3C Cu 11kV CTS SWA Conductor Bending Radius mm 2 no of strands Nominal Overall Diameter mm Approximate Mass Kg / km Minimum Installed mm 16 7 47. Listed diameter, mass and bending radii are for PVC / HDPE Composite Sheath. Bending radius based on 25x OD (during installation) and 15x OD.
3C Cu 11kV CTS SWA Conductor Bending Radius mm 2 no of strands Nominal Overall Diameter mm Approximate Mass Kg / km Minimum Installed mm 16 7 47. Listed diameter, mass and bending radii are for PVC / HDPE Composite Sheath. Bending radius based on 25x OD (during installation) and 15x OD.
3C Cu 11kV CTS SWA Conductor Bending Radius mm 2 no of strands Nominal Overall Diameter mm Approximate Mass Kg / km Minimum Installed mm 16 7 47. Listed diameter, mass and bending radii are for PVC / HDPE Composite Sheath. Bending radius based on 25x OD (during installation) and 15x OD.
Listed diameter, mass and bending radii are for PVC/HDPE Composite Sheath. Bending radius based on 25x OD (during installation) and 15x OD (installed) for PVC/HDPE sheath. Bending radius may be lowered to 18x OD (during installation) and 12x OD (installed) for PVC sheath.
Lengths and packing can be supplied to customers requirements. For glanding details, contact your local service centre. NB: Stranding in compacted conductors may be subject to minor variations. 6.35/11kV COPPER XLPE 3C SWA COPPER TAPE SCREEN APPLICATION
Primary supply to urban networks.
PVC/HDPE suitable for installation direct buried or unenclosed where subject to mechanical damage.
Suitable for glanding.
Copper Tape Screen For use where fault currents less than light duty screen occur e.g resistance earthed systems
STANDARD IEC 60502.2
VOLTAGE 6350/11000V
CONDUCTOR Compacted Annealed Copper
INSULATION TR-XLPE Numbered Cores
SCREEN Copper Tape
BEDDING PVC, ST2
ARMOUR Galvanised Steel Wire
SHEATH PVC, ST2 or PVC, ST2 / HDPE, ST7
MAX. OPERATING TEMP. 90 C New Zealand/Energy/Electric Utility Cables/MV XLPe/6.35 - 11kV/Copper Tape/Copper Conductors/3C Cu 11kV CTS SWA
Diagrams of cables are illustrative only and are not necessarily to scale.
General Cable New Zealand Limited reserves the right to change or vary the construction of any of their products without notice. Whilst every care has been taken in the preparation of this publication, General Cable New Zealand Limited accepts no liability of any kind and are not responsible for the results of any actions taken on the basis of this information or resulting from errors or omissions. This technical data sheet is intended as a guide only; any person using it must make reference to the appropriate local standards or authorities. All rights reserved. No part of this work covered by copyright may be reproduced or copied in any form or by any means without the written permission of General Cable New Zealand Limited. General Cable New Zealand Ltd HEAD OFFICE 75-89 Main South Rd PO Box 8044 Riccarton Christchurch Ph: (03) 348 5199 Fax: (03) 348 2009 Website: www.generalcable.co.nz Auckland Service Centre 14-18 Vestey Drive PO Box 22-160 Otahuhu Auckland Ph: (09) 276 1020 Fax: (09) 276 1028 South Island Customer Services 75-89 Main South Rd PO Box 8044 Riccarton Christchurch Ph: (03) 341 3500 Fax: (03) 341 0844 Free Fax (Orders): 0800 242 267 Wellington Service Centre 22 Barnes St PO Box 38-271 Petone Wellington Ph: 0800 222-537 Ph: 0800 CABLES Fax: 0800 242-267
CONDUCTOR CURRENT RATING (a) ELECTRICAL CHARACTERISTICS Nominal Area