POWER

Ratings

BHP
ranges

275GL (2700 - 4590)


ATGL (2508 - 4500)
APG (1390 - 4425)

VHP (366 - 2447)


VGF
(160 - 1175)
VSG (166 - 250)

Continuous

Gas Compression & Mechanical Drives


Natural Gas Fueled Engines

275GL

I.C. Water Temp. (Tcra) 130F 54C

Duty

800 rpm

900 rpm

1000 rpm

Disp.

Bore & Stroke

C.R.

bhp kWb

bhp kWb

bhp kWb

16V275GL

17,398 in3
(285 L)

10.83 x 11.81" (275 x 300 mm)

9:1

3600 2686

4050 3020

4500 3356

12V275GL

13,048 in3
(214 L)

10.83 x 11.81" (275 x 300 mm)

9:1

2700 2013

3040 2267

3375 2517

800 rpm

900 rpm

1000 rpm

2508 1871

2820 2104

3130 2335

Model

ATGL
12V-AT27GL

13,048 in3
(214 L)

10.83 x 11.81" (275 x 300 mm)

9:1

VHP
P9390GSI
P9390GL
L7044GSI
L7042GSI
L7042GL
L7042GL
L7042G
L5794GSI
L5794LT
L5774LT
L5790G
F3524GSI
F3514GSI
F3521GL
F3521G

800 rpm
3

9388 in
(154 L)

9.375 x 8.5" (238 x 216 mm)

7040 in3
(116 L)

9.375 x 8.5" (238 x 216 mm)

5788 in3
(95 L)

8.5 x 8.5" (216 x 216 mm)

3520 in3
(58 L)

9.375 x 8.5" (238 x 216 mm)

8:1
10.5:1
8:1
8:1
10.5:1
10.5:1
10:1
8.2:1
10.2:1
10.2:1
10:1
8:1
8:1
10.5:1
10:1

VGF
P48GSI/GSID
P48GL/GLD
P48GL/GLD
L36GSI/GSID
L36GL/GLD
L36GL
L36GL/GLD
H24GSI/GSID
H24GL/GLD
H24GL
H24GL/GLD
H24G
F18GSI/GSID
F18GL/GLD
F18GL
F18GL/GLD
F18G

2924 in3
(48 L)

5.98 x 6.5" (152 x 165 mm)

2193 in3
(36 L)

5.98 x 6.5 (152 x 165 mm)

1462 in3
(24 L)

5.98 x 6.5" (152 x 165 mm)

1096 in3
(18 L)

5.98 x 6.5" (152 x 165 mm)

8.6:1
11:1
11:1
8.6:1
11:1
8.7:1
11:1
8.6:1
11:1
8.7:1
11:1
11:1
8.6:1
11:1
8.7:1
11:1
11:1

VSG
F11GSI/GSID

673 in3
(11 L)

5.5 x 5.71" (127 x 145 mm)

10:1

1320
13202
11201
9871
9872

732
9201

604
5601
4931
492
366

900 rpm
1485
14852
12601
11101
11102

818
10351

672
6301
5551
554
409

984
9842
8351
7361
7362

546
6861

450
4181
3681
367
273

1000 rpm
1650
16502
14001
12331
12332
12331
896
11501
12081
1067
738
7001
6171
615
448

1107
11072
9401
8281
8302

610
7721

501
4701
4141
413
305

1200 rpm

1400 rpm

1500 rpm

7104

5304

3554

215

830
8304
9103
620
6204
620
6853
415
4154
415
4553
250
310
3104
310
3403
185

885
8854
9753
670
6704
670
7353
445
4454
445
4903
265
335
3354
335
3653
200

5304

4004

2654

160

2654 2004

160 119

620
6204
6803
460
4604
460
5103
310
3104
310
3403
186
230
2304
230
2553
138

660
6604
7303
500
5004
500
5503
330
3304
330
3653
198
250
2504
250
2753
149

1200 rpm
1980
19802
16801
14801
14802
14081
1025
13801
14501
1280
845
8401
7401
738
515

1230
12302
10441
9201
9202
9201
668
8581
9011
795
550
5221
4601
459
334

1600 rpm
945
9454
10403
710
7104
710
7803
475
4754
475
5203
285
355
3554
355
3903
215

705
7054
7753
530
5304
530
5803
355
3554
355
3903
213
265
2654
265
2903
160

1476
14762
12531
11041
11042
10501
764
10291
10811
954
630
6261
5521
550
384

1800 rpm
1065
10654
11753
800
8004
800
8803
530
5304
530
5853
320
400
4004
400
4403
240

800
8004
8803
600
6004
600
6603
400
4004
400
4403
239
300
3004
300
3303
179

1200 rpm

1400 rpm

1500 rpm

1600 rpm

1800 rpm

166 124

194 145

208 155

222 165

250 186

1 Engine available with Low Fuel Pressure System (LFPS) with the same ratings. Refer to Technical Data for LFPS ambient and altitude adjustments.
2 Engine ratings are 700-1000 rpm for low speed turbocharger operation and 1000-1200 rpm for high speed turbocharger operation.
3 These power ratings require pricebook option Code 1100 (176 BMEP) and DSM. They are available continuously when applied per WKI Power and Timing Curve S7079-19. It is permissible to operate at up to 5% overload for
two hours in each 24 hour period.
4 Inline engine ratings are 1200 - 1400 rpm for low speed turbocharger operation and 1400 - 1800 rpm for high speed turbocharger operation.Vee engine ratings are 1100 - 1600 rpm for low speed turbocharger operation and
1400 - 1800 rpm for high speed turbocharger operation.
Notes:
10% overload allowed for two hours in every 24 hour period for L7044GSI, L5794GSI, F3524GSI and F3514GSI engine models.
Ratings for lower intercooler water temperature available upon requestcontact Application Engineering.
ISO Standard Power (Continuous Power Rating): The highest load and speed which can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance. It is permissible to operate the
engine at up to 10% overload or the maximum load indicated by the intermittent rating, whichever is lower, for two hours in every 24 hour period.

Mechanical Drives

Intermittent

Natural Gas Fueled Engines

275GL

Duty

I.C. Water Temp. (Tcra) 130F 54C

800 rpm

900 rpm

1000 rpm

Disp.

Bore & Stroke

C.R.

bhp kWb

bhp kWb

bhp kWb

16V275GL

17,398 in3
(285 L)

10.83 x 11.81" (275 x 300 mm)

9:1

4130 3080

4590 3423

12V275GL

13,048 in3
(214 L)

10.83 x 11.81" (275 x 300 mm)

9:1

3102 2314

3443 2569

800 rpm

900 rpm

1000 rpm

3102 2314

3443 2569

Model

ATGL
12V-AT27GL

13,048 in3
(214 L)

10.83 x 11.81" (275 x 300 mm)

9:1

VHP
P9390GSI
P9390GL
L7044GSI
L7042GSI
L7042GL
L7042GL
L7042G
L5794GSI
L5794LT
L5790G
F3524GSI
F3514GSI
F3521G

800 rpm
3

9388 in
(154 L)

9.375 x 8.5" (238 x 216 mm)

7040 in3
(116 L)

9.375 x 8.5" (238 x 216 mm)

5788 in3
(95 L)

8.5 x 8.5" (216 x 216 mm)

3520 in3
(58 L)

9.375 x 8.5" (238 x 216 mm)

VGF
P48GSI/GSID
P48GL/GLD
L36GSI/GSID
L36GL/GLD
L36GL
H24GSI/GSID
H24GL/GLD
H24GL
H24G
F18GSI/GSID
F18GL/GLD
F18GL
F18G

2924 in
(48 L)

5.98 x 6.5" (152 x 165 mm)

2193 in3
(36 L)

5.98 x 6.5 (152 x 165 mm)

1462 in3
(24 L)

5.98 x 6.5" (152 x 165 mm)

1096 in3
(18 L)

5.98 x 6.5" (152 x 165 mm)

8.6:1
11:1
8.6:1
11:1
8.7:1
8.6:1
11:1
8.7:1
11:1
8.6:1
11:1
8.7:1
11:1

VSG
F11GSI/GSID

673 in3
(11 L)

5.5 x 5.71" (127 x 145 mm)

1631
14452
1120
12231
10842

824
9201

678
5601
4951
412

8:1
10.5:1
8:1
8:1
10.5:1
10.5:1
10:1
8.2:1
10.2:1
10:1
8:1
8:1
10:1

10:1

900 rpm
1835
16262
1260
13761
12192

920
10351

756
6301
5551
460

1216
10782
836
9121
8082

614
6861

506
4181
3671
307

1000 rpm
2039
18062
1400
15281
13552
13551
1008
11501
13151
830
7001
6151
504

1368
12132
940
10261
9092

686
7721

564
4701
4131
343

1200 rpm

1400 rpm

1500 rpm

7854

5854

3954

240

910
9104
685
6854
685
455
4554
455
275
340
3404
340
205

975
9754
735
7354
735
490
4904
490
295
365
3654
365
220

5854

4404

2904

180

2954 2204
180 130

680
6804
510
5104
510
340
3404
340
205
255
2554
255
155

730
7304
550
5504
550
365
3654
365
220
275
2754
275
165

1200 rpm
2447
21672
1680
18341
16262
14081
1152
13801
15801
946
8401
7401
576

1520
13472
1044
11391
10102
10101
752
8581
9811
619
5221
4591
376

1600 rpm
1040
10404
780
7804
780
520
5204
520
315
390
3904
390
240

775
7754
580
5804
580
390
3904
390
235
290
2904
290
180

1825
16162
1253
13681
12132
10501
859
10291
11781
705
6271
5501
430

1800 rpm
1175
11754
880
8804
880
585
5854
585
355
440
4404
440
265

880
8804
660
6604
660
440
4404
440
265
330
3304
330
195

1200 rpm

1400 rpm

1500 rpm

1600 rpm

1800 rpm

166 124

194 145

208 155

222 165

250

186

1 Engine available with Low Fuel Pressure System (LFPS) with the same ratings. Refer to Technical Data for LFPS ambient and altitude adjustments.
2 Engine ratings are 700-1000 rpm for low speed turbocharger operation and 1000-1200 rpm for high speed turbocharger operation.
4 Inline engine ratings are 1200 - 1400 rpm for low speed turbocharger operation and 1400 - 1800 rpm for high speed turbocharger operation.Vee engine ratings are 1100 - 1600 rpm for low speed turbocharger operation and
1400 - 1800 rpm for high speed turbocharger operation.
Note: Ratings for lower intercooler water temperature available upon requestcontact Application Engineering.
Intermittent Power Rating: The highest load and speed that can be applied in variable speed mechanical system applications only. Operation at this rating is limited to a maximum of 3500 hours per year.

Power Generation
Natural Gas Fueled Engine & Enginator
Remote Radiator Cooling (kWe)
I.C. Water Temp. (Tcra)
130F 54C

ATGL
16V-AT27GL
12V-AT27GL

Engines Only (kWb)

60Hz

50Hz

Continuous

Peak Shave*

Standby

Continuous

Standby

900 rpm

900 rpm

900 rpm

1000 rpm

1000 rpm

50Hz
Continuous

900 rpm

1000 rpm

3110
2104

33565
2335

Model

1800 rpm

1500 rpm

16V150LTD

11427

10387

1200 rpm

1000 rpm

1469
1469
1253
12531
1102
11021
1102
764
1078
10781
1029
10291
628
627
6271
382

1224
1224
11537
11531,7
919
9191
919
668
9477
9471,7
9477
9471,7
550
5737
5731,7
340

1800 rpm

1500 rpm

2960
2140

2960
2200

3250
2220

3250
2440

1200 rpm

1500 rpm

28007
18607

32007
21007

1800 rpm

1500 rpm

11007

10007

1200 rpm

1200 rpm

1200 rpm

1000 rpm

1000 rpm

1400
1400
1200
12001
1050
10501
1050
725
1025
10251
980
9801
595
600
6001
360

1500
1490
1200
12001
1180
11801
1100
725
1025
10251
980
9801
595
600
6001
360

1750
1540
1200
12001
1300
13001
1155
810
1025
10251
980
9801
665
600
6001
400

1175
1175
11007
11001,7
875
8751
875
635
9007
9001,7
9007
9001,7
475
5407
5401,7
315

1450
1295
1100
11001
1075
10751
965
710
900
9001
900
9001
525
540
5401
350

1800 rpm

1800 rpm

1500 rpm

1500 rpm

2960
2000

Model

60Hz
Continuous

16V-AT27GL
12V-AT27GL

I.C. Water Temp. (Tcra) 113F 45C

APG
APG3000
APG2000

I.C. Water Temp. (Tcra) 130F 54C

APG1000

I.C. Water Temp. (Tcra) 130F 54C

VHP
VHP9500GSI
VHP9500GL
VHP7104GSI
VHP7104GSID
VHP7100GSI
VHP7100GSID
VHP7100GL/GLD
VHP7100G
VHP5904LT
VHP5904LTD
VHP5904GSI
VHP5904GSID
VHP5900G
VHP3604GSI
VHP3604GSID
VHP3600G

Model
P9390GSI
P9390GL
L7044GSI
L7044GSI
L7042GSI
L7042GSI
L7042GL
L7042G
L5794LT
L5794LT
L5794GSI
L5794GSI
L5790G
F3524GSI
F3524GSI
F3521G

I.C. Water Temp. (Tcra) 130F 54C

VGF
VGF48GL
VGF48GLD
VGF48GSI/GSID
VGF36GL
VGF36GLD
VGF36GSI/GSID
VGF24GL
VGF24GLD
VGF24GSI/GSID
VGF18GL
VGF18GLD
VGF18GSI/GSID

1800 rpm
830

3
3

830

860

685

830
750
6203,9
6203
560
4153,9
4153
375
3103,9
3103
280

860
825
6459
645
620
4259
425
410
3159
315
310

1800 rpm

1800 rpm

1800 rpm

1500 rpm

1500 rpm

165

165

175

140

150

830
750
6203,9
6203
560
4153,9
4153
375
3103,9
3103
280

685
625
5153,9
5153
475
3403,9
3403
310
2503,9
2503
230

715
715
685
5359
535
515
3559
355
340
2609
260
255

Model
P48GL
P48GLD
P48GSI/GSID
L36GL
L36GLD
L36GSI/GSID
H24GL
H24GLD
H24GSI/GSID
F18GL
F18GLD
F18GSI/GSID

7303

7303
660
5503,9
5503
500
3653,9
3653
330
2753,9
2753
250

880

880
800
6603,9
6603
600
4403,9
4403
400
3303,9
3303
300

I.C. Water Temp. (Tcra) 130F 54C

VSG
VSG11GSI/GSID

Model
F11GSI/GSID

1800 rpm

1500 rpm

186

155

Heat Exchanger Cooling

Radiator Cooling

60Hz

UNIT MOUNTED
60Hz
I.C. Water Temp. (Tcra)
130F 54C

Continuous
(kWe)

I.C. Water Temp. (Tcra)


90F 32C

50Hz
Standby
(kWe)

Continuous
(kWe)

Standby
(kWe)

1200 rpm

1200 rpm

1000 rpm

1000 rpm

VHP7104GSI/GSID

11501

11501

10501,7

10501

VHP7100GSI/GSID

10001

12601

8401,7

10501

VHP7100GL

1025

1130

845

930

VHP5904LT

990

990

8607

860

VHP5904LTD

990

990

8601,7

8601

VHP5904GSI/GSID

9401

9401

8601,7

8601

VHP

ATGL

50Hz

Continuous
(kWe)

Standby
(kWe)

900 rpm

900 rpm

Continuous
(kWe)

Standby
(kWe)

1000 rpm 1000 rpm

16V-AT27GL

2960

3100

32505

3430

12V-AT27GL

2100

2310

2340

2570

I.C. Water Temp. (Tcra) 113F 45C

APG

1200 rpm

1500 rpm

APG3000

28007

32007

APG2000

18607

21007

VHP7100G

700

785

610

685

VHP3604GSI/GSID

5601

5601

5001,7

5001

VHP5900G

575

645

455

505

VHP3600G

345

385

300

335

VGF

1800 rpm

1800 rpm

1500 rpm

1500 rpm

VGF48GL/GLD

8103

825

6703

700

VHP9500GSI

1475

1825

1225

VGF48GSID

730

800

610

650

VHP9500GL

1475

1625

1225

1350

5903,9

6259

5003,9

5259

VHP7104GSI/GSID

12001,8

12001,8

11001,7,8

11001,8

11001

13501

9201

11251

VGF36GL/GLD
VGF36GSID
VGF24GL/GLD
VGF24GSID
VGF18GL/GLD
VGF18GSID

VSG
VSG11GSI/GSID

I.C. Water Temp. (Tcra) 130F 54C

1800 rpm
APG1000

11007

I.C. Water Temp. (Tcra) 85F 29C

1200 rpm

VHP

1500 rpm
10007

1200 rpm 1000 rpm 1000 rpm


1520

530

600

450

490

VHP7100GSI/GSID

3903,9

4059

3253,9

3509

VHP7100GL

1100

1210

920

1015

350

395

295

325

VHP5904LT

10258

10258

9007,8

9008

10251,7,8

10251,8

9001,7,8

9001,8

9801,8

9801,8

9001,7,8

9001,8

725

810

635

710

6001,8

6001,8

5401,7,8

5401,8

VHP5900G

595

665

475

525

VHP3600G

360

400

315

350

3,9

295

265

300

300

240

3,9

220

250

VHP5904LTD

240

VHP5904GSI/GSID

1800 rpm

1800 rpm

1500 rpm

1500 rpm

150

160

125

145

For Power Unit ratings, please contact Dresser Waukesha Application Engineering or refer to the
Waukesha Price Book.

VHP7100G
VHP3604GSI/GSID

I.C. Water Temp. (Tcra) 130F 54C

VGF

1800 rpm 1800 rpm 1500 rpm 1500 rpm

VGF48GL/GLD

8303

860

6853

VGF48GSID

750

825

625

685

6153,9

6459

5153,9

5359

VGF36GL/GLD
VGF36GSID
VGF24GL/GLD
VGF24GSID
VGF18GL/GLD
VGF18GSID

720

560

620

475

515

4153,9

4259

3403,9

3609

375

410

310

345

3103,9

3159

2503,9

2609

280

310

230

255

I.C. Water Temp. (Tcra) 85F 29C

VSG
VSG11GSI/GSID

1800 rpm 1800 rpm 1500 rpm 1500 rpm


165

175

140

150

1 Engine available with Low Fuel Pressure System (LFPS) with the same ratings. Refer to page 15 for LFPS ambient and altitude adjustments.
3 These power ratings require pricebook option Code 1100 (176 BMEP) and DSM. They are available continuously when applied per WKI Power and Timing Curve S7079-19. It is permissible to operate at up to 5% overload for two
hours in each 24 hour period.
4 Inline engine ratings are 1200 - 1400 rpm for low speed turbocharger operation and 1400 - 1800 rpm for high speed turbocharger operation.Vee engine ratings are 1100 - 1600 rpm for low speed turbocharger operation and 1400 1800 rpm for high speed turbocharger operation.
5 10% overload not available.
7 No overload allowed.
8 130F (54C) I.C. Water Temp. (Tcra)
9 Rating is for high compression ratio pistons only.
Generator Standby Power Rating (kWe): This rating applies to those systems used as a secondary source of electrical power. This rating is the output the system will produce continuously (no overload), 24 hours
per day for the duration of the prime power source outage.
*Peak Shave: These ratings are based on 3400 hours per year at ISO Standard reference conditions. Peak shaving and standby ratings may reduce lifecycle intervals.
NOTE: kWe output is based on 0.8 Power Factor Enginator efficiency.

Continuous

Alternative Fuels

Duty

Bio-Gas
Landfill
Digester
APG
Model
16V150LTD

1500 rpm

I.C. Water Temp. (Tcra) 130F 54C

Disp.

Bore & Stroke

C.R.

bhp

kWb

kWe*

bhp

kWb

kWe*

2924 in3
(48 L)

5.98 x 6.5" (152 x 165 mm)

10/14:1

1390

1038

1000

1530

1142

1100

VHP
Model
P9390GL
L7042GL
L7042GL
L5794LT

1000 rpm
Disp.
9388 in3
(154 L)
7040 in3
(116 L)
7040 in3
(116 L)
5788 in3
(95 L)

P48GLD
L36GLD
H24GLD
F18GLD

C.R.

bhp

kWb

kWe*

bhp

kWb

kWe*

9.375 x 8.5" (238 x 216 mm)

10.5:1

1642

1224

1163

1970

1469

1400

9.375 x 8.5" (238 x 216 mm)

10.5:1

12701,7

9471,7

9001,7

14081

10501

10001

9.375 x 8.5" (238 x 216 mm)

10.5:1

12706

9476

9006

1478

1102

10501

8.5 x 8.5" (216 x 216 mm)

10.2:1

12701,7

9471,7

9001,7

14451

10781

10251

1500 rpm
Disp.

1800 rpm

C.R.

bhp

kWb

5.98 x 6.5" (152 x 165 mm)

11:1

11

885

11

660

625

5.98 x 6.5" (152 x 165 mm)

11:1

67011

50011

5.98 x 6.5" (152 x 165 mm)

11:1

44511

5.98 x 6.5" (152 x 165 mm)

11:1

33511

Bore & Stroke

2924 in3
(48 L)
2193 in3
(36 L)
1462 in3
(24 L)
1096 in3
(18 L)

VSG
Model

1200 rpm

Bore & Stroke

VGF
Model

1800 rpm

Bore & Stroke

C.R.

11

11

kWb

kWe*

1060

800

11

75011

47511

80011

60011

56011

33011

31011

53011

40011

37511

25011

23011

40011

30011

28011

1200 rpm
Disp.

bhp

kWe*

1500 rpm

1800 rpm

bhp

kWb

kWe*

bhp

kWb

kWe*

bhp

kWb

kWe*

166

124

115

208

155

144

250

186

165

F11GSID

673 in
(11 L)

5.5 x 5.71" (127 x 145 mm)

10:1

1 Engine available with Low Fuel Pressure System (LFPS) with the same ratings. Refer to page 15 for LFPS ambient and altitude adjustments.
6 5% overload allowed.
7 No overload allowed.
11 Engine operation using 400 - 500 Btu/ft3 (15.7 - 19.7 MJ/m3). Landfill fuel requires 175F (80C) ICW.
NOTES:
Low Btu (calorific value) fueled engines operate on fuel with 400 Btu/ft3 (15.7 MJ//m3) or greater saturated low heat (net calorific value) and are equipped with special low Btu (calorific
value) fuel system.
VGF GLD - Gas lean combustion with draw-thru carburetion. Minimum regulated gas supply pressure is 8 H2O (12.44 mbar)
For complete information regarding operation on Low Btu Fuel, see the S3955 series (latest version) Technical Data Sheets. See Price Book for proper hardware requirements.
For low Btu Intermittent Duty application ratings, consult Waukesha Application Engineering.
Generator efficiencies are typical values. Please consult with your packager.
* kWe ratings are based on Waukesha Power Systems generator efficiencies.

10:1 Compression and 14:1 Expansion utilizing Miller Cycle Technology

Continuous

HD-5 Propane Fueled Engines


VHP
Model
P9390GSI
P9390GL
L7044GSI
L7042GSI
L7042GL
L5794GSI
F3524GSI

900 rpm

1000 rpm

1200 rpm

C.R.

bhp kWb

bhp kWb

bhp kWb

8:1
10.5:1
8:1
8:1
10.5:1

1162
1184
864
871
888

1244
1315
960
933
987

1379
1578
1152
1035
1184

I.C. Water Temp. (Tcra) 130F 54C

Disp.

Bore & Stroke

9388 in3
(154 L)

9.375 x 8.5" (238 x 216 mm)

7040 in3
(116 L)

9.375 x 8.5" (238 x 216 mm)

5788 in3
(95 L)
3520 in3
(58 L)

867
883
644
650
662

928
981
716
696
736

1029
1177
859
772
883

8.5 x 8.5" (216 x 216 mm)

8.2:1

789 588

877 654

1052 785

9.375 x 8.5" (238 x 216 mm)

8:1

472 352

524 391

629 469

VGF
P48GSID
P48GL/GLD
L36GSID
L36GL/GLD
L36GL
H24GSID
H24GL/GLD
H24GL
F18GSID
F18GL/GLD
F18GL

Duty

2924 in
(48 L)

5.98 x 6.5" (152 x 165 mm)

2193 in3
(36 L)

5.98 x 6.5 (152 x 165 mm)

1462 in3
(24 L)

5.98 x 6.5" (152 x 165 mm)

1096 in3
(18 L)

5.98 x 6.5" (152 x 165 mm)

8.7:1
11:1
8.7:1
11:1
8.7:1
8.7:1
11:1
8.7:1
8.7:1
11:1
8.7:1

VSG

1500 rpm

1800 rpm

609
496
457
376
67019
305
248
44519
228
188
33519

731
604
548
442
80019
366
302
53019
274
221
40019

454
370
341
280
50019
197
185
33019
170
140
25019

545
450
409
330
60019
273
225
40019
204
165
30019

1200 rpm

1500 rpm

1800 rpm

102

127 95

153

F11GSI

673 in
(11 L)

5.5 x 5.71" (127 x 145 mm)

10:1

76

114

19 Contact Application Engineering regarding stability in Power Generation applications


NOTES:
These engines have HD-5 propane as a secondary fuel option: VHPGL Series, VHPGSI Series, VSGGSI Series.
No overload allowed on all HD-5 propane ratings.

NOTES:

Rating Standard: All models: Ratings conform to ISO 3046/1 (latest version) with a mechanical efficiency of 90% and auxiliary water temperature, Tcra, as specified in the Power Rating Chart,
Bulletin 1079 (latest version) limited to 10 F (5.5 C). Ratings are also valid for SAE J1349, BS 5514, DIN 6271 and API 7B-11C standard atmospheric reference conditions.
Fuel Standard: All natural gas engine ratings are based on 900 BTU/ft3 (35.38 MJ/m3 [25, V(0; 101.325)]) SLHV, 91 WKI minimum, commercial quality natural gas. Refer to S-7884-7 (latest
version) for full gaseous fuel specifications.
ISO Standard Power (Continuous Power Rating): The highest load and speed that can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance
at ISO standard ambient reference conditions. At ISO standard ambient reference conditions, it is permissible to operate the engine at up to 110% of the ISO Standard Power or the maximum
power indicated by the intermittent rating, whichever is lower, for two hours in every 24 hour period.
ISO Service Power (Site Continuous Power Rating): The highest load and speed that can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance at the operating and ambient conditions of the site application. Unless otherwise stated, it is permissible to operate the engine at up to 110% of the ISO Service Power (see the Overload
Power definition) or the intermittent power rating available at the site operating and ambient conditions, whichever is lower, for two hours in every 24 hour period.
Overload Power: The power that an engine is permitted to supply, with a duration and frequency of use depending upon the service application, at stated ambient conditions, immediately after
operating at its ISO Service Power rating. Unless otherwise stated, it is permissible to operate the engine at up to 110% of the ISO Service Power or the intermittent power rating available at
the site operating and ambient conditions, whichever is lower, for two hours in every 24 hour period. For situations without a defined intermittent power, the allowable 10% overload power is
reduced from ISO standard ambient reference conditions by the applicable rating adjustments listed in the Intermittent/Standby Power column.
Intermittent Power Rating: The highest load and speed that can be applied in variable speed mechanical system applications only. Operation at this rating is limited to a maximum of 3500
hours per year.
Generator Continuous Power Rating (kWe): The highest load and speed which can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance.
Unless otherwise stated, it is permissible to operate the engine at up to 110% of the generator continuous power rating for two hours in every 24 hour period.
Generator Standby Power Rating (kWe): This rating applies to those systems used as a secondary source of electrical power. This rating is the output the system will produce continuously 24
hours per day for the duration of the prime power source outage. No overload is allowed. This rating may reduce the lifecycle intervals.
Generator Peak Shaving Application Rating (kWe) For VHP Models Only: This rating is based on the number of horsepower-hours available per year in a constant speed application at
site conditions. This rating allows for limited engine operation above the published ISO Standard Power rating for VHP models only. This rating class requires a Special Application Approval.
Contact Waukeshas Sales Engineering Department. This rating may reduce the lifecycle intervals.

Product Designations
Engine Series
Waukesha manufactures six engine families the 275GL, ATGL, APG, VHP, VGF, and VSG.
Prefix Designations
The prefix attached to an engine model indicates the number of cylinders (except 275GL, ATGL and APG which states actual number):
P = 16, L = 12, H = 8, F = 6.
VHP L7042GL engine is a 12 cylinder engine
VGF P48 GL is a 16 cylinder engine
16V275GL is a 16 cylinder engine
examples:
Numeric Designations
275GL
The numeric designation in each engine model name indicates the displacement of the
engine model in either English units of cubic inches or metric units of liters.
275 millimeter bore
The 275GL series is designated by a numeric indicator of the bore size in millimeters.
16V275GL
For example: the 275 of the 16V275GL indicates a 275 millimeter bore.
16 Cyl. Turbocharged,
The ATGL series is designated by a numeric indicator of the bore size in millimeters.
intercooled, lean burn
For example: the 27 of the 16V-AT27GL indicates a 275 millimeter bore.

The APG series is designated by a numeric indicator of the bore size in millimeters.
ATGL
For example: the 150 of the 16V150LTD indicates a 152 millimeter bore.
275 millimeter bore
The VHP series show a displacement in cubic inches. For example: the VHP L7042GL
3
indicates a displacement of 7,040 in .
16V-AT27GL
16 Cyl. Turbocharged,
The VGF and VSG series show a displacement in liters. For example: the VGF P48GL
intercooled, lean burn
indicates a displacement of 48 liters.
The VSG F11GSI indicates a displacement of 11 liters.

APG

Suffix Designations
G = Naturally aspirated
GSI = Turbocharged, intercooled
GSID = Turbocharged, intercooled, draw-through
LT = Lean combustion turbulence
LTD = Lean combustion turbulence, draw-through
GL = Turbocharged, intercooled, lean burn
GLD = Turbocharged, intercooled, lean burn, draw-through

16 Cyl.

Other Waukesha Engine Products

12 Cyl.

Dresser Waukesha Enginator Series


The Enginator is a Dresser Waukesha registered trademark of an engine generator set
packaged by Waukesha. Dresser Waukesha also designs and assembles
Engomatic panels (switchgear control systems).
Custom Engine Controls (CEC) Series
AFM = Air/Fuel Module
DSM = Detonation Sensing Module
IM = Ignition Module
TCM = Turbocharger Control Module
KDM = Knock Detection Module
Waukesha ESM
ESM = Engine System Manager
AFR = Air/Fuel Ratio Controller

152 millimeter bore

16V150LTD
Lean turbulent
combustion, draw-thru

VHP

7,040 in3 displacement

L7042GL
Turbocharged,
intercooled, lean burn

VGF

48 liters displacement

P48GLD
16 Cyl. Turbocharged, intercooled
lean burn, draw-thru

VSG
11 liters displacement

F11GSI
6 Cyl. Turbocharged,
intercooled, rich burn

Dresser Waukesha
1101 West St. Paul Avenue Waukesha, WI 53188-4999
Phone: (262) 547-3311 Fax: (262) 549-2795
2009 Dresser Inc. Waukesha, Dresser, 275GL, ATGL, APG, ESM, VHP, VGF, Series Four, Enginator, WKI,
and ESM are trademarks/registered trademarks of Dresser Waukesha, Dresser, Inc.
Bulletin 1079 0309

www.dresser.com