5.2.3 Function description of main circuit terminals
SYMBOL | FUNCTION DESCRIPTION
RS.T Input terminals of AC line power.
P.Pr External braking resistor terminals.
PP, External DC reactor terminals.
P.N External Braking unit terminals.
UV.W Output terminals to motor.
E Ground terminal.
5.2.4 Function description of control circuit terminals
Symbol Functions Factory setting
FOR Multi-function inputl Forward run
REY Multi-function input2 Reverse run
RST Multi-function input3 Reset
SPH Multi-function inputd High speed
SPM Multi-function inputS Medium Speed
SPL Multi-function input6 Low Speed
DCM Ground common for input
terminals,
EVaPV) I2V power supply ‘Max output current 200mA
P24 +24V power supply ‘Max output current 200mA
+10 | Power supply for analog frequenay +10V
VI ‘Analog frequency reference O=+I0V corresponding to
input(voltage) highest operating frequene
Ar “Analog frequency reference 4-20mA corresponding to
input(current) highest operating frequenc
ACM | Common for analog input signal
DRY Multi-function output terminal 1 ee ee
UPF Multi-function output terminal 2
FA(EFA).
FB(EFB), | Multi-function output terminal 3 mera Pee
FC(EFC) .
Rae Multi-function output terminal 4 ADsnACanoToee
AM Digital frequency output terminal O-10V
RS+RS-
RS-485 communications
u5.3 Standard Connection Diagram
The whole wiring isdivided into two parts.Main circuit terminal
connections and control circuit terminal connections.Users can see the
main circuit terminals,and the control circuit terminals after removing
the outer cover.The terminals must be connected correctly as the
following diagrams.
The following diagram shows the standard connection of
eg hea!
‘Ae power supoly —¢ a) moe
vristov) KA Mufuncton ouput tay NO>
KB aazsovac aa0v0C
Eviy)etav
‘naiog Curent Ci
input i FC Mutfuncion ouput lay NO NIC>
1. FA sazsovac
— Fe sasovoe
Ey
-~% ORV Mutituncton ouput
aA UPR 24v/100mA,
Ly
= Analog requoney out
‘o-10v"
KA Multsuncton ouput «Relay NOS
KB aN2s0vAC. 9A/90VDC
eviry+12v
rok of Ja!
Analog Curent +
input FC Multsuncton output
FA aN2S0VAC
a FB sasovoc
Cyt
Py DAV Mult-uncton output «Relay OP>
Ly PF 2avrt00ma
Ly om
AMT] Artogrequency oust
2 ——— aDe Braking Resistor or unit
EKA Mull-unction ouput «Relay NIO>
FRB 2250VAC 3430V0C
P24 (#24v)
EFC Multtunction ouput «Relay NIO, NIC>
EFA 3As0vAC awSOVDC
FB.
RV Mut-unction output
UPR 24v/100mA
cm
Arolog Frequency output
10
5.4 Cautions on Wiring
5.4.1 For main circuit wiring
@No Fuse Breaker between the power supply and the input
terminals(R.S.T).
(If using ground fault interrupter,please choose the one corresponding
to high frequency)
@Never connect AC power to the output terminals of U.V.W on the
inverter.
@Output wires mustn’t be in touch with the metal part of the outer
cover,or it will cause short-circuit.
@Phase-shifting capacitor,LC.RC noise filters,etc,can never be
connected between motor and output terminals(U.V.W)
@The main circuit wire must be enough far away from other control
equipments.
@If there is a relatively long distance between the inverter and the
motor,please lower the carrier frequency.Because the high leak current
will cause damage to the inverter and other equipments.
@If the wire is more than 15m for 220V class products(or 30m for 380V
class products)between the inverter and the motor,please choose a AC
motor special for inverters or add a AC reactor on the output side of the
inverter ,because a very high dV/dT produced in the motor coil will
13be 100 or lower.)
380V class:Special grounding method.(earth resistance should be 100
or lower.)
@ Choose grounding wires according to the requirements of the electric
equipment.
@ Avoid sharing grounding wire with other large power equipment.The
grounding wire should be kept away from the power supply wires.
@The grounding method for several inverters together should be done
as the first and second diagrams. Avoid the third diagram.
@The shorter the Cc 4 is the better i e) is.
ey yy
(1) Correct (2) Correct (3) Wrong6. Descripition of Digital Operator
Operation Mode Indicators
forward run, reverse run,
frequency, current, Speed.
Main Displaying Area; Output
|__Voltage, Frequency, Current AC
DC Voltage, Rotation, Speed
Countion, Temperature.
Forward or reverse run key—+
Numerical change key —|
Read/Write key
|—Stop/RESET key
Operation Mode Indicators
forward run, reverse run, |
frequency, current, Speed. | _ | Main Displaying Area:Output
|__Voltage, Frequency ,Current AC
DC Voltage Rrotation Speed
Countion, Temperature.
Forward or reverse run key |— Function selection key
Numerical change key —]
{— ReadiWrite key
Run key —| UN | —}— Stop/RESET key
HLKD0001
166.2 Display status
6.2.1 Display status description
Indicator Status Explanation
FOR On Forward run
REV On Reverse run
HZ On Display set frequency or output frequency
A On Display output current
ROTT On | Display motor speed
HZ A On | Display DC voltage
A ROTT On Display output voltage
HZ ROIT On | Display counting data
HZ A ROTT | On __| Display inverter temperature
6.2.2 Explanation to data displa:
Display item | Indicator__on Explanation
050.00 HZ Present set frequency or
a output frequency
A
5.5 it Current
1440 ee Motor speed
HZ A ROTT Present inverter heat sink
30.0
n a temperature
D100 uz Function item
EOC.A Error information6.3 Operation Example
Procedures [ Data Display Explanation
Poweron | dsp.1 flashing] FOR — Hz _| Self inspection after power on,
1 uErt.3 0 | showing its version number
~000.00 (flashing),then its set frequency.
Pros | FOR H
1 D000 a a | Function number Ca00o.
0.00 FOR Hi
ate eND-50.00 | 9H | Modify the value of Function
ENTER CD00. Display:END--50.00
1 Doo} CD01 Withdraw from the
050.0} FOR — Hz_| programming status.
PROG H oo (ee a
4 Display:Forward run status and
FOR Hz
aun _| _5000 fl Ma [Set frequency.
]
‘ | s0.00 FOR —Hz_| Switching to display running
<—_ 0.00--50.00 x | frequency.
Disp
+ | FOR A_| Switching to display output
— 0005.0 # 3% | current.
DIsP
+ FOR ROTT | Switching to display rotating
a or4ao ¥ | speed.
Disp
1 ex FOR —Hz_| Returnto main display,showing
PROG # | set frequency.
4 REV Hz_| FORWARD RUN/REVERSE RUN
FR oso oe) H | shift,display “reverse run" status.
+ 050.0} REV -Hz_| Switching to frequency
A ¥ | adjustable status.
t REV —_Hz__| Adjust the set frequency, that is,
ox0.00 ju quency,