Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Operator control and monitoring -

simple and cost-effective


...perfect for the SIMATIC S7-200
O
v
e
r
v
i
e
w


P
r
e
l
i
m
i
n
a
r
y

I
n
f
o
r
m
a
t
i
o
n
Bedienen_u_Beobachten_S7_200_en.fm Seite 1 Dienstag, 8. Mrz 2005 10:47 10
TD 100C TD 200 TD 200C OP 73micro TP 177micro WinCC flexible
Display Liquid crystal display (reflecting) Liquid crystal display Liquid crystal display Liquid crystal display
1)
LCD, STN, Blue Mode,
4 blue levels
1)
Description Innovative HMI software at
machine level for uniform con-
figuration of SIMATIC HMI
devices from the smallest
Micro Panel up to PC-based
solutions
Number of lines 4 2 2
Number of characters per line
(max.)
10/16 (ASCII/Cyrillic),
8 (Chinese)
20 (ASCII/Cyrillic),
10 (Chinese)
20 (ASCII/Cyrillic),
10 (Chinese)

Character height 3.34 mm 5 mm 5mm
Size 3" 5.7" Configurations Single-user system, fre-
quently on Panel PC basis
Supports distributed opera-
tor stations
Innovative servicing strate-
gy with e-mail, remote con-
trol, remote monitoring and
remote administration via
intranet/Internet
Resolution 160 x 48 pixels 320 x 240 pixels (240 x 320
pixels for vertical configuring)
Operator controls Membrane keyboard Membrane keyboard Membrane keyboard Membrane keyboard Touch screen
Function keys, programmable 14 freely-configurable 8 20 freely-configurable 4
System keys 5 8
Memory, integrated
(available for user data)
User data on CPU User data on CPU User data on CPU 128 KB flash 256 KB flash
Interfaces 1 PPI (RS485); for configuring a
network with max. 126 nodes
(S7-200, OP, TP, TBP, PG/PC);
transmission speeds
9.6/19.2/187.5 kbit/s
1 PPI (RS485); for configuring a
network with max. 126 nodes
(S7-200, OP, TP, TBP, PG/PC);
transmission speeds
9.6/19.2/187.5 kbit/s
1 PPI (RS485); for configuring a
network with max. 126 nodes
(S7-200, OP, TP, TBP, PG/PC);
transmission speeds
9.6/19.2/187.5 kbit/s
1 x RS 485 1 x RS 485 Engineering Uniform solutions
Fast configuration (precon-
figured objects, referenced
faceplates)
Spreadsheet editors for effi-
cient processing of mass data
Intelligent tools (project
agent, automatic compila-
tion and translation)
5 system languages
(plus 4 Asian)
Functionality
Messages
(freely-definable message classes)
40 80 80 250 500
Message buffer (no. of entries) 128 (no battery backup) 128 (no battery backup)
Process screens 32 64 64 250 250
Variables 288 864 864 500 250
Graphics objects Icons Bitmaps/icons/
background pictures
Bitmaps/icons/
background pictures
Runtime functionality
Process displays
Screen modules
Trends
Messages
Reports
Recipes
Archives
Database
User administration
Diagnostics
Runtime languages





(option: recipes)
(option: recipes)
((option: ext. ODBC database)

(option)
32 (device-specific)
Numeric input / alpha input / / / / /
Password
Online languages 1 5 5 5 5
Bar charts (pixel graphics)
Degree of protection
(front/back):
IP65, NEMA4 / IP20 IP65, NEMA4 / IP20 IP65, NEMA4 / IP20 IP65 (when installed), NEMA 4,
NEMA 4x, NEMA 12 / IP20
IP65 (when installed), NEMA 4,
NEMA 4x, NEMA 12 / IP20
Dimensions
Front panel (W x H in mm) 90 x 76 148 x 76 148 x 76 154 x 84 212 x 156
Device depth (in mm) 36 (with mounting max. 44 ) 27 27 27 42
Installation cutout (W x H in mm) 82 x 69,5 138 x 68 138 x 68 138 x 68 198 x 142 Technical specifications
Number of PowerTags
Number of ArchiveTags
Number of messages
Number of online languages
128 / 512 / 2048
100
4.000
16
Certification CE, cULus, ATEX, C-Tick, FM CE, cULus, ATEX, C-Tick, FM CE, cULus, ATEX, C-Tick, FM in prep.: FM, cULus, CE,
C-Tick, shipbuilding
in prep.: FM, cULus, CE, C-Tick,
Ex-Zone 2/22, shipbuilding
Power supply DC 24V (from S7-200) DC 24V DC 24V DC 24V DC 24V
Rated current 25 mA typ. 120 mA 120 mA 100 mA 240 mA
Ambient conditions Openness Customized solutions are
available based on ActiveX
control routines (OPP)
Zugriff auf Runtime-Display-
Objekte mit VB-Scripts
OPC DA
Temperature during operation
Vertical installation
Max. angle of inclination
0 C to 60 C
0 C to 60 C
0 C to 60 C
0 C to 60 C
0 C to 60 C
0 C to 60 C
0 C to 50 C
0 C to 40 C
0 C to 50 C
0 C to 40 C
Temp. during transportation/storage -20 C to 70C -20 C to 70C -20 C to 70C -20 C to 70C -20 C to 60C
Weight 0.12 kg 0.19 kg 0.2 kg 0.3 kg 0.7 kg
Configuring/programming Micro/WIN V4.0 SP2 Micro/WIN V4.0 Micro/WIN 4.0 from WinCC flexible Micro from WinCC flexible Micro Further information in the Internet:
www.siemens.com/wincc-flexible
Start of delivery 2. Quarter 2005
2 3
1) MTBF backlighting (at 25C):
OP 73micro: approx. 100,000 h, TP 177 micro: approx. 50,000h
Panels PC-based visualization
Further products from the
SIMATIC HMI range for
SIMATIC controllers in the
Internet:
www.siemens.com/panels
2 3
possible
not possible
Highlights
TD 100C
LC Display, four-line
Up to 14 free configurable keys
Display and size of keys can be
configured individually
Select any user interface
TD 200
Backlit LCD, two-line
8 programmable
function keys
Display of message texts
User access to control program
Setting of inputs and outputs
TD 200C
Backlit LCD, two-line
Up to 20 free configurable keys
Display and size of keys can be
configured individually
Select any user interface
OP 73micro
3" pixel-graphics display
Message system with freely-definable
message classes
Network-capable
5 online languages incl. Asian
and Cyrillic characters
TP 177micro
Low-cost starter device for the touch
panels range
5.7" pixel-graphics display
Vertical mount option possible
(240 x 320 pixels)
Indicator light
Display of machine and
plant statuses
Message system with freely-definable
message classes and message history
Network-capable
5 online languages incl. Asian
and Cyrillic characters
N N N
Bedienen_u_Beobachten_S7_200_en_TD.fm Seite 1 Dienstag, 8. Mrz 2005 10:51 10
www.siemens.com/S7-200
Order No. 6ZB5370-1CR02-0BA2
Printed in the Federal Republic of Germany
09403/501373 KB 0305 ROT 5.0 En
Siemens AG 2005
Subject to change without prior notice
All product designations may be trademarks or product
names of Siemens AG or supplier companies whose use
by third parties for their own purposes could violate the
rights of the owners.
Siemens AG
Automation and Drives
Postfach 48 48
90327 NRNBERG
FEDERAL REPUBLIC OF GERMANY
Connection options
The SIMATIC Micro Panels can easily
be connected to the S7-200 using a
standard MPI or PROFIBUS DP cable.
In addition, multi-master communi-
cation is possible, i.e.:
Integration in networks
Connection to PPI master CPU as
well
Transmission speed
up to 187.5 kbit/s
Programming/configuring made
easy
SIMATIC STEP 7-Micro/WIN
The configuration data of the
TD 200, TD 100C and TD 200C are
stored in the S7-200 CPU. The mes-
sage texts and configuration param-
eters are generated using the STEP 7
Micro/WIN programming software.
Additional parameterization soft-
ware is not required.
For data exchange with the
TD 200, TD 100C or TD 200C, special
data areas are reserved in the CPU
of the S7-200. The TD 200, TD 100C
or TD 200C access the respective
required functions and data of the
CPU over these data areas. The com-
plete configuration is therefore
stored in the data memory of the
CPU. The customer-specific operator
interface of the TD 200C is config-
ured with the support (TD Keypad
Designer) of a Micro/WIN V4.0 wiz-
ard.
SIMATIC WinCC flexible
A separate low-cost engineering
package of WinCC flexible is offered
for configuring the OP 73micro and
TP 177micro: WinCC flexible Micro.
Of course, the Compact/Stan-
dard/Advanced versions, which per-
mit the configuration of further
operator devices from the HMI prod-
uct range right up to the PC, can be
used as well.
Simple and fast configuring via
clearly structured user interfaces,
ready-to-use graphic objects, intelli-
gent tools for graphical configura-
tion (e.g. creating links between
graphics using the drag-and-drop
feature), as well as support with
multi-language configurations.
A PC/PPI adapter cable is required for
downloading the configuration.
Connecting and configuring - simple and fast
The information provided in this brochure con-
tains descriptions or characteristics of perfor-
mance which in case of actual use do not
always apply as described or which may
change as a result of further development of
the products.
An obligation to provide the respective charac-
teristics shall only exist if expressly agreed in
the terms of contract. Availability and techni-
cal specifications are subject to change with-
out prior notice.
TD 100C and TD 200C offer the possibility of configuring the operator interface
user-specifically.
Bedienen_u_Beobachten_S7_200_en.fm Seite 2 Dienstag, 8. Mrz 2005 10:47 10

You might also like