BW CT Workstation is a professional product in the CT image post-processing field, complying with the DICOM3. And IHE international standards. It has powerful image processing functions which can help physicians make quick and accurate diagnosis.
BW CT Workstation is a professional product in the CT image post-processing field, complying with the DICOM3. And IHE international standards. It has powerful image processing functions which can help physicians make quick and accurate diagnosis.
BW CT Workstation is a professional product in the CT image post-processing field, complying with the DICOM3. And IHE international standards. It has powerful image processing functions which can help physicians make quick and accurate diagnosis.
Professional Computer Aided Diagnosis Products Embedded Neusoft Medical is a leading provider of digital medical solutions in China. It has a long history of medical product development and owns tens of thousands of end customers. BW CT Workstation is a professional product in the CT image post-processing field, complying with the DICOM3.0 and IHE international standards. Beyond Image BW CT Workstation Basic BW CT Workstation Professional BW CT Workstation Ultimate * Specialized and modularized BW CT Workstation has powerful image processing functions which can help physicians make quick and accurate diagnosis. The whole product series includes: BW CT Workstation Basic integrates the functions of patient manager, image view, report editing and film printing and its key features are supporting oblique/ double oblique MPR, MIP, CPR and VR, supporting marking of key image, ensuring consistency of image display and supporting sending, transmitting and receiving DICOM data between SCU and SCP. Compared with the Basic version, BW CT Workstation Professional offers more advanced image post-processing functions, including CTA analysis of the vessels in head and neck, coronary artery, abdomen and lower limbs, BMD measurements of osteoporosis-sensitive body parts, spine and femoral neck as well as the Dental functions assisting dentists in diagnosis and treatment. BW CT Workstation Ultimate is the most advanced product, covering all of the advanced post-processing functions, including UroCARE for the diagnosis of urinary system, NeuColonCARE for the virtual colonoscopy, NeuLungCARE for the analysis of lung nodules and functions, CT Perfusion for cerebral analysis and PETCARE for the fusion of PET images and CT images. We can customize product on the basis of BW CT Workstation Basic according to the specific requirements. Image View Function Image view function provides the doctors with multiple view modes and observation angles and supports the VR display of the relationship between the lesion and the surrounding structure, overcoming the defects of conventional film-reading and facilitating the design of the treatment planning. Provide image-processing tools of annotation, pseudo color, filtering, image enhancement and etc.; supports user customizing personalized tool panel and follow-up comparison of multiple series. Associate the image with its critical annotations to ensure the output consistency of the image. MPR Slab supports the arbitrary adjustment of the thickness and oblique; double oblique MPR reconstruction supports the angle adjustment ; the thickness and range of the oblique series can be defined. CPR, an interactive manual operation mode, supports the definition and management of multiple spatial curves and functions of editing, reverse order and renaming. Support the view modes of MIP (Maximum Intensity Projection), MinIP (Minimum Intensity Projection), AIP (Average Intensity Projection) and VR (Volume Rendering). 3D filter tool can directly cut on the 3D view to remove the non-target tissues. Provide multiple VR schemes according to the features of different body parts and support user customization. VR View of Scoliosis MPR oblique MinIP (Trachea) Thickness: 6mm MIP (Coronary Artery) Thickness: 10.9mm CTA Advanced Analysis Function CTA advanced analysis function is specially used for the analysis of the vascular lesions in the head and neck,coronary artery, abdomen and lower limbs, which can help doctors evaluate the vascular stenosis degree, soft/hard plaque features, scope, vulnerability degree and provide the lesion position, shape and its relationship with the surrounding tissues, effectively reducing the patients suffering and having great application value for the clinical analysis and diagnosis. Automatic segmentation of cardiac and coronary artery tree. One-click registration, subtraction and extraction of head and neck vessels. Automatic extraction of vessels in abdomen and lower limbs. Automatic detection and management of lesions. Provide multiple views of MPR/straightened CPR/cross-sectional view for doctors to evaluate the lesion from different angles. Automatic addition and interactive editing of vessel centerline; convenient vessel editing, naming and management. Quantitative analysis of multiple vascular parameters, providing quantitative information for the diagnosis. Subtraction Angiography CTA of Head and Neck Angiography Image (Left) Subtraction Angiography (Right) CTA of Abdomen and Lower Limbs Angiography Image (Left) Boneless Angiography Image (Right) Coronary Artery CTA Coronary Artery Tree (Left) CPR View (Right) Observe Heart from Six Special Angles BMD Measurements BMD measurement function can professionally analyze the osteoporosis-sensitive body parts, spine and femoral neck, calculate the BMD values of cortical bone, trabecular bone and total bone together with the thickness of cortical bone, effectively helping doctors diagnose and treat the osteoporosis. Professional BMD Measurement Report BMD Result (Non-Segmented Method) Position BMD(mg/cm^3) BMD,(mg/cm^3) T-score T-Score: the multiple of the standard deviation compared with the young people Z-Score: the multiple of the standard deviation compared with their peers Average Reference Value Normal Osteopenia Osteoporois Severe Osteoporosis T-Score>-1 -2.5<T-Score<-1 T-Score<-2.5 -2.5, and meanwhile one or more body parts have fracture Age Professional BMD report, Name: Age: Sex: Mondality: Study ID: Study Time: Separate BMD measurement and calculation of cortical bone and trabecular bone. Definition and measurement of 2D ROI and 3D VOI. The measurement results of with-phantom calibration and without-phantom calibration are highly consistent. Professional BMD report, including age-related normal curve, T-Score, Z-Score, and BMD values of 2D ROI and 3D VOI. Dental Function Dental Function provides a new solution for the dental diagnosis and treatment, which can help doctors to make a program before the dental implant so as to reduce risks that may arise during surgery. In virtue of 3D imaging technology, doctors can know the accurate dental implant position, angle as well as the implant size and length. Provide the panoramic view of jaw and the cross-sectional image of the teeth, helping doctors make dental implant surgery plan. Provide VR and MIP views, helping doctors observe the jaw structure. Provide tools of measuring length and angle and adding annotation, allowing doctors to acquire key information at any time. Panoramic View of Jaw UroCARE QCT__@Qqgg] gq__Qjgg] UroCARE is a unique software product designed for the urinary system, which provides urologists with customized workflow and views, greatly meeting the doctors requirements towards the views. Simulate the abdominal plain film with enhanced CT scout to make the view be clearer. CT KUB Qg] q_g] QCT__@Qqgg] gq__Qjgg] Stone in the Original CT Scout Stone in the Enhanced CT Scout Comprehensive HD ROI Analysis Provide the functions of HD ROI detection and measurement, kidney segmentation and 3D visualization. Automatic segmentation of stone and kidney. Output stone measurements. Show the distances from the stone in the ureter to kidney and bladder. The stone and kidneys can be fused onto the KUB image and can be linked with the MPR view. VR View of Stone and Kidney Stone and Kidney Fusion Image NeuColonCARE NeuColonCARE is an image post-processing workstation, especially designed for the colon department, including virtual colonoscopy, virtual dissection and ROI analysis. The product especially adopts the advanced cube unfolding function to enhance the users interactive experience and help users find the ROI in the colon. Flexible view layout ensures the best observation position. Diversified views, Easy-to-use tools, Optimized workflow One-click colon segmentation and centerline extraction. Provide the function of view linkage so that users can observe the ROI on different views. Provide annotation and measurement tools. Provide a 360 colon panoramic view and the user can observe the details of the colon wall. High-quality virtual dissection view. NeuColonCARE can open a prone series and a supine series simultaneously. By this way, the residual waste on the surface of the colon mucosa can be moved. Contrast of Prone Series and Supine Series Contrast of Prone Series and Supine Series 360 Colon Panoramic View Dissection Views of Double Series NeuLungCARE Based on lung CT images, NeuLungCARE can automatically detect lung nodules and emphysema and quantitatively analyze lung nodules and lung function. A solution for lung nodules Automatically segment the suspicious lesions and display the quantitative parameters of the segmented area. Provide VR view of suspicious area for the observation of local vascular structure. Nodule follow-up information management. Automatic detect and measure the suspicious lesions in lung; can detect and measure several types of nodules. Diagnose pulmonary diffuse diseases Accurate and quantitative lung function analysis and emphysema detection Calculate the lung volume, surface area and other important functional parameters. Pulmonary pixel index table and curve. Visually show the emphysema area by covering emphysema with green color. Output analysis results in Excel table. Local VR View of Nodule Pulmonary Pixel Index Curve Original Image (Left) Emphysema Covered by Green (Right) CTPerfusion (a) (b) (c) (d) CT Perfusion is an image processing software package based on CT dynamically scanned series, which can provide the parameter maps of cerebral blood flow, cerebral blood volume, mean transit time and time to peak and can automatically calculate the ratio of core infarct to penumbra, helping doctors find the ischemic lesions and assisting them in the early diagnosis and prognosis of cerebral infarction as well as helping doctors evaluate the effect of thrombolytic therapy. (a) Cerebral Blood Volume(CBV), (b) Cerebral Blood Flow (CBF), (c) Mean Transit Time (MTT) , (d)Time To Peak (TTP), Provide parameter maps of TTP, MTT, CBV and CBF. Accurate quantitative analysis of CBF system to effectively remove the recycling influence. Can mark ROI and provide flexible layout. You can draw the core infarct zone and penumbra on any two parameter maps and the product will automatically output the ratio of core infarct zone to penumbra. Protraction and Measurement of Core Infarct Zone and Penumbra Remove Vessel and Skull PETCARE (a) (b) (c) (d) PETCARE is a PET image and CT image registration and fusion post-processing workstation, which provides the functions of image acquisition, transmission, standard fusion, linkage view, quantitative analysis and report, assisting PET doctors in the clinical work of image view and quantitative analysis. Accurate Registration Quick and accurate auto-registration makes it possible to conduct registration on different machines and the registration accuracy can reach the sub-pixel level. (a) Original CT Image (b) PET CT Fusion Image (c) Original PET Image (d) MIP of PET Image Flexible view layout, Abundant measurement tools, Multiple color maps The measurement tools and color maps enable the doctors to track the changes of the tumor. Switch view layouts by clicking one button. Generate MIP of rotating PET image. Link PET image and MPR image; clicking one button and all views changed. Show SUV value in real time. Automatic segmentation of lesion. Auto-Segmentation and SUV Measurements, Output Local Max Value, Mean Value and Center Value B W
C T
W o r k s t a t i o n
V 1 . 0 medical.neusoft.com No.16, Shiji Road, Hunnan Industrial Area, Shenyang, Liaoning, China, 110179. Tel: (86 24) 8366 3229 Fax: (86 24) 2378 7346 E-mail:medicalitint@neusoft.com Neusoft Medical Systems Co ., Ltd. On account of certain regional limitations of sales rights and service availability, we cannot guarantee that all products included in this brochure are available through the Neusoft sales organization worldwide. Availability and packaging may vary by country and is subject to change without prior notice. Some/All of the features and products described herein may not be available in the U.S. or EU.