Add additional cardiopulmonary diagnostic testing devices
like ECG, ABPM, or Holter as your practice grows
Copy and paste spirographs into Microsoft

Word
Integrate with other patient information systems
Uses passwords to assign/limit tasks so that data
integrity is maintained
Coach, motivate and make testing more fun.
Because children understand how to help
the fireman put out the fire, the Incentive
Screen helps children understand your goals
and comply with testing protocols.
Compare tests done on different days and
clearly see progress. View three parameters
at once as a percentage of predictive values
or of absolute value.
Welch Allyn CardioPerfect

Workstation Software
Welch Allyn SpiroPerfect

PC-Based Spirometer
To learn more about the Welch Allyn SpiroPerfect PC-Based Spirometer or to request a demonstration, contact your Welch Allyn representative.
Youll find a solution that not only improves patient care, but provides priceless peace of mind.
Technical Specifications
SpiroPerfect Computer-based full diagnostic spirometer
Tests FVC, SVC, MVV, Pre- and Post-BD
Sensor Type Pneumotach
Power Equipment None, obtained from USB port
Accuracy Meets or exceeds 1994 ATS standard
Reproducibility Meets or exceeds 1994 ATS standard
Volume Range 0-14 L
Flow Range 14 L/sec
Software Microsoft

Windows

2000 and XP compatible


Predictive Norms Berglund 1963, Crapo 1981, Composite,
Dockery 1983, ECCS/Quanjer 1993,
Falaschetti 1995, Gulsvik 2001, Hedenstrm
1986, Hsu 1979, Knudson 1976, Koillinen 1998,
Kory 1961, Morris 1971, NHANES III 1999
[Default], Polgar 1971, Schoenberg 1978,
Solymar 1980, Viljanen 1981, Zapletal 1969
Additional predictive norms can be added upon customer request
Interpretation 1991 ATS Interpretation Standards. Automatic
can be disabled. Manual interpretation available.
Lung age calculation
Reports Multiple report templates including FVC, SVC,
MVV, measurement, and trend
Incentive Graphic Fireman
Parameters FVC, FIVC, FIV1, FIV1%, FEV0.5, FEV1, FEV2, FEV3,
FEV5, FEV6, FEV0.5%, FEV1%, FEV2%, FEV3%,
FEV5%, FEV6%, PEF, FEF25 (MEF75), FEF50
(MEF50), FEF75 (MEF25), FEF0.2-1.2, FEF25-75,
FEF75-85, PIF, FIF50, FEF50/FIF50, FET SVC, ERV,
IRV, VT, IC, BF, MV, Tin, Tex, Tin/Tex
Quality Checks Effort Acceptability and Test Reproducibility checks
Audio and visual incentive for assistance in
coaching patients
Connectivity Part of the CardioPerfect

Diagnostic Suite
Export compatible with most electronic medical
records programs
Available in multiuser network
Telemedicine option for e-mail transfer
Minimum Computer Requirements (Recommended)
Processor Intel

Pentium

III (Pentium IV or higher)


Hard Drive 2 GB (4 GB or more)
RAM 256 MB (512 MB or higher)
Monitor Resolution (1024 x 768 true color)
Operating Systems Microsoft

Windows

2000 or XP
CD-ROM Required for installation
Printers Color printer recommended. Compatible with
inkjet and laser printers. Laser printers require
a minimum of 2 MB of memory
Performance Standards
SpiroPerfect meets or exceeds the following standards:
ATSAmerican Thoracic Society, Standardization of Spirometry,
1994 Update
ERSEuropean Respiratory Society
NIOSHNational Institute for Occupational Safety and Health
OSHAOccupational Safety and Health Administration
SSDSocial Security Disability
ECCSEuropean Community for Coal & Steel
Ordering Information
SPIRO-S SpiroPerfect

PC-Based Spirometer Module: PC Spirometer Module with 3 L calibration syringe. Includes: sensor, pressure
tubing, 4 flow transducers, electronic operators manual, Welch Allyn CardioPerfect

Workstation Software CD, 2 training


posters, and quick reference card
SPIRO-NS SpiroPerfect

PC-Based Spirometer Module: PC Spirometer Module without 3 L calibration syringe. Includes sensor, pressure
tubing, 4 flow transducers, electronic operators manual, Welch Allyn CardioPerfect

Workstation Software CD, 2 training


posters, and quick reference card
703418 Disposable Spirometer Flow Transducer, 25 pk
703419 Disposable Spirometer Flow Transducer, 100 pk
703415 Pressure Tubing, 2 m
100680 Nose Clip (25 pk)
703480 Calibration Syringe (3 liters)
CPT Codes
94010 Basic SpirometrySpirometry including graphic record, total and timed vital capacity, expiratory flow rate measurement(s),
with or without maximal voluntary ventilation
94060 Pre- and Post-BDBronchospasm evaluation: spirometry as in 94010, before and after bronchodilator (aerosol or parental),
or before and after exercise
2005 Welch Allyn SM2863 Rev. B
4341 State Street Road, PO Box 220, Skaneateles, NY 13153-0220
(p) 1.800.535.6663 (f) 1.315.685.2174
www.welchallyn.com
Advantage #1: Our innovative design prevents cross-contamination.
The ai r i nsi de t he f l ow t ransducer' s measurement pi pe works as a buf f er, prevent i ng t he expi red ai r f rom ent eri ng t he pressure
t ubi ng even duri ng hi gh f l ow rat es (15 L/ s) and repeat ed spi romet ry ef f ort s.
The maxi mal di f f erent i al pressure si gnal of t he f l ow t ransducer i s 77 mm H2O, correspondi ng t o a f l ow of 15 L/ s. Average
at mospheri c pressure i s 10 000 mm H2O. The ai r i s t heref ore compressed i n t he pressure t ubi ng up t o
77 / 10 000 parts =0.77 %
In 2-met er l ong pressure t ubi ng, t hi s amount s t o
0.77 % x 2000 mm =15.4 mm
Si nce t he i nt ernal di amet er of t he pressure t ubi ng i s 1.5 mm, t he cross-sect i onal area i s 1.77 mm2. The amount of ai r ent eri ng
t he f l ow t ransducer' s measurement pi pe duri ng t he expi rat i on amount s t o
15.4 mm x 1.77 mm2 =27.2 mm3
Thi s i s t he maxi mal vol ume of expi red ai r ent eri ng t he measurement pi pe of t he f l ow t ransducer vi a t he pressure-sampl i ng hol e
at t he t op of t he measurement pi pe. In t he measurement pi pe, t he "cont ami nat ed" ai r wi l l st art movi ng t oward t he pressure
t ubi ng adapt er. The ai r ent eri ng t he measurement pi pe t hrough t he hol e at t he t op of t he measurement pi pe wi l l pot ent i al l y
reach t he pressure t ubi ng f i rst .
Because t he maxi mal vol ume of expi red ai r ent eri ng t he measurement pi pe of t he f l ow t ransducer i s 27.2 mm3, and t he ai r
vol ume i n t he measurement pi pe bet ween t he adapt er and pressure-sampl i ng hol e i s 136.3 mm3, t he ai r buf f er bet ween t he
cont ami nat ed ai r and t he pressure t ubi ng adapt er i s
136.3 mm3 - 27.2 mm3 =109.1 mm3
Thi s ai r buf f er prevent s t he aerosol s of t he cont ami nat ed ai r
f rom ent eri ng t he pressure t ubi ng even duri ng repeat ed f orced
expi rat ory ef f ort s. In sl ow ef f ort s, t he ai r ent eri ng t he measure-
ment pi pe i s even smal l er.
Advantages of Disposable Flow Transducers
No Expi red Ai r
Pressure Sampl i ng Hol e
Measurement Pi pe
Advantage #2: Bacteria filters are unnecessary.
Because no cont ami nat ed ai r ent ers t he pressure t ubi ng, and because t he f l ow t ransducers are di scarded af t er each pat i ent
use, no bact eri a f i l t ers are needed. In f act , because Wel ch Al l yn spi romet ers use a measuri ng pri nci pl e based on pressure
(pneumot achomet er), f i l t ers woul d i nt erf ere wi t h accuracy by addi ng resi st ance.
Advantage #3: Disposable flow transducers are more cost-
effective, accurate, and convenient.
When procedural cost s are t aken i nt o account , di sposabl e f l ow t ransducers cost l ess t han f l ow t ransducers t hat
requi re di si nf ect i ng.
A di si nf ect ed f l ow t ransducer may ret ai n sol i d part i cl es on t he screen or l i qui ds i n t he duct , compromi si ng accuracy.
Recal i brat i on i s requi red bef ore reusi ng a di si nf ect ed f l ow t ransducer, whereas new f l ow t ransducers f rom t he same
manuf act uri ng l ot do not requi re a separat e cal i brat i on.
Advantages of Disposable Flow Transducers
CUSTOMER SERVICE
For customer service, technical or clinical support, please contact Welch Allyn at (800) 535.6663.
4341 State Street Rd, PO Box 220, Skaneateles Falls, NY 13153
(p) 1.800.535.6663 (f) 1.315.685.2174
www.welchallyn.com
2005 Wel ch Al l yn. SM 2861 RevB

You might also like