DESIGN OF SOLAR PUMPING SYSTEM

GIVEN DATA:

NAME: Solar Pumping System


LOCATION: Leyte Province

TABULATION DATA OF WATER REQUIREMENT:

WATER
AMOUNT
REQUIREME
PARTICULARS POPULATION REQUIRED
NT(Liters/da
(cu.m./day)
y)
Residents 75.00 6.00 0.45
Poultry 0.10 100.00 0.01
Swine 20.00 2.00 0.04
Cattle 40.00 1.00 0.04
Sheep/Goat 10.00 2.00 0.02
TOTAL AMOUNT OF WATER REQUESTED: V 0.56

Suction Head: 3.00 m.


Discharge Head: 45.00 m.
TOTAL DYNAMIC HEAD 48.00 m.

Pump Efficiency: % 0.65


Motor Efficiency: % 0.70
Pump Power requirement, KWh/day 0.16 Kwh/day

Margin Factor for future miss-much, M 1.25


Battery charge-discharge efficiency, K3 0.83
Energy transmission Efficiency, K4 0.87
Efficiency of controller/Inverter,K5 1.00

POWER DEMAND, Pd: 0.28 Kwh/day

PV CALCULATION METHOD: PV SYSTEM SIZING NOMOGRAM

Sub-system Average Daily Energy Efficiency: 40%


Conversion Efficiency: PV Panel 12.30%
Rated Output: Wp 60.00 Wattpanel
Panel Area: 0.40 sq.m.

Irradiation Design Month, Rm 3.59 KWh/sq.m./day


In the month of: ……. December
Degradation Factor (temperature), K1 0.84
Degradation of PV Power output due to contamination, K2 0.90
Miscelanneous factor, K3 0.90

SOLAR CAPACITY:

Calculated PV Array Capacity:Generated Power, Pu 0.30 Kwh/sq.m.-day


Required PV array area, S 0.93 sq.m.
Calculated Number of PV Module: 2.32 Panels
Say 3.00 Panels
Required PV Capacity, C (KW) 0.14 Kw
Say 0.18 Kw
Kwh/day

Kwh/day

Wattpanel

KWh/sq.m./day

Kwh/sq.m.-day
Solar Irradiation Data:

Location: Leyte Lattitude: 11º Array Tilt: 11º


Longitude: 124.75º

Extra Global Global


Terestial Clearness Horizontal Tilt Irradiation
Month
Irradiation, Index Irradiation, Factor Array,
(MJ/sq.m.) MJ/sq.m. kW/sq.m./day

January 31.40 0.50 15.70 1.06 4.63


February 33.60 0.50 16.80 1.03 4.81
March 36.80 0.60 22.08 1.00 6.13
April 38.00 0.40 15.20 0.99 4.18
May 37.20 0.50 18.60 0.92 4.73
June 37.20 0.50 18.60 0.89 4.62
July 37.20 0.50 18.60 0.91 4.68
August 37.20 0.40 14.88 0.95 3.91
September 36.80 0.40 14.72 0.98 4.00
October 34.60 0.50 17.30 1.02 4.90
November 31.60 0.40 12.64 1.04 3.66
December 30.40 0.40 12.16 1.06 3.59
CALCULATION OF BATTERY BANK
Power Demand, Pd: 0.28 Kwh/day
Number of Days no sunny days, retention, D: 5.00 days
Battery Maintenance Factor, Km: 0.95
Efficiency of Controller, K5 0.90
Battery Voltage, Vb 12.00 Volts
Temperature Multiplier,Tm 1.04
Depth of Discharge,Kb 0.80

Battery Capacity, Bc: 176.55 Ampere-Hour

Choose Battery Capacities: 40,60,80,112,120, 136,140,160,176 Ah

Use Battery Capacity: 112 Ah

Number of Cells: 1.58 Units


Say 2.00 Units 12 Volts Connected in Parallel
d in Parallel