The Mechanical Insertion Assembly features a unique lead screw and clamp design permitting insertion and retraction of the sensor up to 295 psig (2036 kPa abs) and 392degF (200degC). Flush PORTS ON ASSEMBLY CHAMBER allow sensor cleaning.
The Mechanical Insertion Assembly features a unique lead screw and clamp design permitting insertion and retraction of the sensor up to 295 psig (2036 kPa abs) and 392degF (200degC). Flush PORTS ON ASSEMBLY CHAMBER allow sensor cleaning.
The Mechanical Insertion Assembly features a unique lead screw and clamp design permitting insertion and retraction of the sensor up to 295 psig (2036 kPa abs) and 392degF (200degC). Flush PORTS ON ASSEMBLY CHAMBER allow sensor cleaning.
EASY INSERTION/RETRACTION OF SENSOR up to 295 psig (2036 kPa abs) and 392F (200C). FLUSH PORTS ON ASSEMBLY CHAMBER allow sensor cleaning. FEATURES AND APPLICATIONS The Rosemount Analytical Mechanical and Manual Valve Insertion Assemblies are available for use with the Model 228 Toroidal Conductivity Sensor for processes where the measured solution tends to coat, plug, or abrade the sensor. These assemblies should be mounted in a main process line, allowing sensor isolation for cleaning or replacement without expensive bypass line piping. The Mechanical Insertion Assembly features a unique lead screw and clamp design permitting insertion and retraction of the sensor up to 295 psig (2036 kPa abs) and 392F (200C). Rugged, chemi- cally resistant 316 Stainless Steel materials of con- struction withstand the effects of many corrosive solutions. The sensor can be cleaned without removal from the assembly by using a wash solution through two flush ports in the retraction chamber. Alternatively, differ- ential high pressure flow into one of the ports exiting to the process line will establish a vortex washing action. A ball valve is not included in either assembly. SPECIFICATIONS Ordering Information: Mechanical Assembly: P/N 23311-00 Manual Assembly: P/N 23311-01 Maximum Operating Conditions: 295 psig (2036 kPa abs), 392F (200C) Maximum Insertion/Retraction Conditions: Mechanical Assembly: 295 psig (2036 kPa abs), 392F (200C) Manual Assembly: 35 psig (241 kPa abs), 266F (130C) Materials of Construction: 316 Stainless Steel, Teflon 1 , Ethylene Polypropylene Process Connections: 1-1/2 in. MNPT Recommended Valve: 1-1/2 in. full port ball valve Maximum Insertion Travel: Mechanical Assembly: 10.5 in. (26.7 cm) Manual Assembly: 12 in. (30 cm) Installation Type: Insertion/Flow through Weight/Shipping Weight: Mechanical Assembly: 12 lb/15 lb (5.4 kg/6.8 kg) Manual Assembly: 9 lb/12 lb (4.1 kg/5.5 kg) 1 Teflon is a registered trademark of E.I. du Pont de Nemours & Co. Model 228 Valve Insertion Assemblies For The Model 228 Sensor Product Data Sheet PDS 71-228/rev.B December 2003 MOUNTING & DIMENSIONAL DRAWINGS BOTH ASSEMBLIES REQUIRE EXTENSION CABLE P/N 23294-00 OR -01 (SPECIFY LENGTH) P/N 23311-01 BALL VALVE REQUIRED. TO BE SUPPLIED BY OTHERS. P/N 23311-00 BALL VALVE REQUIRED. TO BE SUPPLIED BY OTHERS. 3/4 in. FNPT COLLET NUT COLLET NUT GUARD NUT GUARD SPRING J-BOX WITH SCREW CAP 3/4 in. FNPT STOP COLLAR 3 in. HEX UNION NUT 3 in. HEX UNION NUT 2.531 in.-8 ACME THREAD (TYP) 2.531in.-8 ACME THREAD (TYP) 1/8 in. MNPT PLUG (TYP) 1/8 in. MNPT PLUG (TYP) 1-1/2 in. MNPT 1-1/2 in. MNPT 316 SS .75 in. O.D. TUBE 316 SS .75 in. O.D. TUBE TOROIDAL SENSOR MODEL 228-20-62 (NOT INCLUDED) TOROIDAL SENSOR MODEL 228-20-62 (NOT INCLUDED) 2-5/8 in. HEX RETRACTION CHAMBER 2-5/8 in. HEX RETRACTION CHAMBER 12.7 .5 184.15 7.25 146.05 5.75 676 26.63 305 12 682.75 26.88 651 25.63 30.94 1.218 266.7 10.5 19.05 .75 CAP NUT HOUSING TRAVEL STOP COLLAR A J-BOX WITH SCREW CAP LEAD SCREW TRAVEL STOP COLLAR B MILLIMETER INCH Credit Cards for U.S. Purchases Only. The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2005