Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 9

Software Guide for SEC MP Logging v1.

1



Purpose:
Purpose of this software is to help EMSD in the manufacturing of EVM units in a sequential and
controlled manner. It stores all records about manufacturing stages for each EVM unit.

It uses the notion of facilities which is nothing but a series of predefined stages.

Manufacturing Stages:
EVM manufacturing process consists of the following stages.















Stage 1
Inward To
Facility 1
Stage 24
Packing
Stage 12
Inward
To Facility 3
Stage 11
Outward
to Facility 3
Stage 9
Potting of Critical
Components
Stage 8
Diagnostic test
post PCB (T1)

Stage 7
Inward
To Facility 2
Stage 5
PCB
Stage Inspection

Stage 4

Wave Soldering
Stage 3
SMT
Stage Inspection


Stage 2

SMT
Stage 13

Unit Assembly

Stage 14
Mechanical
Inspection
Stage 6
Outward
To Facility 2
Stage 10
Diagnostic test
post burn in (T2)

Stage 15
Outward
To Facility 4

Stage 17
Final QC
Facility 1 Facility 2
(Testing Section)
Facility 3
(Unit Assembly Section)
Facility 4

Stage 20
Configuration
Stage 16
Inward
To Facility 4

Stage 18
Outward
To Facility 5
Stage 23
Outward to
Packing

Stage 19
Inward
To Facility 5
Stage 21
Serial Number
Loading and
Laser Marking
Stage 22
Serial Number
Check
Facility 5

Facility 6
(Packing)



Installation and Working on the Software:
Check your Network Connection and display resolution. The resolution should be 1366*768.
You can check it from right click on desktop>screen resolution> click on dropdown beside
resolution:> select 1366*768> click OK.
Now simply run the SEC-MP-Logging.bat from your desktop by double clicking the icon.
The following screen will appear if your network and IP settings are configured properly.
If screen doesnt appear but instead, a message box comes. Check your network connection.
Still if you are not able to see this screen then contact software support team for further
assistance.



Fig. 1: login screen





User Login:
There are 3 types of users for this software.

1) Administrator.
2) Supervisor.
3) Data Entry User.

1) Administrator

Admin ID will start from ADM (example ADM01, ADM02).
He is the highest level of system admin for the software and can manage all users for
all facilities.
Functions of Administrator are shown in the screenshot below.



Fig.2: Admin Screen





a) Create Admin :- This link is used to create another Administrator.

b) Create Supervisor :- Using this link Administrator can create the Supervisor for any
facility.

c) Create User :- Using this link Administrator can create the Data Entry User for any
stage.

d) Disable/Enable User :- By Clicking this Administrator can Disable and Enable any
Supervisor or User.

e) Data Entry :- Using this link Administrator can perform data entry at any Stage of any
Facility.

f) Unit History :- Administrator can view the logging of previous stages for a particular
unit.

g) Reject a Unit :- Using this link Administrator can reject any unit only at stages given
below:
Stage: 3 (SMT Stage Inspection)
Stage: 5 (PCB Stage Inspection)
Stage: 8 (T1 Testing)
Stage: 10 (T2 Testing)
Stage: 14 (Mechanical Inspection)
Stage: 17 (Final QC)

h) Accept a Unit :- By using this link Administrator can accept any unit and can continue
from the next stage. He need not make an entry for the rejection stage again.

i) Manufacturing Status :- Administrator can view the Manufacturing status of a facility
and overall status also.

j) Change Password :- Administrator can change his password if he wants to.









2) Supervisor
Supervisor ID will be in the form of SP*01 where * is A or B or C according to
Facility.
He is responsible for his facility only.
Functions of Supervisor are shown in the screenshot below.



Fig. 3: Supervisor Screen



a) Reject a Unit :- Using this link Supervisor can reject any unit only for his facility.

b) Accept a Unit :- Using this link Supervisor can accept any unit only for his facility.

c) Unit History :- Supervisor can view the logging of previous stages for a particular unit
in his facility.

d) Manufacturing Status :- Supervisor can view the Manufacturing status of his facility.

e) Change Password :- Supervisor can change his password if he wants to.




3) Data Entry User

User ID will be in the form of U*#01 where * is A or B or C ...according to
Facility and # represents Facility stages(A,B,C,...).
User can enter the data according to his stage.




Fig.4: User Screen


















Rejection:-
Once the data entry is done for the rejection stage, Supervisor will select the Reject a Unit Link
then he has to enter the PCB ID or Cabinet ID.
a) In Facility-1 the rejection will take place only at Stage-3 (SMT Stage Inspection)
and Stage -5 (PCB Stage Inspection). Supervisor has to select the reasons from the drop down
before rejecting.
b) In Facility-2 the rejection will take place only at Stage-8 (T1 Testing) and Stage-10 (T2
Testing) supervisors have to select the reasons from the drop down before rejecting.
c) In Facility-3 the rejection will take place only at Stage-14 (Mechanical Stage Inspection)
supervisor has to select the reasons from the drop down before rejecting.
d) In Facility-4 the rejection will take place only at Stage-17 (FQC Testing) supervisor has to
select the reasons from the drop down before rejecting.
Acceptance:-
For Accepting a unit Supervisor will select the Accept a Unit Link then he has to enter the PCB
ID/Cabinet ID to accept the Unit in which stage it has been rejected.

Manufacturing Status:-
Facility number, Unit Type and Dates are required to see the manufacturing status. The screenshot
for manufacturing status is shown below.



Fig. 5: Manufacturing Status


Unit History:-

There are 2 types of unit History i.e. Partial Unit History and Complete Unit History.
During the production we will use Partial Unit History only.
According to the facility number History of the unit will be displayed when we click submit
or press Enter.
In Facility-3 if we give PCB ID or Display ID then details for stage: Inward to Facility-3
and stage: Unit Assembly will be displayed. If we give Cabinet ID then details for stage:
Mechanical Inspection and stage: Outward to Facility-4 will be displayed.
If a unit is rejected in some stage, it will show that also at the bottom.
The Screen below gives the history of a Display PCB ID.




Fig. 6: Unit History









Disable or Enable User/Supervisor:-

Only Admin can Disable or Enable a User or a Supervisor.
When Admin selects a user from dropdown list, its current status will be checked by default.
He can then change the radio Button if it requires.
The Screen below gives view for disabling a user.



Fig. 7: Disable or Enable a User/Supervisor





For further assistance regarding Software, Contact -
040-2718-6991
7382775302 (Mob)
akhileshs@ecil.co.in


- AKHILESH SINGH
Engineer
29-00-140767
EMSD-ECIL

You might also like