– Thermal circuit breaker 1-, 2- or 3-pole – Power tools
– Supplementary protector for general industrial use – Industrial equipment
– Positively trip-free release – Equipment for building construction
– Snap-in mounting – Medical equipment
– Version with illuminated rocker – Cleaning equipment
– Different rocker colours – Power generators
– Antibacterial cover IP65 CZM25 – Commercial and household kitchen appliances
– «Dead-Man»-version (Momentary switch)
Weblinks
Standards Approvals: http://www.schurter.com/approvals
– IEC 60934 RoHS: http://www.schurter.com/rohs
– UL 1077
– CSA C22.2 235
– GB 17701 (pending)
Technical Data
Rated voltage Ue 1-pole AC 240 V / 50/60 Hz Overload IEC 60934 min. 40 cycles @ 6 x In,
DC 32 V cos phi 0.6
2-pole AC 240 V / 50/60 Hz UL 1077 min. 50 cycles @ 1.5 x In,
DC 60 V cos phi 0.75 (OLØ)
3-pole AC 415 Y/240 V / 50/60 Hz
Admissible ambient –30 °C to +60 °C
Rated current In 1- / 2-pole 0.05 – 20 A air temperature
3-pole 0.05 – 12 A
Resistance to vibration IEC 60068-2-6, Test Tc 10…60 Hz: ±0.75 mm
Conditional short 1- / 2-pole, AC 240 V 0.05…20 A: 2000 A, SC (C1) 60…500 Hz: 10 G
circuit Inc 3-pole, AC 415 V 0.05…12 A: 2000 A
Shock resistance IEC 60068-2-27, Test Ea 30 G / 18 ms
Degree of protection Accessible range IP 40
Terminal side IP 00 Type of tripping Thermal positively trip free
2
circuit breakers
TA35
www.schurter.com/pg17_18_19
Tripping characteristics
[ min ] [ sec ] [ min ] [ sec ]
10'000 10'000
Type TA35 Type TA35
Rated current <3 A (TC-1) Rated current >3–20A (TC-1)
1, 2 pole (3 pole, max. 12A)
60 60
3 pole 1,2,3 pole
30 2`000 30 2`000
20 Ambient temp. +23 °C 20 Ambient temp. +23 C °
1`000 1`000
10 10
500 500
5 5
200 200
100 100
1 1
50 50
20 20
10 10
5 5
2 2
1 1
0,5 0,5
Tripping time
Tripping time
0,3 0,3
0,2 0,2
0,1 0,1
1,05 1,35 2 3 4 5 8 10 1,05 1,35 2 3 4 5 8 10
The above tripping characteristics apply to symmetrical overloads on all poles on the TA35 only.
At asymmetric overloads on multi-pole types, the tripping characteristic will change.
– If a 2-pole type TA35 is loaded at one pole only, the tripping current will be shifted by factor 1.05 (TC-2).
– If a 3-pole type TA35 is loaded at one pole only, the tripping current will be shifted by factor 1.10 (TC-2).
To meet the above tripping characteristic at asymmetric overloads on multi-pole types, the value of the rated current of the CBE has to be multiplied
by the factor mentioned above.
3
circuit breakers
circuit breakers
Approvals
* Approvals pending Actual information about approvals can be found on: www.schurter.com/approvals.
4
circuit breakers
TA35
www.schurter.com/pg17_18_19
Order code
Number of switched poles 1-pole 2-pole 3-pole
Number of protected poles 0 1 0 1 2 0 3
LINE
P1
LINE
P1 P1
LINE
P2 P1
LINE
P2 P1
LINE
P2 P1
LINE
P2 P3 P1
LINE
P2 P3
4 5 6
4 4 5
4 7 8 9
LOAD LOAD LOAD
7 7 8 8
LOAD LOAD LOAD LOAD
H printed white 0.1 J01 1.2 J12 5.0 050 15.0 150 *
0.2 J02 1.5 J15 6.0 060 16.0 160 *
ON
K printed black
0.3 J03 2.0 J20 7.0 070 18.0 180 *
L printed white 0.4 J04 2.5 J25 8.0 080 20.0 200 *
0
l
Other legends on request Other rated currents on request * 3-pole max. 12A
5
circuit breakers
circuit breakers
Dimensions
TA35, 1-Pole
36 17.5
+0.2
34 9.9 14.5 0
1.7
7.2
+0.3
Label
+0.2
0
33.5
7.8
44.1
34
5
LINE
7 4 P1
10.6
2.8 x 0.4 mm 21.3 12.5
2.3 Panel thickness 1.0 to 4.0 mm
(illuminated version only)
33.8 14.5
6.3 x 0.8 mm
34 20
1.7
7.2
10.3
9.8
9.7
+
+0.3
Label
44 ±0.15
+0.2
0
33.5
7.8
L
44.1
34
5
LINE
52
7 4 P1
5.7
10.6
3
23.5
2.5
13.8
6
circuit breakers
TA35
www.schurter.com/pg17_18_19
TA35, 2-Pole
36 29
+0.2
34 20.9 26 0
1.7
7.2
+0.3
Label
+0.2
33.5
0
L
44.1
34
7 4 LINE
P1
10.5
10.6
Panel thickness 1.0 to 4.0 mm
6.3 x 0.8 mm 26
32 39
24.1 27.9
+0.2
26 0
2.3
9.5
+0.3
+0.2
33.4
L 0
43.9
34
LINE
LINE
7 4 P1
10.5
10.6
7
circuit breakers
circuit breakers
32 39
29 36
+0.2
26 0
9.4
8.5
+0.3
+0.2
33.4
0
L
43.9
34
LINE
LINE
7 4 P1
10.5
10.6
11 6.1 2.3 21.3
6.3 x 0.8 mm Panel thickness
26 33.8 1.0 to 3.5 mm
+0.3
33.4
+0.2
0
L
43.9
34
LINE
LINE
7 4 P1
10.5
10.6
9.7
7.2
Label
44 ±0.15
52
+0.2
0
33.5
L
44.1
34
LINE
5.7
+0.3
7 4 P1
3
24.6
35
10.5
10.6
2.5
8
circuit breakers
TA35
www.schurter.com/pg17_18_19
TA35, 3-Pole
36 40.5
+0.2
34 31.9 37.5 0
1.7
7.2
Label
+0.2
0
34
33.5
L
44.1
7 4 LINE
P1
10.5
10.6
21.3 2.3 11 11 6.1 Panel thickness 1.0 to 4.0 mm
33.8 34.5
34 42
36 40.5
38
10.3
9.8
9.7
34 31.9
1.7
7.2
52
+0.3
+0.2
Label
0
44
34
33.5
L +0.2
38 ±0.15
37.5
44.1
0
36.1
46.5
LINE
7 4 P1 2.5
5.7
3
10.5
10.6
21.3
27.8 2.3 11 11 6.1
Panel thickness 1.0 to 4.0 mm
44 ±0.15 34.5
33.8
9
circuit breakers