This document provides a list of drawings for a wastewater treatment plant project. It includes the paper size, location, drawing number and number of drawing sheets for structural, piping, civil works, and other drawings. The drawings cover areas of the plant like pretreatment units, biological treatment, final settling tanks, irrigation pumping station, sludge treatment facilities and more. Over 60 drawings are specified across various locations and with different paper sizes including A0, A1, A2 and A3.
This document provides a list of drawings for a wastewater treatment plant project. It includes the paper size, location, drawing number and number of drawing sheets for structural, piping, civil works, and other drawings. The drawings cover areas of the plant like pretreatment units, biological treatment, final settling tanks, irrigation pumping station, sludge treatment facilities and more. Over 60 drawings are specified across various locations and with different paper sizes including A0, A1, A2 and A3.
This document provides a list of drawings for a wastewater treatment plant project. It includes the paper size, location, drawing number and number of drawing sheets for structural, piping, civil works, and other drawings. The drawings cover areas of the plant like pretreatment units, biological treatment, final settling tanks, irrigation pumping station, sludge treatment facilities and more. Over 60 drawings are specified across various locations and with different paper sizes including A0, A1, A2 and A3.
Operation Building OP 001,002,003 1 OP 004 Pretreatment Unit PTU 001,002,003,004,005,006,007 1 PU 001,002,003,004,0 05,006,007,008,00 9,010,011 BTP 01,02,03 1 BTP 04 BTP/BS 01,02 1 DT 01,02 1 DT/BS 02,03,04 1 Final setlling tank FST 001,002,003,004,005 2 TWT 01,02 1 TWT/BS 01,02,04,05 1 TWT 03 1 TWT/BS 03 1 EST 001,002,003,004,005 1 EST/BS 001,002,003 1 Reinjection wells RW 001-1,001-2,001-3,002 1 Sludge thickening and storage tanks ST 001,002 1 SDB 001,002,003 1 SBD/BS 021,022,023 1 Cholirantion building CB 01,02,03,04,05 1 Tertiary filtration TF 001,002,003 1 Blower room+ MMC1 + Generator room BR 01,02,03,04 1 Flowmeter FM 001,002 2 Pumping station PS 001,002,003 1 Biological treatment Paper size: A1 Civil Drawings: Layout and sections at GBTP Slude dewatering Emergency Storage tank Irrrigation pumping station Treat WW Storage tank Deaeration tank Location Description Drawging No Bilogical tank Extra platform 7709-03 Blower room Monorail 7505-02 Puddle pipe \ 7571-02 Puddle pipe \ 7576-03 Structural and Piping Drawings: Layout and sections at GBTP Paper size: A2 Irrrigation pumping station Grating layout 7556-02 Location Description Drawging No Pretreatment Unit Sand & Grease outlet 7500-02 Pretreatment Unit Walkway 7501-02 7500-08 7504-02A Final setlling tank Weir & Supports 7645-02 Final setlling tank Clifford 7531-02 Final setlling tank Scrappers & Supports 7532-02 Final setlling tank Scum Collector 7544-02A Irrrigation pumping station Industrial Water Outlet 7514-02 Emergency Storage tank Drainage Piping 7496-02 Sludge thickening and storage tanks General Assembly 7527-02 Cholirantion building Monorail 7518-02 Tertiary filtration Platform 7510-02 Tertiary filtration Wash Water Pipe 7512-02 Tertiary filtration Monorail 7511-02A Blower room Air pipe 7569-02 Blower room Details of air pipe 7506-02 Miscellaneous Piping & Supports 7497-02 Pretreated Water 7503-02 Biological treatment Sludge recirculation from pumping station Sludge recirculation to Biological tank 7507-02 Deaeration tank Biological treatment Structural and Piping Drawings: Layout and sections at Paper size: A2 Air Distribution Pipe 7502-02 Biological treatment Location Description Drawging No Pretreatment Unit Compressed Air 7499-02 Final Settling tank Details of lattice 7530-02A Final Settling tank General Arrangement 7529-02 Irrigation Pumping station Irrigation water Outlet 7513-02 Sludge thickener Details of arms ans scrappers 7528-02 Sludge Treatment Building Dewatered Sludge Outlet 7522-02 Structural and Piping Drawings: Layout and Paper size: A0 Location Description Drawging No Biological tank grating layout SK 02-102 Final Settling tank Weir Plate SK 02-116 Irrigation Pumping station Monorail SK 02-06 Emergency Storage tank Service Piping SK 02-101 Sludge thickening and storage tanks Piping details SK 02-109 Sludge Treatment building Monorail SK 02-111 Structural and Piping Drawings: Layout Paper size: A3