2 SITE AND UTILITY DATA
3 Number of HPU's required Location:
4 Mount type
5 Skid Overall Dimensions ( m x m x m ) Electrical class.:
6 Overall Weight (kg)
7 Hydraulic System Efficiency % Site data:
8 System Overall friction pressure drop (MPa) Altitude (m) Barometer (kPaa)
9 (Excluding pump efficiency) Ambient temperature (Min/Max) (C) /
10 Vendor provided GA Relative humidity (Min/Max) % / %
11
12 Other
13
14 Manufacturer / Model: No. Req'd MATERIAL (By Vendor)
15 Pump size: Drive: Casing Piston
16 Pump type: No. stages: Baseplate Coupling / Drive guard
17 Motor provided by: Shaft Gaskets
18 Motor mounted by: Gland Bolts
19 DESIGN DATA/OPERATING CONDITIONS
20 Capacity: (l/s)
21 Normal Rated Other
22 Suction pres.(kPag) Max Rated AUXILIARY PIPING (By Vendor)
23 Disch pres:(kPag) Diff. Pres. (kPa) Cooling air
24 Differential head (m) NPSHA (m)
25 Service, Remarks:
26 Oper. Schedule: (h/day) Days/Year
27 No. of Starts: per Hour per Day
28 Oil Type
29 Pumping temperature (C) (Norm/Max/Min)
30 Vapour pressure (kPaa) @ (C)
31 Specific Gravity (Norm/Max/Min) MOTOR DRIVE (By Vendor)
32 Viscosity (cP) (Norm/Max) @ C Manufacturer
33 PERFORMANCE (By Vendor) Type
34 Curve No. RPM Model Number
35 Rated power (kW) Efficiency: Rated output (kW) Speed (rpm)
36 Minimum continuous flow: (l/min) Frame Mount
37 Max Head rated (m) Max disch pres (kPag) Service factor NEMA Design
38 Pressure Compensated Controlled Power Limit Volts/Phase/Hertz
39 Maximum System Pressure (MPa) Enclosure
40 Low Operating Pressure (MPa) Minimum starting voltage Run up time (s)
41 NPSH required (water) (m) Temperature rise (C)
42 Max sound press level @ 1 m (dBa) Full load amps (amp) Locked rotor amps (amp)
43 Motor to be suitable for VFD
44 Description Size (NPS) Rating Facing Type Insulation Class
45 (mm) Starting method
46 Suction Lube Grease
47 Discharge Bearings type/number
48 Drain Radial Thrust
49
DATE BY CHK'D APP'D
Equip. No:
Client:
DATA SHEET
Project: HYDRAULIC POWER UNIT
Plant/Area:
NOZZLE CONNECTIONS (By Vendor)
DESCRIPTION OF HYDRAULIC UNIT
HYDRAULIC PUMP
GENERAL
REVISION LOG
REV: DESCRIPTION
WO #: Equip. Name:
ADL Doc. No: ENG-DAT-000085
Indoor Outdoor Heated Unheated
Winterization Required Tropicalization Required
Dust Fumes
Indoor Outdoor Heated Unheated
Winterization Required Tropicalization Required
Dust Fumes
Direct Across the Line Variable Freq. Drive
Pump Vendor Other
Pump Vendor Other
Continuous Intermittent Continuous Intermittent
Included Not Included
Yes No
Source Doc: DS.131.0029M.CAL.R00 Page 1 of 3
Rev: 0
Equip. No:
Client:
DATA SHEET
Project: HYDRAULIC POWER UNIT
Plant/Area:
DESCRIPTION OF HYDRAULIC UNIT
WO #: Equip. Name:
ADL Doc. No: ENG-DAT-000085
1 Rev HYDRAULIC PUMP CONT.
2 BEARINGS AND LUBRICATION
3 Radial: Type Number Manufacturer
4 Thrust: Type Number Type / Size
5 Lubrication: Basic Rating (kNm) / S.F.
6 Max / Min Bore Dia. (mm)
7 Bearing Housing Isolation: Number Required
8 PACKING (By vendor)
9 Type n/a Stuffing box plan No.:
10 Size No. of rings
11 Packing injection required
12 Flow (l/s) @ (C)
13 Lantern ring Lip seals
14
15
16
17 Capacity (l)
18 Operating Level - Min / Max (mm) /
19 Mounting Type
20
21
22 Size
23
24
25
26
27
28
29
30
31
32 Nozzle Size Type Projection Description
33 A Oil Filler (Inlet)
34 B Pump Suction
35 C Oil Return Line
36 Flow Control Valve Type D Drain
37 Number of Control Valves Used H Immersion Heater
38 Valve Manufacturer / Model / L Level
39 Type of Valve Operation Control M Cleanout
40 Manual Valve Control Option provided T Temperature
41 System Pressure Relief Valve V Vent
42 PRV Setting (MPa)
43 PRV Manufacturer / Model /
44
45 Number of Cylinders: Per Leaf Total Gate Closing Force (kN): Operating Max
46 Manufacturer Gate Opening Force (kN): Operating Max
47 Type Gate Crushing Force (kN)
48 Bore Diameter (mm) Rod Diameter (mm) Gate Operating Time (s) Closing Opening
49 Operating Stroke (mm) Max. Stroke (mm) Gate Uniform Motion Control Type
50 Critical Operating Force (kN) High Pressure Hoses
51 Rod Clevis Type Hose Size Hose Rating
52 Diameter Rod Clevis Pin (mm) Manufacturer
53 Diameter Fixed Clevis Pin (mm) Overall Length (m)
54 Cylinder Assembly Cushioned
Note 2
COUPLING (By vendor)
DESCRIPTION OF OIL RESERVOIR
APPURTENANCES (to be provided by Vendor)
Type
OIL DISTRIBUTION MANIFOLD & PIPING (By Vendor)
HYDRAULIC CYLINDERS (By Vendor)
A L V
C
B
D
H
T
M
Grease Flood Ring Oil Flinger
Purge Oil Mist Pure Oil Mist
Filter Pres Transducer Alarm
Sight Level Gauge
Air Breather Filter
Isolation Gate Valve
Magnetic Separator at Suction
Level Transmitter
Temperature Indicator
Drain Valve
Return Line Filter
Oil Filling Filter
V-Sloped Bottom
Immersion Heater
Source Doc: DS.131.0029M.CAL.R00 Page 2 of 3
Rev: 0
Equip. No:
Client:
DATA SHEET
Project: HYDRAULIC POWER UNIT
Plant/Area:
DESCRIPTION OF HYDRAULIC UNIT
WO #: Equip. Name:
ADL Doc. No: ENG-DAT-000085
1 Rev QA INSPECTION AND TEST SURFACE PREPARATION, PAINT and SHIPMENT
2 Review vendors QA programme Manufacturer standard
3 Pump Performance curve approval Client Painting Specification
4 Shop inspection Other
5 Test with substitute seal n/a Shipment
6 TESTING Non-Wit Wit Observe
7 Hydrostatic Remarks:
8 Performance ( Field Test ) RECOMMENDED SPARE PARTS (By Vendor)
9 NPSH Start up Normal maintenance (2 years)
10 Complete unit test Other (specify)
11 Sound level test
12 Vibration Pump (kg)
13 Material Certificates Motor (kg)
14 Welding Reservoir Tank (kg)
15 Hydraulic Cylinders (kg)
16 Skid (kg)
17 Total (kg)
18
19
20
21
22
23 1.)
24 2.)
25
26 3.)
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
WEIGHT
NOTES
Mag. Part. Dye Penetrate X-Ray Ultrasonic
Domestic Export Export Boxing Req'd
Required Not Required
Source Doc: DS.131.0029M.CAL.R00 Page 3 of 3