AVEVA Solutions Ltd and its subsidiaries disclaim any and all warranties and conditions, expressed or implied, to the fullest extent permitted by law. The information contained in this document is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or transmitted. The manual and associated documentation may also not reverse engineer, decompile, copy, or adapt the associated software. Any such unauthorised action is strictly prohibited, and may give rise to civil liabilities and criminal prosecution.
AVEVA Solutions Ltd and its subsidiaries disclaim any and all warranties and conditions, expressed or implied, to the fullest extent permitted by law. The information contained in this document is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or transmitted. The manual and associated documentation may also not reverse engineer, decompile, copy, or adapt the associated software. Any such unauthorised action is strictly prohibited, and may give rise to civil liabilities and criminal prosecution.
AVEVA Solutions Ltd and its subsidiaries disclaim any and all warranties and conditions, expressed or implied, to the fullest extent permitted by law. The information contained in this document is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or transmitted. The manual and associated documentation may also not reverse engineer, decompile, copy, or adapt the associated software. Any such unauthorised action is strictly prohibited, and may give rise to civil liabilities and criminal prosecution.
User Guide Disclaimer Information of a technical nature, and particulars of the product and its use, is given by AVEVA Solutions Ltd and its subsidiaries without warranty. AVEVA Solutions Ltd and its subsidiaries disclaim any and all warranties and conditions, expressed or implied, to the fullest extent permitted by law. Neither the author nor AVEVA Solutions Ltd, or any of its subsidiaries, shall be liable to any person or entity for any actions, claims, loss or damage arising from the use or possession of any information, particulars, or errors in this publication, or any incorrect use of the product, whatsoever. Copyright Copyright and all other intellectual property rights in this manual and the associated software, and every part of it (including source code, object code, any data contained in it, the manual and any other documentation supplied with it) belongs to AVEVA Solutions Ltd or its subsidiaries. All other rights are reserved to AVEVA Solutions Ltd and its subsidiaries. The information contained in this document is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or transmitted without the prior written permission of AVEVA Solutions Ltd Where such permission is granted, it expressly requires that this Disclaimer and Copyright notice is prominently displayed at the beginning of every copy that is made. The manual and associated documentation may not be adapted, reproduced, or copied, in any material or electronic form, without the prior written permission of AVEVA Solutions Ltd. The user may also not reverse engineer, decompile, copy, or adapt the associated software. Neither the whole, nor part of the product described in this publication may be incorporated into any third-party software, product, machine, or system without the prior written permission of AVEVA Solutions Ltd, save as permitted by law. Any such unauthorised action is strictly prohibited, and may give rise to civil liabilities and criminal prosecution. The AVEVA products described in this guide are to be installed and operated strictly in accordance with the terms and conditions of the respective licence agreements, and in accordance with the relevant User Documentation. Unauthorised or unlicensed use of the product is strictly prohibited. First published September 2007 AVEVA Solutions Ltd, and its subsidiaries AVEVA Solutions Ltd, High Cross, Madingley Road, Cambridge, CB3 0HB, United Kingdom Trademarks AVEVA and Tribon are registered trademarks of AVEVA Solutions Ltd or its subsidiaries. Unauthorised use of the AVEVA or Tribon trademarks is strictly forbidden. AVEVA product names are trademarks or registered trademarks of AVEVA Solutions Ltd or its subsidiaries, registered in the UK, Europe and other countries (worldwide). The copyright, trade mark rights, or other intellectual property rights in any other product, its name or logo belongs to its respective owner. AVEVA Solutions Ltd MDS ADP User Guide Contents Page 12.0 i MDS ADP User Guide Automatic Drawing Production Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1 Overview of the MDS Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1 Administrators Role . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1 MDS Catalogues and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:2 Using Area Based ADP (Draft Users) . . . . . . . . . . . . . . . . . . . . . . . . 2:1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:1 Starting the Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:1 Starting the MDS-ABA Drawing Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:2 Viewing Existing Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:4 Stored LogFiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:5 MDS User View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:6 MDS Over View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:7 Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:1 MDS Drawing Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:1 MDS Revision Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:3 MDS Scale Override. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:6 MDS Layer Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:7 MDS Rescale Pipe Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:9 Update DM Plotfile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:9 12.0 ii MDS ADP User Guide MDS ADP User Guide Introduction 12.0 1:1 1 Introduction 1.1 Overview Drawings for Multi-Discipline Supports (MDS) are created using the AVEVA Area Based Automatic Drawing Production (ADP) application (referred to as ABA). The purpose of this document is to provide the user with guidance on how to produce MDS drawings from the design model. A pre-requisite to using MDS-ADP is that the Area Based ADP application has been installed and configured by the administrator. It is expected that the MDS-ADP user will not need full AVEVA product training in order to be able to use the application. However, a minimum level of knowledge is required to be able to enter and exit DRAFT in the required models. MDS-ADP allows the user to produce drawings by selecting a support or supports and a template. In an example of a typical MDS-ADP work process, if a user changes the design model for a maintenance project, the drawings used in that area may be updated. The user will enter DRAFT, start ADP, select the area and reproduce all the drawings generated for that area, running the process overnight. This guide has been structured to take the MDS-ADP user through all the steps needed to produce new and modified drawings in a logical order. However, the information has been compiled in a format that should allow a user to reference a particular aspect of MDS-ADP to gain specific information. 1.2 Overview of the MDS Application The MDS application allows the user to create standard supports for pipework, cable trays, and HVAC. The application is highly interactive, enabling the user to design supports with the minimum of effort. It is also highly configurable allowing the administrator to define project-related defaults to control the design of supports and to determine the range and types of ancillary support components that can be used on the project. The standard supports in this application, which are designed using structural sections, are template-driven. A default set of structural templates based on British Standard Steelwork Sections is supplied with the application. All of these templates may be configured to suit the needs of an office or project to adopt a relevant national standard for steelwork sections. 1.3 Administrators Role The administrator is responsible for initial setup of the MDS defaults in the DATASETS stored in the PARAGON database, the default files associated with the MDS application (refer to the Administrator Guide) and setup of the structural steel sizes associated with the framework templates. The MDS application is supplied with a British Steel set of framework 12.0 1:2 MDS ADP User Guide Introduction templates, which the administrator must modify to suit the specific requirements of the project. 1.4 MDS Catalogues and Specifications The MDS application is supplied with a catalogue and specification. The range of bore and components in the catalogue are fixed and should be adequate for all projects. The catalogue supplied and associated /MDS specification must not be modified by the administrator or any other user. MDS ADP User Guide Using Area Based ADP (Draft Users) 12.0 2:1 2 Using Area Based ADP (Draft Users) 2.1 Introduction The only functionality a normal DRAFT user has within the Area Based ADP application is the ability to create drawings using the administrative elements previously defined by a DRAFT administrator such as Templates and Tasks. If any of the application components covered in this user guide do not exist, consult your DRAFT ABA administrator. 2.2 Starting the Application To begin creating one or more ABA drawings, click on Draft on the top menu bar and select Auto Drawing Production from the drop down menu (Figure 2:1.: Draft Main Menu). Figure 2:1. Draft Main Menu This loads the ADP top menu bar containing the Area Based ADP menu selections. (Area Based ADP Defaults in the Settings menu and MDS Drawings in the Create menu). For information on setting the MDS Area Based ADP defaults, refer to the MDS Customisation Guide. 12.0 2:2 MDS ADP User Guide Using Area Based ADP (Draft Users) 2.3 Starting the MDS-ABA Drawing Process From within the Automatic Drawing Production module, click on the Create top bar menu and select MDS Drawings from the drop down menu (Figure 2:2.: ABA Create menu). Figure 2:2. ABA Create menu The Create MDS Drawing form now appears, allowing the user to begin creating drawings (Figure 2:3.: Create MDS Drawing form). MDS ADP User Guide Using Area Based ADP (Draft Users) 12.0 2:3 Figure 2:3. Create MDS Drawing form This form allows you to: Select either of the two options from the Load Supports menu to populate the form lists with the available MDS supports: CE & Below selects and populates the form with all supports below the current element, including the MDS support the current element belongs to. All in MDB selects and populates the form with all the MDS supports found in the current MDB. Select the Drawing Registry to write the drawing to (select an item from the Drawing Registry window). Select any elements to include in a drawing from the lists in the Frameworks, Hangers and Ancillaries windows. Click on the CE button to select the current element. Lists can be filtered using the Selection Filter gadget. Select a template from the Template gadget. Select existing drawings to be updated or regenerated by clicking the Existing Drawings button (see Viewing Existing Drawings). Review the run time logfiles by clicking the Stored LogFiles button (see Stored LogFiles). Check the Detail Sheets box to produce steelwork shop detail drawings. Click on the Apply button to finish the process when satisfied with your selections. This will initiate the individual MDS ABA drawing creation process for all the selected supports in each of the support type list gadgets. 12.0 2:4 MDS ADP User Guide Using Area Based ADP (Draft Users) Figure 2:4. Typical MDS ABA Drawing 2.3.1 Viewing Existing Drawings Click the Existing Drawings button on the Create MDS Drawing form above to view existing drawings (Figure 2:5.: ABA Browse Sheets form). The latest MDS ABA drawing created will be displayed (Figure 2:4.: Typical MDS ABA Drawing). MDS ADP User Guide Using Area Based ADP (Draft Users) 12.0 2:5 Figure 2:5. ABA Browse Sheets form Use this form to: Refresh the list of available drawings (Select File > Reload from the top menu bar). Display a form to read any stored log file (Select Browse>Stored LogFiles from the top menu bar). Modify Template View(s). Right-click an item to display the ABA Template View form and access the Views available under the Sheet Template from which the picked drawing was derived. Modify Template Sheet. Right-click an item to display the ABA Template Sheet form and access the Sheet Template from which the picked drawing was derived. Modify Template Drawing. Right-click an item to display the ABA Template Drawing form and access the Drawing Template from which the picked drawing was derived. Click on Cancel to return to the Create MDS Drawing form. Note: The three modify functions are only available to an ABA DRAFT administrator (Area Based ADP Administrator Guide). 2.3.2 Stored LogFiles To access logfiles click the Stored LogFiles button on the Create MDS Drawing form (Figure 2:3.: Create MDS Drawing form). The form shown in Figure 2:6.: Stored LogFiles form is displayed. 12.0 2:6 MDS ADP User Guide Using Area Based ADP (Draft Users) Figure 2:6. Stored LogFiles form Use the browser to navigate to the required directory (the default is %PDMSABALOG%), and then select the required file. You can then: View the current LogFile. Edit a LogFile by selecting Edit and clicking on Apply. This brings up a default editor. Load the contents of a LogFile into the selection fields of the Create MDS Drawing form. To do this select Load and click on Apply. This allows you to re-create a previous process run. Click on the Dismiss button to return to the Create MDS Drawing form. (If the Process Drawings Control form is displayed, this can be ignored; click Cancel to close the form). 2.3.3 MDS User View You will need sufficient working knowledge of DRAFT to make use of this facility. An additional view may be created on an existing MDS ABA drawing, called a 'User View', which is displayed on the graphical canvas of the main form in the Automatic Drawing Production application. A User View is an additional view created by copying an existing view at the users selected location on the existing drawing. This view will be regenerated each time the MDS ABA drawing is recreated, and the drawing creation process will generally update any DRAFT elements, e.g. Dimensions etc., as required. The User View is recognised by the MDS ABA application by setting the view attribute SpPurpose to USER. A User View may only be created from a valid MDS ABA view, and not from a User View. MDS ADP User Guide Using Area Based ADP (Draft Users) 12.0 2:7 You can modify the view as required by modifying attributes and creating or deleting view elements etc. Manipulation and/or positioning of the DRAFT elements in the view may also be done. Select Create>MDS User View from the ADP top menu bar. The prompt Identify VIEW to be copied from or ESCAPE is displayed. Identify any element in the view to be copied. The 'Point Construction Option Form' will be displayed, with the option '2D Cursor hit' selected as default. Figure 2:7. Point Construction Option form Locate the centre of the User View on the canvas via the 'Cross Hairs' displayed on the screen. An exact copy of the copied view is created at the selected location. The view can now be modified as required. 2.3.4 MDS Over View An Over View is an additional view created by copying an existing view at the exact location of the existing view on the existing drawing. This view will NOT be regenerated each time the MDS ABA drawing is recreated. The Over View is recognised by the MDS ABA application by setting the view attribute SpPurpose to USER. An Over View may only be created from a valid MDS ABA view, and not from a User View. An Over View only copies the MDS support elements, and does NOT copy anything else, e.g. Dimensions, Pat No. tags etc. Select Create>MDS Over View from the ADP top menu bar. The prompt Identify VIEW to be copied from or Escape is displayed. Identify any element in the view to be copied. The Over View is created by overlaying the new Over View exactly over the top of the existing view. The purpose of this type of view is to clarify the design of the MDS support elements, e.g. as in a Plan View, by drawing the MDS support elements in full if they are obscured and drawn in 'hidden detail' representation below the main structural supporting steelwork members. An additional note inside parenthesis will be added to the existing view title, i.e. (Support shown in full detail for clarity). 12.0 2:8 MDS ADP User Guide Using Area Based ADP (Draft Users) MDS ADP User Guide Utilities 12.0 3:1 3 Utilities This section describes the use of the last four items accessible from the Utilities drop down menu (Figure 3:1.: Utilities menu). Figure 3:1. Utilities menu 3.1 MDS Drawing Lock Use this option to lock a drawing, preventing any changes to be made. 12.0 3:2 MDS ADP User Guide Utilities Select the option Utilities>MDS Drawing Lock and the form shown below is displayed. Select the Lock Drawing option and click on Apply to lock the drawing. To unlock a drawing, select Unlock Drawing and click Apply. A locked drawing will NOT be deleted and/or overwritten via the MDS ABA drawing creation process, even if the MDS support name is selected in the main 'Create MDS Drawing' form. However the user will have to check the ABA log file, e.g. %PDMSABALOG%/Aba_7-J une- 07_10-52-36.log, for the list of MDS support drawings successfully created or aborted. A typical ABA log file output is shown below. ==================================== ABA Log Fi l e - Pr ocessi ng 1 Dr awi ngs ==================================== Ent r y f or Dr awi ng / MDS- ABA- 3- VI EWS( METRI C) - PS01005- AREA ( =23706/ 324, =22384/ 63420) End of Pr ocess Li st Pr ocessi ng Dr awi ng ( 1 of 1) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 J un 2007 10: 52: 37 Cannot del et e ol d dr awi ng / MDS- ABA- 3- VI EWS( METRI C) - PS01005- AREA as i t i s l ocked - Dr awi ng abor t ed Dr awi ng ( 1 of 1) Pr ocessed - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Dr af t r un- t i me war ni ngs: 64, 353) 0 el ement s wi t h nul l or i l l egal I DNM at t r i but es have been del et ed. I DLI ST / MDS- ABA- 3- VI EWS( METRI C) - PS01005- AREA/ S1/ V7/ I DLI ST/ I DLI 64, 353) 0 el ement s wi t h nul l or i l l egal DDNM at t r i but es have been del et ed. VI EW/ MDS- ABA- 3- VI EWS( METRI C) - PS01005- AREA/ S1/ V7 64, 353) 0 el ement s wi t h nul l or i l l egal I DNM at t r i but es have been del et ed. VI EW/ MDS- ABA- 3- VI EWS( METRI C) - PS01005- AREA/ S1/ V7 Cannot del et e ol d dr awi ng / MDS- ABA- 3- VI EWS( METRI C) - PS01005- AREA as i t i s l ocked - Dr awi ng abor t ed MDS ADP User Guide Utilities 12.0 3:3 3.2 MDS Revision Control To use this function: 1. Select MDS Revision Control from the Utilities menu to display the following form: 2. Click on the New Revision button and the form changes as shown below: 12.0 3:4 MDS ADP User Guide Utilities 3. Enter the information you want to add to the drawing. An example is shown below: MDS ADP User Guide Utilities 12.0 3:5 4. Click on the Apply button to update the information on the drawing as shown on the extract below: 12.0 3:6 MDS ADP User Guide Utilities Subsequent updates of drawings retain revision information. Positioning, revision text, and number of allowable revisions are controlled via the drawing template. See the MDS Administrator Guide for more information. 3.3 MDS Scale Override MDS calculates the scale required to fit the whole support within the views. If this scale is unacceptable, the user may override the scale calculated by MDS and force a scale to be used. To do this: 1. Select MDS Scale Override from the Utilities menu to display the following form: 2. Select the required scale from the Scale drop down box and click on the OK button. In the example shown below a scale of 1/10 has been selected. MDS ADP User Guide Utilities 12.0 3:7 3.4 MDS Layer Control The layers created on a MDS drawing can be controlled. To do this, Select MDS Layer Control from the Utilities menu to display the following form: The View gadget shows the current editable view. To turn the whole view on or off, use the toggle in the top right of the form. The Layer list shows all the current layers in the selected views. Highlighting a layer displays its members in the lower box. Right-click on the Layer list to show the following submenu: 12.0 3:8 MDS ADP User Guide Utilities The Layer Members list shows all the members of a particular layer. Click on a member to toggle between show, and hide. In the example shown below two members have been set to hidden. Each menu item works as follows: Show All shows all members of the selected layer. Hide All hides all members of the selected layer. Show/Hide on selection changes the behaviour of the list so that when the user selects the list all the members will be shown or hidden depending on their current state. Hide Layer by Cursor displays the prompt Identify LAYE in the graphical canvas. Identifying a single element in a current view will hide all elements contained in the owning LAYE element. The LAYER list shows the layers that are hidden: MDS ADP User Guide Utilities 12.0 3:9 3.5 MDS Rescale Pipe Symbols This utility is used to rescale pipe symbols to suit the VSCA view scale attribute. Select Utilities>MDS Rescale Pipe Symbols from the main menu. The utility will try to navigate to a DRAFT view element, but if it is unable to navigate to a view you will be prompted to 'Identify view to rescale pipe symbols' in the graphical canvas. In both cases once the utility has navigated to a view element, the pipe symbols shown in the view are automatically rescaled to suit the VSCA view scale attribute. Note: Currently only two types of pipe symbols may be rescaled on MDS drawings. Both pipe symbols are represented by DRAFT SLAB (Symbol Label) elements with the TMRF(Template reference) attribute set to either /DRA/MAS/SYMBOLS/GEN/ BREAKS/BB-1 or /MDS/ABA/TAGS/BREAK/PIPE 3.6 Update DM Plotfile Select Update DM Plotfile from the Utilities menu to update the Deliverable Manager (DM) plot file with the latest copy in DRAFT. Use this when modifications have been made in DRAFT. Update DM Plotfile overwrites the file and runs any post-actions required by DM, for example DM drawing stickers. Note: This utility requires that the AVEVA Delivery Manager and AVEVA Model Object Manager software products are installed and working on the current project. 12.0 3:10 MDS ADP User Guide Utilities Index 12.0 Index page 1 MDS ADP User Guide A Area Based ADP using . . . . . . . . . . . . . . . . . . . . . . . . . 2:1 D DM Plotfile updating . . . . . . . . . . . . . . . . . . . . . . 3:9 Drawing Lock . . . . . . . . . . . . . . . . . . . . . 3:1 E Existing Drawings viewing . . . . . . . . . . . . . . . . . . . . . . . 2:4 L Layer Control . . . . . . . . . . . . . . . . . . . . . 3:7 M MDS Application overview . . . . . . . . . . . . . . . . . . . . . . 1:1 MDS Catalogues . . . . . . . . . . . . . . . . . . . 1:2 MDS Over View . . . . . . . . . . . . . . . . . . . 2:7 MDS Specifications . . . . . . . . . . . . . . . . . 1:2 MDS User View . . . . . . . . . . . . . . . . . . . . 2:6 MDS-ABA Drawing Process starting . . . . . . . . . . . . . . . . . . . . . . . 2:2 R Rescale Pipe Symbols . . . . . . . . . . . . . . 3:9 Revision Control . . . . . . . . . . . . . . . . . . . 3:3 S Scale Override . . . . . . . . . . . . . . . . . . . . 3:6 Stored LogFiles . . . . . . . . . . . . . . . . . . . 2:5 U Utilties menu options . . . . . . . . . . . . . . . . . . . . . . . 3:1