Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

A

B
D
E
F
F L UI D SE NSORS | SI CK 8013856/2010-11-02
Subject to change without notice
Level sensors

B- 22
LFH
Product description
The level probe LFH is a robust pressure
transmitter for continuous level measure-
ment. The liquid column above the probe
creates a hydrostatic pressure which
is a direct indicator for the liquid level.
Through its permanently connected ca-
ble the LFH is submerged into the liquid.
The precise measurement technology
is integrated in a robust stainless steel
housing. To meet the diverse require-
ments, the level probe LFH is available
in two versions, standard and enhanced.
For the enhanced variant there is a
number ot options available that extend
the range ot applioations signitoantly
suoh as a maximum oable length ot
250 m (standard version: 100 m), an
integrated temperature measurement, a
surge protection and a connection cable
with highly resistant FEP sheathing (up
to 100 m).
At a glance
Immersion depth up to 100 m (op-
tionally up to 250 m)
Available with various cable lengths
Measuring ranges from 0 bar
0.1 bar up to 0 bar 25 bar
Stainless steel membrane
Hermetically sealed stainless steel
housing with PA protection cap
Cable made from PUR, FEP-cable for
aggressive media optionally available
Optional temperature measurement
with integrated Pt100 element
Optional surge protection
Your benets
Enables level measurement under dif-
toult oonditions where other meas-
urement technologies fail
Rugged and reliable through robust
mechanical design and high-grade
materials
For cleaning purposes the probe can
easily be taken out of the liquid
No openings required in the wall of
the vessel
At a high level
Additional information
Detailed technical data. . . . . . . . . . B-23
Ordering information. . . . . . . . . . . . B-24
Dimensional drawings . . . . . . . . . . B-24
Recommended accessories. . . . . . B-25
A
B
D
E
F
F L UI D SE NSORS | SI CK 8013856/2010-11-02
Subject to change without notice
Level sensors

B- 23
LFH
Detailed technical data
Features
Pressure units
1)
Bar, mH
2
O
Measuring ranges Standard variant: From 0 bar ... 0,25 bar up to 0 bar ... 10 bar
Enhanced variant: From 0 bar ... 0,1 bar up to 0 bar ... 25 bar
Process temperature 10 C ... +50 C
-10 C ... +85 C with lLP oable (optional tor enhanoed variant)
Output signal and maximum
ohmic load R
A
4 mA 20 mA, 2-wire, R
A
> (L
+
- 10 v) / 0.02 A - (0.14 x oable length in m) [0hm]
0 V 10 V, 3-wire optional
2)
, R
A
> 100 kOhm
0 V 5 V, 3-wire optional
2)
,

R
A
> 100 kOhm
Temperature measurement Pt100, 4-wire optional for enhanced version, I
max.
= 3 mA, I
meas.
= 1 mA
1)
1 bar = 10,2 mH
2
O (meter water column).
2)
Only with enhanced variant.
Performance
Accuracy
1)
> | 0.5 ot span with standard version and enhanoed version with p < 0.25 bar
> | 0.25 ot span with enhanoed version p < 0.25 bar
Non-linearity > | 0.2 ot span, (Best lit 3traight Line, Bl3L) aooording to lLC 61298-2
Non-repeatability > | 0.1 ot span
Long-term drift/one-year stability > | 0.2 ot span (at reterenoe oonditions)
1emperature coetcent wthn rated
temperature range
Mean 1C ot zero: > 0.2 ot span / 10 K (< 0.4 tor pressure range > 0.25 bar),
Mean 1C ot span > 0.2 ot span / 10 K
Rated temperature range 0 C ... +50 C

1)
lnoluding non-linearity, hysteresis, zero point and tull soale error (oorresponds to error ot measurement per lLC 61298-2). Adjusted in vertioal mounting position with
lower pressure connection.
Mechanics/electronics
Wetted parts Standard: stainless steel, Pressure connection/ diaphragm: stainless steel, Protection cap: PA
Cable PUR or FEP
Electrical connection Cable PUR (tensile strength 1000 N),
Cable FEP optionally available for enhanced variant (tensile strength 500 N)
Supply voltage 10 V DC ... 30 V DC
14 V DC ... 30 V DC with output signal 0 V ... 10 V (only with enhanced variant)
Electrical safety Protection class: III,
Short-circuit protection: QA towards M,
Reverse polarity protection: L+ towards M
Surge protection EN 61000-4-5 (1.5 J) optional for enhanced variant
Dielectric strength 500 V DC,
NLC Class 02 power supply (low voltage and low ourrent max. 100 vA even under tault oondi-
tions)
CE-conformity LMC direotive: 2004/108/LC, LN 61 326-2-3
Weight sensor Ca. 0.18 kg
Enhanced variant: ca. 0.20 kg
Weight cable Ca. 0.08 kg/m
Enclosure rating lP 68
Ambient data
Storage temperature -30 C ... +80 C
A
B
D
E
F
F L UI D SE NSORS | SI CK 8013856/2010-11-02
Subject to change without notice
Level sensors

B- 24
LFH
Ordering information
1he part numbers below show a seleotion ot our oommon oontgurations and represent only an extraot ot the produot porttolio.
LFH
Standard variant
Signal output: 4 mA ... 20 mA
Measuring range Cable length Model name
0 bar ... 1 bar
10 m LFH-SB1X0G1AS10SZ0 6040950
15 m LFH-SB1X0G1AS15SZ0 6040951
20 m LFH-SB1X0G1AS20SZ0 6040952
25 m LFH-SB1X0G1AS25SZ0 6040953
0 bar ... 1.6 bar
15 m LFH-SB1X6G1AS15SZ0 6040954
20 m LFH-SB1X6G1AS20SZ0 6040955
25 m LFH-SB1X6G1AS25SZ0 6040956
30 m LFH-SB1X6G1AS30SZ0 6040957
0 bar ... 0.25 bar
1.5 m LFH-SBX25G1AS01SZ0 6040938
3 m LFH-SBX25G1AS03SZ0 6040939
5 m LFH-SBX25G1AS05SZ0 6040940
10 m LFH-SBX25G1AS10SZ0 6040941
0 bar ... 0.4 bar
5 m LFH-SBX40G1AS05SZ0 6040942
10 m LFH-SBX40G1AS10SZ0 6040943
15 m LFH-SBX40G1AS15SZ0 6040944
20 m LFH-SBX40G1AS20SZ0 6040945
0 bar ... 0.6 bar
5 m LFH-SBX60G1AS05SZ0 6040946
10 m LFH-SBX60G1AS10SZ0 6040947
15 m LFH-SBX60G1AS15SZ0 6040948
20 m LFH-SBX60G1AS20SZ0 6040949
Dimensional drawings
5tandard verslen (lmmerslen deth u te 100 m)
1
8
(
0
.
7
1
)
27
( 1.06)
1
0
0
(
3
.
9
4
)
G1/2B
1
0
(
0
.
3
9
)
All dimensions in mm (inch)
nhanced verslen wlth PUR cable (lmmerslen deth u te
250 m)
27
( 1.06)
1
8
(
0
.
7
1
)
1
3
0
(
5
.
1
2
)
1
0
(
0
.
3
9
)
G1/2B
All dimensions in mm (inch)
Process temperature: 10 C ... +50 C
Electrical connection: Cable PUR
A
B
D
E
F
F L UI D SE NSORS | SI CK 8013856/2010-11-02
Subject to change without notice
Level sensors

B- 25
LFH
nhanced verslen wlth FP cable (lmmerslen deth u te
100 m)
27
( 1.06)
1
4
7
(
5
.
7
9
)
1
8
(
0
.
7
1
)
1
0
(
0
.
3
9
)
G1/2B
All dimensions in mm (inch)
Recommended accessories
Other mounting accessories, additional weight
Brief description Weight Material Model name
Additional weight for stabili-
zation of level probe LFH in
moving liquids
500 g Stainless steel 1.4571
BEF-AW-
LFHSST-0001
5324308
Plug oonneotors and oables, sensor oonneotion boxes
Brief description Enclosure rating Material Model name
For electrical connection of
level probe LFH. With inte-
grated pressure compensa-
tion and terminal block.
IP 67 Polycarbonate, grey
ASK-CB-LFH-
PC0-0001
5324310
Proteotion tlter, vent tube tlter
Brief description Model name
For level probe LFH. Prevents humidity from entering the ventilation tube of the connec-
tion cable. For self-mounting at cable end.
APR-VF-LFH001-0001 5324309
Terminal and alignment brackets, terminal brackets
Brief description Material Tensile strength Model name
Cable clamp for installation
of connection cable of level
probe LFH
Galvanized steel, plastics > 2.5 kN
BEF-CC-
LFH001-0001
5324307
For additional accessories, please see page F-1