LV 430390

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

T

h
e

i
n
f
o
r
m
a
t
i
o
n

p
r
o
v
i
d
e
d

i
n

t
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

c
o
n
t
a
i
n
s

g
e
n
e
r
a
l

d
e
s
c
r
i
p
t
i
o
n
s

a
n
d
/
o
r

t
e
c
h
n
i
c
a
l

c
h
a
r
a
c
t
e
r
i
s
t
i
c
s

o
f

t
h
e

p
e
r
f
o
r
m
a
n
c
e

o
f

t
h
e

p
r
o
d
u
c
t
s

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
T
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

i
s

n
o
t

i
n
t
e
n
d
e
d

a
s

a

s
u
b
s
t
i
t
u
t
e

f
o
r

a
n
d

i
s

n
o
t

t
o

b
e

u
s
e
d

f
o
r

d
e
t
e
r
m
i
n
i
n
g

s
u
i
t
a
b
i
l
i
t
y

o
r

r
e
l
i
a
b
i
l
i
t
y

o
f

t
h
e
s
e

p
r
o
d
u
c
t
s

f
o
r

s
p
e
c
i
f
i
c

u
s
e
r

a
p
p
l
i
c
a
t
i
o
n
s
.
I
t

i
s

t
h
e

d
u
t
y

o
f

a
n
y

s
u
c
h

u
s
e
r

o
r

i
n
t
e
g
r
a
t
o
r

t
o

p
e
r
f
o
r
m

t
h
e

a
p
p
r
o
p
r
i
a
t
e

a
n
d

c
o
m
p
l
e
t
e

r
i
s
k

a
n
a
l
y
s
i
s
,

e
v
a
l
u
a
t
i
o
n

a
n
d

t
e
s
t
i
n
g

o
f

t
h
e

p
r
o
d
u
c
t
s

w
i
t
h

r
e
s
p
e
c
t

t
o

t
h
e

r
e
l
e
v
a
n
t

s
p
e
c
i
f
i
c

a
p
p
l
i
c
a
t
i
o
n

o
r

u
s
e

t
h
e
r
e
o
f
.
N
e
i
t
h
e
r

S
c
h
n
e
i
d
e
r

E
l
e
c
t
r
i
c

I
n
d
u
s
t
r
i
e
s

S
A
S

n
o
r

a
n
y

o
f

i
t
s

a
f
f
i
l
i
a
t
e
s

o
r

s
u
b
s
i
d
i
a
r
i
e
s

s
h
a
l
l

b
e

r
e
s
p
o
n
s
i
b
l
e

o
r

l
i
a
b
l
e

f
o
r

m
i
s
u
s
e

o
f

t
h
e

i
n
f
o
r
m
a
t
i
o
n

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
Feb 26, 2014
1
Product data sheet
Characteristics
LV430390
circuit breaker Compact NSX160B - 100 A - 3
poles - without trip unit
Main
Device short name Compact NSX160B
Circuit breaker name Compact NSX160B
Poles description 3P
Network type AC
Network frequency 50/60 Hz
[In] rated current 160 A ( 40 C )
[Ui] rated insulation
voltage
800 V conforming to IEC 60947-2 AC 50/60 Hz
[Uimp] rated impulse
withstand voltage
8 kV conforming to IEC 60947-2
[Ue] rated operational
voltage
690 V conforming to IEC 60947-2 AC 50/60 Hz
Circuit breaker rating
code
B
Breaking capacity 15 kA Icu conforming to IEC 60947-2 at 500 V AC
50/60 Hz
20 kA Icu conforming to IEC 60947-2 at 440 V AC
50/60 Hz
20 kA Icu conforming to NEMA AB1 at 480 V AC
50/60 Hz
25 kA Icu conforming to IEC 60947-2 at 380/415 V
AC 50/60 Hz
40 kA Icu conforming to IEC 60947-2 at 220/240 V
AC 50/60 Hz
40 kA Icu conforming to NEMA AB1 at 240 V AC
50/60 Hz
[Ics] rated service
breaking capacity
Ics 15 kA conforming to IEC 60947-2 500 V AC
50/60 Hz
Ics 20 kA conforming to IEC 60947-2 440 V AC
50/60 Hz
Ics 25 kA conforming to IEC 60947-2 380/415 V AC
50/60 Hz
Ics 40 kA conforming to IEC 60947-2 220/240 V AC
50/60 Hz
Suitability for isolation Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Utilisation category Category A
Pollution degree 3 conforming to IEC 60947-1
Complementary
Control type Toggle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
Mechanical durability 40000 cycles conforming to IEC 60947-2
Electrical durability 10000 cycles conforming to IEC 60947-2 440 V In/2 AC 50/60 Hz
15000 cycles conforming to IEC 60947-2 690 V In/2 AC 50/60 Hz
20000 cycles conforming to IEC 60947-2 440 V In AC 50/60 Hz
7500 cycles conforming to IEC 60947-2 690 V In AC 50/60 Hz
Connection pitch 35 mm
2
Environment
Standards EN 60947-2
IEC 60947-2
NEMA AB1
UL 508
Product certifications CSA
UL
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -35...70 C
Ambient air temperature for storage -55...85 C

You might also like