THE ROSENBERGER OSI PRODUcT CATALOG

welcome

to the world

of Rosenberger OSI

200 PAGES OF CABLING COMPETENCE:

AN OVERVIEW

company
Rosenberger OSI is the name for most superior cabling and
connectivity solutions. Learn why innovation is our daily
business.
page 6

APPLICATIONS
Our products are to be found where highest data
volume is transmitted in a fast and reliable way. Be it
a data center or an antenna mast.
Page 14

overview connectors inside

Services
Excellent products do not automatically ensure successful
project completion. That is why we support you with
substantial services.
page 32

TECHNOLOGY
For good reasons Rosenberger OSI is a synonym for
innovation. On the following pages you will find some of the
key technologies rendering our products that successful.
page 44

PRODUCTS
Around 3,000 of more than 40,000 products which belong to
the best the world of cabling has to offer. Clearly arranged
and presented with all relevant properties.
page 56

ROSENBERGER OSI PRODUCT CATALOG

53

LC

1.25

Compact
(Uniboot)

Simplex

Duplex

Mini-LCDuplex

Latched
push-pull
locking

iec 61754-20

Compact

MU

Duplex

SC

20 MM
45 SM PC
-40 to
55
SM
UPC
+85
1MM Low
Loss Type 70 SM APC

1.25

Push-pull

2.5

Push-pull

iec 61754-4
en 50377-4

2.5

Latched
push-pull
locking

iec 61754-15
EN 50377-8

20 MM
0.25 SM 45 SM PC
-40 to
0.4 MM 55 SM UPC +85
70 SM APC

Precisioninjection
molded
plastic

Push-pull

iec 61754-7

0.6 SM 20 MM
-40 to
0.35 MM 55 SM APC +85

Precisioninjection
molded
plastic

Latched
push-pull
locking

iec 61754-18

0.6

20 MM
35 SM

2.5

Screw

iec 61754-13
en 50377-2

0.4

20 MM
45 SM PC
-40 to
55 SM UPC +85
65 SM APC

2.5

Bayonet

iec 61754-2
mil-c-83522
iec 60874-10

0.4

20 MM
-40 to
40 SM PC
+85
45 SM UPC

2.5

Screw

iec 61754-3
former
din 47256

0.4

20 MM
-40 to
45 SM PC
+85
55 SM UPC

Screw

iec 61754-22

0.8

Compact

(LSH)

Simplex

Duplex

Female

MTP

MPO

Duplex
DuplexCompact

8/12/24

fibers

Male

Male

MT-RJ
Female

FC

0.4

2 fibers

PC

ST

t e m pe
r at u r
e
r ang e
[ C ] *

0.151
0.3

Simplex

E-2000

min. re
tu
loss [d rn
B]

20 MM
45 SM PC
-40 to
55 SM UPC +85
1MM Low
Loss Type 70 SM APC

iec 61754-6
EN 50377-10

Simplex

Duplex

0.151
0.3

20 MM
45 SM PC
-40 to
55 SM UPC +85
65 SM APC

-40 to
+80

Type: metal

DIN

(LSA)
Type Diamond:
metal/ceramic

F-SMA

N.A.

-40 to
+115

MTP is a registered trademark of US-Conec Ltd. - E2000 is a registered trademark of Diamond S.A. - * limitations due to the used cable material are possible

Standard
Compact

m a x . in
se
lo ss [d r t io n
B]

ar d
S tan d

Lo c k in
g
m echa
n is m

]
le [mm
Fe r r u

x
d u pl e

ode
mode
sm apc
sin g le

WITH PARAMETERS

Mu lt im

IMPORTANT
CONNECTORS

ALWAYS WITHIn SIGHT:

THE most significant CONNECTORS


All of our PreCONNECT products, patchcords and pigtails are
available with various connectors to cover all fields of application.
The fold-out page helps keeping track while exploring our products or dealing with lists of part numbers. The most important
parameters are available at a glance. Further information about
the different connectors is available on pages 6289.

company

ROSENBERGER OSI PRODUCT CATALOG

EACH OF OUR PRODUCTS HAS VARIOUS CERTIFICATES.

AND AN UNMISTAKABLE

PERSONALITY.
This catalog you currently hold in hands covers
about 3,000 of more than 40,000 products
belonging to the best you can find on market.
Above that it shows our passion for the subject
of cabling the source of all of these examples
of superior performance.
Within more than 20 years, due to our passion,
this ambitious startup of 1991 has become
the synonym for Cabling Competence. Its the
people with passion for technical challenges.
Personalities with their heart set to solve all
major and minor small problems our customers
are confronted with every day. Our staff members with their meticulousness and highest
degrees of personal commitment are the reason
for the excellent quality of every single product.

They all made it happen that nowadays


Rosenberger OSI is not only synonym for stateof-the-art cabling but also for an innovative spirit
and an exceptional customer orientation.
Regardless, if its about individual customization
of a connector, the equipment of a mobile outside broadcast vehicle or the conception of an
infrastructure for a data center: the result will
exactly meet the requirements and exceed your
expectations.

From simple pigtail to complete


cabling of DC-infrastructures with
Rosenberger OSI your cabling is in
good hands

ROSENBERGER OSI PRODUCT CATALOG

company

OUR CABLING KNOW-HOW IS COMPREHENSIVE.

OUR FOCUS IS FIBER OPTICS.


Innovative solutions for fiber-optic IT cabling
were the objective for the foundation more than
two decades ago. And even today fiber optics
is our core competence. Within that focus area
and in related fields we developped numerous
innovative solutions, which are considered to be
unperalleled in their application areas.

In first place our PreCONNECT FIBER Trunks set


world-wide standards for high-speed-cabling of
data centers (see pages 94101). With up to 144
fibers these highly integrated data highways
comprise the backbone of modern data centers
which are forced to fulfill constantly rising performance requirements. But also our outdoor
trunks and breakout cables which are wastly
emplemented especially in the field of mobile
communication are internationally acknowledged as model for the technically feasible.

ROSENBERGER OSI PRODUCT CATALOG

LC-Compact and Heavy Duty 600


Two reliable guarantors for top
performance

In the meantime we have accomplished to transfer


our know-how from fiber optics to copper-based
IT cabling. There-fore, despite of its six channels,
our PreCONNECT Copper Trunk ToR belongs to
the thinnest and most flexible of its kind and is
perfectly suited for Top-of-Rack installations. And
for harsh environments our hybrid connectors of
the Heavy Duty Series (see pages 8285) have
the reputation of being the best performing and
robust solution.

ROSENBERGER OSI PRODUCT CATALOG

Independent of your application requirements:


with each of our products you opt for many
years of practical experience, engineering at
highest level as well as uncompromising and meticulous production. And for perfect satisfaction.

company

10

ROSENBERGER OSI PRODUCT CATALOG

Production in Taksony
All Rosenberger OSI products
are subjected to extensive
quality inspections

WE LIKE BEING METICULOUS.

EVEN IF IT IS ABOUT

SHORTEST LEAD TIME.


Rosenberger OSI has an excellent reputation as
provider for high-end components and supplier
of individually customized solutions. For that
reason at first glimpse many people are surprised to find out about our huge manufacturing capacities and the efficiency of our logistics.
In fact we are proud of bringing the agility and
flexibility of a smaller medium-sized company
so ideally into accord with the power of vastly
larger competitors.
The main reason for this is to be found in
Taksony near Budapest: our production and
logistics center significantly expanded and
modernized in 2011. On about 3,500 square
meters there are five semi-automatic production
lines specifically dedicated to the respective
product groups with a future-proof dimensioned high rack storage area and an efficient
shipping department.
Additional optimization of the production
processes enabled further growth of the already
high throughput. To note: not diverging in the
least from our high quality standards.

ROSENBERGER OSI PRODUCT CATALOG

In combination with our project-management


and quality assurance procedures, certified
according to international standards, this
ensures that we can meet shortest delivery
times. This especially applies for vast projects
such as new construction of a large data center
or equipping a comprehensive mobile phone
network.

Rosenberger OSI is certified according to the


following guidelines:
PVP
Premium Verification Program of the GHMT

DIN ISO 9001:2008

DIN ISO 14001:2004

11

COMPANY

INNOVATION ALWAYS WAS

OUR STRENGTH.
AND THAT WILL continue to BE like that.

12

ROSENBERGER OSI PRODUCT CATALOG

2011

20 years Rosenberger OSI

2010

Expansion of production and logistics area at production


site in Taksony by more than 1,500 m

2009
2008

Large scale production of optical fiber connectors SC, LC, MU

2007

Launch of PreCONNECT COPPER the factory assembled


trunk system in the copper cable segment

2006
2005
2004

Series manufacturing of own MU and SC connectors

2003

Introduction of the MU connector,


development of PreCONNECT Mobile

2002
2001
2000
1999

Doubling of production capacity in Taksony/Hungary; new site in


Augsburg
Reinforcement of lead in the market by development of trunks with
144 fibers and MTP/MPO multi-fiber connectors, award of first
IBM FTS qualification

1998

Merge with Rosenberger group

1997

Expansion of production capacity,


new production site in Taksony/Hungary

1996
1995

First production of high density fiber trunk systems for IT


cabling of data centers world-wide

1994
1993
1992
1991

Foundation of the company in Ichenhausen

MTP is a registered trademark of US-Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

13

WHERE YOU CAN FIND OUR PRODUCTS:

THE FIELDS OF APPLICATION


Cabling by Rosenberger OSI is found wherever highest data transmission rates, lowest
susceptibility against interference and exceptional longevity are crucial. In our world the data
traffic is increasing daily and that applies more and more outside fo data centers as well.

Data Center
Modern data centers are the control rooms of todays
world. Especially the cabling as communication interface
must meet and fulfill highest requirements regarding
reliability.

page 16

Mobile Communication
Mobile telephony and comprehensive data services
are characterized by rapidly increasing data rates. The
cabling does not only have to keep pace in contrast it
has to anticipate future standards.
page 20

14

ROSENBERGER OSI PRODUCT CATALOG

Broadcast
Live transmission of big events in HDTV resolution rapidly
creates large data streams. On site our fiber cables and
connectors must withstand extreme operational demands.
PAGE 24

INDUSTRIAL
The harshest environmental conditions are to be found in the
industrial area. In mining industry, offshore platforms or aviation: Heavy Duty products reveal whats in them.
Page 28

ROSENBERGER OSI PRODUCT CATALOG

15

application field Data Center

BILLIONS OF ARITHMETIC OPERATIONS PER SECOND.

WHATs their value

WITHOUT CABLES?

16

ROSENBERGER OSI PRODUCT CATALOG

When thinking of data centers in general,


pictures of incredibly powerful hardware components turn up. Cabinets packed with countless processing units capable of astronomical
computational power. Who doubts, that here
the proper work is done. But without cabling
the whole setup can not fulfill its purpose.

ROSENBERGER OSI PRODUCT CATALOG

THE LIMITS OF THE PHYSICALLY FEASIBLE


And indeed it is everything but trivial to transport these vast amounts of data error-free, fast
and in a reliable way between the different
active components of a data center. Constantly
rising data rates urge us to challenge the limits
of the physically feasible in cabling.

17

application field Data Center

Cabling:
the BACKBONE
OF EVERY DATA CENTER
Since more than 20 years Rosenberger OSI has
managed data center projects of every size from
30 to 20,000 square meters of IT space. Therefore we can claim without exaggeration to know
exactly which challenges have to be met and
which risks are frequently and unnecessarily
taken. Because efficient cabling is the basis of
all and any processes and has to be considered
from the very beginning of the design phase of
the data center.
COMPREHENSIVE SOLUTIONS
FROM ONE SOURCE
Rosenberger OSI ensures for maximum operational reliability and performance for your data
center. By extraordinarily reliable components,
having passed strict quality assurance tests, by
well-founded know-how in consulting and short
reaction times. And by an excellent on site service you can rely on in every situation.

Pages 98101

18

ROSENBERGER OSI PRODUCT CATALOG

Top of Rack Cabling


Our innovative ready-to-use
PreCONNECT COPPER Trunks are
perfectly suited for routing above the
racks. The high degree of flexibility
allows for minimum bending radii.
Page 123

Pages 128133

INFRASTRUCTURE CABLING IN raised floors


With the PreCONNECT FIBER Trunks here a
Multi Jumper type Rosenberger OSI established
international standards. They are pre-terminated,
ready-to-use and form the heart of state-of-theart data center cabling.

ROSENBERGER OSI PRODUCT CATALOG

LOCAL DATA DISTrIBUTION


Patchcords at the patch panel
handle the local data distribution.
Also for this application our
components ensure the highest
reliability and operational security.
All standard types of fibers and
connectors are available, serial
number labels on both sides and
individual measurement reports
render our quality traceable.

19

application field Mobile Communication

MOBILE COMMUNICATION STANDARDS

ARE ALWAYS AHEAD OF TIME.

OUR PRODUCTS TOO.


20

ROSENBERGER OSI PRODUCT CATALOG

Telecommunication is one of the most dynamic


and innovative fields of operation world-wide.
Successful are only those cooperating with technology partners capable of keeping step with
the rapid development and providing competitive advantages, continuously. Like Rosenberger
OSI.

ROSENBERGER OSI PRODUCT CATALOG

PARTNER OF GLOBAL PLAYERS


We support the world-wide market leaders and
ensure their competitive position. Every year
all around the globe thousands of new antenna
masts are equipped with our Fiber to the Antenna
(FTTA) solutionsand they will set the standard
for the next decades.

21

application field Mobile Communication

FROM BASE STATION

TO THE ANTENNA:

A FEW METERS CAN BE CRUCIAL.

The place where billions of high-frequency signals turn into digital, cable-bound data streams
is the antenna mast. Right here, between base
station and antenna, the quality of the transmission between network and end-user is defined. Fiber to the Antenna (FTTA) solutions by
Rosenberger OSI ensure that not only current
but also standards to be expected in the future
will be met without compromise.

FTTA-SYSTEMS FOR ALL APPLICATIONS


Even if all mobile antenna masts serve the same
purpose in the end: in practice different cabling
schemes and architectures are applied. For each
of these approaches we provide the proper products and with our parent company Rosenberger
complete ready-to-connect packages including
all required ancillary equipment and mounting
material. Just as the carriers do expect from a
future-proof system supplier.

Page 168

22

ROSENBERGER OSI PRODUCT CATALOG

CONNECTION of the TRANSMITTERS


Breakout cables connect the distribution box and the antenna. The so
called jumpers from Rosenberger
OSI are extremely robust and easy to
handle during the installation.
Pages 112

115

Pages 110/111

WEatherPROOF DISTRIBUTion BOX


In structured FTTA systems the multi-fiber trunk
cable is split into individual channels and routed
to the radio units via breakout cable. In case of
re-installation only the shorter breakout cables
have to be changed.

ROSENBERGER OSI PRODUCT CATALOG

ROBUST OUTDOOR TRUNK


This FTTA-Trunk is the longest
and most stressed cable at the
mast. Because of its large exposed surface the trunk must be
resistant against the most adverse
environmental influences. With
an operation temperature range
between -40 C up to +80 C
PreCONNECT FIBER Trunk
Outdoor withstands heat, cold
and extreme temperature changes
and belongs to the most robust
trunks on the market.

23

APPLICATION FIELD BROADCAST

LIVE AT THE SCENE.

WITH HIGH SPEED CABLING

by Rosenberger OSI.

24

ROSENBERGER OSI PRODUCT CATALOG

Modern media technology permits high-resolution motion pictures for almost all end devices.
And for sport events almost always live and in
real-time. Vast amounts of data must be processed on site in the mobile production unit and
delivered in the shortest time from the place of
origin to the consumers screen.

ROSENBERGER OSI PRODUCT CATALOG

MANY mating cycles, HARSH CONDITIONS


The special challenge for optical fiber cabling is
to be found in the incredible number of mating
cycles, the very complex connectors are subjected to. Above that consider the rough treatment
of cables on site. The conditions for which our
Heavy Duty Series are predestinated for.

25

APPLICATION FIELD BROADCAST

WHAT COUNTS ON THE LAWN ARE

PERFORMANCE, STRATEGY AND persistence,

JUST LIKE FOR CABLING.


Eight cameras, four stage boxes, one outside
broadcast truck: a typical setting for a larger
event such as this Bundesliga match. Not to be
forgotten: various monitors, microphones and
reporter booths. Each interface of this complex
network has to be connected to each other by
high-speed cables: fast, simple and absolutely
reliable. For extreme environmental conditions,
frantic activity and severe mech-anical strain
this definitely means a challenge.
COMPREHENSIVE PRODUCT PORTFOLIO
In our longtime cooperation with broadcasting
companies, system integrators and manufacturers of mobile production units a multitude
of cabling components was developed. Thus
we are able to cover almost every application.
Above that our customers appreciate the option
of individual customization, short delivery times
and efficient trainings.

Pages 108/109

26

ROSENBERGER OSI PRODUCT CATALOG

CAMERA CONNECTION
The hybrid Heavy Duty 600
connector enables for power supply
and data transport. With two, four
or six optical fibers and up to four
electrical contacts on the
customers demand.
Page 84

Page 62

STAGE BOXES AS INTERMEDIATE


DISTRIBUTor
These local intersections for attachment of e.g.
monitors and microphones are connected with
our mobile PreCONNECT FIBER Trunks. These
hermaphrodite Heavy Duty connectors permit
easy and direct connection from cable to cable.

ROSENBERGER OSI PRODUCT CATALOG

MOBILE PRODUCTION UNIT


This is where all signals converge,
are cut and edited, all before the
final stream is transmitted via satellite. Dependent upon vehicle size
the data initially run up to a patch
panel or directly to the editing
suite. Here our patchcords with
LC-Duplex connectors are applied,
especially.

27

APPLICATION FIELD Industrial

DUST, MECHANICAL STRAIN, EXPLOSION HAZARD.

THE PERFECT ENVIRONMENT FOR

ROSENBERGER OSI HEAVY DUTY.


28

ROSENBERGER OSI PRODUCT CATALOG

Optical fibers are generally considered susceptible to contamination and mechanical strain.
Anyone who has assured himself of the fragility
of a single optical fiber and specific attenuation
of a particle of dust knows the reason why.
Therefore we are really proud of the fact that
our products can also be found in mine shafts.

ROSENBERGER OSI PRODUCT CATALOG

FIBER OPTICS FOR THE INDUSTRY


Products that sustain such extreme conditions
can also cope with other harsh environments.
If on offshore platforms, military applications or
aviation: cabling by Rosenberger OSI is chosen
when high bandwidth and extraordinary robustness are required.

29

APPLICATION FIELD INDUSTRIAL

HERE it BECOMES EVIDENT WHO

REALLY MASTERS
FIBER OPTIC TECHNOLOGY.

Mining resources underground is a technological masterpiece. Remotely managed from


control centers on the surface several hundred
meters below highly complex mining systems
burrow through the ground under surveillance
of video cameras and extensive sensor systems.
Nowadays humans are rarely seen down there.
There is no need of vivid imagination to envision
the incredible forces and strains the cables and
connectors are exposed to.

CUSTOMER SPECIFIC HIGH-END TECHNOLOGY


Depending upon the type of natural resources,
the components have to be protected from
extreme influences in an appropriate manner.
Irrespective of what we are dealing with: acid
as for copper mining, salt as in potassium
mines, or the explosion hazards as in coal
mining. Due to our wide experience we can
offer and provide our customers individualized
end-to-end systems literally capable of facing all
challenges.

Page 85

30

ROSENBERGER OSI PRODUCT CATALOG

CONNECTION OF MINE
CONTROL ROOM
Specially adapted PreCONNECT
FIBER Trunks with singlemode
fibers ensure the vast amounts of
data are transported via many
kilometers as lossless as possible.
Pages 108/109

Pages 136/137

INDIVIDUALLY ADAPTED COMPONENTS


The already durable Heavy Duty connectors can
be armored with a steel shell for most extreme
mechanical strain just one of many possibilities of customer-specific adaption.

ROSENBERGER OSI PRODUCT CATALOG

EXPLOSION-PROOF
DISTRIBUTION BOXES
Underground, on the mining face,
within explosion-proof housings
the patch panels merge most
divers data and signal sources.
Inside, factory assembled splice
cassettes or patchcords are used.
The connector for the trunk on
the outside must withstand greatest loads.

31

EXPECT MORE THAN THE BEST PRODUCTS:

OUR SERVICES

Every system is only as strong as the weakest component. The significance of cabling in
data centers is frequently underestimated and regularly neglected during examination
of performance issues. That is why we support you during all phases of the project with
the practical experience of 20 years.

PHASE 1: DESIGN AND ENGINEERING


The closer data rates approach physical limits, the more
attention must be paid to the transmission links already
during the design phase of a data center. We can explain
how to avoid mistakes.

PAGE 36

PHASE 2: Labeling AND LOGISTICS


To ensure a clear view during installation despite the large
number of components we apply efficient tools for labeling,
handling and documentation. In practice this leads to significant time advantage and results in cost benefits.

PAGE 38

32

ROSENBERGER OSI PRODUCT CATALOG

PHASE 3: PROJECT MANAGEMENT


AND INSTALLATION
During the hot phase right before putting into service the infrastructure we keep cool and keep track of everything. On request we also coordinate the other trade work, performe the
complete installation and carry out the final measurements.

PAGE 40

PHASE 4: MAINTENANCE AND SUPPORT


If a data center does not or no longer yield the expected
overall performance one reason may be inadequate dimensioning or defect in cabling and connectors. We analyze and
resolve faults or errors and offer long-term support.

PAGE 42

ROSENBERGER OSI PRODUCT CATALOG

33

Services

CABLING CAN
BE A RATHER COMPLICATED AND DRY MATTER.

DONT WORRY:

WE TAKE CARE OF THAT.

34

ROSENBERGER OSI PRODUCT CATALOG

There are few technical areas with higher


complexity than modern data centers. For that
reason it is all the more crucial that the multitude of components is ideally matched to each
other. Not only the active technologies require
greatest diligence during the project planning.
Cabling plays a decisive role as well.

ROSENBERGER OSI PRODUCT CATALOG

In context with the ever increasing demand


for higher data rates the physical limits for the
transmission links are reached more and more
often. This must already be considered during
the fundamental design steps for the data center. Good, that we have so much experience
and practical know-how. This helps you to keep
relaxed and us, too.

35

Services

Joint consulting and diligent


planning are the core principles
of each project.

Phase 1:

PLANNING AND ENGINEERING


Depending on the starting position and the
environment the planning phase can differ
significantly with regard to dimensioning and
course of action. Which special conditions do
exist? Are we talking about expanding an existing data center or building a new one? While
e.g. the second case permits choice of topography to suit future demands without succumbing
to attenuation limits of the transmission links,
the first case requires consideration of the
status quo. This automatically demands taking
extensive critical inventory.

In any case its all about the most efficient cable


management between rooms and racks as
well as within the racks. For this consideration
of cable types and connectors, number of interfaces, type of cable routing Top of Rack or
raised floorand variant of racks and panels has
to be taken into account. Absolutely crucial is
the question of the desired degree of flexibility
and the necessary headroom for future data rate
requirements.
Among all these considerations we neither
loose track of the perspective nor the current
status of standards.

36

ROSENBERGER OSI PRODUCT CATALOG

CUSTOMIZED SOLUTIOnS
One of our special skills during project planning
is our ability to incorporate very special demands
and requirements. Here it pays off that we have
learned to combine the flexibility of mediumsized business with the decades of experience
in data center environments. Should individual
adaption or application specific development
be necessary the course of the project preparation, we offer different solutions and evaluate
costs and feasibility. To do so our engineering
team, customer service representatives and

ROSENBERGER OSI PRODUCT CATALOG

end-user work closely together to ensure the


fulfillment of all practical requirements to finally
achieve an optimal implementation.
In that way we were able to master a lot of special
challenges for our customers, which could be
solved with standard components. For example
racks with extremely small installation depth,
project specific switch cabling or special versions
of our PreCONNECT Trunks.

37

Services

Phase 2:

Labeling AND LOGISTICS

38

ROSENBERGER OSI PRODUCT CATALOG

Depending on the dimensions of a project the


number of products to be processed may be
very high and handling can be accordingly
complex. Thousands of connectors must be
plugged, hundreds of active and passive components connected, racks and rooms cabled.
Rosenberger OSI has developed intelligent
processes and tools which not only radically
simplify work on site but also ensure
retraceability of every single cable.
STRUCTURED PRODUCT INDEXES
According your briefing we set up extensive
listings containing all to be used cablings. These
represent the structure of your individual project
and picture the perfect base for bill of material
and subsequent data center documentation.
Upon request even successive serial numbers of
cables and trunks are already included to keep
installation as simple as possible. And above
that the direct link between each shipment and
packing unit is ensured under all circumstances.
IDENTIFICATION AND RETRACeABILITY
A key feature of the Rosenberger OSI logistic
system is the systematic and detailed product
labeling. Each packing unit is equipped with
a post-card sized, clearly legible label which
not only states the exact product and detailed
specification but also the order number with
associated barcode.
Even for the most voluminous projects this
ensures that every cable and every trunk can be
identified instantly without a time-consuming
search or opening the packages. But this is only
one of the reasons why we are the partner of
choice for projects with tight time horizon.

ROSENBERGER OSI PRODUCT CATALOG

The one-to-one assignment of serial numbers


has another decisive advantage: the retraceability back to production and delivery. Should
any unexpected defect or undesirable change
of product arise, the reason can be found at any
time.
HANDLING AND PACKAGING
Of course, each of our trunks is supplied with
comprehensive handling and installation information. To prove the excellent quality of each
of Rosenberger OSIs products the individual
measurement reports are included in the
shipment in hardcopy form or in case of larger
projects in electronical form. Because we meticulously measure each fiber and connector we
gather large amounts of data.
To ensure that between our quality assurance
test and the deployment of the cables no damage
of the products can arise, they are packaged
particularly sturdy and carefully. Trunks are delivered either in generously dimensioned boxes
or in case of longer lengths or higher fiber
counts on drums of cardboard or wood.

39

Services

40

ROSENBERGER OSI PRODUCT CATALOG

Phase 3:

PROJECT MANAGEMENT
AND INSTALLATION

During the implementation phase we assist in


project management and coordinate the other
parties involved in the infrastructure: energy
supply, security and cooling systems. Frequently
the structured cabling is already installed prior
to the installation of the active components.
A smooth interface has to be ensured.
Basically the question has to be faced which
ratio the splice-cabling will occupy. Nowadays
most bigger data centers are built with completely pre-terminated trunks and cables, e.g. our
PreCONNECT FIBER Trunks. The advantages
with respect to benefits in time and flexibility
are clearly visible. Nevertheless the splicing
technology can make sense for smaller data
centers or an interbuilding solution.

PreCONNECT
Cable Dividers
The robust PreCONNECT
divider heads can be
installed tool-free thanks to its
square interface.

ROSENBERGER OSI PRODUCT CATALOG

The Rosenberger OSI PreCONNECT


FIBER Trunks enable a rapid and easy
installation.

If desired we also can perform the installation


for you by our staff members with long-term
experience, versed with each detail and possible
source for error. We label all cable-ends and components compliant to your own system or in the
scope of our PreCONNECT IPS asset management.
After installing all components and as soon as
the complete infrastructure is accomplished, we
can perform detailed on site acceptance measurements with specific emphasis upon the core
parameters attenuation and reflection, on request. Because - in spite of meticulous quality
assurance tests during manufacturing only
a measurement in the real operation area can
ensure perfect performance.

Measurements at the
patch panel
In practice measurement data
are obtained and evaluated to
ensure the faultless and perfect
performance of all processes.

41

Services

Phase 4:

MAINTENANCE AND SUPPORT


Maybe it surprises you to learn that we, as a
supplier of high speed cabling, also offer service
all around maintenance and support. But our
decades of insight into the most diverse practical
scenarios reveal that right here a significant
demand exists for a well-founded support.
Frequently the influence of cabling on performance of the data center is underestimated
and that influence is constantly rising.
The goal of 100 Gigabit transmission as the next
step data rates of 400 or even 1,000 Gigabits are
already discussed. But for most installed cabling
infrastructures this is far beyond the possible.

When upgrading your data center Rosenberger


OSI can help with an initial estimation if the
existing infrastructure is still adequate or if it has
to be upgraded as well. If substantial measurements should be necessary we cooperate with
specialized partners. Based upon status quo and
performance targets we define the briefing for
the project planning (see pages 36/37).
In the scope of running data center maintenance we perform network analysis and quality
checks in form of microscopic examination of
fiber optical connectors. We measure attenuation
and reflection and detect fractures of the optical
fibers by the means of lasers. But also other possible causes of error are not neglected, such
as e.g. wrongly crossed cable strands. Defective
connectors or cables are replaced immediately.
Our well-based know-how in error analysis and
correction will soon pay off for you for the
short-term as well as the long-term perspective.

Cleaning of ferrule faces


is just as much part of maintenance
as the use of modern software for detection
of potential interferences of transmission
links.

42

ROSENBERGER OSI PRODUCT CATALOG

ROSENBERGER OSI PRODUCT CATALOG

43

TECHNOLOGY
The fiber optic technology evolves as fast as its market. As a leading company in
fiber optics, Rosenberger OSI consistently faces itself challenges, to achieve best
possible results.

PreCONNECT
More than 20 years ago our fiber optic technology
PreCONNECT already set the standards. The new
PreCONNECT generation again surpasses itself.

PAGE 48

SWITCH CABLING
Individual solutions for switches and routers in data centers:
with our know-how and the PreCONNECT FIBER Trunk Multi
Jumper we establish efficient switch-cabling for each network device.
PAGE 51

44

ROSENBERGER OSI PRODUCT CATALOG

LENS CONTACTS
Unsusceptible to dirt at variable working distance.
The technology of expanded beam connectors renders that
connector type a robust precision technology.
PAGE 52

contact

area

Angled Physical Contact (APC)


Low reflection connections and stable transmission paths:
high-grade connectors by Rosenberger OSI with angled
polished surfaces.
PAGE 53

LASER CONNECT HIGH POWER


Reliable high-performance technology of a new generation:
This laser connector with novel conic prism and total reflection
allows a power of up to 40 kW.
Page 54

ROSENBERGER OSI PRODUCT CATALOG

45

Technology

TECHNOLOGICAL LEAD IS a RESULT OF KNOWLEDGE

AND THE MOTIVATION

in ONLY ACCEPTing THE BEST.

46

ROSENBERGER OSI PRODUCT CATALOG

In times of a society aligned for communication


and information exchange the fiber optic technology increasingly gains importance. Growing
data volume requires higher transmission rates
and bandwidth and impose ever growing demands to material and engineering. The mission
of Rosenberger OSI is to determine the further

ROSENBERGER OSI PRODUCT CATALOG

development of fiber optic technology by innovative research and to consolidate its technological advantage consistently. This means to
us: promoting innovation, implementing stateof-the-art technology up to the limits of the
physically feasible.

47

Technology

application fields

Data Center
Mobile
Communication
Broadcast
Industrial

PreCONNECT
The Rosenberger OSI PreCONNECT cabling system consists of pre-connected loose tube cables
with up to 144 fibers called Trunk.
Already in 1991, as first company, Rosenberger
OSI introduced these innovative PreCONNECT
Trunks to the German market. Due to our longterm experience in the field of fiber optics and
the continuous further development of our
products, we still maintain an obvious technological advantage to our competitors.

Manufacturing of a PreCONNECT Cable Divider


Step where the fibers coming from the trunk-cable
are inserted into the fanouts.

48

ADVANTAGES OF PreCONNECT
TRUNKS AT A GLANCE:
Both cable ends are assembled with fiber
optic connectors on stepped fanout legs,
the fibers are measured in the factory.
Cables have robust cable dividers.
The standard coding resp. light propagation
of the legs is channelwise crossed (pairwise
flipped) for full-duplex systems A1 to B1, A2
to B2, etc.
Upon request we also manufacture the
PreCONNECT Trunks uncrossed (straight).
For secure installation the fiber optic connectors, fanouts and cable dividers are equipped
with tensile strength and crush resistant
installation tubes.
To accept the two factory assembled cable dividers, panels developed by Rosenberger OSI
are available with special square interfaces for
tool-free mounting of the cable dividers, for
tensile and torsion resistant installation of the
trunks.
The ready-to-use PreCONNECT Trunks result
in minimum installation time and permanent
reusability.

ROSENBERGER OSI PRODUCT CATALOG

PreCONNECT cable divider


The Rosenberger OSI PreCONNECT Cable
Dividers are one of the mechanically and thermally most robust cable furcations for loose
tube cables at smallest diameters.

THE PreCONNECT cable dividers:


The loose tube cables are molded by two component resin into the back part of the cable
divider and the individual fibers are inserted
into loose tube fanout legs.

Spliceless cable divider for isolation of fibers


of loose tube cables
Very robust against mechanical and thermal
influence and water-proof according to IP67
the optical fibers are perfectly protected
against harmful environmental influence.
The PreCONNECT Cable Divider is extremely
compact in relation to number of fibers.
Integrated interface for dust or waterproof
installation tubes (see below).
With square interfaces for tool-free installation
of PreCONNECT Cable Divider into panels by
Rosenberger OSI.

Integrated interface for installation tubes

Loose tube fanout legs


Fibers

Two component resin system

Square interfaces for installation of the cable divider

ROSENBERGER OSI PRODUCT CATALOG

49

Technology

ADVANTAGES COMPARED TO CONVENTIONAL


FIBER OPTIC SPLICE CABLING
LOW OVERALL COST
The overall expenses for all components such
as cable meters, pigtails, splice boxes, splice protection, splice holders and above all the time-,
personnel- and device-intensive splicing itself
are in general higher than for a PreCONNECT
Trunk.

LOW ATTENUATION AND REFLECTION


PreCONNECT is a splice-less connection. The
fibers of the cable are inserted into fanout legs
in the cable dividers and directly assembled
with optical connectors.

SAFETY
PreCONNECT Trunks are completely protected
against harmful environmental influences.
In contrast, the fibers in splice boxes, are subjected to air and can age (increased attenuation,
fiber fracture).

EASY TO MAINTAIN

INVESTMENT PROTECTION
PreCONNECT Trunks are reusable because they
can be re-installed easily.

MINIMUM INSTALLATION TIME


Very simple installation and acceptance test:
PreCONNECT Trunks only have to be laid
and the cable dividers and optical connectors
plugged within the housing.
PreCONNECT Trunks are pre-measured off
factory therefore after installation only Go/No
Go tests are required for detecting possible
damage during installation at all.
No expensive specialists or expensive special
equipment, e.g. splicing and measurement
devices required for installation.
Presence of installation personnel in security
relevant areas is reduced to a
minimum.

The robust fanout legs of PreCONNECT Cable


Dividers allow performing service tasks such as
cleaning of optical connectors in a much safer
way compared to spliced, bending-susceptible
fiber pigtails.

CONVENTIONAL SPLICE CABLING IN ECONOMIC COMPARISON


TO FACTORY ASSEMBLED PreCONNECT:
Work requirements for conventional splicing solution:
Cabling of 100 m, two technicians:
approx. 1 hour
Splicing and other tasks, measurement of 48 fibers,
two technicians, two splice units: approx. 8 hours


total: approx. 9 hours
Efforts for PreCONNECT:
Cabling of 100 m, two technicians: approx. 1 hour
Setting of connectors, installation of distribution
boxes and transmission test, two technicians:
approx. 0,75 hours
total approx. 1,75 hours

50

10 hrs.
9 hrs.
8 hrs.
7 hrs.

7,25 hrs.

6 hrs.

time saved

5 hrs.
4 hrs.
3 hrs.
2 hrs.
1 hr.

9 hrs.

1,75 hrs.

SPLICING

PreCONNECT

ROSENBERGER OSI PRODUCT CATALOG

application field

Data Center

SWITCH CABLING
In the recent last years the steadily rising packing
density in big switches and routers requires
individualized cabling solutions. For cabling of
units with high count of ports on smallest space
many important details must be considered, such
as later exchangeability of individual blades of a
fully cabled switch.
Rosenberger OSI looks back on 20 years of experience in data center cabling. During this time we
have developed various Best Practice cabling
solutions for many models and generations of
switches and routers.
PreCONNECT FIBER Trunks
Multi Jumper in use

Thanks to our know-how we make efficient


switch-cabling possible for all our customers, for
every network device and budget. With our
innovative and comprehensive product range
we are able to develop customized cabling solutions for specific requirements. Due to, together
with our customers, we design device and application specific solutions for big switches and
routers perfectly adapted to their application.
For implementation of your customized switch
cabling please contact us directly.
We are looking forward to your inquiry.

Custom cabling at a big data center switch

ROSENBERGER OSI PRODUCT CATALOG

51

Technology

APPLICATION FIELDS

Broadcast
Industrial
aviation
Medicine
harsh
environment

Lens-contact #12

LENS-CONTACTS
Lens-contacts are characterized by a special
connection technology which distinguishes itself from most other optical connector types by
its special performance: lens-contacts are not
sensitive to soiling and permit variable working
distance. For this reason they represent reliable
optical connection technology for harsh environments with high degree of environmental
influence.

Schematic cross-section of
lens-contact with beam path
marked in red.

The lens connector technology uses beam


expansion as main functional principle.
The light exiting from the end of the fiber
passes through a spherical lens and is expanded to a beam of a 100 to 200 times bigger
area. On the opposite side an identical lens
concentrates the incoming splayed beam back
to its original diameter and back into the fiber.
In the proper connector area the signal is
transferred by a comparably large area,
without contact of the end faces. This effectively results in a significantly increased
tolerance against dirt and reduces the
distance sensitivity.

Rosenberger OSI looks back on long-term experience in manufacturing of such precision


technology. Special know-how, state-of-the-art
production processes and uncompromising
quality assurance make our lens contacts stateof-the-art products at high level. Especially our
customers from industry and broadcasting
know and appreciate the performance and
durability of our lens-contacts where nothing
may be left to chance they rely on high end
technology by Rosenberger OSI.
Beam expansion inside the
connector

52

ROSENBERGER OSI PRODUCT CATALOG

application field

Mobile
Communication
Data Center

Angled Physical Contact (APC)


In optical fibers each fiber end causes reflections of coupled light that results in signal attenuation and degradation. Depending on the
quality of fiber polish and endface geometry
this causes aberrations with effects on data
transmission. The APC technology also called
High Return Loss (HRL) counters such interferences. This guarantees for low-reflection
connections and by this allows more stable
transmission paths especially for high data rates.

contact

area

FTTH Fiber to
the Home
harsh
environments

The fiber end is polished under a certain


angle usually 8.
Reflections forming at the end of the fiber
cannot spread anymore. Reflected light is decoupled from the contact surface of the fiber
and emitted into the fiber cladding.
The angled polish APC/HRL significantly
reduces the return loss and interference by
reflected signal components. The so-called
Signal to Noise Ration (SNR) is significantly
improved.
Since its foundation Rosenberger OSI produces
high quality connectors with angled polished
fiber end faces. Consequently that turns us into
one of the most experienced companies in the
field of fiber optics using APC/HRL technology.
Rosenberger OSI not only manufactures solid
ceramic connectors with APC faces but also
successfully uses this technology for hybrid
connectors of the Heavy Duty line. Above that
we continuously improve our quality assurance
and steadily optimize the production conditions
to fulfill the enhanced demands for diligence
and precision in manufacturing and quality
assurance processes.
At all times best prerequisites for manufacturing
our products according to the latest state-ofthe-art technology and highest level of quality.
In controlled manufacturing environments our
frequently trained specialists work on one specific
target: make the tried-and-true even better.

Ferrule with APC-end


example of Heavy Duty 600

ROSENBERGER OSI PRODUCT CATALOG

53

Technology

application field

Industrial

LASER CONNECT HIGH POWER

The Laser Connect High Power at work:


highest performance for laser welding and
cutting facilities

The manufacturing industry cannot be imagined


without laser welding. Frequently applications
with high laser power lead to unwanted side
effects, abrasion, loss of precision and finally
destruction of the connector. For this reason
Rosenberger OSI invented Laser Connect High
Power, an innovative system for the process of
beam transmission successfully dealing with
these complications.

Laser Connect High Power

54

ROSENBERGER OSI PRODUCT CATALOG

ADVANTAGES OF LASER CONNECT HIGH POWER AS OVERVIEW

THE NEW TYPE SPhERICAL LENS


The new conic prism attached at the connector
face utilizes the laser light to such optimal
degree (total reflection), that power of up to
40 kW become possible.
At the same time an efficient beam deflection
of badly coupled beams takes place, protecting
the cladding.
The technology of total reflection also avoids
excessive heating due to back reflections from
the work piece, precludes unstable focus and
results in higher tool life.

AN INNOVATIVE COOLING SYSTEM

Deficient coupling
Good coupling

An air-cooling system with high purity compressed air dissipates excess warmth from the
critical region at the fiber end and the connector side walls.
This additionally results in active cleaning of
the fiber surface and increases tool life.

BETTER BEAM QUALITY BY MODE


MIXER
Independent of the beam quality of the
launched laser light, the mode mixer permits
developing uniform emission properties on
the application side.
This way old weld seams are avoided.
Since 20 years Rosenberger OSI manu-factures
laser launch connectors used in industrial and medical applications. The experience and innovation
resources of our company specifically for the
field of laser technology now resulted in a highquality and performance oriented connector and
with which we have entered a new dimension.

Inside cool air-stream for cooling


of fiber chamber

The Laser Connect High Power: this is durable


and reliable high-tech for laser welding and cutting lines in expected Rosenberger OSI quality.

External cool air-stream of the


decoupling zone.

ROSENBERGER OSI PRODUCT CATALOG

55

56

ROSENBERGER OSI PRODUCT CATALOG

the products

in chapters

ROSENBERGER OSI PRODUCT CATALOG

connectors

60

assemblies

90

panels and Racks

138

accessories

182

57

the products

IN DETAILed OVERVIEW

connectors
Connectors
LC
62
MU 64
SC 66
E-2000TM/LSH
68
MTP/MPO
69
MT-RJ 70
FC 71
ST 72
DIN/LSA
73
Adapters 74
Optical Contacts
MINI Contact
DIN Contact
Expanded Beam Contact #5
Expanded Beam Contact #12
Optical Contact #16

76
77
78
79
80

Heavy Duty
Rosenberger Duplex Connector (RDC)
Rosenberger Quad Connector (RQC)
Heavy Duty 600
Heavy Duty 1000

82
83
84
85

Laser Connect
Laser Connect 100
Laser Connect High Power

86
88

Further Connector Types 89

assemblies
PreCONNECT Fiber
PreCONNECT Fiber Trunk
PreCONNECT Fiber Trunk Multi Jumper
PreCONNECT Fiber Breakout
PreCONNECT Fiber MTP Divider Cables (Harnesses)

Parallel Optics in the Data Center
PreCONNECT Fiber Trunk Mobile
PreCONNECT Fiber Trunk Outdoor
PreCONNECT Fiber Breakout Outdoor
PreCONNECT Fiber Cablebundle Outdoor
PreCONNECT Fiber Tower Multi-fiber System (TMFS)
PreCONNECT FIBER Accessories

92
94
98
102
104
106
108
110
112
116
117
118

PreCONNECT Copper
120
PreCONNECT Copper Trunk 122
PreCONNECT Copper Trunk ToR
123
PreCONNECT Copper Trunk Multi Jumper
124

58

Patchcords and Pigtails

126
Patchcords Fiber
128
Patchcords Copper
133
Pigtails 134
Factory Assembled Splice Cassettes
136

ROSENBERGER OSI PRODUCT CATALOG

panels and racks


panels

19 1 HU and 2 HU Distribution Panel


19 1 HU and 2 HU Splice Panel
19 3 HU Distribution Module Panel
19 3+1 HU Splice Module Panel
19 SMAP Distribution Panels
19 SMAP Splice Panels
19 SMAP Distribution Panels with MTP Modules
SMAP Panel Accessories
19 6 HU Distribution Module Panel
Mini Universal Box
Universal Box
Distribution Box Outdoor
Excess Fiber Cable Enclosure Outdoor
19 1 HU Panel Copper
19 1 HU SMAP Panel Copper
19 1 HU Distribution Panel Copper ToR

PANEL ACCESSORIES

Panel Accessories

Racks

172
174
178
180

Patch Location Rack

140
142
146
150
152
154
156
158
160
162
164
166
168
169
170
170
171

ACCESSORIES

Inspection and Cleaning Kit


Test Laser EV-3
Reel Cleaner
Click Cleaner
OTDR Measurement Fiber Case
Assembly Tools
Measurement Cables

184
185
185
185
186
187
188

MTP is a registered trademark of US-Conec Ltd.


E-2000TM is a registered trademark of Diamond S.A.

ROSENBERGER OSI PRODUCT CATALOG

59

60

ROSENBERGER OSI PRODUCT CATALOG

connectors

ROSENBERGER OSI PRODUCT CATALOG

61

connectors

LC
(PC 0 and APC 8)

LC-Compact

LC-Duplex

Mini-LC-Duplex

LC-Simplex

LC Adapter, further adapter types


see pages 74/75

APPLICATIONS

Properties

LAN
SAN and data center
MAN and WAN

Small Form Factor (SFF) single-fiber connector


Simplex and duplex
Latched push-pull locking mechanism: a latch has to be
pushed for unmating
APC version with angled polished ferrule surface (8)
Spring loaded ferrule, aligned in a slotted sleeve
Tuning possible
Mini-LC-Duplex with a reduced pitch of 5.25 mm available
indicated by a yellow clip

technical Data
STANDARD
Ferrule [mm]

1.25

Zirconia ceramic

INSERTION LOSS 1 [db], max.

0.15
0.3

Multimode Low Insertion Loss


Singlemode and multimode standard

20
45
55
70

Multimode PC
Singlemode PC
Singlemode UPC
Singlemode APC

-40 to +85

Dependent on cable type

RETURN LOSS 2 [db], min.

TEMPERATURE RANGE [C]


MATING CYCLES, min.
cable [mm]
STRAIN RELIEF [N], min.
COLOUR OF CONNECTOR BODY

62

IEC 61754-20

1000
0.9 - 3.0
70
Blue
Green
Black
Beige

Singlemode PC
Singlemode APC
Multimode 50 m
Multimode 62.5 m

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

connectors

Partnumbers
COMPONENTS
98 LCS 120-101
98 LCS 110-101
98 LCS 130-101
98 LCS 130-109
98 LCS 130-102

CONNECTOR BODY, SIMPLEX, CABLE TYPE


Singlemode PC,
blue
Singlemode APC, green
Multimode 50 m, black
Multimode 50 m, black, Low Loss Type
Multimode 62.5 m, beige

98 LCS 120-102
98 LCS 110-102
98 LCS 130-103
98 LCS 130-110
98 LCS 130-104

CONNECTOR BODY, DUPLEX, 2 x incl. CLIp


blue
Singlemode PC,
Singlemode APC, green
Multimode 50 m, black
Multimode 50 m, black, Low Loss Type
Multimode 62.5 m, beige

98 LCS 120-103
98 LCS 110-103
98 LCS 130-105
98 LCS 130-107
98 LCS 130-106

CONNECTOR BODY, MINI DUPLEX, 2 x incl. CLIP


Singlemode PC, blue
Multimode 50 m, black, Low Loss Type

98 LCS 120-104
98 LCS 130-108

CRIMP ringS [mm] 1.8


2.0 - 2.2
2.4 - 3.0

98 ZC 01-000
98 ZC 02-000
98 ZC 03-000

BOOT 0.9 mm
Black
Blue
Green
White

98 ZB 01-0B K
98 ZB 01-0BU
98 ZB 01-0GN
98 ZB 01-0WH

DIMENSIONS
31.8

BOOT 1.8 - 2.2 mm


Black
Blue
Green
White

98 ZB 02-0B K
98 ZB 02-0BU
98 ZB 02-0GN
98 ZB 02-0WH

BOOT 2.4 - 3.0 mm


Black
Blue
Green
White

98 ZB 03-0B K
98 ZB 03-0BU
98 ZB 03-0GN
98 ZB 03-0WH

CONNECTOR BODY, COMPACT


Singlemode PC,
blue
Singlemode APC, green
Multimode 50 m, black
Multimode 50 m, black, Low Loss Type
Multimode 62.5 m, beige

98 LCS 120-204
98 LCS 110-204
98 LCS 130-204
98 LCS 130-206
98 LCS 130-205

CRIMP ringS [mm] 2.4 - 3.0

98 ZC 04-000

BOOT for COMPACT


Black
Blue
Green
White
Red

98 ZB 04-0B K
98 ZB 04-0BU
98 ZB 04-0GN
98 ZB 04-0YE
98 ZB 04-0RD

ROSENBERGER OSI PRODUCT CATALOG

1
connectors

CONNECTOR BODY, SIMPLEX, BUFFERED FIBEr


blue
Singlemode PC,
Singlemode APC, green
Multimode 50 m, black
Multimode 50 m, black, Low Loss Type
Multimode 62.5 m, beige

49.5

6.25

63

connectors

MU
(PC 0 and APC 8)

MU-Simplex

MU APC
MU-Duplex-Horizontal

MU-Compact

APPLICATIONS

Properties

MU: Mobile communication WDM / DWDM systems


MAN and WAN
SAN and data center
MU APC: Mobile communication WDM / DWDM systems
MAN and WAN
CATV

Adapter, further
adapter types see
pages 74/75

Single-fiber connector
Simplex, duplex horizontal and vertical
Push-pull locking mechanism
APC-version with angled polished ferrule endfaces (8)
Spring loaded ferrule, aligned in slotted sleeve
Tuning possible

technical Data
Standard
Ferrule [mm]

1.25

Zirconia ceramic

INSERTION LOSS 1 [db], max.

0.15
0.3

Multimode Low Insertion Loss


Singlemode and multimode standard

20
45
55
70

Multimode PC
Singlemode PC
Singlemode UPC
Singlemode APC

-40 to +85

Dependent of cable type

RETURN LOSS 2 [db], min.

TEMPERATURE RANGE [C]


MATING CYCLES, min.
cable [mm]
STRAIN RELIEF [N], min.
COLOUR OF CONNECTOR BODY

64

IEC 61754-6
EN 50377-10

1000
0.9 - 3.0
70
Blue
Green
Black
Beige

Singlemode PC
Singlemode APC
Multimode 50 m
Multimode 62.5 m

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

connectors

Partnumbers
components

98 MUS 120-101
98 MUS 110-101
98 MUS 130-101
98 MUS 130-103
98 MUS 130-105

CONNECTOR BODY, Duplex


Singlemode PC,
blue
Singlemode APC, green
Multimode 50 m, black
Multimode 50 m, black, Low Loss Type
Multimode 62.5 m, beige

98 MUS 120-102
98 MUS 110-102
98 MUS 130-102
98 MUS 130-104
98 MUS 130-106

CONNECTOR BODY, Compact


Singlemode PC,
blue
Singlemode APC, green
Multimode 50 m, black, Low Loss Type
Multimode 62.5 m, beige

98 MUS 120-201
98 MUS 110-201
98 MUS 130-201
98 MUS 130-202

CRIMP ringS [mm]


1.6 - 2.1
2.8 - 3.5

98 ZC 06-000
98 ZC 07-000

BOOT, 0.9 mm FOR BUFFERED FIBER


Blue
Green
Black
Yellow
Red

98 ZB 07-0BU
98 ZB 07-0GN
98 ZB 07-0BK
98 ZB 07-0YE
98 ZB 07-0RD

BOOT, 1.6 - 2.1 mm CABLE


Blue
Green
Black
White

98 ZB 02-0BU
98 ZB 02-0GN
98 ZB 02-0BK
98 ZB 02-0WH

BOOT, 2.8 - 3.5 mm CABLE


Blue
Green
Black
Yellow
Red

98 ZB 04-0BU
98 ZB 04-0GN
98 ZB 04-0BK
98 ZB 04-0YE
98 ZB 04-0RD

1
Connectors

CONNECTOR BODY, Simplex


Singlemode PC,
blue
Singlemode APC, green
Multimode 50 m, black
Multimode 50 m, black, Low Loss Type
Multimode 62.5 m, beige

43

DIMENSIONS
6.6

3.95

4.4

43

54

14.1

3.95

4.4

54

ROSENBERGER OSI PRODUCT CATALOG

23.6

65

connectors

SC
(PC 0 - APC 8 and 9)

SC-Simplex
SC APC

Adapter, further

SC-Duplex

adapter types see


pages 74/75

APPLICATIONS

Properties

SC: LAN - cabling according to EN 50173


SAN and data center
SC APC: Mobile communication WDM / DWDM System
MAN and WAN
CATV

Single-fiber connector
Simplex and duplex
Push-pull locking mechanism
APC-version with angled polished ferrule endfaces (8 or 9)
Spring loaded ferrule, aligned in slotted sleeve
Tuning possible

technical Data
STANDARD
Ferrule [mm]

2.5

INSERTION LOSS 1 [db], max.

0.40

RETURN LOSS 2 [db], min.

TEMPERATURE RANGE [C]


MATING CYCLES, min.
cable [mm]
STRAIN RELIEF [N], min.
COLOUR OF CONNECTOR BODY

66

IEC 61754-4
EN 50377-4
Zirconia ceramic

20
45
55
65

Multimode PC
Singlemode PC
Singlemode UPC
Singlemode APC

-40 to +85

Dependent on cable type

1000
0.9 - 3.5
100
Blue
Green
Green, red boot
Black
Beige

Singlemode PC
Singlemode APC 8
Singlemode APC 9
Multimode 50 m
Multimode 62.5 m

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

connectors

Partnumbers
components

98 SCS 120-101
98 SCS 110-101
98 SCS 130-101
98 SCS 130-102

Duplex clip black

98 ZD 02-0BK

CRIMP ringS [mm]


2.1
2.8 - 3.5

98 ZC 05-000
98 ZC 04-000

BOOT, 0.9 mm BUFFERED Fiber


Blue
Green
Black
Yellow
Red

98 ZB 06-0BU
98 ZB 06-0GN
98 ZB 06-0BK
98 ZB 06-0YE
98 ZB 06-0RD

BOOT, 2.1 mm CABLE


Blue
Green
Black
Yellow
Red

98 ZB 05-0BU
98 ZB 05-0GN
98 ZB 05-0BK
98 ZB 05-0YE
98 ZB 05-0RD

BOOT, 2.8 - 3.5 mm CABLE


Blue
Green
Black
Yellow
Red

98 ZB 04-0BU
98 ZB 04-0GN
98 ZB 04-0BK
98 ZB 04-0YE
98 ZB 04-0RD

1
connectors

CONNECTOR BODY
blue
Singlemode PC,
Singlemode APC, green
Multimode 50 m, black
Multimode 62.5 m, beige

45.4

24.8

12.7

8.95

7.35

0.9

DIMENSIONS

56.1

9.6

27

ROSENBERGER OSI PRODUCT CATALOG

67

connectors

E-2000/LSH
(PC 0 and HRL/APC 8)

Adapter, further types


see pages 74/75

E-2000 Simplex

E-2000 Duplex-Compact

E-2000 Duplex

APPLICATIONS

Metal/Ceramic ferrule

Ceramic ferrule

Latched push-pull locking mechanism:


a lever has to be pressed for unmating
Automatically closing dust cover
APC-version with angled polished ferrule endface (8)
Spring loaded ferrule, aligned in slotted sleeve
Tuning possible
Version with active fiber core alignment available

LAN
MAN and WAN
Instruments

Properties
Single-fiber connector
Simplex, Duplex and Duplex-Compact

E-2000 is a registered trademark of Diamond S.A.

technical data
STANDARD
Ferrule [mm]

2.5

Zirconia ceramic
or metal/ceramic composite

INSERTION LOSS 1 [db], max.

0.25
0.40

Singlemode
Multimode

20
45
55
70

Multimode PC
Singlemode PC
Singlemode UPC
Singlemode APC

-40 to +85

Dependent on cable type

RETURN LOSS 2 [db], min.

TEMPERATURE RANGE [C]


MATING CYCLES, min.
Cable [mm]
STRAIN RELIEF [N], min.

COLOUR OF CONNECTOR BODY

PROTECTION CAP
Singlemode tuning
1

68

IEC 61754-15
EN 50377-8

1000
0.9 - 3.3

Diamond up to 3.5

100
Blue
Green
Black

Singlemode PC
Singlemode APC
Multimode 50 m + 62.5 m

Metal or plastics

Diamond metal only

Optional
Active fiber core alignment

Type R+M
Type Diamond

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

connectors

MTP/MPO

Multimode
male

MTP/MPO Adapter,
further adapter types
see pages 74/75

APPLICATIONs

Properties

SAN and data center


LAN

Multi-fiber connectivity system


Spring loaded ferrule, aligned by pins
4, 8, 12 or 24 fibers
Push-pull locking mechanism

1
connectors

Multimode
female

MTP is a registered trademark of US Conec Ltd.

technical data
standard
Ferrule [mm]
INSERTION LOSS 1 [db], max.

RETURN LOSS 2 [db], min.

TEMPERATURE RANGE [C]

IEC 61754-7
2.5 x 6.5

Precision plastic composite

0.60
0.35

Singlemode
Multimode

20
55

Multimode PC
Singlemode APC

-40 to +80

Dependent on cable type

MATING CYCLES, min.

1000

Cable [mm]

3
3x5

STRAIN RELIEF [N], min.


COLOUR OF CONNECTOR BODY

Round cable
Ribbon cable

70
Green
Black
Beige

Singlemode
Multimode 50 m (also OM3)
Multimode 62.5 m

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

69

connectors

MT-RJ

Male, 50 m

Female, 62,5 m

MT-RJ Adapter, further


adapter types see
pages 74/75

APPLICATIONS

Properties

LAN
SAN and data center

Small Form Factor (SFF) duplex connector


Latched push-pull locking mechanism:
a lever has to be pressed for unmating
Spring loaded ferrule, aligned by pins

Technical Data
STANDARD
Ferrule [mm]

2.5 x 4.5

Precision plastic composite

INSERTION LOSS 1 [db], max.

0,6

RETURN LOSS 2 [db], min.

20
35

Multimode PC
Singlemode PC

-40 to +80

Dependent on cable type

TEMPERATURE RANGE [C]


MATING CYCLES, min.
CABLE [mm]
STRAIN RELIEF [N], min.

COLOUR OF CONNECTOR BODY

70

IEC 61754-18

500
2,9
2 x 1.8

Ribbon cable
Mini-zipcord

70
Blue
Black
Beige

Singlemode
Multimode 50 m
Multimode 62.5 m

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

connectors

FC
(PC 0 and APC 8)

FC PC

FC APC

FC Adapter, further
adapter types see
pages 74/75

APPLICATIONs

Properties

Single-fiber connector
Screwed locking mechanism
Spring loaded ferrule, aligned in slotted sleeve
Tuning possible
Metal connector body

1
connectors

Mobile communication
MAN and WAN
Measurement tools
CATV

technical data
IEC 61754-13
EN 50377-2

FC PC
FC PC and FC APC

Ferrule [mm]

2.5

Zirconia ceramic

INSERTION LOSS 1 [db], max.

0.4

RETURN LOSS 2 [db], min.

20
45
55
65

Multimode PC
Singlemode PC
Singlemode UPC
Singlemode APC

-40 to +85

Dependent on cable type

STANDARD

TEMPERATURE RANGE [C]


MATING CYCLES, min.
CABLE [mm]

1000
0.9 - 3.0

STRAIN RELIEF [N], min.

100

SINGLEMODE TUNING

Optional

Fiber TYPES

9/125
50/125
62.5/125

Other fiber types on request

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

71

connectors

ST

Type: ceramic

ST Adapter, further
adapter types see
pages 74/75

Type: metal

APPLICATIONs

Properties

LAN
Not any longer recommended for cabling systems
according to ISO/IEC 11801 and EN 50173
Industry e.g. bus systems

Single-fiber connector
Simplex and duplex
Bayonet locking mechanism
Tuning possible
Metal connector body

Technical data
STANDARD
Ferrule [mm]

2.5

INSERTION LOSS 1 [db], max.

0.4

RETURN LOSS 2 [db], min.

20
40
45

Multimode PC
Singlemode PC
Singlemode UPC

-40 to +85

Dependent on cable type

TEMPERATURE RANGE [C]


MATING CYCLES, min.
cable [mm]
STRAIN RELIEF [N], min.
Fiber TYPES

72

IEC 61754-2, MIL-C-83522


IEC 60874-10
Metal or ceramic versions

1000
0.9 - 3.0
100
9/125
50/125
62,5/125
100/140
200/230

Other fiber types on request

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

connectors

DIN/LSA
(PC 0 APC 8)

DIN/LSA adapter,
further adapter types
see pages 74/75
Type 1: ceramic

Type Diamond: metal /ceramic

APPLICATIONs

Properties

Mobile communication
MAN and WAN
Measurement tools

1
connectors

Single-fiber connector
Screwed locking mechanism
Spring loaded ferrule, aligned in slotted sleeve
Tuning possible
Metal connector body

Technical data
STANDARD

IEC 61754-3,
former DIN 47256

Ferrule [mm]

2.5

INSERTION LOSS 1 [db], max.

0.4

RETURN LOSS 2 [db], min.

20
45
55

Multimode PC
Singlemode PC
Singlemode UPC

-40 to +85

Dependent on cable type

TEMPERATURE RANGE [C]


MATING CYCLES, min.
cable [mm]

Zirconia ceramic

1000
0.9 - 3.5

STRAIN RELIEF [N], min.

100

SINGLEMODE TUNING

Optional
Active fiber core alignment

Type standard
Type diamond

9/125
50/125
62.5/125

Other fiber types on request

Fiber TYPES

=according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

73

connectorsADAPTER

ADAPTER

Partnumbers
components

LC-Duplex,
SC footprint

LC-Duplex, standard type

LC-Quad adapter

MU-Duplex,
horizontal type

ADAPTER, LC-Duplex, SC-Footprint


blue
Monomode, PC,
green
Monomode, APC,
black
Multimode, 50 m,
Multimode, 50 m OM3, turkquoise
Multimode, 50 m OM4, purple
beige
Multimode, 62.5 m,

98 LCK8 LC-K00-bu
98 LCK8 LC-K00-gn
98 LCK8 LC-K00-bk
98 LCK8 LC-K00-tk
98 LCK8 LC-K00-vt
98 LCK8 LC-K00-be

ADAPTER, LC-Duplex, Norm-Type


blue
Monomode, PC,
green
Monomode, APC,
black
Multimode, 50 m,
Multimode, 50 m OM3, turkquoise
Multimode, 50 m OM4, purple
beige
Multimode, 62.5 m,

98 LCK8 LC-K01-bu
98 LCK8 LC-K01-gn
98 LCK8 LC-K01-bk
98 LCK8 LC-K01-tk
98 LCK8 LC-K01-vt
98 LCK8 LC-K01-be

ADAPTER, LC-Quad for 2 x DUPLEX CONNECTOR


Monomode, PC,
blue
green
Monomode, APC,
black
Multimode, 50 m,
Multimode, 50 m OM3, turkquoise
Multimode, 50 m OM4, purple
beige
Multimode, 62.5 m,

98 LCK7 LC-K00-bu
98 LCK7 LC-K00-gn
98 LCK7 LC-K00-bk
98 LCK7 LC-K00-tk
98 LCK7 LC-K00-vt
98 LCK7 LC-K00-be

ADAPTER, MU-Duplex, Horizontal-Type


Monomode, PC,
blue
Monomode, APC,
green
black
Multimode, 50 m,
Multimode, 50 m OM3, turkquoise
Multimode, 50 m OM4, purple
Multimode, 62.5 m,
beige

98 MUK8 MU-K01-bu
98 MUK8 MU-K01-gn
98 MUK8 MU-K01-bk
98 MUK8 MU-K01-tk
98 MUK8 MU-K01-vt
98 MUK8 MU-K01-be

Adapter with non-standard flange or with integrated protection shutter on request

74

ROSENBERGER OSI PRODUCT CATALOG

connectors adapter

Partnumbers
components

98 SCK7 SC-K00-bu
98 SCK7 SC-K00-gn
98 SCK7 SC-K00-be

ADAPTER, SC-DUPLEX, PLASTICS VERSION


Monomode, PC, blue
Monomode, APC, green
Multimode,
beige

98 SCK8 SC-K00-bu
98 SCK8 SC-K00-gn
98 SCK8 SC-K00-be

SC-Duplex,
metal version

SC-Duplex,
plastic version

ADAPTER, E-2000, Simplex


Monomode, PC, blue
Monomode, HRL, green
Multimode,
black

1
adapter

ADAPTER, SC-DUPLEX, METAL VERSION,


COLOUR CODED PLASTIC INSERT
Monomode, PC, blue
Monomode, APC, green
Multimode,
beige

E-2000 Simplex

ADAPTER, E-2000, Duplex


Monomode, PC, blue
Monomode, HRL, green
Multimode, PC black
ADAPTER, E-2000, Compact
Monomode, PC, blue
Monomode, HRL, green
Multimode, PC black

E-2000 Compact

ADAPTER, MTP/MPO
Multimode 50 m OM4, purple
Monomode a. Multimode, black

MTP/MPO

Other adapters, furthermore hybrid types to connect different connector systems on request.
MTP is a registered trademark of US Conec Ltd.

In addition to the listed product range, we provide further


adapter types, e.g. hybrid types, adapter for special
mounting or with integrated shutter.

ST

FC-PC for D-hole mounting

ROSENBERGER OSI PRODUCT CATALOG

Please contact us for technical data and details. We would be


pleased to assist you.

FC-PC, version with


rectangular flange

Hybrid adapter, ST-ESCON

75

ConnectorsOPTICAL CONTACTS

MINI CONTACT

APPLICATIONs

Properties

Communication electronics
Medical devices
Suitable for connections to modular boards or components in backplanes, also in combination with coaxial or
power contacts from Rosenberger.

Snap-on assembly (retension clip)


Disassembly with release tool
Hybrid connections by combination with coaxial or
power contacs

Technical Data
Ferrule [mm]

1.25

INSERTION LOSS 1 [db], max.

0.70

RETURN LOSS 2 [db], min.

Metal or zirconia ceramic

45

TEMPERATURE RANGE [C]

-40 to +85

Dependent on cable type

MATING CYCLES, min.

500

CABLE [mm]

0,9
1.7

Buffered fiber
Simplex cable

9/125
50/125
62.5/125

Other fiber types on request

Fiber TYPES

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

Partnumbers
CABLE TYPE
0.9 mm
0.9 mm
With customized fiber bore

Singlemode
PIN CONTACT

Singlemode
SOCKET CONTACT

MultiMode
PIN CONTACT

MultiMode
SOCKET CONTACT

98 MS 301-126

98 MK 301-126

98 MS 101-128

98 MK 101-128

98 MS 101-xxx

98 MK 101-xxx

xxx has to be replaced by the requested fiber guiding bore diameter

76

ROSENBERGER OSI PRODUCT CATALOG

ConnectorsOPTICAL CONTACTS

DIN CONTACT

APPLICATIONs

Properties

Snap-on assembly (retension clip)


Disassembly with release tool
Hybrid connections in combination with Rosenberger
coaxial or power contacs
Enables customized layouts even in small production series

Industry
Communication electronics
Medical devices
Use in connectors according to DIN EN 60603-2,
version M and D-Sub types
Suitable for connections to modular boards or components in backplanes, also in combination with coaxial or
power contacts from Rosenberger.

Ferrule [mm]
INSERTION LOSS 1 [db], max.

TEMPERATURE RANGE [C]

2.5

Metal or zirconia ceramic

0.7

Multimode

-40 to +85

Dependent on cable type

MATING CYCLES, min.

500

CABLE [mm]

0.9
2.2
2.9

Buffered fiber
POF cable
Simplex cable

50/125
62.5/125
200/230 HCS
POF 1 mm

Other fiber types on request

Fiber TYPES

OPTICAL CONTACTS

Technical data

= according to IEC 61300-3-4, method B against reference

Partnumbers
type

PIN CONTACT

SOCKET CONTACT

Zirconia ceramic ferrule


Metal ferrule
Fiber HCS 200/230 m
POF
Customized fiber bore

98 IS 601-127
98 IS 101-128
98 IS 101-235
98 IS 450-1060
98 IS 101-xxx

98 IK 601-127
98 IK 101-128
98 IK 101-235
98 IK 450-1060
98 IK 101-xxx

RELEASE TOOL

9 8 W 1 2 - I N S/2 0 0

xxx has to be replaced by the requested fiber guiding bore diameter

ROSENBERGER OSI PRODUCT CATALOG

77

connectors Optical contacts

EXPANDED BEAM CONTACT #5

APPLICATIONs

Properties

Less susceptible against contamination due to


expanded beam technology
Easy cleaning due to cover glass of fused silica
Compensation of tolerances and movements within the
connector by spring loaded front part
Integrated release ring for insertion and removal
without tool
Snap-on alignment sleeve

Industry
Offshore and mining
Broadcast
Aerospace technology
Use in ARINC 600 connectors
For circular and rectangular housings

Technical data
Ferrule [mm]

INSERTION LOSS 1 [db], typ.

1.0

TEMPERATURE RANGE [C]

-40 to +85

CABLE [mm]

0.9 - 3.0

Fiber TYPES

50/125
62.5/125

78

Lensed ferrule

Dependent on cable type

= according to IEC 61300-3-4, method B against reference

ROSENBERGER OSI PRODUCT CATALOG

connectors Optical contacts

EXPANDED BEAM contact #12

APPLICATIONs

Properties

Very robust
Low susceptibility for contamination
Insertion and removal with standard tools for #12

1
optical contacts

Industry
Medical devices
Offshore and mining
Broadcast
For circular connectors according to MIL-DTL-38999

Technical data
SPECIFICATION

Compatible with MIL-DTL-38999

For use in cavities #12

Ferrule [mm]

2.3

Lensed ferrule

INSERTION LOSS 1 [db], typ.

1.5

TEMPERATURE RANGE [C]

-40 to +85

cable [mm]

0.9 - 2.0

Fiber TYPES

50/125
62.5/125

Dependent on cable type

= according to IEC 61300-3-4, method B against reference

Partnumbers
INSERTION TOOL

98 W 12-S12/100

REMOVAL TOOL

98 W 12-S12/200

ROSENBERGER OSI PRODUCT CATALOG

79

connectors Optical contacts

OPTICAL CONTACT #16

APPLICATIONs

Properties

Industry
Aerospace technology
Medical devices

Modular system for design of customized contact layouts


Pin and socket contacts compatible with
MIL-PRF-29504/4 and /5
Suitable for circular connectors according to
MIL-DTL-38999 with cavities #16

Technical data
STANDARD

Ferrule [mm]

1.58

Zirconia ceramic

INSERTION LOSS 1 [db]

0.7

Typ.

-40 to +85

Dependent on cable type

TEMPERATURE RANGE [C]

cable [mm]

0.9 - 2.0

Fiber TYPES

9/125
50/125
62.5/125

80

Compatible with
MIL-PRF-29504/4 and /5

= according to IEC 61300-3-4, method B against reference

ROSENBERGER OSI PRODUCT CATALOG

connectors Optical contacts

DIMENSIONS

3.3

1
optical contacts

1.59

23.4

3.3

2.9

32

Partnumbers
CABLE TYPE

PIN CONTACT

SOCKET CONTACT

1.1 mm singlemode

98 PS 302-126

98 PK 302-126

to 2.1mm Singlemode

98 PS 303-126

98 PK 303-126

1.1 mm multimode

98 PS 602-127

98 PK 602-127

to 2.1mm multimode

98 PS 603-127

98 PK 603-127

POF 980/1000/2.2

98 PS 450-1060

98 PK 450-1060

INSERTION TOOL

98 W 12-S16/100

REMOVAL TOOL

98 W 12-S16/200

POLISHING Tool

98 W 008-000

ROSENBERGER OSI PRODUCT CATALOG

81

connectors Heavy Duty

Rosenberger Duplex Connector (RDC)

APPLICATIONs

Properties

Robust 2 fiber connector with screwed locking mechanism


Components of the N coaxial connector according to
MIL-PRF-39012 enable a conversion within the standard
panel cutout.
Captive protection cap available

Mobile communication
Broadcast
Outdoor areas
Harsh environment

Technical Data
Ferrule [mm]
INSERTION LOSS 1 [db], max.
RETURN LOSS 2 [db], min.

Zirconia ceramic

0.50
50

Singlemode

TEMPERATURE RANGE [C]

-40 to +125

Dependent on cable type

INGRESS PROTECTION GRADE

IP67

IEC 60529

MATING CYCLES, min.

1000

CABLE [mm]
Fiber TYPES

82

2 x 1.25

4-7
1.7 or 2.1

(Mini) breakout
Simplex cable

9/125
50/125
62.5/125

Other fiber types on request

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

Connectors Heavy Duty

Rosenberger Quad Connector (RQC)

APPLICATIONs

Properties

Robust 4 fiber connector with screwed locking mechanism


Components of the N coaxial connector according to
MIL-PRF-39012 enable a conversion within the standard
panel cutout.
Captive protection cap available

Mobile communication
Broadcast
Outdoor areas
Harsh environment

Heavy Duty

Technical Data
Ferrule [mm]
INSERTION LOSS 1 [db], max.
RETURN LOSS 2 [db], min.

4 x 1.25

Zirconia ceramic

0,50
50

Singlemode

-40 to +125

Dependent on cable type

INGRESS PROTECTION GRADE

IP67

IEC 60529

MATING CYCLES, min.

1000

Cable [mm]

4-7
1.7

(Mini) breakout
Simplex cable

9/125
50/125
62.5/125

Other fiber types on request

TEMPERATURE RANGE [C]

Fiber TYPES

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

83

connectors Heavy Duty

Heavy Duty 600

APPLICATIONs

Properties

Broadcast, e.g. HDTV camera systems


Hybrid connection to distribution points
Mining

Hermaphrodite 2 identical interfaces can be connected


together without further accessories
2, 4 or 6 fibers and up to 4 electrical contacts, singlemode
ferrules also available as APC (8) type

Technical data
Ferrule [mm]
ELECTRICAL CONTACTS

Zirconia ceramic

2 x 680V, 10A
2 x 60V, 1A

Dependent on configuration

OPTICAL INSERTION LOSS 1 [db], max.

0,6

RETURN LOSS 2 [db], min.

20
45
65

Multimode PC
Singlemode PC
Singlemode APC

TEMPERATURE RANGE [C]

-40 to +85

Dependent on cable type

INGRESS PROTECTION GRADE

IP67

IEC 60529

MATING CYCLES, min.

5000

Cable [mm]
Fiber TYPES

84

2/4/6 x 2.5

6.0 - 12.0
1.7 - 2.2

Cable connector
Connecting cables

9/125
50/125
62.5/125

Other fiber types on request

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

connectorsHeavy Duty

Heavy Duty 1000

Properties

Broadcast
Hybrid connector for test bed
Mining and offshore

Hermaphrodite - 2 identical interfaces can be connected


together without further accessories
12 fibers, singlemode ferrules also available as APC (8) type
Option for 2 electrical contacts and grounding contact
Housing in metal or plastic material

Heavy Duty

APPLICATIONs

technical Data
Ferrule [mm]

12 x 2.5

Zirconia ceramic

ELECTRICAL CONTACTS

2 x 1.5

Optional
Grounding contact

OPTICAL INSERTION LOSS 1 [db], max.

0.6

RETURN LOSS 2 [db], min.

20
45
65

TEMPERATURE RANGE [C]

-40 to +60 (in operation)


-40 to +85 (storage)

INGRESS PROTECTION GRADE

IP67

MATING CYCLES, min.

1000

CABLE [mm]
Fiber TYPES

Multimode PC
Singlemode PC
Singlemode APC
Dependent on cable type
IEC 60529

6.0 - 16.0
1.7 - 2.2

Cable connector
Connecting cables

9/125
50/125
62.5/125

Other fiber types on request

= according to IEC 61300-3-4, method B against reference, 2 = according to IEC 61300-3-6, method 1 against reference

ROSENBERGER OSI PRODUCT CATALOG

85

connectors Laser connect

Laser COnnect 100

APPLICATIONs

Properties

Medical and industrial laser systems


Laser launch in sensor systems
Measurement tools

Compatible to F-SMA
Suitable for laser launch and emission within the medium
power range due to freestanding fiber
Adaption to various fiber, buffer and cable diameters by
modular connector system and large accessory range.
Easy handling with non-slip coupling nut
Long version enables to connect deep coupling lenses
Documentation of beam characteristics on request
Plug-and-play cable assemblies available

technical Data
Ferrule [mm]

fiber guiding bore [m]

CONNECTOR LENGTH WITHOUT BOOT [mm]


Long version
Short version
Mini version

TEMPERATURE RANGE [C]

STRAIN RELIEF, max. [N]

MATERIALS
Ferrule
Connector body
Protection cap

86

3.17

100 - 1100

45
30
22

-25 to +150

Dependent on fiber/cable type

100

Dependent on fiber type and


assembly method

Metal (suitable for sterilising)


Metal (suitable for sterilising)
Polyethylene or PEEK (suitable for sterilising)

ROSENBERGER OSI PRODUCT CATALOG

ConnectorsLaser connect

Partnumbers
COMPONENT
98 FS 100 - xxx / 50

SCREWED PROTECTION CAP


Suitable for sterilising

98 FS 100 - xxx / 30

MINI Connector

98 FS 201 - xxx

SHORT Connector

98 FS 203 - xxx

LONG Connector

98 FS 205 - xxx

CLAMP [mm]
0.45
0.52
0.75
1.00
1.30
1.50

98 LSZK / 0450
98 LSZK / 0520
98 LSZK / 0750
98 LSZK / 1020
98 LSZK / 1300
98 LSZK / 1500

FIXING SCREW [mm]


0.60
0.90
1.50

98 LS Z6 / 0600
98 LS Z6 / 0900
98 LS Z6 / 1500

BOOT [mm]
0.90
2.10
2.90

98 Z 108 SW
98 Z 107 SW
98 Z 106 SW

FLANGE RECEPTACLE

98 LK 110

JAM NUT RECEPTACLE

98 LK 100

1
Laser connect

PROTECTION CAP

All dimensions in [mm]


xxx has to be replaced by the requested fiber guiding bore diameter

ROSENBERGER OSI PRODUCT CATALOG

87

Connectors Laser connect

Laser COnnect High Power

APPLICATIONs

Properties

High power up to 40 KW with a new conic prism


and utilization of total reflection
Protection of fiber cladding by deflection of inoperative
radiation
Enhanced endurance by high purity air cooling and active
cleaning of the fiber surface
Integrated mode scrambler to prevent bad welding points

Industrial laser systems


High power laser launch
Laser machining
Welding robots

technical data
Interface

SUITABLE Fiber TYPES

Core- 200, 400, 600 m

COOLING SYSTEM

Air and water cooling

OVERALL LENGTH

approx. 240 mm

Max. DIAMETER

approx. 50 mm

RANGE OF ASSEMBLY LENGTH

SAFETY SYSTEM

88

LLK-B or LLK-D

Other on request

5 - 100 m

Fiber break detection with test impedance

According to German automotive standard

ROSENBERGER OSI PRODUCT CATALOG

connectors FURTHER CONNECTOR TYPES

FURTHER CONNECTOR TYPES

ESCON

F-SMA
(acc. to IEC 61754-22)

In addition to the listed product line, we provide a range of


further connectors. They are produced or assembled
according to the same high quality standards.

HEAVY DUTY SC-RJ

FDDI

On request, we are able to customize connectors to meet


particular categories or specifications.

1
Laser connect / FURTHER CONNECTOR TYPES

Please contact us for technical data and details. We would


be pleased to assist you.

ROSENBERGER QUALITY SIGNET

This label guarantees Rosenberger Quality without compromise.


Connectors produced by Rosenberger can be recognized by
the RT (Rosenberger Tittmoning) stamp. With each product,
you decide for cabling competence on the highest level:
powerfull and endurable solutions of the Rosenberger group.

ROSENBERGER OSI PRODUCT CATALOG

89

90

ROSENBERGER OSI PRODUCT CATALOG

assemblies

ROSENBERGER OSI PRODUCT CATALOG

91

PreCONNECT Fiber

92

ROSENBERGER OSI PRODUCT CATALOG

Assemblies: PreCONNECT Fiber

Our PreCONNECT FIBER products present holistic solutions for structured fiber optic cabling.
Whether it is in data centers, industry, mobile
communications or broadcast Rosenberger OSI
offers perfectly matching components for each
application environment.

ROSENBERGER OSI PRODUCT CATALOG

Fiber optic technology was and will be forever


our core competence. From the classical
PreCONNECT FIBER Trunk over Parallel Optics
high speed links or customized special requirements with each PreCONNECT FIBER product
from Rosenberger OSI you decide for 20 years of
know how and outstanding quality.

93

assemblies PreCONNECT Fiber

PreCONNECT Fiber Trunk

Leg lengths on both sides stepped acc. to table page 95,


suited for application in distribution panels

APPLICATIONS

CONNECTORS

Infrastructure cabling of data centers, office buildings and


campus cabling

With all standard connectors available,


simplex as well as duplex versions

PROPERTIES

Optional

See technology description on pages 48 50


Both sides factory assembled with FO connectors
Standard light propagation channelwise crossed
(pairwise flipped)
Cable length up to 2,000 m, longer on request

LENGTH DEFINITION
Order length: length between the connectors at the longest legs at both sides (not between the cable dividers)
Length tolerances:
up to 10 m
= +/- 50 cm
11 m to 30 m
= +/- 100 cm
31 m to 100 m = +/- 150 cm
longer than 100 m = +/- 2 %
Leg lengths on both sides stepped acc. to table page 95,
suited for application in distribution panels

Cable with increased tensile strength and crush resistance


Cable with special armoring
Hybrid cable with different types of fiber
Hybrid connector assembling
Single-sided factory assembled
OTDR measured with measurement report
Return loss (RL) measurement

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels behind both cable dividers
Dependent on the length as cable ring, on cardboard
or wooden drum

Installation Tube Indoor,


IP50 dust-proof

CABLE TYPES
With all standard loose tube cables up to 144 fibers
available
Cable data sheets on request

FIBER TYPES
With all standard fiber types available
Fiber data sheets on request

94

Installation Tube Outdoor,


IP67 water-proof

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Fiber

TECHNICAL DATA PreCONNECT Fiber Trunks


NUMBER OF FIBERS

12

16

24

36

48

72

96

144

85-100

65-100

65-95

65-94

65-100

65-90

65-98

65-90

95-110

95-125

DIAMETER INSTALLATION
TUBE [mm] approx.

28

28

28

35

35

60

60

60

75

75

MAX. TENSILE STRENGTH


INSTALLATION TUBE [N]

600

600

600

600

600

600

600

600

600

600

CRUSH RESISTANCE INSTALLATION


TUBE [N/cm]

30

30

30

30

30

30

30

30

30

30

LEG LENGTH STEPPED [cm] approx.

PreCONNECT Fiber Trunk


Efficiency Indoor Cable with
Mini Loose Tubes
Cable type I-B(ZN)BH 6 x 12

TECHNICAL DATA cable type I-B(ZN)BH n x m


CABLE DESIGN

STRANDED MINI LOOSE TUBES

36

48

72

96

144

OUTER- [mm]

8.4

9.4

11.4

MAX. tensile strength [N]

3000

3000

3000

3000

3000

MAX. CRUSH RESISTANCE [N/dm]

1000

1000

1000

1000

1000

MIN. BENDING RADIUS [mm] static



dynamic

80
120

80
120

84
126

94
141

114
171

FIRE LOAD [MJ/m]

0.69

0.69

0.73

0.92

1.43

2
PreCONNECT FIBER

NUMBER OF FIBERS, max.

COMPARISON MATRIX CABLE PROPERTIES U-DQ(ZN)BH vs. I-B(ZN)BH see page 101.

PARTNUMBERS
NUMBER OF FIBERS /
CONNECTORS

OS2
9/125

OM3
50/125

OM4
50/125

36

LC-Compact
MU-Duplex-Horizontal
MTP 12-female

024A0100 G657 A
024A0110 G657 A
024A0130 G657 A

024A0101 OM3
024A0111 OM3
024A0131 OM3

024A0101 OM4
024A0111 OM4
024A0131 OM4

48

LC-Compact
MU-Duplex-Horizontal
MTP 12-female

024A0102 G657 A
024A0112 G657 A
024A0132 G657 A

024A0103 OM3
024A0113 OM3
024A0133 OM3

024A0103 OM4
024A0113 OM4
024A0133 OM4

72

LC-Compact
MU-Duplex-Horizontal
MTP 12-female

024A0104 G657 A
024A0114 G657 A
024A0134 G657 A

024A0105 OM3
024A0115 OM3
024A0135 OM3

024A0105 OM4
024A0115 OM4
024A0135 OM4

96

LC-Compact
MU-Duplex-Horizontal
MTP 12-female

024A0106 G657 A
024A0116 G657 A
024A0136 G657 A

024A0107 OM3
024A0117 OM3
024A0137 OM3

024A0107 OM4
024A0117 OM4
024A0137 OM4

144

LC-Compact
MU-Duplex-Horizontal
MTP 12-female

024A0108 G657 A
024A0118 G657 A
024A0138 G657 A

024A0109 OM3
024A0119 OM3
024A0139 OM3

024A0109 OM4
024A0119 OM4
024A0139 OM4

Other fiber types, connector types and numbers of fibers on request. MTP is a registered trademark of US-Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

95

assemblies PreCONNECT Fiber

PreCONNECT Fiber Trunk


Universal Cable with Loose Tube Design

Cable type U-DQ(ZN)BH 24

Cable type U-DQ(ZN)BH 6 x 12

TECHNICAL DATA cable type U-DQ(ZN)BH n x m


CABLE DESIGN

CENTRAL LOOSE TUBE

STRANDED LOOSE TUBES

NUMBER OF FIBERS, max.

12

24

36

48

72

96

144

OUTER- [mm]

7.5

12.5

12.5

13.4

14.4

17.7

MAX. Tensile strength [N]

1750

1750

6000

6000

6000

6000

6000

MAX. CRUSH RESISTANCE [N/dm]

1500

1500

3000

3000

3000

3000

3000

MIN. BENDING RADIUS [mm] static



dynamic

105
140

115
150

190
250

190
250

200
270

215
290

270
355

FIRE LOAD [MJ/m]

0.71

0.79

3.1

3.1

3.2

3.4

4.5

COMPARISON MATRIX CABLE PROPERTIES U-DQ(ZN)BH vs. I-B(ZN)BH see page 101.

PARTNUMBERS
NUMBER OF FIBERS /
CONNECTORS

96

OS2
9/125

OM3
50/125

OM4
50/125

NUMBER OF FIBERS /
CONNECTORS

OS2
9/125

OM3
50/125

OM4
50/125

SC- Duplex
LC- Compact
MU- Duplex-Horizontal
E-2000 Simplex1 HRL

031A1501 031A1601 OM3 031A1601 OM4


031A1210 031A1212 OM3 031A1212 OM4
031A2001 031A2011 OM3 031A2011 OM4
031A1011

SC- Duplex
LC- Compact
36 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

031A1507
031A1802
031A2006
031A0913
031A0998

031A1607 OM3
031A1812 OM3
031A2016 OM3
031A0923 OM3

031A1607 OM4
031A1812 OM4
031A2016 OM4
031A0923 OM4

SC- Duplex
LC- Compact
MU- Duplex-Horizontal
E-2000 Simplex1 HRL

031A1503 031A1603 OM3 031A1603 OM4


031A0920 031A0921 OM3 031A0921 OM4
031A2002 031A2012 OM3 031A2012 OM4
031A1012

SC- Duplex
LC- Compact
48 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

031A1508
031A1803
031A2007
031A0915
031A1016

031A1608 OM3
031A1813 OM3
031A2017 OM3
031A0925 OM3

031A1608 OM4
031A1813 OM4
031A2017 OM4
031A0925 OM4

SC- Duplex
LC- Compact
12 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

031A1504
031A1800
031A2003
031A0912
031A1013

SC- Duplex
LC- Compact
72 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

031A1509
031A1804
031A2008
031A0917
031A1017

031A1609 OM3
031A1814 OM3
031A2018 OM3
031A0927 OM3

031A1609 OM4
031A1814 OM4
031A2018 OM4
031A0927 OM4

SC- Duplex
LC- Compact
16
MU- Duplex-Horizontal
E-2000 Simplex1 HRL

031A1505 031A1605 OM3 031A1605 OM4


031A1818 031A1220 OM3 031A1220 OM4
031A2004 031A2014 OM3 031A2014 OM4
031A1014

SC- Duplex
LC- Compact
24 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

031A1506
031A1801
031A2005
031A0914
031A1015

031A1604 OM3
031A1810 OM3
031A2013 OM3
031A0922 OM3

031A1606 OM3
031A1811 OM3
031A2015 OM3
031A0924 OM3

031A1604 OM4
031A1810 OM4
031A2013 OM4
031A0922 OM4

031A1606 OM4
031A1811 OM4
031A2015 OM4
031A0924 OM4

031A1805 031A1815 OM3 031A1815 OM4


LC- Compact
96 MU- Duplex-Horizontal 031A1999 031A1998 OM3 031A1998 OM4
MTP 12-female
031A0916 031A0926 OM3 031A0926 OM4
031A1806 031A1816 OM3 031A1816 OM4
LC- Compact
144 MU- Duplex-Horizontal 031A2009 031A2019 OM3 031A2019 OM4
MTP 12-female
031A0918 031A0928 OM3 031A0928 OM4
= Type R+M with zirconia ceramic ferrule.
APC and HRL connectors with 8 angled ferrule endfaces.
Other fiber types, connector types and numbers of fibers on request. MTP is a
registered trademark of US-Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Fiber

PreCONNECT Fiber Trunk


Outdoor Cable with Loose Tube Design

Operating temperature range: -25 C to +70 C,


for robust outdoor applications see
PreCONNECT FIBER Trunk Outdoor pages 110/111

Cable type A-DQ(ZN)B2Y 24

Cable type A-DQ(ZN)B2Y 6 x 12

TECHNICAL DATA Cable type A-DQ(ZN)B2Y n x m


CENTRAL LOOSE TUBE

STRANDED LOOSE TUBES

NUMBER OF FIBERS, max.

12

24

36

48

72

96

144

outer- [mm]

7.5

11.4

11.4

12.3

13.7

17

MAX. Tensile strength [N]

1750

1750

4000

4000

4000

4000

4000

MAX. CRUSH RESISTANCE [N/dm]

1500

1500

3000

3000

3000

3000

3000

MIN. BENDING RADIUS [mm] static



dynamic

140
185

145
195

170
230

170
230

185
245

205
275

255
340

FIRE LOAD [MJ/m]

1.1

1.2

3.1

3.1

3.2

3.4

4.5

PARTNUMBERS
NUMBER OF FIBERS /
CONNECTORS

OS2
9/125

OM3
50/125

OM4
50/125

NUMBER OF FIBERS /
CONNECTORS

OS2
9/125

OM3
50/125

OM4
50/125

SC- Duplex
LC- Compact
MU- Duplex-Horizontal
E-2000 Simplex1 HRL

010A1501 010A1601 OM3 010A1601 OM4


010A2081 010A2082 OM3 010A2082 OM4
010A2001 010A2011 OM3 010A2011 OM4
010A1011

SC- Duplex
LC- Compact
36 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

010A1507
010A1802
010A2006
010A0913
010A0998

010A1607 OM3
010A1812 OM3
010A2016 OM3
010A0923 OM3

010A1607 OM4
010A1812 OM4
010A2016 OM4
010A0923 OM4

SC- Duplex
LC- Compact
MU- Duplex-Horizontal
E-2000 Simplex1 HRL

010A1503 010A1603 OM3 010A1603 OM4


010A0920 010A0921 OM3 010A0921 OM4
010A2002 010A2012 OM3 010A2012 OM4
010A1012

SC- Duplex
LC- Compact
48 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

010A1508
010A1803
010A2007
010A0915
010A1016

010A1608 OM3
010A1813 OM3
010A2017 OM3
010A0925 OM3

010A1608 OM4
010A1813 OM4
010A2017 OM4
010A0925 OM4

SC- Duplex
LC- Compact
12 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

010A1504
010A2079
010A2003
010A0912
010A1013

SC- Duplex
LC- Compact
72 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

010A1509
010A1804
010A2008
010A0917
010A1017

010A1609 OM3
010A1814 OM3
010A2018 OM3
010A0927 OM3

010A1609 OM4
010A1814 OM4
010A2018 OM4
010A0927 OM4

SC- Duplex
LC- Compact
16
MU- Duplex-Horizontal
E-2000 Simplex1 HRL

010A1505 010A1605 OM3 010A1605 OM4


010A1818 010A1819 OM3 010A1819 OM4
010A2004 010A2014 OM3 010A2014 OM4
010A1014

SC- Duplex
LC- Compact
24 MU- Duplex-Horizontal
MTP 12-female
E-2000 Simplex1 HRL

010A1506
010A2077
010A2005
010A0914
010A1015

ROSENBERGER OSI PRODUCT CATALOG

010A1604 OM3
010A2080 OM3
010A2013 OM3
010A0922 OM3

010A1606 OM3
010A2078 OM3
010A2015 OM3
010A0924 OM3

010A1604 OM4
010A2080 OM4
010A2013 OM4
010A0922 OM4

010A1606 OM4
010A2078 OM4
010A2015 OM4
010A0924 OM4

2
PreCONNECT FIBER

CABLE DESIGN

010A2075 010A2076 OM3 010A2076 OM4


LC- Compact
96 MU- Duplex-Horizontal 010A1999 010A1998 OM3 010A1998 OM4
MTP 12-female
010A0916 010A0926 OM3 010A0926 OM4
010A1806 010A1816 OM3 010A1816 OM4
LC- Compact
144 MU- Duplex-Horizontal 010A2009 010A2019 OM3 010A2019 OM4
MTP 12-female
010A0918 010A0928 OM3 010A0928 OM4
= Type R+M with zirconia ceramic ferrule.
APC and HRL connectors with 8 angled ferrule endfaces.
Other fiber types, connector types and numbers of fibers on request.
MTP is a registered trademark of US-Conec Ltd.

97

assemblies PreCONNECT Fiber

PreCONNECT Fiber Trunk Multi Jumper

Application specific leg lengths, both sides to be selected:


Duplex connectors on 2.1 mm leg, leg lengths up to max. 3 m
Compact connectors on 2.9 mm leg, leg lengths up to max. 5 m

APPLICATIONS

CABLE TYPES

Infrastructure cabling of data centers, SAN and serverfarms


Particularly appropriate for individual switch cabling in
data centers

With all standard loose tube cables up to 144 fibers


available
Cable data sheets on request

Properties

FIBER TYPES

See technology description pages 48 50


Both sides factory assembled with FO connectors
Standard light propagation channelwise crossed
(pairwise flipped)
Cable length up to 2,000 m, longer on request
High flexibility due to application specific leg lengths, both
sides to be selected:
Duplex connectors on 2.1 mm leg, leg lengths up to max.
3m
Compact connectors on 2.9 mm leg, leg lengths up to
max. 5 m

With all standard fiber types available


Fiber data sheets on request

LENGTH DEFINITION
Order length: length between the connectors at the
longest legs at both sides (not between the cable dividers)
Length tolerances:
up to 10 m
= +/- 50 cm
11 m to 30 m
= +/- 100 cm
31 m to 100 m = +/- 150 cm
longer than 100 m = +/- 2 %

98

CONNECTORS
With all standard connectors available

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels behind both cable dividers
Application specific legs packed in dust-proof foil-tubes,
not in robust installation tubes
Dependent on the length as cable ring, on cardboard or
wooden drum

Installation Tube Indoor,


IP50 dust-proof

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Fiber

PreCONNECT Fiber Trunk Multi Jumper


Efficiency Indoor Cable
with Mini Loose Tubes
Cable type I-B(ZN)BH 6 x 12

TECHNICAL DATA Cable type I-B(ZN)BH n x m


CABLE DESIGN

STRANDED MINI LOOSE TUBES

NUMBER OF FIBERS, max.

36

48

72

96

144

OUTER- [mm]

8.4

9.4

11.4

MAX. Tensile strength [N]

3000

3000

3000

3000

3000

MAX. CRUSH RESISTANCE [N/dm]

1000

1000

1000

1000

1000

MIN. BENDING RADIUS [mm] static



dynamic

80
120

80
120

84
126

94
141

114
171

FIRE LOAD [MJ/m]

0.69

0.69

0.73

0.92

1.43

COMPARISON MATRIX CABLE PROPERTIES U-DQ(ZN)BH vs. I-B(ZN)BH see page 101.

OS2
9/125

OM3
50/125

OM4
50/125

36

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

049 A 1940
049 A 1901
049 A 1396
049 A 1921

049 A 1950 OM3


049 A 1911 OM3
049 A 1496 OM3
049 A 1931 OM3

049 A 1950 OM4


049 A 1911 OM4
049 A 1496 OM4
049 A 1931 OM4

48

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

049 A 1941
049 A 1902
049 A 1397
049 A 1922

049 A 1951 OM3


049 A 1912 OM3
049 A 1497 OM3
049 A 1932 OM3

049 A 1951 OM4


049 A 1912 OM4
049 A 1497 OM4
049 A 1932 OM4

72

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

049 A 1942
049 A 1903
049 A 1398
049 A 1923

049 A 1952 OM3


049 A 1913 OM3
049 A 1498 OM3
049 A 1933 OM3

049 A 1952 OM4


049 A 1913 OM4
049 A 1498 OM4
049 A 1933 OM4

96

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

049 A 1943
049 A 1904
049 A 1738
049 A 1924

049 A 1953 OM3


049 A 1914 OM3
049 A 1784 OM3
049 A 1934 OM3

049 A 1953 OM4


049 A 1914 OM4
049 A 1784 OM4
049 A 1934 OM4

144

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

049 A 1944
049 A 1905
049 A 1399
049 A 1925

049 A 1954 OM3


049 A 1915 OM3
049 A 1499 OM3
049 A 1935 OM3

049 A 1954 OM4


049 A 1915 OM4
049 A 1499 OM4
049 A 1935 OM4

NUMBER OF FIBERS / CONNECTORS

PreCONNECT FIBER

PARTNUMBERS

Other fiber types, connector types and numbers of fibers on request.

ROSENBERGER OSI PRODUCT CATALOG

99

assemblies PreCONNECT Fiber

PreCONNECT Fiber Trunk Multi Jumper


Universal Cable with Loose Tube Design

Cable type U-DQ(ZN)BH 24

Cable type U-DQ(ZN)BH 6 x 12

TECHNICAL DATA cable type U-DQ(ZN)BH n x m


CABLE DESIGN

CENTRAL LOOSE TUBE

STRANDED LOOSE TUBES

NUMBER OF FIBERS, max.

12

24

36

48

72

96

144

outer- [mm]

7.5

12.5

12.5

13.4

14.4

17.7

MAX. Tensile strength [N]

1750

1750

6000

6000

6000

6000

6000

MAX. CRUSH RESISTANCE [N/dm]

1500

1500

3000

3000

3000

3000

3000

MIN. BENDING RADIUS [mm] static


dynamic

105
140

115
150

190
250

190
250

200
270

215
290

270
355

FIRE LOAD [MJ/m]

0.71

0.79

3.1

3.1

3.2

3.4

4.5

COMPARISON MATRIX CABLE PROPERTIES U-DQ(ZN)BH vs. I-B(ZN)BH see page 101.

PARTNUMBERS
OS2
9/125

OM3
50/125

OM4
50/125

12

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

041 A 2050
041 A 1908
041 A 1392
041 A 1939

041 A 2060 OM3


041 A 1907 OM3
041 A 1492 OM3
041 A 1940 OM3

041 A 2060 OM4


041 A 1907 OM4
041 A 1492 OM4
041 A 1940 OM4

16

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

041 A 2051
041 A 2040
041 A 1393
041 A 1927

041 A 2061 OM3


041 A 1928 OM3
041 A 1493 OM3
041 A 1926 OM3

041 A 2061 OM4


041 A 1928 OM4
041 A 1493 OM4
041 A 1926 OM4

NUMBER OF FIBERS / CONNECTORS

Other fiber types, connector types and numbers of fibers on request.

100

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Fiber

PARTNUMBERS
OM3
50/125

OM4
50/125

24

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

041 A 2052
041 A 1900
041 A 1394
041 A 1920

041 A 2062 OM3


041 A 1910 OM3
041 A 1494 OM3
041 A 1930 OM3

041 A 2062 OM4


041 A 1910 OM4
041 A 1494 OM4
041 A 1930 OM4

36

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

041 A 2053
041 A 1901
041 A 1396
041 A 1921

041 A 2063 OM3


041 A 1911 OM3
041 A 1496 OM3
041 A 1931 OM3

041 A 2063 OM4


041 A 1911 OM4
041 A 1496 OM4
041 A 1931 OM4

48

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

041 A 2054
041 A 1902
041 A 1397
041 A 1922

041 A 2064 OM3


041 A 1912 OM3
041 A 1497 OM3
041 A 1932 OM3

041 A 2064 OM4


041 A 1912 OM4
041 A 1497 OM4
041 A 1932 OM4

72

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

041 A 2055
041 A 1903
041 A 1398
041 A 1923

041 A 2065 OM3


041 A 1913 OM3
041 A 1498 OM3
041 A 1933 OM3

041 A 2065 OM4


041 A 1913 OM4
041 A 1498 OM4
041 A 1933 OM4

96

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

041 A 2056
041 A 1904
041 A 1783
041 A 1924

041 A 2066 OM3


041 A 1914 OM3
041 A 1784 OM3
041 A 1934 OM3

041 A 2066 OM4


041 A 1914 OM4
041 A 1784 OM4
041 A 1934 OM4

144

LC-Compact SC-Duplex
LC-Compact LC-Compact
MU-Duplex-Horizontal SC-Duplex
MU-Duplex-Horizontal LC-Compact

041 A 2057
041 A 1905
041 A 1399
041 A 1925

041 A 2067 OM3


041 A 1915 OM3
041 A 1499 OM3
041 A 1935 OM3

041 A 2067 OM4


041 A 1915 OM4
041 A 1499 OM4
041 A 1935 OM4

2
PreCONNECT FIBER

OS2
9/125

NUMBER OF FIBERS / CONNECTORS

Other fiber types, connector types and numbers of fibers on request.

COMPARISON MATRIX CABLE PROPERTIES U-DQ(ZN)BH vs. I-B(ZN)BH


PROPERTIES

Handling

Mechanical robustness

Suitability for top of rack


cabling

High bending flexibility


Small bending radii
Low weight
High tensile strength
High crush resistance
High torsion strength
Low weight
Low fire load

U-DQ(ZN)BH (Universal)

I-B(ZN)BH (Efficiency)

+
+
+

++
++
++

++
++
++

+
+
+

+
+

++
++

+ good ++ excellent

ROSENBERGER OSI PRODUCT CATALOG

101

assemblies PreCONNECT Fiber

PreCONNECT Fiber Breakout

APPLICATIONs

FIBER TYPES

Installation in data centers for short links with a few fibers

With all standard fiber types available


Fiber data sheets on request

PROPERTIES
Both sides factory assembled with FO connectors
Tool-less mounting in 19 panels and universal holders
through PreCONNECT square interface at both sides
Standard light propagation simplex connectors: 1 to n,
duplex connectors channelwise crossed
(pairwise flipped)
Leg length to be selected from 20 cm to max. 5 m
Cable length up to 1,000 m

LENGTH DEFINITION
Order length: length between the connectors at the
longest legs at both sides (not between the cable dividers)
Length tolerances:
up to 10 m
= +/- 50 cm
11 m to 30 m
= +/- 100 cm
31 m to 100 m = +/- 150 cm
longer than 100 m = +/- 2 %

CONNECTORS
With all standard single-fiber connectors and their
duplex variants available
With MTP connectors

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels behind both cable dividers
Connector legs packed in dust-proof foil-tubes, also
available in robust installation tubes on request
Dependent on the length as cable ring, on cardboard or
wooden drum
MTP is a registered trademark of US-Conec Ltd.

CABLE TYPES
Robust FRNC-LSZH breakout cables up to 24 fibers
Cable data sheets on request

102

Installation Tube Indoor,


IP50 dust-proof

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Fiber

Cable type I-V(ZN)HH

PARTNUMBERS
CONNECTORS

OS2
9/125

OM3
50/125

OM4
50/125

6 CH / 12 F

LC-Compact LC-Compact
MU-Duplex-Horizontal MU-Duplex-Horizontal
MTP 12-female MTP 12-female

036A0512
036A0513
037A0102

0 3 6 A 0 5 0 3 OM3
0 3 6 A 0 5 0 2 OM3
0 3 7 A 0 1 0 0 OM3

0 3 6 A 0 5 0 3 OM4
0 3 6 A 0 5 0 2 OM4
0 3 7 A 0 1 0 0 OM4

12 CH / 24 F

LC-Compact LC-Compact
MU-Duplex-Horizontal MU-Duplex-Horizontal
MTP 12-female MTP 12-female

036A0514
036A0515
037A0103

0 3 6 A 0 5 0 4 OM3
0 3 6 A 0 5 0 6 OM3
0 3 7 A 0 1 0 1 OM3

0 3 6 A 0 5 0 4 OM4
0 3 6 A 0 5 0 6 OM4
0 3 7 A 0 1 0 1 OM4

2
PreCONNECT FIBER

CHANNELS/
FIBERS

Other fiber types, connector types and numbers of fibers on request. With single-fiber connectors only up to 24 fibers available. With MTP connectors at both sides up to
144 fibers available. Hybrid cables with MTP to single-fiber connectors not possible. MTP is a registered trademark of US-Conec Ltd.

On request also available in the known design


without PreCONNECT square interface or as
factory assembled mini breakout cable.

Mini breakout
cable type I-V(ZN)H

Breakout

Mini breakout

ROSENBERGER OSI PRODUCT CATALOG

103

assemblies PreCONNECT FIBER

PreCONNECT FIBER MTP DIVIDER CABLES (HARNESSES)

Type 1

APPLICATION of TYPE 1
For cabling of large servers and switches in data centers

APPLICATION of TYPE 2
In case longer Harness lengths are required, e.g. for cabling
of rack rows in data centers

PROPERTIES of TYPE 1
This MTP Divider Cable (also named Harness) separates the
channels of MTP trunk cables in duplex connectors like e.g.
LC-Compact.
15 cm MTP leg, duplex connector leg lengths to be
selected
Shortest total length: 60 cm
Longest total length: 4 m

Type 2

CABLE TYPES
Different FRNC-LSZH cables and connector legs
Cable data sheets on request
FIBER TYPES
Acc. to partnumber table
Other fiber types and fiber data sheets on request

CONNECTORS
MTP 12 fiber with guide-pins (male) and all standard
duplex connectors

LIGHT PROPAGATION
Uncrossed (straight) to maintain the channelwise cross
(pairwise flip) of our MTP trunk cables

PROPERTIES of TYPE 2

DELIVERY FORM

This MTP Divider Cable (also named Harness) separates the


channels of MTP trunk cables in duplex connectors like e.g.
LC-Compact.
Robust double jacket MTP leg length to be selected, fixed
duplex connector legs
Shortest total length: 60 cm
Longest total length: no limit

Factory measured Insertion Loss (IL), including measurement report acc. to IEC 61300-3-4 methode Substitution
Product ID label
Each packed in a foil bag

MTP is a registered trademark of US-Conec Ltd.

104

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT FIBER

MTP DIVIDER CABLE


Type 1
PARTNUMBERS
FIBERTYPE
CONNECTORS

MTP 12-male 6 LC-Compact


15 cm MTP leg

OS2
9/125

OM3
50/125

OM4
50/125

075A0500

0 7 5 A 0 5 0 1 OM3

0 7 5 A 0 5 0 1 OM4

With other duplex connectors on request. MTP is a registered trademark of US-Conec Ltd.

MTP DIVIDER CABLE


Type 2

PreCONNECT FIBER

PARTNUMBERS
FIBERTYPE
CONNECTORS

OS2
9/125

OM3
50/125

OM4
50/125

MTP 12-male 6 LC-Compact


0.5 m duplex connector leg

076A0100

0 7 6 A 0 1 0 1 OM3

0 7 6 A 0 1 0 1 OM4

MTP 12-male 6 LC-Compact


1.5 m duplex connector leg

076A0103

0 7 6 A 0 1 0 4 OM3

0 7 6 A 0 1 0 4 OM4

With other duplex connectors on request. Other duplex connector legs application specific fitting for the to be attached equipment on request.
MTP is a registered trademark of US-Conec Ltd.

Our Migration Harnesses for 40 and 100 Gigabit Ethernet


OM3 and OM4 (Parallel Optics) are to be found on page 107.

ROSENBERGER OSI PRODUCT CATALOG

105

assemblies PreCONNECT Fiber

PreCONNECT Fiber for Specific Applications


PARALLEL OPTICS IN THE DATA CENTER

APPLICATIONs

CONNECTORS

To attach equipment with multimode MTP transceivers


for the transmission protocols InfiniBand and 40/100
Gigabit Ethernet

With MTP, LC and SC connectors

DELIVERY FORM

CABLE TYPES

Factory measured Insertion Loss (IL), including measurement report


Product ID labels on both sides
Connector legs packed in dust-proof foil-tubes, also
available in robust indoor installation tubes on request
Dependent on the length as cable ring, on cardboard or
wooden drum

Different FRNC-LSZH cables


Cable data sheets on request

MTP is a registered trademark of US-Conec Ltd.

PROPERTIES
Factory assembled connectors on both sides
Appropriate for 4 x, 8 x and 12 x InfiniBand and 40/100
Gigabit Ethernet

FIBER TYPES
Multimode OM3 and OM4
Fiber data sheets on request
Installation Tube Indoor,
IP50 dust-proof

106

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Fiber

Parallel Optics Infiniband


PARTNUMBERS
NUMBER OF FIBERS /
CONNECTORS

12
12
24
8
8
12
12

Direct Attach Short Link Cable MTP 12-female MTP 12-female


Direct Attach Long Link Cable MTP 12-female MTP 12-female
Direct Attach Long Link Cable MTP 12-female MTP 12-female
Migration Harness MTP 12-female 8 SC-Simplex
Migration Harness MTP 12-female 8 LC-Simplex
Migration Harness MTP 12-female 12 SC-Simplex
Migration Harness MTP 12-female 12 LC-Simplex

OM3
50/125

OM4
50/125

0 8 0 A 0 5 8 0 OM3
0 8 0 A 0 7 4 3 OM3
0 8 0 A 0 7 4 2 OM3
0 7 6 A 0 0 5 0 OM3
0 7 6 A 0 0 5 1 OM3
0 7 6 A 0 0 6 0 OM3
0 7 6 A 0 0 6 1 OM3

0 8 0 A 0 5 8 0 OM4
0 8 0 A 0 7 4 3 OM4
0 8 0 A 0 7 4 2 OM4
0 7 6 A 0 0 5 0 OM4
0 7 6 A 0 0 5 1 OM4
0 7 6 A 0 0 6 0 OM4
0 7 6 A 0 0 6 1 OM4

Other fiber types, connector types and numbers of fibers on request. MTP is a registered trademark of US-Conec Ltd.

Parallel Optics 40 Gigabit Ethernet

NUMBER OF FIBERS /
CONNECTORS

12
12
8
8

Direct Attach Short Link Cable MTP 12-female MTP 12-female


Direct Attach Long Link Cable MTP 12-female MTP 12-female
Migration Harness MTP 12-female 8 SC-Simplex
Migration Harness MTP 12-female 8 LC-Simplex

OM3
50/125

OM4
50/125

0 8 0 A 0 5 8 0 OM3
0 8 0 A 0 7 4 3 OM3
0 7 6 A 0 0 5 0 OM3
0 7 6 A 0 0 5 1 OM3

0 8 0 A 0 5 8 0 OM4
0 8 0 A 0 7 4 3 OM4
0 7 6 A 0 0 5 0 OM4
0 7 6 A 0 0 5 1 OM4

PreCONNECT FIBER

PARTNUMBERS

Other fiber types, connector types and numbers of fibers on request. MTP is a registered trademark of US-Conec Ltd.

Parallel Optics 100 Gigabit Ethernet


PARTNUMBERS
NUMBER OF FIBERS /
CONNECTORS
24
24
20
20

Direct Attach Short Link Cable MTP 24-female MTP 24-female


Direct Attach Long Link Cable MTP 24-female MTP 24-female
Migration Harness MTP 24-female 20 SC-Simplex
Migration Harness MTP 24-female 20 LC-Simplex

OM3
50/125

OM4
50/125

0 8 0 A 0 8 4 5 OM3
0 8 0 A 0 8 4 6 OM3
0 8 0 A 0 8 4 7 OM3
0 8 0 A 0 8 4 8 OM3

0 8 0 A 0 8 4 5 OM4
0 8 0 A 0 8 4 6 OM4
0 8 0 A 0 8 4 7 OM4
0 8 0 A 0 8 4 8 OM4

Other fiber types, connector types and numbers of fibers on request. MTP is a registered trademark of US-Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

107

assemblies PreCONNECT Fiber

PreCONNECT Fiber for Specific Applications


PreCONNECT Fiber Trunk Mobile

3
2

Model 2

4
Variant with Heavy Duty
connector

Model 1

APPLICATIONS

CABLE TYPES

For emergency replacement of broken FO links indoor


and outdoor
Broadcast: for mobile use in event and presentation
technics e.g. TV transmission
Industry: for mobile use e.g. mining

With robust and flexible loose tube cables up to 24 fibers


available
With breakout cable for outdoor applications available
With hybrid cable (FO/copper) available
Cable data sheets on request

PROPERTIES

FIBER TYPES

Mobile trunk with high quality robust drum


Enhanced protection through captive installation tubes for
all standard connectors at both sides
Halogen-free and flexible at low temperature
Notch proof and abrasion resistant
Oil and chemical resistant
Factory assembled connectors on both sides
Standard light propagation channelwise crossed
(pairwise flipped)

With all standard fiber types available


Fiber data sheets on request

LENGTH DEFINITION
Order length: length between the connectors at the
longest legs at both sides (not between the cable dividers)
Length tolerances:
up to 10 m
= +/- 50 cm
11 m to 30 m
= +/- 100 cm
31 m to 100 m = +/- 150 cm
longer than 100 m = +/- 2 %
Leg lengths on both sides stepped acc. to table page 95,
suited for application in distribution panels

108

CONNECTORS
With all standard connectors available, see pages 62 73
With all Heavy Duty connectors (IP67) available,
see pages 82 85

Optional
Cable with increased tensile strength and crush resistance
Cable with special armoring
Transport cart or trolley

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels behind both cable dividers
Dependent on the length on cardboard, wooden or mobile
drum
Partnumbers on request

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Fiber

model 1: Installation tube on both sides


Both sides of the cable are equipped with our robust
PreCONNECT Cable Divider with stepped fanout legs,
being assembled with fiber optic connectors (1).
The cable dividers and fanout legs including the fiber optic
connectors are protected by captive installation tubes.
Water proofing, tensile strength and crush resistance are
guaranteed up to IP67 specifications. Installation tubes
provide protection during storage, transport, installation
and operation.
The free cable length up to the connectors at the drum
side (2) is approx. 3 m by default.
Further lengths on request.

Captive installation
tubes on both sides,
IP67 water-proof

model 2: Installation tube and outlet Socket

The connectors on the inner end are attached to the couplers


on the drum winding side inside the shock-proof and IP50
dust-proof steel outlet socket with its protective cover (3).
This protects the fiber optic interface against damage
during storage, transportation, installation and operation.
On the other end the one which can be unrolled there
is our robust PreCONNECT Cable Divider with stepped
connectorised fanout legs (4).
The cable divider and fanout legs including the fiber optic
connectors are protected by the captive installation tube.
Water proofing, tensile strength and crush resistance are
guaranteed up to IP67 standards. The installation tube
ensures protection during storage, transportation, installation and operation.

PreCONNECT FIBER

Transport cart

Trolley

Chaining kit for model 2


The chaining kit is an option for PreCONNECT Mobile type 2
models. They can be chained or connected to achieve longer
distances.
The kit consists of a small cage and a robust protection
cover (6).
The cage (5) has to be mounted next to the outlet socket
(7) of the extension drum
It accepts the cable divider (8) and the connector legs of
the PreCONNECT Mobile drum, which requires chaining
and connecting.
The protection cover (6) has to be placed over the extension
drum for protection against moisture and dirt.

5
6

ROSENBERGER OSI PRODUCT CATALOG

Chaining kit

109

assemblies PreCONNECT FIBER

PreCONNECT Fiber for Specific Applications


PreCONNECT FIBER Trunk Outdoor

APPLICATIONS
Ready-for-connection multi-channel cable for harsh outdoor
environment
To integrate security and mobile telecommunications (FTTA)
equipment in unprotected outdoor environment into structured cabling

PROPERTIES





See technology description pages 48 50


Appropriate for use in temperature range -40 C to +85 C
High UV resistance
High crush resistance
Both sides factory assembled with FO connectors
Standard light propagation channelwise crossed
(pairwise flipped)
Cable length up to 2,000 m, longer on request

LENGTH DEFINITION
Order length: length between the connectors at the longest legs at both sides (not between the cable dividers)
Length tolerances:
up to 10 m
= +/- 50 cm
11 m to 30 m
= +/- 100 cm
31 m to 100 m = +/- 150 cm
longer than 100 m = +/- 2 %
Leg lengths on both sides stepped acc. to table page 95,
suited for application in distribution panels

CABLE TYPES
Central loose tube cables up to 36 fibers available
IEC and UL specified cable available
Cable data sheets on request
FIBER TYPES
Singlemode (9/125 m) and multimode (50/125 m)
Fiber data sheets on request

CONNECTORS
LC-Compact
Other connector types on request

Optional



Special rodent protection armoring


Hybrid connector assembling
OTDR measured with measurement report
Return loss (RL) measurement

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels behind both cable dividers
Dependent on the length as cable ring, on cardboard
or wooden drum

Installation Tube Outdoor,


IP67 water-proof

110

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT FIBER

Operating temperature range: -40 C to +85 C,


for less robust outdoor applications see
PreCONNECT FIBER Trunk page 97

Cable type A-DQ(ZN)B2Y 24

TECHNICAL DATA
12

24

36

55 - 80
135 - 220

55 - 80
55 - 80

60 - 85
195 - 220

DIAMETER INSTALLATION TUBE [cm] approx.

34

34

38

MAX. TENSILE STRENGTH INSTALLATION TUBE [N]

600

600

600

CRUSH RESISTANCE INSTALLATION TUBE [N/cm]

30

30

30

LEG LENGTH STEPPED [cm] side A


side B

2
PreCONNECT FIBER

NUMBER OF FIBERS

PARTNUMBERS
CHANNELS/
FIBERS

CONNECTORS

G657 a2

MM OM2

6 ch / 12 F

LC-Compact LC-Compact

048A0150

048A0151

12 CH / 24 F

LC-Compact LC-Compact

048A0152

048A0153

18 ch / 36 F

LC-Compact LC-Compact

048A0154

048A0155

SM OS2, MM OM3 and OM4 and other connector types and leg lengths on request.

ROSENBERGER OSI PRODUCT CATALOG

111

assemblies PreCONNECT FIBER

PreCONNECT FIBER Breakout Outdoor


(Single-channel)

Conventional outdoor breakout cable

APPLICATIONS

CABLE TYPES

Ready-for-connection single-channel cable for harsh outdoor


environment
To integrate security and mobile telecommunications (FTTA)
equipment in unprotected outdoor environment into structured cabling

Mini breakout and breakout


IEC and UL specified cable available
Cable data sheets on request

PROPERTIES





Appropriate for use in temperature range -40 C to +85 C


High UV resistance
High crush resistance
Both sides factory assembled with FO connectors
Single data channel in one cable
Standard light propagation channelwise crossed
(pairwise flipped)
Leg lengths applicationspecific selectable
Cable length to be selected

LENGTH DEFINITION
Length tolerances:
up to 10 m
=
11 m to 30 m
=
31 m to 100 m =
longer than 100 m =

FIBER TYPES
Singlemode (9/125 m) and multimode (50/125 m)
Fiber data sheets on request

+/- 50 cm
+/- 100 cm
+/- 150 cm
+/- 2 %

CONNECTORS
LC-Duplex, LC-Compact, Rosenberger Duplex Connector
(RDC)
Other connector types on request

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels on both sides
Connector protection on request
Dependent on the length as cable ring in cardboard box
or on cardboard drum

Installation Tube Outdoor,


IP67 water-proof

112

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT FIBER

Outdoor breakout cable


with hot-melt technology

CHANNELS/
FIBERS

CONNECTOR

OS 2
9/125

OM 2
50/125

1 ch / 2 F

5 mm

LC-Duplex LC-Duplex
RDC LC-Duplex

087A6700
087A6704

087A6701
087A6705

1 ch / 2 F

7 mm

LC-Duplex LC-Duplex
RDC LC-Duplex

087A6706
087A6710

087A6707
087A6711

2
PreCONNECT FIBER

PARTNUMBERS

Conventional BREAKOUT CABLE

OM3 and OM4 on request

PARTNUMBERS

BREAKOUT CABLE WITH HOT-MELT technology


CHANNELS/
FIBERS

CONNECTOR

OS 2
9/125

OM 2
50/125

1 ch / 2 F

5 mm

LC-Compact LC-Compact

087A6702

087A6703

1 ch / 2 F

7 mm

LC-Compact LC-Compact

087A6708

087A6709

OM3 and OM4 on request

ROSENBERGER OSI PRODUCT CATALOG

113

assemblies PreCONNECT FIBER

PreCONNECT FIBER Breakout Outdoor


(Multi-channel)

6 channel outdoor mini breakout cable

APPLICATIONS

CABLE TYPES

Ready-for-connection multi-channel cable for harsh outdoor


environment
To integrate security and mobile telecommunications (FTTA)
equipment in unprotected outdoor environment into structured cabling

Mini breakout (900 m)


IEC and UL specified cable available
Cable data sheets on request

PROPERTIES






Appropriate for use in temperature range -40 C to +85 C


High UV resistance
High crush resistance
Both sides factory assembled with FO connectors
3 or 6 data channels in one cable
Singular coded duplex connectors
Standard light propagation channelwise crossed
(pairwise flipped)
Leg lengths applicationspecific selectable
Cable length to be selected

LENGTH DEFINITION
Order length: length between the connectors at the longest legs at both sides (not between the cable dividers)
Length tolerances:
up to 10 m
= +/- 50 cm
11 m to 30 m
= +/- 100 cm
31 m to 100 m = +/- 150 cm
longer than 100 m = +/- 2 %

FIBER TYPES
Singlemode (9/125 m) and multimode (50/125 m)
Fiber data sheets on request

CONNECTORS
LC-Duplex
Other connector types on request

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels behind both cable dividers
Connector legs packed in dust-proof foil-tubes, on request
in robust installation tubes available too
Dependent on the length as cable ring in cardboard box or
on cardboard drum

Installation Tube Outdoor,


IP67 water-proof

114

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT FIBER

3 channel outdoor mini breakout cable

NUMBER OF FIBERS

12

50 - 60

50 - 75

DIAMETER INSTALLATION TUBE [mm] approx.

23

23

MAX. TENSILE STRENGTH INSTALLATION


TUBE [N]

600

600

CRUSH RESISTANCE INSTALLATION TUBE [N/cm]

350

350

LEG LENGTH STEPPED [cm]

PreCONNECT FIBER

TECHNICAL DATA

PARTNUMBERS
CHANNELS/
FIBERS

CONNECTOR

OS 2
9/125

OM 2
50/125

3 ch / 6 F

LC-Duplex LC-Duplex

048A0156

048A0157

6 CH / 12 F

LC-Duplex LC-Duplex

048A0158

048A0159

SM OS2, MM OM3 and OM4 on request.

ROSENBERGER OSI PRODUCT CATALOG

115

assemblies PreCONNECT FIBER

PreCONNECT FIBER CABLEBUNDLE Outdoor


(3-4 channel)

APPLICATIONS

CABLE TYPES

Ready-for-connection 4-channel cable for harsh outdoor


environment
To integrate security and mobile telecommunications (FTTA)
equipment in unprotected outdoor environment into structured cabling

Central loose tube cables up to 36 fibers available


IEC and UL specified cable available
Cable data sheets on request

FIBER TYPES
Singlemode (9/125 m) and multimode (50/125 m)
Fiber data sheets on request

PROPERTIES
Assembled cable bundle with individual selectable leg
lengths (4 bundles)

LENGTH DEFINITION
Order length: length between the connectors at the longest legs at both sides (not between the cable dividers)
Length tolerances:
up to 10 m
= +/- 50 cm
11 m to 30 m
= +/- 100 cm
31 m to 100 m = +/- 150 cm
longer than 100 m = +/- 2 %
Leg lengths on both sides stepped acc. to table page 95,
suited for application in distribution panels

CONNECTORS
LC-Duplex, LC-Compact, Rosenberger Duplex
Connector (RDC)
Other connector types on request

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels on both sides
Connector protection on request
Dependent on the length as cable ring in cardboard box or
on cardboard drum

PARTNUMBERs
CHANNELS/
FIBERS

CONNECTOR

G657 a2

MM OM2

4 ch / 8 F

RDC LC-Compact
LC-Compact LC-Compact

048A0122
048A0119

048A0121
048A0120

SM OS2, MM OM3 and OM4 on request.

116

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT FIBER

PreCONNECT TOWER Multi-fiber SYSTEM (TMFS)


(Multi-channel)

CABLE TYPES

To integrate security and mobile telecommunications (FTTA)


equipment in unprotected outdoor environment into structured cabling

Central loose tube cables up to 36 fibers available


IEC and UL specified cable available
Cable data sheets on request

PROPERTIES

FIBER TYPES

Assembled Rosenberger Duplex Connector (RDC)


distribution unit with fix attached multifiber cable
Distribution unit with up to 18 RDC receptacles
IP67 water-proof

Singlemode (9/125 m) and multimode (50/125 m)


Fiber data sheets on request

LENGTH DEFINITION
Order length: length between the connectors at the longest legs at both sides (not between the cable dividers)
Length tolerances:
up to 10 m
= +/- 50 cm
11 m to 30 m
= +/- 100 cm
31 m to 100 m = +/- 150 cm
longer than 100 m = +/- 2 %

2
PreCONNECT FIBER

APPLICATIONs

CONNECTORS
Side A: LC-Compact
Side B (distribution unit): Rosenberger Duplex Connector
(RDC) receptacle

DELIVERY FORM
Factory measured Insertion Loss (IL), including measurement report
Product ID labels on both sides
Connector protection on request
Dependent on the length as cable ring in cardboard box or
on cardboard drum

PARTNUMBER
CHANNELS/
FIBERS

CONNECTOR

G657 a2

MM OM2

12 CH / 24 F

RDC LC-Compact

048A0160

048A0161

SM OS2, MM OM3 and OM4 on request. 12 and 36 fibers on request.

ROSENBERGER OSI PRODUCT CATALOG

117

assemblies PreCONNECT Fiber

PreCONNECT Fiber ACCESSORIES


PARTNUMBER

19 1 HU Universal-trunk cable
divider holder

For universal installation of trunk cable dividers


in 19 cabinets/racks.
RAL 9005 (black)

099A0085

PARTNUMBER

19 1 HU Universal-trunk cable
divider holder
For universal installation of a trunk cable divider
in a 19 cabinet/rack or at any place where this
part can be installed individually.
RAL 9005 (black)
099A0065

PARTNUMBER

MTP 19 UNIVERSAL-COUPLER BRACKETS

For universal MTP cabling in 19 cabinets


and racks. Particularly suited for cabling of large
switches with high port density.
12 x MTP singlemode 9/125 m
12 x MTP multimode 50/125 m OM3
12 x MTP multimode 50/125 m OM4
19 1 HU support for brackets
RAL 9005 (black)

099A0366
0 9 9 A 0 3 6 5 OM3
0 9 9 A 0 3 6 5 OM4
099A0086

MTP is a registered trademark of US-Conec Ltd.

118

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Fiber

MINI-UNIVERSAL COUPLER BRACKETS

6 x MU-Duplex
Width: 80 mm
Height: 1 HU = 44 mm

6 x LC-Duplex

3 x MTP

Applications

Properties and delivery form

Suited for installation at 19 bars and for


universal mounting

Material: steel, powder coated


Colour: RAL 9005 (black)
Long holes for universal installation
Couplers mounted
Without screws and cage nuts

2
Number of Couplers/
type of coupler

SM

MM
50 m OM3

MM
50 m OM4

MU-Duplex

099A0348

0 9 9 A 0 3 5 0 OM3

0 9 9 A 0 3 5 0 OM4

MU-Duplex

099A0351

0 9 9 A 0 3 5 3 OM3

0 9 9 A 0 3 5 3 OM4

MU-Duplex

099A0354

0 9 9 A 0 3 5 6 OM3

0 9 9 A 0 3 5 6 OM4

LC-Duplex

099A0345

0 9 9 A 0 3 4 7 OM3

0 9 9 A 0 3 4 7 OM4

LC-Duplex

099A0342

0 9 9 A 0 3 4 4 OM3

0 9 9 A 0 3 4 4 OM4

LC-Duplex

099A0340

0 9 9 A 0 3 0 5 OM3

0 9 9 A 0 3 0 5 OM3

MTP

099A0362

0 9 9 A 0 3 6 4 OM3

0 9 9 A 0 3 6 4 OM4

MTP

099A0359

0 9 9 A 0 3 6 1 OM3

0 9 9 A 0 3 6 1 OM4

MTP

099A0357

0 9 9 A 0 3 0 6 OM3

0 9 9 A 0 3 0 6 OM4

PreCONNECT FIBER

PARTNUMBERS

Other coupler types and numbers on request. MTP is a registered trademark of US-Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

119

PreCONNECT Copper

120

ROSENBERGER OSI PRODUCT CATALOG

Assemblies: PreCONNECT Copper

Our PreCONNECT COPPER Trunks were developed on the background of our experience and
know-how in fiber optic technology, which we
transferred to the structured copper cabling.
In that way we engineered for example the
PreCONNECT COPPER Trunk ToR, which despite
its six channels, is one of the thinnest and most

ROSENBERGER OSI PRODUCT CATALOG

flexible of its kind and thus perfectly suitable


for Top of Rack application in data centers.
The cable is very installation friendly due to its
very small bending radius and diameter. And:
it contributes excellently to the server room
cooling, because it does not impair the air flow
as it is the case with conventional copper cables.

121

assemblies PreCONNECT Copper

PreCONNECT Copper Trunk

Required diameter of cable feedthrough minimum 90 mm

APPLICATIONs

JACK MODULES

6 channel copper data cable on both sides assembled with


RJ45 jack modules ready-for-connection particularly in
data center installations.

RJ45, screened Cat. 6A


Suited for standard keystone holes

PROPERTIES

Factory measured with measurement report


Product ID labels on both sides
Jack modules packed in tensile strength and dust-proof
pulling socks
On request packed in tensile strength, crush resistant and
dust-proof installation tubes available
Dependent on the length as cable ring, on cardboard or
wooden drum

DELIVERY FORM

Stranded 6 channel S-STP Cat. 7 AWG 23 FRNC-LSZH


cable with Cat. 6A RJ45 jack modules
GHMT certified
4 connector channel 10 GBE Klasse EA
Leg length 30 cm
Stepped leg lengths also available

CABLE TYPES
6 single stranded Cat.7 S-STP copper data cables taped with
a self-extinguishing, halogen-free and transparent foil tape
Solid wire AWG 23 with screened pairs and overall copper
braid
Cable diameter 22.3 mm

Associated copper panels see page 170.

PARTNUMBERS
PreCONNECT Copper Trunk

047A0101

PARTNUMBERS PATCHCORDS COPPER


Screened Cat. 6 RJ45 connectors with molded boots at Cat. 7 S/FTP FRNC-LSZH flex cable grey
LENGTH

Partnumbers

1m
2m
3m
5m

800A0001
800A0003
800A0005
800A0007

Other lengths, colours and types on request.

122

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Copper

PreCONNECT Copper Trunk ToR

Required diameter of cable feedthrough minimum 90 mm

APPLICATIONs

CABLE TYPES

6 channel copper data cable assembled on both sides with


RJ45 jack modules ready-for-connection, optimized for Top
of Rack (ToR) installations, for use in all other application
fields, in particular in data centers.

Innovative, thin and flexible Cat. 7 copper data cable with


diameter of 18 mm using AWG 23 and 13.2 mm using AWG 26
With 24 foil-screened AWG 23 or AWG 26 solid wire pairs
(PiMF) below an overall copper braid with a FRNC-LSZH cable
jacket

JACK MODULES

RJ45 keystone, screened Cat. 6A


PreCONNECT Copper

PROPERTIES
6 channel S-STP Cat. 7 AWG 23 or AWG 26 FRNC-LSZH
cable with Cat. 6A RJ45 jack modules
High flexibility allows minimum bending radius:
AWG 23 100 mm
AWG 26 55 mm
GHMT certified: 10 GBE class EA permanent link, but
only 80 m with AWG 23 and 60 m with AWG 26
Leg length 20 cm, adapted to the associated panel on
page 171
With cable gland for mounting at the panel

DELIVERY FORM
Factory measured, with measurement report
Product ID labels on both sides
Jack modules packed in tensile strength and dust-proof
pulling socks
Dependent on the length as cable ring, on cardboard or
wooden drum

PARTNUMBERS
PreCONNECT Copper Trunk ToR AWG 23

047A0200

PreCONNECT Copper Trunk ToR AWG 26

047A0300

PARTNUMBERS Patchcords Copper ToR


Screened Cat. 6 RJ45 connectors at Cat. 7 S/FTP FRNC-LSZH flex cable grey
LENGTH

Partnumbers

1m
2m
3m
5m

800A0195
800A0196
800A0194
800A0197

Other lengths, colours and types on request.

ROSENBERGER OSI PRODUCT CATALOG

123

assemblies PreCONNECT Copper

PreCONNECT Copper Trunk Multi Jumper

APPLICATIONs

CONNECTORS

6 channel copper data cable assembled on both sides with


RJ45 connectors or jack modules ready-for-connection
particular in data center installations.

RJ45, screened Cat. 6

PROPERTIES
Appropriate for 4 connector channel 10 GBE class EA,
but only 60 m
Leg length 30 cm for cables with jack modules, stepped leg
lengths also available
Leg length for cables with connectors to be selected

CABLE TYPES
6 single stranded Cat.7 S / FTP copper data cables taped
with a self-extinguishing, halogen-free and transparent
foil tape
Flex braid wire AWG 26 with screened pairs and overall
copper braid
Cable diameter 17.6 mm

JACK MODULES
RJ45, screened Cat. 6A
Suited for standard keystone holes

DELIVERY FORM
Factory measured, with measurement report
Product ID labels on both sides
Connectors and jack modules packed in tensile strength
and dust-proof pulling socks
On request packed in tensile strength, crush resistant and
dust-proof installation tubes available
Dependent on the length as cable ring, on cardboard or
wooden drum

Associated copper panels see page 170.

124

ROSENBERGER OSI PRODUCT CATALOG

assemblies PreCONNECT Copper

You can order the PreCONNECT COPPER Trunk Multi Jumper


either with factory assembled RJ45 connectors or jack
modules.

RJ45 jack modules

PARTNUMBERS
DESCRIPTION

PreCONNECT COPPER Trunk


Multi Jumper
jack module jack module

PreCONNECT COPPER Trunk


Multi Jumper
connector jack module

PreCONNECT COPPER Trunk


Multi Jumper
connector connector

Side A

Side B

PARTNUMBERS

Cat. 6A
RJ45 jack module

Cat. 6A
RJ45 jack module

047A0130

Cat. 6
RJ45 connector

Cat. 6A
RJ45 jack module

047A0131

Cat. 6
RJ45 connector

Cat. 6
RJ45 connector

047A0132

2
PreCONNECT Copper

RJ45 connector

PARTNUMBERS PATCHCORDS COPPER


Screened Cat. 6 RJ45 connectors with molded boots at Cat. 7 S/FTP FRNC-LSZH flex cable grey
LENGTH

Partnumbers

1m
2m
3m
5m

800A0001
800A0003
800A0005
800A0007

Other lengths, colours and types on request.

ROSENBERGER OSI PRODUCT CATALOG

125

patchcords

126

ROSENBERGER OSI PRODUCT CATALOG

Assemblies: PATCHCORDS AND PIGTAILS

Regardless of whether its fiber or copper, due to


the importance of their function, patchcords are
the most heavily stressed components in structured cabling. We at Rosenberger OSI know:
Each network is just as good as its weakest
component. Hence we do not make compromises for patchcords and pigtails too. Finally,
they have a crucial influence on transmission
performance and thus on the quality of cabling
infrastructures.

ROSENBERGER OSI PRODUCT CATALOG

Rosenberger OSI manufactures this group of


products for all application fields with optimized kink and crush resistance for different
environmental conditions. In particular pigtails
need to be installed with much effort. The high
quality cables from Rosenberger OSI ensure a
long and trouble-free life cycle with a minimum
of maintenance effort being required.

127

assemblies Patchcords

PATCHCORDS FIBER

APPLICATIONS

CABLE TYPES

Patchcords appropriate for use in data centers and


office buildings
Patchcords for other applications on request

Different FRNC-LSZH cables


Cable data sheets on request

PROPERTIES

With all standard fiber types available


Fiber data sheets on request

FIBER TYPES

Optimized kink and crush resistance with regards to application requirements


Operating temperature range -10 C to +60 C, patchcords
for other operating temperature ranges on request
Standard light propagation:
Full-duplex-cables: duplex connectors at both sides acc.
to ISO/IEC 11801 and EN 50173 = crossed (flipped)
Half-duplex-cables: duplex-connector at one side an
2 x simplex at the other side = uncrossed (unflipped)
Duplex-cables: with simplex connectors at both sides
= uncrossed (unflipped)

LENGTH TOLERANCES:
Up to 1 m
=
2 m to 3 m
=
4 m to 25 m
=
longer than 25 m =

128

+/- 50 mm
+/- 100 mm
+/- 200 mm
+/- 1 %

CONNECTORS
With all standard connectors available

DELIVERY FORM
Factory Insertion Loss (IL) measured acc. to IEC 61300-3-4
methode C or Substitution, measurement report on
request
Serial number label at both cable ends for use in network
documentation
Product ID label on the package
Each packed in a foil bag, cables longer than 100 m on
cardboard drum

ROSENBERGER OSI PRODUCT CATALOG

assemblies Patchcords

SIMPLEX PATCHCORD
Cable type I-V(ZN)H 1 x 2.1 mm FRNC-LSZH
Partnumbers
CONNECTOR

MU MU
MU LC
LC LC
MU APC MU APC
MU APC LC APC
LC APC LC APC

LENGTH

OS2
9/125

Variable
Variable
Variable
Variable
Variable
Variable

088A0727
087A1007
087A1010
088A0794
088A0728
087A0762

2
patchcords

Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request. Other connector combinations, cable and fiber data
sheets on request.

SIMPLEX PATCHCORD
Cable type I-V(ZN)H 1 x 2.8 mm FRNC-LSZH
Partnumbers
CONNECTOR
SC SC
SC E-2000TM 1
E-2000TM 1 E-2000TM 1
FC PC FC PC
SC APC SC APC
SC APC E-2000TM HRL1
E-2000TM HRL1 E-2000TM HRL1
FC APC FC APC

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable

062A0130
062A0800
069A3085
068A0130
062A0135
062A0841
069A2135
068A0135

0 6 2 A 0 1 1 0 OM3
0 6 2 A 0 8 0 1 OM3
0 6 9 A 2 1 1 0 OM3
0 6 8 A 0 1 1 0 OM3

0 6 2 A 0 1 1 0 OM4
0 6 2 A 0 8 0 1 OM4
0 6 9 A 2 1 1 0 OM4
0 6 8 A 0 1 1 0 OM4

Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request. Other connector combinations, cable and fiber data
sheets on request. 1 = Type R+M with zirconia ceramic ferrule.

ROSENBERGER OSI PRODUCT CATALOG

129

assemblies Patchcords

Duplex PATCHCORD
Cable type Zipcord I-V(ZN)H 2 x 2.1 mm FRNC-LSZH
Partnumbers
CONNECTOR

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

MU-Duplex-Horizontal MU-Duplex-Horizontal
MU-Duplex-Horizontal LC-Duplex
MU-Duplex SC-Duplex
LC-Duplex LC-Duplex
LC-Duplex SC-Duplex

Variable
Variable
Variable
Variable
Variable

088A0208
087A4004
088A2541
087A5005
087A5035

0 8 8 A 0 9 0 0 OM3
0 8 7 A 4 0 1 3 OM3
0 8 8 A 2 5 4 0 OM3
0 8 7 A 5 0 1 5 OM3
0 8 7 A 5 0 4 5 OM3

0 8 8 A 0 9 0 0 OM4
0 8 7 A 4 0 1 3 OM4
0 8 8 A 2 5 4 0 OM4
0 8 7 A 5 0 1 5 OM4
0 8 7 A 5 0 4 5 OM4

Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request. Other connector combinations,
cable and fiber data sheets on request.

Duplex PATCHCORD
Cable type Zipcord I-V(ZN)H 2 x 2.8 mm FRNC-LSZH
Partnumbers
CONNECTOR

SC-Duplex SC-Duplex
SC-Duplex ST
SC-Duplex LC-Duplex
ST ST
E-2000TM Compact1 E-2000TM Compact1
E-2000TM Compact1 SC-Duplex
E-2000TM Simplex1 E-2000TM Simplex1
SC-Simplex APC SC-Simplex APC
E-2000TM Simplex1 HRL E-2000TM Simplex1 HRL

LENGTH

OS2
9/125

OM3
50/125

Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable

062A0180
060A0230
087A2068
060A0180
069A2256
069A2289
069A2180
062A0610
069A2200

0 6 2 A 0 1 6 0 OM3
0 6 0 A 0 2 1 0 OM3
0 8 7 A 2 0 7 8 OM3
0 6 0 A 0 1 6 0 OM3
0 6 9 A 2 2 5 7 OM3
0 6 9 A 2 2 8 4 OM3
0 6 9 A 2 1 6 0 OM3

OM4
50/125
062A0160
060A0210
087A2078
060A0160
069A2257
069A2284
069A2160

OM4
OM4
OM4
OM4
OM4
OM4
OM4

Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request. Other connector combinations,
cable and fiber data sheets on request. 1 = Type R+M with zirconia ceramic ferrule.

130

ROSENBERGER OSI PRODUCT CATALOG

assemblies Patchcords

Duplex patchcord
Cable type double-jacket I-V(ZN)HH 2 x 2.1 mm FRNC-LSZH
Partnumbers
connector

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

LC-Duplex LC-Duplex
LC-Duplex SC-Duplex
MU-Duplex-Horizontal MU-Duplex-Horizontal
MU-Duplex-Horizontal LC-Duplex
E-2000TM Compact1 E-2000TM Compact1
E-2000TM Compact1 LC-Duplex
E-2000TM Simplex1 E-2000TM Simplex1
SC-Simplex APC SC-Simplex APC
E-2000TM Simplex1 HRL E-2000TM Simplex1 HRL

Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable

087A1900
087A2000
088A0206
087A4002
069A3049
087A1205
069A2181
062A0627
069A2202

0 8 7 A 1 9 1 1 OM3
0 8 7 A 2 0 7 9 OM3
0 8 8 A 0 2 1 6 OM3
0 8 7 A 4 0 0 9 OM3
0 6 9 A 3 0 5 9 OM3
0 8 7 A 1 2 0 1 OM3
0 6 9 A 2 1 6 1 OM3

0 8 7 A 1 9 1 1 OM4
0 8 7 A 2 0 7 9 OM4
0 8 8 A 0 2 1 6 OM4
0 8 7 A 4 0 0 9 OM4
0 6 9 A 3 0 5 9 OM4
0 8 7 A 1 2 0 1 OM4
0 6 9 A 2 1 6 1 OM4

2
patchcords

Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request. Other connector combinations,
cable and fiber data sheets on request. 1 = Type R+M with zirconia ceramic ferrule.

Duplex patchcord
Cable type double-jacket I-V(ZN)HH 2 x 2.8 mm FRNC-LSZH
Partnumbers
connector

SC-Duplex SC-Duplex
SC-Duplex ST
SC-Duplex LC-Duplex
ST ST
E-2000TM Compact1 E-2000TM Compact1
E-2000TM Compact1 SC-Duplex
E-2000TM Simplex1 E-2000TM Simplex1
SC-Simplex APC SC-Simplex APC
E-2000TM Simplex1 HRL E-2000TM Simplex1 HRL

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable
Variable

062A0179
060A0229
087A2069
060A0198
069A3043
062A0902
069A2179
062A0612
069A2201

0 6 2 A 0 1 5 9 OM3
0 6 0 A 0 2 0 9 OM3
0 8 7 A 2 0 1 1 OM3
0 6 0 A 0 1 8 6 OM3
0 6 9 A 3 0 4 5 OM3
0 6 2 A 0 9 1 2 OM3
0 6 9 A 2 1 5 9 OM3

0 6 2 A 0 1 5 9 OM4
0 6 0 A 0 2 0 9 OM4
0 8 7 A 2 0 1 1 OM4
0 6 0 A 0 1 8 6 OM4
0 6 9 A 3 0 4 5 OM4
0 6 2 A 0 9 1 2 OM4
0 6 9 A 2 1 5 9 OM4

Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request. Other connector combinations,
cable and fiber data sheets on request. 1 = Type R+M with zirconia ceramic ferrule.

ROSENBERGER OSI PRODUCT CATALOG

131

assemblies Patchcords

Duplex PATCHCORD
Cable type round I-V(ZN)H 2.0 mm FRNC-LSZH
Partnumbers
connector

LC-Compact LC-Compact
LC-Compact APC LC-Compact APC

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

Variable
Variable

087A6620G657A
087A6622G657A

0 8 7 A 6 6 2 3 OM3

0 8 7 A 6 6 2 3 OM4

Oprerating temperature range -10 C to +60 C, patchcords for other oprerating temperature ranges on request. Other connector combinations,
cable and fiber data sheets on request.

Duplex PATCHCORD
Cable type round I-V(ZN)H 2.8 mm FRNC-LSZH
Partnumbers
connector

LC-Compact LC-Compact
LC-Compact APC LC-Compact APC

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

Variable
Variable

087A6600
087A6609

0 8 7 A 6 6 0 1 OM3

0 8 7 A 6 6 0 1 OM4

Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request. Other connector combinations,
cable and fiber data sheets on request.

Duplex PATCHCORD
Cable type double-jacket-round I-V(ZN)H(ZN) 2.8/5.0 mm FRNC-LSZH
Partnumbers
connector

LC-Compact LC-Compact
LC-Compact APC LC-Compact APC

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

Variable
Variable

087A6610G657A
087A6612G657A

0 8 7 A 6 6 1 3 OM3

0 8 7 A 6 6 1 3 OM4

Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request. Other connector combinations,
cable and fiber data sheets on request.

132

ROSENBERGER OSI PRODUCT CATALOG

assemblies Patchcords

PATCHCORDS COPPER

PATCHCORDS for PreCONNECT COPPER Trunk/Multi Jumper


Partnumbers

LENGTH

Partnumbers

1m
2m
3m
5m

800A0001
800A0003
800A0005
800A0007

patchcords

Screened Cat. 6 RJ45 connectors with molded boots at Cat. 7 S/FTP FRNC-LSZH flex cable grey

Other lengths, colours and types on request.

PATCHCORDS for PreCONNECT Copper Trunk ToR


Partnumbers

Screened Cat. 6 RJ45 connectors at Cat. 7 S/FTP FRNC-LSZH flex cable grey
LENGTH

Partnumbers

1m
2m
3m
5m

800A0195
800A0196
800A0194
800A0197

Other lengths, colours and types on request.

ROSENBERGER OSI PRODUCT CATALOG

133

assemblies Pigtails

Pigtails

APPLICATIONS
Pigtails appropriate for use in data centers and office
buildings
Pigtails for other applications on request

FIBER TYPES

properties
Operating temperature range -10 C to +60 C, pigtails for
other operating temperature ranges on request

LENGTH TOLERANCES:
Up to 1 m
=
2 m to 3 m
=
4 m to 25 m
=
longer than 25 m =

134

CABLE TYPES
Available as cable pigtails and buffered-fiber pigtails
Cable data sheets on request

+/- 50 mm
+/- 100 mm
+/- 200 mm
+/- 1 %

With all standard fiber types available


Fiber data sheets on request

CONNECTORS
With all standard connectors available

DELIVERY FORM
Factory Insertion Loss (IL) measured acc. to IEC 61300-3-4
methode B, measurement report on request
Serial number label on pigtail
Each packed in a foil bag with Product ID label

ROSENBERGER OSI PRODUCT CATALOG

assemblies Pigtails

BUFFERED-FIBER PIGTAIL
Buffered-fiber type I-VH 1 x 900 m FRNC-LSZH dry compact
Partnumbers
CONNECTOR
SC
ST
MU
LC
E-2000TM1
FC PC
SC APC
MU APC
LC APC
E-2000 HRL1
FC APC

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

2.5 m
2.5 m
2.5 m
2.5 m
2.5 m
2.5 m
2.5 m
2.5 m
2.5 m
2.5 m
2.5 m

062A0053
060A0053
088A1743
087A1743
069A2053
068A0053
062A0982
088A1746
087A1746
069A2083
068A0071

0 6 2 A 0 0 1 3 OM3
0 6 0 A 0 0 1 3 OM3
0 8 8 A 1 7 4 4 OM3
0 8 7 A 1 7 4 4 OM3
0 6 9 A 2 0 1 3 OM3
0 6 8 A 0 0 1 3 OM3

0 6 2 A 0 0 1 3 OM4
0 6 0 A 0 0 1 3 OM4
0 8 8 A 1 7 4 4 OM4
0 8 7 A 1 7 4 4 OM4
0 6 9 A 2 0 1 3 OM4
0 6 8 A 0 0 1 3 OM4

Operating temperature range -10 C to +60 C, pigtails for other operating temperature ranges on request. Other connectors, cable and fiber data sheets on request.
1
= Type R+M with zirconia ceramic ferrule.

CABLE PIGTAIL
Cable type I-V(ZN) H 1x2.1 mm FRNC-LSZH

CONNECTOR
MU
LC
MU APC
LC APC

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

2.5 m
2.5 m
2.5 m
2.5 m

088A1835
087A6001
088A1836
087A6003

0 8 8 A 1 8 4 5 OM3
0 8 7 A 6 0 0 5 OM3

0 8 8 A 1 8 4 5 OM4
0 8 7 A 6 0 0 5 OM4

Pigtails

Partnumbers

Operating temperature range -10 C to +60 C, pigtails for other operating temperature ranges on request. Other connectors, cable and fiber data sheets on request.
1
= Type R+M with zirconia ceramic ferrule.

CABLE PIGTAIL
Cable type I-V(ZN)H 1x2.8 mm FRNC-LSZH
Partnumbers
CONNECTOR
SC
LC
E-2000TM1
FC PC
SC APC
LC APC
E-2000 HRL1
FC APC

LENGTH

OS2
9/125

OM3
50/125

OM4
50/125

2.5 m
2.5 m
2.5 m
2.5 m
Variable
2.5 m
2.5 m
2.5 m

062A0043
087A6011
069A2043
068A0043
062A0075
087A6013
069A2093
068A0075

0 6 2 A 0 0 0 3 OM3
0 8 7 A 6 0 1 5 OM3
0 6 9 A 2 0 0 3 OM3
0 6 8 A 0 0 0 3 OM3

0 6 2 A 0 0 0 3 OM4
0 8 7 A 6 0 1 5 OM4
0 6 9 A 2 0 0 3 OM4
0 6 8 A 0 0 0 3 OM4

Operating temperature range -10 C to +60 C, pigtails for other operating temperature ranges on request. Other connectors, cable and fiber data sheets on request.
1
= Type R+M with zirconia ceramic ferrule.

ROSENBERGER OSI PRODUCT CATALOG

135

assemblies FACTORY ASSEMBLED SPLICE CASSETTES

FACTORY ASSEMBLED SPLICE CASSETTES


with 12 fiber pigtail bundle cable

Self-adhesive tube clamp to fix


the bundle inside the panel.

1
Free single leg lengths
- adjustable during installation

APPLICATIONs
Installation in splice panels

CONNECTORS
With all standard connectors available

PROPERTIES

DELIVERY FORM

Fibers and buffer jackets in 12 different colours according


to the DIN VDE 0888 colour code thereby fast and reliable
identification and allocation of fibers inside the cassette to
the assembled connectors (1)
Easy and secure handling due to transparent bundle jacket
covering the 12 buffered-fibers

Factory Insertion Loss (IL) measured acc. to IEC 61300-3-4


methode B, measurement report on request
Serial number and product ID label
With self-adhesive tube clamp
Single packaging
Without splice holder, splice protector and cassette cover
these can be ordered separately at page 174

CABLE TYPES
Single dry 900 m buffered-fiber LB 900
Cable data sheets on request

FiBER TYPES
With all standard fiber types available
Fiber data sheets on request

136

ROSENBERGER OSI PRODUCT CATALOG

assemblies FACTORY ASSEMBLED SPLICE CASSETTES

Partnumbers

Length: 2 m

connector

NUMBER OF FIBERS

OS2
9/125

OM3
50/125

OM4
50/125

ST
SC-Simplex
LC-Simplex
E-2000TM Simplex1
E-2000TM Simplex HRL
MU-Simplex

12
12
12
12
12
12

117A4005
117A4003
117A4014
117A4008
117A4009
117A4015

1 1 7 A 4 1 0 5 OM3
1 1 7 A 4 1 0 3 OM3
1 1 7 A 4 1 1 4 OM3
1 1 7 A 4 1 0 8 OM3

1 1 7 A 4 1 1 5 OM3

1 1 7 A 4 1 0 5 OM4
1 1 7 A 4 1 0 3 OM4
1 1 7 A 4 1 1 4 OM4
1 1 7 A 4 1 0 8 OM4

1 1 7 A 4 1 1 5 OM4

Other connectors, cable and fiber data sheets on request. 1 = Type R+M with zirconia ceramic ferrule.

FACTORY ASSEMBLED SPLICE CASSETTES

ROSENBERGER OSI PRODUCT CATALOG

137

138

ROSENBERGER OSI PRODUCT CATALOG

Panels and Racks

ROSENBERGER OSI PRODUCT CATALOG

139

panels

140

ROSENBERGER OSI PRODUCT CATALOG

PANELS AND RACKs: PANELS

Thinking about the need of panels choose


Rosenberger OSI the best ever. From classical
distribution to modular multifunctional panels
or highly flexible module panels our easy to
install 19 panels are designed to fulfill your
demands and to fit perfectly into each structured cabling. Even where no 19 applications
are available or necessary, you can rely on the

ROSENBERGER OSI PRODUCT CATALOG

panel hardware from Rosenberger OSI. Whether


universal panels or special requirements from
customers e.g. the explosion protected wallcabinet for use in mining (see page 31) we offer
distribution units for all environmental conditions to safely protect the sensitive fiber optic
components.

141

panels

19 1 Hu and 2 Hu distribution panel

1 Hu for up to 24 channels (48 Fibers)

Type: fixed installation

Type: telescopic full-pullout

2 Hu for up to 48 channels (96 Fibers)

Type: fixed installation

Type: telescopic full-pullout

142

ROSENBERGER OSI PRODUCT CATALOG

panels

dimensions 1 Hu

dimensions 2 Hu

telescopic full-pullout

telescopic full-pullout

Optional: 19 3 HU distribution panel


on request

APPLICATIONS

properties
Basic panel with optimized functionality
Suitable to accept all cables assembled by
Rosenberger OSI
Available in two types:
Fixed installation
Telescopic full-pullout: can be pulled out completely
Torsion and strain resistant cable supports for
2 PreCONNECT Trunk cable dividers for 1 HU
4 PreCONNECT Trunk cable dividers for 2 HU
2 PG 21 (29 mm) cable inputs
Cable guidance 45 slant backwards, lead-way to be selected
2 universal supports for simplex, duplex and breakout
cables available, see accessories pages 144/145
Screen print front plate labeling:
numerical and alphanumerical
Material and colour:
Body: aluminium, nature
Front: aluminium powder coated, RAL 7035 (lightgrey)

ROSENBERGER OSI PRODUCT CATALOG

Weight (panel without couplers):


Fixed installation: 1 HU - 1120 g

2 HU - 1580 g
Telescopic full-pullout: 1 HU - 1600 g

2 HU - 2140 g

3
panels

For installation in 19 racks


To interconnected e.g. PreCONNECT FIBER Trunks
with patchcords

delivery form



Panel completely factory assembled


Mounted couplers
Blind covers in unused cable inputs
Blind covers in unused front plate ports

accessories
See pages 144/145 and 174177

143

panels

19 1 hu distribution panel
Partnumbers

1 HU RAL 7035 (lightgrey)


fiber count

type of coupler

fixed installation

telescopic full-pullout

SM

MM

SM

MM

12

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
E-2000E-2000 Simplex1 HRL
LCLC-Duplex SM
OM3
OM4

231A0183

231A0153
231A0420

231A1003
231A0173

2 3 1 A 1 6 0 3 OM3
2 3 1 A 1 6 0 3 OM4
231A0013

2 3 1 A 04 4 0 OM3
2 3 1 A 04 4 0 OM4

2 3 1 A 1 2 9 3 OM3
2 3 1 A 1 2 9 3 OM4

230A0183

230A0153
230A0420

230A1003
230A0173

2 3 0 A 1 6 0 3 OM3
2 3 0 A 1 6 0 3 OM4
230A0013

2 3 0 A 0 4 4 0 OM3
2 3 0 A 0 4 4 0 OM4

2 3 0 A 1 2 9 3 OM3
2 3 0 A 1 2 9 3 OM4

24

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
E-2000E-2000 Simplex1 HRL
LCLC-Duplex SM
OM3
OM4

231A0185

231A0155
231A0421

231A1005
231A0175

2 3 1 A 1 6 0 5 OM3
2 3 1 A 1 6 0 5 OM4
231A0015

2 3 1 A 0 4 4 1 OM3
2 3 1 A 0 4 4 1 OM4

2 3 1 A 1 2 9 5 OM3
2 3 1 A 1 2 9 5 OM4

230A0185

230A0155
230A0421

230A1005
230A0175

2 3 0 A 1 6 0 5 OM3
2 3 0 A 1 6 0 5 OM4
230A0015

2 3 0 A 0 4 4 1 OM3
2 3 0 A 0 4 4 1 OM4

2 3 0 A 1 2 9 5 OM3
2 3 0 A 1 2 9 5 OM4

48

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
LCLC-Duplex SM
OM3
OM4

231A0187

231A0158
231A0422

231A0177

2 3 1 A 1 6 0 7 OM3
2 3 1 A 1 6 0 7 OM4
231A0018

2 3 1 A 0 4 4 2 OM3
2 3 1 A 0 4 4 2 OM4

2 31 A 1 2 9 8 OM3
2 31 A 1 2 9 8 OM4

230A0187

230A0158
230A0422

230A0177

2 3 0 A 1 6 0 7 OM3
2 3 0 A 1 6 0 7 OM4
230A0018

2 3 0 A 0 4 4 2 OM3
2 3 0 A 0 4 4 2 OM4

2 3 0 A 1 2 9 8 OM3
2 3 0 A 1 2 9 8 OM4

More couplers and fiber counts on request. 1 = Type R+M.

Partnumbers accessories 1 HU
Tertiary cable support
Standard

1 pcs.

111A0403

Tertiary cable support


Large, with brush

1 pcs.

111A0418

Support for
4 PreCONNECT Trunks

1 set = 2 plates

111A0416

Support (straight) for


6 PreCONNECT Trunks

1 set = 2 plates

111A0425

1 HU labeling field 30 x 35 mm

1 pcs.

111A0415

More accessories see pages 174177.

144

ROSENBERGER OSI PRODUCT CATALOG

panels

19 2 hu distribution panel
Partnumbers

2 HU RAL 7035 (lightgrey)


fiber count

type of coupler

fixed installation

telescopic full-pullout

SM

MM

SM

MM

48

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
E-2000E-2000 Simplex1 HRL
LCLC-Duplex SM
OM3
OM4

235A1527

235A0157
235A0180

235A1007
235A1287

2 3 5 A 1 5 4 7 OM3
2 3 5 A 1 5 4 7 OM4
235A0017

2 3 5 A 0 4 0 0 OM3
2 3 5 A 0 4 0 0 OM4

2 3 5 A 1 3 1 7 OM3
2 3 5 A 1 3 1 7 OM4

234A1527

234A0157
234A0180

234A1007
234A1287

2 3 4 A 1 5 4 7 OM3
2 3 4 A 1 5 4 7 OM4
234A0017

2 3 4 A 0 4 0 0 OM3
2 3 4 A 0 4 0 0 OM4

2 3 4 A 1 3 1 7 OM3
2 3 4 A 1 3 1 7 OM4

96

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
LCLC-Duplex SM
OM3
OM4

235A1530

235A0168
235A0181

235A1289

2 3 5 A 1 5 5 0 OM3
2 3 5 A 1 5 5 0 OM4
235A0019

2 3 5 A 0 4 0 1 OM3
2 3 5 A 0 4 0 1 OM4

2 3 5 A 1 3 1 9 OM3
2 3 5 A 1 3 1 9 OM4

234A1530

234A0168
234A0181

234A1289

2 3 4 A 1 5 5 0 OM3
2 3 4 A 1 5 5 0 OM4
234A0019

2 3 4 A 0 4 0 1 OM3
2 3 4 A 0 4 0 1 OM4

2 3 4 A 1 3 1 9 OM3
2 3 4 A 1 3 1 9 OM4

3
panels

More couplers and fiber counts on request. 1 = Type R+M.

Partnumbers

accessories 2 HU
Tertiary cable support
Standard

1 pcs.

111A0403

Tertiary cable support


Large, with brush

1 set = 2 pcs.

111A0611

Support for
8 PreCONNECT Trunks

1 set = 4 plates

111A0612

Support (straight) for


12 PreCONNECT Trunks

1 set = 4 plates

111A0613

2 HU labeling field
30 x 88 mm

1 pcs.

111A0610

More accessories see pages 174177.

ROSENBERGER OSI PRODUCT CATALOG

145

panels

19 1 HU and 2 HU Splice panel

1 HU for up to 24 channels (48 Fibers)

Type: fixed installation

Type: telescopic full-pullout

2 HU for up to 48 channels (96 Fibers)

Type: fixed installation

Type: telescopic full-pullout

146

ROSENBERGER OSI PRODUCT CATALOG

panels

Dimensions 1 HU

Dimensions 2 HU

telescopic full-pullout

telescopic full-pullout

applications

optional

For installation in 19 racks

With splice cassettes, holders, protectors and cable


glands, see pages 174177
Pigtails ready for splicing laid in (fiber counts to be divided
by 12 are delivered with factory assembled splice
cassettes, see pages 136/137)

ROSENBERGER OSI PRODUCT CATALOG

delivery form



panels

properties
Basic panel with optimized functionality
For splicing of all standard types of pigtails on all standard
types of cables
The panel is available in two types:
Fixed installation
Telescopic full-pullout: can be pulled out completely
Twist secure supports for max. 4 splice cassettes in 1 HU
for max. 8 splice cassettes in 2 HU, cassette type see
accessories page 174
2 PG21 (29 mm) cable inputs cable guidance 45 slant
backwards, lead-way to be selected
2 universal supports for simplex-, duplex- and breakout
cables available, see accessories pages 148/149
Screen print front plate labeling:
numerical and alphanumerical
Material and colour:
Body: aluminium natural
Front: aluminium powder coated, RAL 7035 (lightgrey)
Weight (panel without couplers and cassettes):
Fixed installation:
1 HU - 1120 g

2 HU - 1580 g
Telescopic full-pullout: 1 HU - 1600 g

2 HU - 2140 g

Panel factory assembled incl. couplers


Blind covers in unused cable inputs
Blind covers in unused front plate ports
Including splice cassette cover

Accessories
See pages 148 /149 and 174177
Factory assembled splice cassettes see pages 136/137
Pigtails see pages 134/135

147

panels

19 1 Hu Splice panel

Partnumbers

1 HU RAL 7035 (lightgrey)


fiber count

fixed installation

type of coupler

telescopic full-pullout

SM

MM

SM

MM

12

MU MU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
E-2000E-2000 Simplex1 HRL
LCLC-Duplex SM
OM3
OM4

231A0363

231A0333
231A1590

231A1103
231A0353

2 3 1 A 1 5 8 3 OM3
2 3 1 A 1 5 8 3 OM4
231A0213

2 3 1 A 1 6 6 0 OM3
2 3 1 A 1 6 6 0 OM4

2 3 1 A 1 3 2 3 OM3
2 3 1 A 1 3 2 3 OM4

230A0363

230A0333
230A1590

230A1103
230A0353

2 3 0 A 1 5 8 3 OM3
2 3 0 A 1 5 8 3 OM4
230A0213

2 3 0 A 1 6 6 0 OM3
2 3 0 A 1 6 6 0 OM4

2 3 0 A 1 3 2 3 OM3
2 3 0 A 1 3 2 3 OM4

24

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
E-2000E-2000 Simplex1 HRL
LCLC-Duplex SM
OM3
OM4

231A0365

231A0335
231A1591

231A1105
231A0355

2 3 1 A 1 5 8 5 OM3
2 3 1 A 1 5 8 5 OM4
231A0215

2 3 1 A 1 6 6 1 OM3
2 3 1 A 1 6 6 1 OM4

2 3 1 A 1 3 2 5 OM3
2 3 1 A 1 3 2 5 OM4

230A0365

230A0335
230A1591

230A1105
230A0355

2 3 0 A 1 5 8 5 OM3
2 3 0 A 1 5 8 5 OM4
230A0215

2 3 0 A 1 6 6 1 OM3
2 3 0 A 1 6 6 1 OM4

2 3 0 A 1 3 2 5 OM3
2 3 0 A 1 3 2 5 OM4

48

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
LCLC-Duplex SM
OM3
OM4

231A0368

231A0339
231A1592

231A0358

2 3 1 A 1 5 8 7 OM3
2 3 1 A 1 5 8 7 OM4
231A0219

2 3 1 A 1 6 6 2 OM3
2 3 1 A 1 6 6 2 OM4

2 3 1 A 1 3 2 8 OM3
2 3 1 A 1 3 2 8 OM4

230A0368

230A0339
230A1592

230A0358

2 3 0 A 1 5 8 7 OM3
2 3 0 A 1 5 8 7 OM4
230A0219

2 3 0 A 1 6 6 2 OM3
2 3 0 A 1 6 6 2 OM4

2 3 0 A 1 3 2 8 OM3
2 3 0 A 1 3 2 8 OM4

More connectivity systems and fiber counts on request. 1 = Type R+M.

Partnumbers accessories 1 HU
Tertiary cable supports
Standard

1 pcs.

111A0403

Tertiary cable supports


Large, with brush

1 pcs.

111A0418

Support for
6 cable glands up to PG 16

1 set = 2 plates
(without cable glands)

111A0417

1 HU labeling field 30 x 35 mm

1 pcs.

111A0415

More accessories see pages 174177.

148

ROSENBERGER OSI PRODUCT CATALOG

panels

19 2 HU Splice panel

Partnumbers

2 HU RAL 7035 (lightgrey)


fiber count

fixed installation

type of coupler

telescopic full-pullout

SM

MM

SM

MM

48

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
E-2000E-2000 Simplex1 HRL
LCLC-Duplex SM
OM3
OM4

235A1568

235A0338
235A0450

235A1108
235A0378

2 3 5 A 1 5 8 8 OM3
2 3 5 A 1 5 8 8 OM4
235A0218

2 3 5 A 0 5 0 0 OM3
2 3 5 A 0 5 0 0 OM4

2 3 5 A 1 3 2 8 OM3
2 3 5 A 1 3 2 8 OM4

234A1568

234A0338
234A0450

234A1108
234A0378

2 3 4 A 1 5 8 8 OM3
2 3 4 A 1 5 8 8 OM4
234A0218

2 3 4 A 0 5 0 0 OM3
2 3 4 A 0 5 0 0 OM4

2 3 4 A 1 3 2 8 OM3
2 3 4 A 1 3 2 8 OM4

96

MUMU-Duplex-Horizontal SM
OM3
OM4
SCSC-Duplex metal
SC-DuplexSC-Duplex plastic SM
OM3
OM4
LCLC-Duplex SM
OM3
OM4

235A1571

235A1513
235A0451

235A0381

2 3 5 A 1 5 9 1 OM3
2 3 5 A 1 5 9 1 OM4
235A1512

2 3 5 A 0 5 0 1 OM3
2 3 5 A 0 5 0 1 OM4

2 3 5 A 1 3 3 1 OM3
2 3 5 A 1 3 3 1 OM4

234A1571

234A1513
234A0451

234A0381

2 3 4 A 1 5 9 1 OM3
2 3 4 A 1 5 9 1 OM4
234A1512

2 3 4 A 0 5 0 1 OM3
2 3 4 A 0 5 0 1 OM4

2 3 4 A 1 3 3 1 OM3
2 3 4 A 1 3 3 1 OM4

3
panels

More connectivity systems and fiber counts on request. 1 = Type R+M.

Partnumbers

accessories 2 HU
Tertiary cable supports
Standard

1 pcs.

111A0403

Tertiary cable supports


Large, with brush

1 set = 2 pcs.

111A0611

Support for
6 cable glands up to PG 16

1 set = 4 plates
(without cable glands)

111A0614

2 HU labeling field
30 x 88 mm

1 pcs.

111A0610

More accessories see pages 174177.

ROSENBERGER OSI PRODUCT CATALOG

149

panels

19 3 Hu distribution module panel

applications
For installation in 19 racks
To interconnect e.g. PreCONNECT FIBER Trunks with
patchcords

properties
Highly flexible and universal applicable panel by
its modular front plates and back planes
Suitable to accept all by Rosenberger OSI
assembled cables
For up to 144 channels (288 fibers)
With cut out pattern acc. to IEC 60297-3 in 84 dividing
units (DU)
To accept up to 12 individual 3 HU - 7 DU part front plates
Available with two back plane types:
1. Z-blade-back plane designed to accept 12 of our
PreCONNECT FIBER Trunks
2. Tertiary cable back plane to support simplex-,
duplex- and break out cables with cable ties
Back plane types as described above and shown on
page 151
The module panel is a modular platform for different
connectivity systems and FO fiber types

150

Matrix numbering of the part front plates (PFPs):


channels in PFPs = 1 to n in labeling fields
PFPs in module panel = 1 to n number clips
(example: channel 3-4 means in PFP 3 channel 4)
Material and colour:
body and front: aluminium, available in silver anodized
or RAL 9005 (black) version
Weight:
Module panel unassembled approx.: 2.0 kg
Part front plate assembled approx.: 0.1 kg

delivery form
Part front plates factory assembled incl. FO couplers,
labeling and screws
Module panel factory assembled with corresponding
back plane

accessories
See pages 174177

ROSENBERGER OSI PRODUCT CATALOG

panels

dimensions

Depth selectable 236 mm or 295 mm

Partnumbers

single components

19 3 HU distribution module panel


With Z-blade back plane designed to accept
12 PreCONNECT Trunks
236 mm deep, front silver
236 mm deep, front black
295 mm deep, front silver
295 mm deep, front black

141A0000
141A3000
141A1500
141A3500

236 mm deep, front silver


295 mm deep, front black

panels

19 3 HU distribution module panel


Tertiary cable back plane

141A0007
On request

Silver
Black

3 HU-7 DU BLIND PART FRONT PLATE

141A0002
141A3010

3 HU-7 DU patch field part front plates


Assembled with couplers
fiber
count

colour of
front

12

Silver
Black
Silver
Black

24

Silver
Black
Silver
Black

SM

OM3

OM4

SCSC-Duplex metal
SCSC-Duplex metal
E-2000E-2000 HRL1
E-2000E-2000 HRL1

141A0143
141A3051
141A0813
On request

1 4 1 A 0 0 4 3 OM3
1 4 1 A 3 0 5 0 OM3

On request

1 4 1 A 0 0 4 3 OM4
1 4 1 A 3 0 5 0 OM4

On request

MUMU-Duplex-Horizontal
MUMU-Duplex-Horizontal
LCLC-Duplex
LCLC-Duplex

141A0175
141A3041
141A0135
141A3031

1 4 1 A 0 1 8 5 OM3
1 4 1 A 3 0 4 0 OM3
1 4 1 A 0 1 6 5 OM3
1 4 1 A 3 0 3 0 OM3

1 4 1 A 0 1 8 5 OM4
1 4 1 A 3 0 4 0 OM4
1 4 1 A 0 1 6 5 OM4
1 4 1 A 3 0 3 0 OM4

type of coupler

Further couplers and fiber counts on request. 1 = Type R+M.

ROSENBERGER OSI PRODUCT CATALOG

151

panels

19 3+1 Hu splice module panel

3 HU

1 HU tray

1 HU

3 +1 HU

3 HU module panel

applications
For installation in 19 racks

properties
Very installation and service friendly
Appropriate for splice cabling with a high number of fibers
With cut out pattern acc. to IEC 60297-3 in 84 dividing
units (DU)
For up to 144 channels (288 fibers)
To accept up to 12 individual 3 HU 7 DU splice plug-in
modules
Up to 12 single loose tube cables can be fixed in the 1 HU
tray with 11 x PG 16 and 1 x PG 21 cable glands, see page
153
Cable guidance straight backwards
The loose tube reserve is stored inside the 1 HU tray
and guided towards the modules by protection tubes
These tubes protect loose tubes against kinking
while installing the splice plug-in modules
The modules are guided by guide rails inside the enclosure
and can be pulled out completely
The module panel is a modular platform for different
connectivity systems and FO types
Matrix numbering of the modules:
channels in modules: 1 to n in labeling fields,
modules in module panel: 1 to n number clips

152

(example: channel 3-4 means in module 3 channel 4)


Material and colour:
body and front: aluminium, silver anodized
Weight:
Module panel unassembled
approx. 2.0 kg
Splice plug-in module
approx. 0.5 kg

delivery form
Splice plug-in modules factory assembled incl.:
Ready for splicing buffered fiber pigtails
FO couplers
Splice holders and protectors
Cassette cover
Labeling field and screws
Loose tube protection tube with mounting material
Module panel completely factory assembled with
1 HU tray without cable glands

accessories
See pages 174177

ROSENBERGER OSI PRODUCT CATALOG

panels

dimensions

DU

back view:
cable glands on 1 HU tray

1x
PG 21

6 x PG 16

panels

5 x PG 16

Partnumbers

single components
19 3 HU splice module panel
For splice plug-in modules
incl. 1 HU tray with patchcord guide

141A0001

3 HU - 7 DU blind part front plate

silver
black

141A0002
141A3010

3 HU - 7 DU splice plug-in modules incl. assembled pigtails


fiber count

type of coupler

SM OS2

OM3

OM4

12

SCSC-Duplex metal
E-2000 HRL1 E-2000 HRL1

141A0513
141A0833

1 4 1 A 0 6 1 3 OM3

1 4 1 A 0 6 1 3 OM4

24

MUMU-Duplex-Horizontal
LCLC-Duplex

141A0935
141A0885

1 4 1 A 0 9 4 5 OM3
1 4 1 A 0 8 9 5 OM3

1 4 1 A 0 9 4 5 OM3
1 4 1 A 0 8 9 5 OM3

Further couplers and fiber counts on request. 1 = Type R+M.

ROSENBERGER OSI PRODUCT CATALOG

153

Panels

19 SMAP DISTRIBUTION PANEL

19 : 4 8

1 HU

2 HU

Standard back plane configuration


for max. 12 cable dividers per panel.

: 44

: 88

3 mm

mm

mm

Other back plane types see


pages 160/161.

3 HU

4 HU

30 0

: 132

: 176

mm

mm

mm

Labeling fields

APPLICATIONS
For installation in 19 racks
To interconnect e.g. PreCONNECT FIBER Trunks with
patchcords in data centers

PROPERTIES
Maximum of modularity and flexibility due to application
specific combinable 1/2 and 1/3 part front plates
Very robust panel at low weight
Suitable to accept all cables assembled by
Rosenberger OSI
1 to 4 HU assembled with 1 HU 1/2 or 1/3 part front plates
(PFP) depending on the number of fibers and coupler type
Matrix numbering of the PFPs:
channels within PFPs are labeled 1 to n, PFPs within the
panel are labeled 1 to n with clips (e.g.: channel 3 4 means in PFP 3 channel 4)

154

Material and colour:


Front: steel, powder coated RAL 9005 (black)
Body: aluminium
Back planes: steel, powder coated RAL 9005 (black)

delivery form
Completely factory assembled incl. couplers

ACCESSORIES
Part front plates (PFP) see page 155
Back plane types see pages 160 / 161
Labeling fields see page 176

ROSENBERGER OSI PRODUCT CATALOG

Panels

PARTNUMBERS

SINGLE COMPONENTS
19 SMAP DISTRIBUTION PANEL
To accept SMAP part front plates, RAL 9005 (black)
1 HU
2 HU
3 HU
4 HU

161A0001
162A0001
163A0001
164A0001

SMAP 1/3 PART FRONT PLATE


RAL 9005 (black)
BLIND PART FRONT PLATE

160A0001
FIBER TYPE

NUMBER OF
CHANNELS/
FIBERS

COUPLER TYPE

8 CH / 16 F

LC-Duplex

SM

OM3

OM4

160A0090

1 6 0 A 0 1 0 0 OM3

1 6 0 A 0 1 0 0 OM4

SMAP 1/2-PART FRONT PLATE


RAL 9005 (black)
BLIND PART FRONT PLATE

160A0002

COUPLER TYPE

12 CH / 24 F

SM

OM3

OM4

LC-Duplex

160A0120

1 6 0 A 0 1 3 0 OM3

1 6 0 A 0 1 3 0 OM4

18 CH / 36 F

LC-Duplex

160A0135

1 6 0 A 0 1 4 0 OM3

1 6 0 A 0 1 4 0 OM4

24 CH / 48 F

MU-Duplex-Horizontal

160A0400

1 6 0 A 0 4 1 0 OM3

1 6 0 A 0 4 1 0 OM4

12 x 2 = 24 CH /
48 F

LC-Quad

160A0430

1 6 0 A 0 4 4 0 OM3

1 6 0 A 0 4 4 0 OM4

Panels

FIBER TYPE

NUMBER OF
CHANNELS/
FIBERS

Further coupler types and numbers of fibers on request.

ROSENBERGER OSI PRODUCT CATALOG

155

Panels

19 SMAP SPLICE PANEL

19 : 4 8
Standard back plane configuration
for max. 4 splice cassettes (SPC) per
height unit (HU) and 6 PG21 cable
glands per panel.

1 HU

: 44

1 HU = 4 SPC
2 HU = 8 SPC
3 HU = 12 SPC

mm

Other back plane types see pages


160/161.

2 HU

3 HU

30 0

: 88

: 132

mm

mm

mm

APPLICATIONs

OPTIONal

For installation in 19 racks

Splice cassettes, holders, protectors and cable glands,


see pages 174 177
Pigtails ready for splicing laid in (fiber counts to be divided
by 12 are delivered with factory assembled splice
cassettes, see pages 136/137)

PROPERTIEs
Maximum of modularity and flexibility due to application
specific combinable 1/2 and 1/3 part front plates
Very robust panel at low weight
Appropriate for all standard pigtail and cable types
1 to 3 HU assembled with 1 HU 1/2 or 1/3 part front plates
(PFP) depending on the number of fibers and coupler type
Matrix numbering of PFPs: channels within PFPs are labeled
1 to n PFPs within the panel are labeled 1 to n with clips
(e.g.: channel 3-4 means in PFP 3 channel 4)
Material and colour:
Front: steel, powder coated RAL 9005 (black)
Body: aluminium
Back planes: steel, powder coated RAL 9005 (black)

156

3 mm

delivery form:
Completely factory assembled incl. couplers and
Splice-Cassette-Holder with cover

ACCESSORIES




Pigtails see pages 134 / 135


Factory assembled splice cassettes see pages 136 / 137
Part front plates (PFP) see page 155
Back plane types see pages 160 / 161
Labeling fields see page 176

ROSENBERGER OSI PRODUCT CATALOG

Panels

PARTNUMBERS

19 SMAP SPLICE PANELS


NUMBER OF

FOR FIBER TYPE

HU

COUPLER TYPE

CHANNELS

FIBERS

PFP TYPE

SM

OM3

OM4

MU-Duplex-Horizontal

4
6
8
12
16
18
24
32
36
48

8
12
16
24
32
36
48
64
72
96

1 x 1/2
1 x 1/2
1 x 1/2
1 x 1/2
1 x 1/2
1 x 1/2
1 x 1/2
2 x 1/2
2 x 1/2
2 x 1/2

161A3080
161A3081
161A3082
161A3083
161A3084
161A3085
161A3086
161A3087
161A3088
161A3089

1 6 1 A 3 0 9 0 OM3
1 6 1 A 3 0 9 1 OM3
1 6 1 A 3 0 9 2 OM3
1 6 1 A 3 0 9 3 OM3
1 6 1 A 3 0 9 4 OM3
1 6 1 A 3 0 9 5 OM3
1 6 1 A 3 0 9 6 OM3
1 6 1 A 3 0 9 7 OM3
1 6 1 A 3 0 9 8 OM3
1 6 1 A 3 0 9 9 OM3

1 6 1 A 3 0 9 0 OM4
1 6 1 A 3 0 9 1 OM4
1 6 1 A 3 0 9 2 OM4
1 6 1 A 3 0 9 3 OM4
1 6 1 A 3 0 9 4 OM4
1 6 1 A 3 0 9 5 OM4
1 6 1 A 3 0 9 6 OM4
1 6 1 A 3 0 9 7 OM4
1 6 1 A 3 0 9 8 OM4
1 6 1 A 3 0 9 9 OM4

LC-Duplex

4
6
8
12
16
18
24

8
12
16
24
32
36
48

1 x 1/3
1 x 1/3
1 x 1/3
1 x 1/2 (12)
2 x 1/3
2 x 1/2 (12)
2 x 1/2 (12)

161A3020
161A3021
161A3022
161A3043
161A3024
161A3045
161A3046

1 6 1 A 3 0 3 0 OM3
1 6 1 A 3 0 3 1 OM3
1 6 1 A 3 0 3 2 OM3
1 6 1 A 3 0 5 3 OM3
1 6 1 A 3 0 3 4 OM3
1 6 1 A 3 0 5 5 OM3
1 6 1 A 3 0 5 6 OM3

1 6 1 A 3 0 3 0 OM4
1 6 1 A 3 0 3 1 OM4
1 6 1 A 3 0 3 2 OM4
1 6 1 A 3 0 5 3 OM4
1 6 1 A 3 0 3 4 OM4
1 6 1 A 3 0 5 5 OM4
1 6 1 A 3 0 5 6 OM4

SC-Duplex Metal

4
6
8
12

8
12
16
24

1 x 1/3
1 x 1/2
2 x 1/3
2 x 1/2

161A3060
161A3071
161A3062
161A3073

1 6 1 A 3 0 6 5 OM3
1 6 1 A 3 0 7 6 OM3
1 6 1 A 3 0 6 7 OM3
1 6 1 A 3 0 7 8 OM3

1 6 1 A 3 0 6 5 OM4
1 6 1 A 3 0 7 6 OM4
1 6 1 A 3 0 6 7 OM4
1 6 1 A 3 0 7 8 OM4

MU-Duplex-Horizontal

64
72
96

128
144
192

3 x 1/2
3 x 1/2
4 x 1/2

162A3100
162A3101
162A3102

1 6 2 A 3 1 1 0 OM3
1 6 2 A 3 1 1 1 OM3
1 6 2 A 3 1 1 2 OM3

1 6 2 A 3 1 1 0 OM4
1 6 2 A 3 1 1 1 OM4
1 6 2 A 3 1 1 2 OM4

LC-Duplex

32
36
48

64
72
96

4 x 1/3
3 x 1/2 (12)
4 x 1/2 (12)

162A3020
162A3041
162A3042

1 6 2 A 3 0 3 0 OM3
1 6 2 A 3 0 5 1 OM3
1 6 2 A 3 0 5 2 OM3

1 6 2 A 3 0 3 0 OM4
1 6 2 A 3 0 5 1 OM4
1 6 2 A 3 0 5 2 OM4

SC-Duplex Metal

16
18
24

32
36
48

4 x 1/3
3 x 1/2
4 x 1/2

162A3050
162A3081
162A3082

1 6 2 A 3 0 7 0 OM3
1 6 2 A 3 0 9 1 OM3
1 6 2 A 3 0 9 2 OM3

1 6 2 A 3 0 7 0 OM4
1 6 2 A 3 0 9 1 OM4
1 6 2 A 3 0 9 2 OM4

MU-Duplex-Horizontal

144

288

6 x 1/2

163A3100

1 6 3 A 3 1 1 0 OM3

1 6 3 A 3 1 1 0 OM4

LC-Duplex

64
72

128
144

8 x 1/3
6 x 1/2 (12)

163A3020
163A3041

1 6 3 A 3 0 3 0 OM3
1 6 3 A 3 0 5 1 OM3

1 6 3 A 3 0 3 0 OM4
1 6 3 A 3 0 5 1 OM4

SC-Duplex Metal

32
36

64
72

8 x 1/3
6 x 1/2

163A3060
163A3081

1 6 3 A 3 0 7 0 OM3
1 6 3 A 3 0 9 1 OM3

1 6 3 A 3 0 7 0 OM4
1 6 3 A 3 0 9 1 OM4

3
Panels

Type

Further coupler types and numbers of fibers on request.

ROSENBERGER OSI PRODUCT CATALOG

157

Panels

19 SMAP DISTRIBUTION PANEL WITH MTP MODULES

19 : 4 8

1 HU

2 HU

Standard back plane configuration


for max. 12 cable dividers per panel.

: 44

: 88

3 mm

mm

mm

Other back plane types see page 160/161.

3 HU

: 132

4 HU

30 0

mm

176
m

mm

Labeling fields

APPLICATIONS
For installation in 19 racks
To separate the 6 MTP connector channels into
connectors of the patchfield, like e.g. LC-Duplex.

PROPERTIES
Maximum of modularity and flexibility due to application
of specific combinable 1/2 and 1/3 part front plates
Very robust panel at low weight
Light propagation uncrossed (straight) to maintain the
channelwise cross (pairwise flip) of our MTP trunk cables
With MTP modules to attach PreCONNECT FIBER Trunks
with MTP connectors (12 fibers)
MTP type in module back plane: 12 fibers;
Guide-Pins: male (MTP trunks are female by default)
1 to 4 HU assembled with 1 HU 1/2 or 1/3 part front plates
(PFP) depending on the number of fibers and coupler type
Matrix numbering of PFPs: channels within PFPs are
1 to n labeled, PFPs within the panel are numbered 1 to n
with clips (e.g.: channel 3 4 means in PFP 3 channel 4)

Material and colour:


Front: steel, powder coated RAL 9005 (black)
Body: aluminium
Back planes: steel, powder coated RAL 9005 (black)

delivery form:
Completely factory assembled incl. couplers

ACCESSORIES
Part front plates (PFP) see page 155
Back plane parts see pages 160 / 161
Labeling fields see page 176

MTP is a registered trademark of US-Conec Ltd.

158

ROSENBERGER OSI PRODUCT CATALOG

Panels

MTP connectors of the PreCONNECT MTP


Trunks are without pins (female).

Interfaces at module back plane have


pins (male).

PARTNUMBERS

SINGLE COMPONENTS
19 SMAP DISTRIBUTION PANEL
RAL 9005 (black)
1 HU
2 HU
3 HU
4 HU

161A0001
162A0001
163A0001
164A0001

SMAP MTP MODULES


(with 12 F MTP), RAL 9005 (black)
fibertype

NUMBER OF
CHANNELS/
FIBERS

COUPLER TYPE

12 CH / 24 F

LC-Duplex

2 MTP

1 6 0 A 1 3 0 0 1 6 0 A 1 3 0 5 OM3 1 6 0 A 1 3 0 5 OM4

18 CH / 36 F

LC-Duplex

3 MTP

160A1301

1 6 0 A 1 3 0 6 OM3

1 6 0 A 1 3 0 6 OM4

24 CH / 48 F

LC-Quad

4 MTP

160A1302

1 6 0 A 1 3 0 7 OM3

1 6 0 A 1 3 0 7 OM4

NUMBER OF
MTPs IN BACK
PLANE

Panels

On demand we deliver factory assembled panels with MTP plug-in modules.

SM OS 2

OM3

OM4

Further coupler types and numbers of fibers on request. MTP is a registered trademark of US-Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

159

Panels

SMAP Panel ACCESSORIES

Partnumbers
19 1 HU SMAP Front-Tray-Plate
Empty, for assembling with PFPs
as feedthrough front plate
RAL 9005 (black)

161A0007

19 1 HU SMAP Tray empty with cable fixing


For assembling with PFPs
as feedthrough panel
RAL 9005 (black)

161A5001

19 1 HU SMAP front labeling stripes


For 1 to n numbering. Set contains the plastic labeling
field support, the number-stripes and the screws.
Adding of own labeled stripes possible.
For 1/3 PFP front 1 to 24 (3 stripes)
For 1/2 PFP front 1 to 24 (2 stripes)

160A1523
160A1538

The labeling stripes do not fit at fronts with MU-Duplex, SC-Duplex and
LC-Quad. Other sets, e.g. 1 to 48 for 2 HU panel ect. on request

160

19 1 HU SMAP Panel back plane


Blind,
RAL 9005 (black)

160A1501

19 1 HU SMAP Panel back plane


With 12 PreCONNECT square interfaces,
RAL 9005 (black)

160A1502

19 1 HU SMAP Panel back plane


With 16 PreCONNECT square interfaces,
RAL 9005 (black)

160A1503

19 1 HU SMAP Panel back plane Z-blade


With 4 PreCONNECT square interfaces,
central cable routing,
RAL 9005 (black)

160A1512

19 1 HU SMAP Panel back plane Z-blade


With 4 PreCONNECT square interfaces,
cable routing sideways,
RAL 9005 (black)

160A1516

ROSENBERGER OSI PRODUCT CATALOG

Panels

Partnumbers

160A1515

19 1 HU Panel back plane for combined FO and


Copper cabling
On the left universal support of cables with cable ties,
on the right Z-blade with 2 PreCONNECT square
interfaces, center cable routing,
RAL 9005 (black)

160A1517

19 1 HU Panel back plane for combined FO and


Copper cabling
On the left Z-blade with 2 PreCONNECT square
interfaces, cable routing sideways, on the right universal
support of cables with cable ties,
RAL 9005 (black)

160A1518

19 1 HU Panel back plane for combined FO and


Copper cabling
On the left universal support of cables with cable ties,
on the right Z-blade with 2 PreCONNECT square
interfaces, cable routing sideways,
RAL 9005 (black)

160A1519

19 1 HU SMAP Panel back plane


For universal mounting of cables with cable ties,
RAL 9005 (black)

160A1507

19 1 HU SMAP Panel back plane


With 8 x 29 mm holes suitable for PG21 cable glands,
RAL 9005 (black)

160A1504

19 1 HU SMAP Panel back plane for Splice-Panels


With 6 x 29 mm holes suitable for PG 21 cable glands
and support for 4 standard splice cassettes, with splice
cassette cover,
RAL 9005 (black)

160A1505

19 1 HU SMAP Splice-Cassette-Modul
For mounting (stacking) at panel back plane for splice
panels in panels higher than 1 HU,
capacity for 4 standard splice cassettes, without splice
cassette cover,
RAL 9005 (black)

160A1506

ROSENBERGER OSI PRODUCT CATALOG

3
Panels

19 1 HU Panel back plane for combined FO and


Copper cabling
On the left Z-blade with 2 PreCONNECT square
interfaces, center cable routing on the right universal
support of cables with cable ties,
RAL 9005 (black)

161

Panels

19 6 HU DISTRIBUTION MODULE PANEL

266 mm 6 HU

19 483 mm

16 LC-Duplex PFP

33 0

mm
Plug-in module

Part front plate (PFP)


Module panel - 45 horizontal,
with Z-blade back plane to accept
12 PreCONNECT Trunk cable dividers,
similar to page 151

Optional patchcord guide

APPLICATIONS
For installation in 19 racks
Particularly appropriate for large data center infrastructures

PROPERTIES
Highly flexible panel due to its modular front plates and
back plane
Suitable to accept all cables assembled by
Rosenberger OSI
For up to 288 channels (576 fibers)
Torsion and strain resistant cable support for 12
PreCONNECT Trunk cable dividers (Z-blades)
Cable routing slant backwards
Plug-in modules can be completely pulled out
Plug-in modules and part front plates can be mounted
tool-less
The module panel is a modular platform for different patch
field connectivity systems
Matrix front labeling:
slots for plug-in modules and part front plates printed on
module panel 1 to 16, each plug-in module and part front
plate channel is numbered 1 to n (example: matrix 6 - 8 =
module 6 - channel 8)
Standard light propagation of the plug-in modules:

162

uncrossed (straight) to maintain the channelwise cross


(pairwise flip) of our MTP trunk cables
MTP within the plug-in modules are male (since trunks
and patchcords are female)
Material and colour:
Body: aluminium powder coated, RAL 7032 (pebblegrey)
Front: steel powder coated, RAL 7035 (lightgrey) or
RAL 9005 (black)
Weight:
Module panel unassembled:
approx.: 3.5 kg
Plug-in module:
approx.: 0.5 kg

DELIVERY FORM
Module panel with separate plug-in modules or part front
plates factory assembled or separate for on site mounting
Mounting knobs in plug-in modules and part front plates

MTP is a registered trademark of US-Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

Panels

Partnumbers

SINGLE COMPONENTS
19 6 HU DISTRIBUTION MODULE PANEL - 45 HORIZONTAL
With Z-blade back plane to accept 12 PreCONNECT Trunk cable dividers and removable rear cover RAL 7032 (pebblegrey),
Front RAL 7035 (lightgrey)
Front RAL 9005 (black)

154A0000
154A2000

19 6 HU DISTRIBUTION MODULE PANEL - 30 VERTICAL


With foldaway rear cover and top and 30 downwards slant cable divider slots to
accept up to 24 PreCONNECT Trunks
RAL 9005 (black)

154A5000

6 HU BLIND PART FRONT PLATE, RAL 7035 (lightgrey)


RAL 9005 (black)

154A0001
154A2001

NUMBER
OF FIBERS

COUPLER TYPE

SM OS2

6 HU PART FRONT PLATES


RAL 7035 (lightgrey), assembled with couplers

OM3

OM4

SM OS2

OM3

OM4

12

MU- Duplex-Horizontal 1 5 4 A 0 2 4 0 1 5 4 A 0 2 4 5 OM3 1 5 4 A 0 2 4 5 OM4


LC-Duplex
1 5 4 A 0 1 5 0 1 5 4 A 0 1 5 5 OM3 1 5 4 A 0 1 5 5 OM4

24

MU- Duplex-Horizontal 1 5 4 A 0 2 5 5 1 5 4 A 0 2 6 0 OM3 1 5 4 A 0 2 6 0 OM4


LC-Duplex
1 5 4 A 0 1 6 5 1 5 4 A 0 1 7 0 OM3 1 5 4 A 0 1 7 0 OM4

32

LC-Duplex

1 5 4 A 0 4 7 0 1 5 4 A 0 4 7 2 OM3 1 5 4 A 0 4 7 2 OM4

36

MU- Duplex-Horizontal

1 5 4 A 0 2 0 0 1 5 4 A 0 2 0 5 OM3 1 5 4 A 0 2 0 5 OM4

6 HU PLUG-IN MODULE
RAL 9005 (black)
NUMBER
OF FIBERS

COUPLER TYPE

SM OS2

6 HU PART FRONT PLATES


RAL 9005 (black), assembled with couplers

OM3

OM4

SM OS2

OM3

OM4

12

MU- Duplex-Horizontal 1 5 4 A 2 2 4 0 1 5 4 A 2 2 4 5 OM3 1 5 4 A 2 2 4 5 OM4


LC-Duplex
1 5 4 A 2 1 5 0 1 5 4 A 2 1 5 5 OM3 1 5 4 A 2 1 5 5 OM4

24

MU- Duplex-Horizontal 1 5 4 A 2 2 5 5 1 5 4 A 2 2 6 0 OM3 1 5 4 A 2 2 6 0 OM4


LC-Duplex
1 5 4 A 2 1 6 5 1 5 4 A 2 1 7 0 OM3 1 5 4 A 2 1 7 0 OM4

32

LC-Duplex

1 5 4 A 2 4 7 0 1 5 4 A 2 4 7 2 OM3 1 5 4 A 2 4 7 2 OM4

36

MU- Duplex-Horizontal

1 5 4 A 2 2 0 0 1 5 4 A 2 2 0 5 OM3 1 5 4 A 2 2 0 5 OM4

3
Panels

6 HU PLUG-IN MODULE
RAL 7035 (lightgrey)

properties - 30 vertical
Easy and time saving installation of PreCONNECT cable
dividers in rear side square interfaces
Capacity up to 24 PreCONNECT Trunk cable dividers
Optimized cable routing within the rack due to 30 downwards
slant cable divider slots
Time saving installation and maintenance due to foldaway rear
cover and top
Connector legs are protected inside the panel
No waste of space because the cable dividers are inside the panel
MODULE PANEL - 30 vertical,
downwards slant trunk routing on
the rear side

ROSENBERGER OSI PRODUCT CATALOG

Well arranged cable routing inside the panel (256 single cables)
MODULE PANEL - 30 vertical is only available in black

163

panels

mini universal box

Type 2

Type 1
with PreCONNECT FIBER Trunk

Applications
Box for the connection of a few fibers where no infrastructure like racks, wall cabinets or cable ducts exists
Particularly appropriate for industrial and outdoor cabling
as well as cabling in humid and wet rooms

properties
Mini universal box available in two types:
1. distribution panel
To mount factory assembled ready for connection cables
on patchfield within the box. Particularly suited to
accept our factory assembled PreCONNECT Fiber cable
2. splice panel
To splice pigtails on cables, with patchfield inside
To splice cable to cable
Suitable for on-wall mounting and placing in cable
support systems
Max. possible fiber counts depend on type and
connectivity system, standard types see next page
1 x cable inlet:
Type 1 with 1 mounting bracket for PreCONNECT Trunk
and 1 x PG 13.5 cable gland for other assembled cables,
IP50 dust-proof
Type 2 with 1 x PG 13.5 cable gland
IP65 water-proof with round cable

164

2 x cable outlets:
Type 1 and 2 with 2 x PG 13.5 cable gland
for assembled cables, IP50 dust-proof
Type 2 with 2 x PG 13.5 cable gland IP65
water-proof with round cable
Box itself is IP67 water-proof
Dimensions (l x w x h): 200 x 120 x 75 mm
Material and colour:
plastic, RAL 7035 (lightgrey)

optional
For type 2:
Factory assembled pigtails ready for splicing (laid in) inside
panel and splice cassettes

delivery form
Type 1 and 2 with mounted couplers
All types including the glands listed in properties
for cable inlets and outlets
Type 2 including splice cassette, splice holder and splice
protectors, see page 174

accessories
Pigtails see pages 134/135

ROSENBERGER OSI PRODUCT CATALOG

Panels

partnumbers
fiber
count

SPLICE PANEL
for splicing of pigtails

distribution panel
type of coupler
SM

MM

SM

MM

SCSC-Duplex metal
LC LC-Duplex SM
OM3
OM4
E-2000E-2000 Simplex1 HRL

114A0420
114A0424

114A0428

114A0520

1 1 4 A 0 5 2 5 OM3
1 1 4 A 0 5 2 5 OM4

114A0620
114A0624

114A0628

114A0720

1 1 4 A 0 7 2 5 OM3
1 1 4 A 0 7 2 5 OM4

SCSC-Duplex metal
LC LC-Duplex SM
OM3
OM4
E-2000E-2000 Simplex1 HRL

114A0460
114A0464

114A0468

114A0560

1 1 4 A 0 5 6 5 OM3
1 1 4 A 0 5 6 5 OM4

114A0660
114A0664

114A0668

114A0760

1 1 4 A 0 7 6 5 OM3
1 1 4 A 0 7 6 5 OM4

12

LC LC-Duplex SM
OM3
OM4

114A0481

1 1 4 A 0 5 8 2 OM3
1 1 4 A 0 5 8 2 OM4

114A0681

1 1 4 A 0 7 8 2 OM3
1 1 4 A 0 7 8 2 OM4

3
Panels

Further coupler types and fiber counts on request. 1 = Typ R+M.

Partnumbers

splice panels for splicing of cable to cable


number of
fibers

12

16

24

114A0800

114A0801

114A0802

114A0803

114A0804

114A0805

114A0806

Further fiber counts on request.

ROSENBERGER OSI PRODUCT CATALOG

165

panels

universal box

applications
Freely configurable and highly modular Universal Box for
different installation environments, in which 19 panels are
not necessary or possible.

properties
For up to 24 channels (48 fibers)
Universal Box available as distribution box and splice box:
1. distribution box
Assembled cables can be fed into the box and fixed on
both front walls and attached at the inner coupler plate
2. splice box
Optionally, buffered-fiber pigtails, cable pigtails or
pigtail-bundle-cables are available pre-assembled for
splicing in the box
To splice the pigtails on the cable, the cable has to be fed
into the box and fixed on the front wall designated for that
To attach the pigtails, assembled cables are fed into the
box at the opposite side
Cables can be spliced directly to each other in the box too
Modular mounting parts for the front walls to feed and fix
all kinds of cables into the box are available, see page 167
Universal Box by default assembled with SMAP part front
plates with FO couplers

166

Material and colour:


Box: plastic RAL 7035 light grey, impact-resistant,
halogen-free
Front wall mounting parts: steel, powder coated
RAL7035 light grey
Dependent on the front wall mounting parts, the box can
be IP50 dust-proof up to IP66 water-proof
Dimensions (l x w x h): 360 x 254 x 111 mm

Optional
SMAP part front plates for copper modules (jacks) can be
mounted on a special tray on request
Coupler plates which can be mounted on the front walls
on request

delivery form
On request, depends on type and configuration
With blind covers on not used square interfaces

accessories




Cable glands and nuts see page 177


Blind-screws with nuts see page 177
Factory assembled splice cassettes see pages 136/137
Pigtails see pages 134/135
Raised floor-holder see page 167

ROSENBERGER OSI PRODUCT CATALOG

panels

Partnumbers
boxes
distribution panel

number of
channels/fibers

type of coupler

6 CH /12 F
12 CH/24 F
24 CH/48 F
36 CH/72 F
48 CH/96 F
6 CH/12 F
12 CH/24 F
24 CH/48 F
36 CH/72 F
48 CH/96 F
6 CH/12 F
12 CH/24 F
6 x 6 CH/ 6 x 12 F
(with 12 F MTP)

LC-Duplex
LC-Duplex
LC-Duplex
LC-Duplex
24 LC-Quad 48 LC-Duplex
MU-Duplex-Horizontal
MU-Duplex-Horizontal
MU-Duplex-Horizontal
MU-Duplex-Horizontal
MU-Duplex-Horizontal
SC-Duplex metal
SC-Duplex metal
MTP

splice panel

SM

OM3

SM

OM3

118A4001
118A4002
118A4003
118A4004
118A4009
118A4011
118A4012
118A4013
118A4014
118A4015
118A4021
118A4022
118A4025

1 1 8 A 4 0 0 5OM3
1 1 8 A 4 0 0 6OM3
1 1 8 A 4 0 0 7OM3
1 1 8 A 4 0 0 8OM3
1 1 8 A 4 0 1 0OM3
1 1 8 A 4 0 1 6OM3
1 1 8 A 4 0 1 7OM3
1 1 8 A 4 0 1 8OM3
1 1 8 A 4 0 1 9OM3
1 1 8 A 4 0 2 0OM3
1 1 8 A 4 0 2 3OM3
1 1 8 A 4 0 2 4OM3
1 1 8 A 4 0 2 6 OM3

118A4301
118A4302
118A4303

1 1 8 A 4 3 0 4OM3
1 1 8 A 4 3 0 5 OM3
1 1 8 A 4 3 0 6 OM3

118A4307
118A4308
118A4309

1 1 8 A 4 3 1 0 OM3
1 1 8 A 4 3 1 1 OM3
1 1 8 A 4 3 1 2 OM3

Empty box without coupler plate and no


splice cassette interface

118A4313
118A4314
on request

1 1 8 A 4 3 1 5 OM3
1 1 8 A 4 3 1 6 OM3
on request

118A4000

Further coupler types and numbers of fibers on request. 1 The maximum number of fibers in the splice panel is limited to 48 fibers, because higher numbers of fibers
can not be spliced due to shortage of space in the box. MTP is a registered trademark of US-Conec Ltd.

Partnumbers
modular mounting parts

IP50 without sealing


plate for 4 x PG

plate for 6 x PG

plate for 4 x
Cable-Divider

lip seal

4 x PG 21
118A4501

6 x PG 13,5
118A4502
6 x PG 16
118A4503
6 x PG 21
118A4504

118A4505

118A4506

panels

blind plate

118A4500

raised floor-holder
for mounting of our universal box in raised floors

IP66 with sealing

118A4507

4 x PG 21
1 1 8 A 4 5 08

ROSENBERGER OSI PRODUCT CATALOG

6 x PG 13,5
118A4509
6 x PG 16
118A4510
6 x PG 21
118A4511

099A0051

167

Panels

DISTRIBUTION BOX OUTDOOR

6 channel distribution box

12 channel distribution box

APPLICATIONS

DELIVERY FORM

Distribution box for structured cabling in outdoor


environment
Wall and mast mounting for distribution of single
channels of a multifiber system

Inclusive screwed cover


Assembled cable glands, LC couplers and fixing flanges

ACCESSORIES
Band clamps as fixing set

PROPERTIES
IP67 water-proof
All LC variants (single- and multimode)

partnumbers
number of
channels / fibers
3 CH / 6 F
6 CH / 12 F
12 CH / 24 F
18 CH / 36 F

168

SLFDU003-03
SLFDU003-06
SLFDU005-12
SLFDU008-18

ROSENBERGER OSI PRODUCT CATALOG

panels

EXCESS FIBER CABLE ENCLOSURE OUTDOOR

PROPERTIES
Mechanical protection for stored cable overlength
EXCESS FIBER CABLE ENCLOSURE available in four variants:
1. 1 HU EXCESS FIBER CABLE ENCLOSURE with drawer
function, suitable for approx. 30 m cable up to 7 mm
diameter
2. 1 HU EXCESS FIBER CABLE ENCLOSURE without drawer
function, suitable for approx. 30 m cable up to 7 mm
diameter
3. 2 HU EXCESS FIBER CABLE ENCLOSURE without drawer
function, suitable for approx. 50 m cable up to 7 mm
diameter
4. EXCESS FIBER CABLE ENCLOSURE (19 x 41 cm) for wall
and mast mounting, suitable for approx. 20 m cable up to
7 mm diameter

3
panels

APPLICATIONS
Enclosure for cable overlength storage in outdoor
environment
For wall mounting and in 19 racks

partnumbers
Variant
1 HU without drawer
1 HU with drawer

SLFCS001-000
SLFCS003-000

2 HU

SLFCS007-000

19 x 41 cm

SLFCS008-000

ROSENBERGER OSI PRODUCT CATALOG

169

panels

19 1 HU PANEL COPPER

APPLICATIONS
For installation in 19 racks
For distribution of PreCONNECT COPPER Trunks at
patchcords in data centers (not suitable for ToR Trunks)

Material and colour:


steel, RAL 7035 (lightgrey), RAL 9005 (black)

Optional
Other jack modules on request

PROPERTIES
Particularly suitable to accept 24 PreCONNECT COPPER
RJ45 jack modules CAT. 6A screened

ACCESSORIES
Panel accessories see pages 174 177

partnumbers
800A0200
800A0201

RAL 7035 (lightgrey)


RAL 9005 (black)

19 1 HU SMAP PANEL COPPER

APPLICATIONS
For installation in 19 racks
For distribution of PreCONNECT COPPER Trunks at
patchcords in data centers (not suitable for ToR Trunks)

Material and colour:


steel, RAL 9005 (black)

PROPERTIES

Other jack modules on request

Assembled with two SMAP 1/2 part front plates


Suitable to accept 24 PreCONNECT COPPER RJ45 jack modules CAT. 6A screened

Optional
ACCESSORIES
SMAP accessories see pages 160 /161
Panel accessories see pages 174177

partnumber
RAL 9005 (black)

170

161A5002

ROSENBERGER OSI PRODUCT CATALOG

panels

19 1 HU DISTRIBUTION PANEL COPPER ToR

APPLICATIONS

Optional

For installation in 19 racks


To interconnect PreCONNECT COPPER Trunks ToR with
patchcords in data centers

Panel cover on request

ACCESSORIES
Panel accessories see pages 174177

PROPERTIES
Particularly suitable to accept 24 PreCONNECT COPPER
ToR RJ45 jack modules CAT. 6A screened
Material and colour: steel, RAL 9005 (black)
Depth: 200 mm

RAL 9005 (black)

panels

partnumber
800A0204

SMAP DISTRIBUTION PANEL FIBER / COPPER VARIANT


The modular SMAP distribution panels and part front plates
(see pages 154/155) can be combined with the part front
plates of the SMAP Panels Copper (see page 170) to build
hybrid FO / copper panels.

ROSENBERGER OSI PRODUCT CATALOG

171

pANEL ACCESSORIES

172

ROSENBERGER OSI PRODUCT CATALOG

PANELS AND RACKS: PANEL ACCESSORIES

Rosenberger OSI attaches greatest importance


to meticulous manufacturing processes and the
use of high quality material even down to the
smallest components. To ensure the safety classes of panels, the quality of accessories is very
important, as already smallest material defects
and mistakes during the machining process can
affect the impermeability.

ROSENBERGER OSI PRODUCT CATALOG

Even the protecting and cable routing components e.g. the strain relief, the patchfield protection or cable managers have to pass intensive
quality controls. For we know: The whole system
will only work properly if the smallest detail will
be taken care of.

173

PANEL ACCESSORIES

PANEL ACCESSORIES

partnumbers
(1) Splice cassette

111A0008

(2) cover for Splice cassette

111A0015

(3) Splice holder for 12 crimp splice protectors

111A0000

(4) crimp splice protector

111A0001

(5) tension relief for 900 m-buffered-fiber

111A0009

Front plate blind covers


For cutout
ST
SC-Duplex
E-2000TM, SC-Simplex, MT-RJ

111A0013
111A0014
111A0016

strain relief
For cable gland
PG 13.5
PG 16
PG 21

111A0420
111A0421
111A0422

divisible conduit
With glands

inside

outside

PACO-14B
PACO-20B

12.9 mm
19.8 mm

18.7 mm
25.9 mm

099A0201
099A0202

divisible glands
TN/GTN 1314 (PG 13,5) Suitable for conduit PACO-14B
incl. adapter ring and nut for PG 21 hole

099A0215

TN/GTN 2120 (PG 21) Suitable for conduit PACO-20B


incl. PG 21 nut

099A0212

19 1 Hu Patchcord overlength panel


RAL 7035 (lightgrey)

174

4
3
5

111A0701

ROSENBERGER OSI PRODUCT CATALOG

PANEL ACCESSORIES

PANEL ACCESSORIES

Partnumbers
19 4 HU subfloor holder
RAL 9005 (black)
Robust fixture for very flexible, universal and easy
installation of 19 panels and active equipment in
raised floors

099A0052

19 patchfield protector
To prevent mechanical strain and damage
To prevent contamination
Highly recommended if 19 patchfields are mounted on subfloor
holders in raised floors.

19 1 HU Patchcord guide
RAL 7035 (lightgrey)

19 HORIZONTAL cable manager


RAL 9005 (black)
1 HU
2 HU

ROSENBERGER OSI PRODUCT CATALOG

099A0059
099A0060
099A0066
099A0083

PANEL ACCESSORIES

19 patchfield protector
1 HU
2 HU
3 HU
4 HU

111A0450

111A0454
111A0453

175

PANEL ACCESSORIES

PANEL ACCESSORIES

Partnumbers

labeling field

Suitable for all Rosenberger OSI panels and most of


the commercially available panels, containing:
1 labeling field
Mounting material
Assembly instruction
1 HU
2 HU
3 HU
4 HU

161A0002
162A0002
163A0002
164A0002

Partnumbers

1 hU Patchcord guide

For guidance and fixation of patchcords per height


unit 1 HU to both sides. The patchcord guide prevents
too small bending radii which could result in elevated attenuation.
Set consisting of: right and left 1 HU patchcord guides
with labeling fields, velcro stripes, M6 screws and cage
nuts. Fits into 600 mm wide cabinets.
For 1 HU panels
For 2 HU panels
For 3 HU panels
For 4 HU panels

176

161A0006
162A0006
163A0006
164A0006

ROSENBERGER OSI PRODUCT CATALOG

PANEL ACCESSORIES

PANEL ACCESSORIES

partnumbers

CABLE GLANDS WITH NUTS


For cable
PG 13.5 6 -12 mm plastic IP60

111A0426

PG 16

10-14 mm plastic IP60

111A0427

PG 21

13-18 mm plastic IP60

111A0402

PG 13.5 6-12 mm metal IP68

111A0428

PG 16

10-14 mm metal IP68

111A0429

PG 21

13-18 mm metal IP68

111A0410

partnumbers

CABLE GLANDS WITH PG 21 ADAPTERRINGS AND NUTS

PG 13.5 6-12 mm plastic IP60

111A0400

PG 16

111A0401

10 - 14 mm plastic IP60

PANEL ACCESSORIES

For cable

partnumbers

BLIND-SCREWS WITH NUTS


PG 13.5plastic IP60

111A0430

PG 16

plastic IP60

111A0431

PG 21

plastic IP60

111A0432

PG 13.5

metal IP68

111A0433

PG 16

metal IP68

111A0434

PG 21 metal IP68

111A0435

ROSENBERGER OSI PRODUCT CATALOG

177

Racks

178

ROSENBERGER OSI PRODUCT CATALOG

PANELS AND RACKS: Racks

Due to the increasing complexity of data


centers, the requirements regarding modern
rack rows are increasing as well. Besides a maximum protection of the cable routings, a clearly
arranged, easy to be installed and sophisticated
cable management plays a more and more
important role in infrastructure cabling.
Thus the same high quality levels apply for all
Rosenberger OSI products.

ROSENBERGER OSI PRODUCT CATALOG

Based on the 19 rack system NETcell from


apraNET and in cooperation with our customers,
we have combined the innovation of both companies to develop one modular and highly flexible infrastructure rack. Due to its barrier-free
cable managers offering large space and the
best practise inovative components, this distribution rack does not only provide the means
of proper cable management. Today, it already
meets the requirements a modern data center
will face in the future.

179

Racks

Patch Location Rack

Optional: cable overlength storage and cable guides


to be mounted on top of rack

Cable manager with several perforated cable feedthrough at both sides at the front and rear

Cable retainer, so called L-Fingers, ensure ideal


bending and kinking protection

Many useful details and options to mount trunks


and other cables perfectly at each place

Overlength storage and cable guide at base of rack,


optional

180

Cable conduits at the rack sides to connect the front


and rear cable manager

ROSENBERGER OSI PRODUCT CATALOG

Racks

APPLICATIONS

Optional

High density data center infrastructures


To build passive data center patch locations with
highest density

19 Intermediate-Rack to build rack rows with an uneven


number of racks on request

PROPERTIES

Factory mounted on a pallet (total-height with pallet and


packaging = 230 cm)
Incl. adjustable pedestals for on site mounting

DELIVERY FORM

ACCESSORIES
Wide range of accessories like e.g. side walls, cable guides,
overlength storage for top of rack etc. on request
For more technical details and partnumbers please ask for
our product information.

3
Racks

Innovative barrier-free cable management system


No rack pillars that interfere with cable routing due to
cable managers being integrated into the pillars
Covers of the cable managers are hinged in both directions and completely removable
Several perforated feedthroughs in the side and rear
walls of the cable managers for easy cable routing in the
vertical and horizontal way
Professional routing of large cable volumes from patchfields and storage of cable overlength inside the
vertical cable managers
Particularly suitable for FO cables due to cable retainers
(L-Fingers) and Finger-Slots
The rounded L-Fingers ensure high bending and
kinking protection for the cables even under tensile
load
L-Fingers do not have sharp edges and are very robust
and break resistant
Cables can neither be squeezed nor kinked for there is
enough space within the Finger-Slots
During work with open or removed covers the
L-Fingers hold the cables back in the Finger-Slots
Dimensions (h x d x w): 213 (46 HU) x 90 x 90 cm
Material and colour: steel, powder coated, RAL 9005 (black)

partnumber
RAL 9005 (black)

ROSENBERGER OSI PRODUCT CATALOG

142A3000

181

182

ROSENBERGER OSI PRODUCT CATALOG

ACCESSORIES

ROSENBERGER OSI PRODUCT CATALOG

183

ACCESSORies

INSPECTION AND CLEANING KIT

The kit includes all materials and tools for visual inspection
and cleaning of FO connectors and adapters. The main component is a video backpanel microscope. It is available with
a hand-held monitor or with a USB interface, alternatively.
The USB version needs a laptop or PC with USB 2.0 port. That
version comprises an additional feature compared to the

monitor version: the pictures can be saved for documentation.


Microscope adapters for 1.25 mm and 2.5 mm standard
ferrules are included, additonal adaptions to all frequently used
connector types are available as accessory. We are pleased to
provide you with a detailed data sheet.

Screen shot of a ferrule endface

A large variety of adapters enables to inspect all standard connectors with the video microscope. Connectors can also be inspected
through panel mounted couplers.

The software delivered with the USB microscope allows to


analyze the pictures in an automated way. Scratches and contaminations are marked in different colours and enable a reliable
examination of ferrule endfaces. This ensures an inspection in
conformity with IEC 61300-3-35.

Partnumbers
Video microscope with hand-held monitor

099 A 0388

USB microscope

099 A 0389

INSPECTION AND CLEANING KIT

184

ROSENBERGER OSI PRODUCT CATALOG

ACCESSORies

TEST LASER EV-3


Laser light source for defect location, fiber identification and
testing of connectors, singlemode and multimode
With 2.5 mm universal interface and adapter to 1.25 mm
Technical data sheet available on www.rosenberger-osi.com

Partnumber
TEST LASER EV-3

099A0332

REEL CLEANER
Cleaning device with a dry textile ribbon for all FO connectors with the exception of MT-RJ male (with pins)
One textile reel included
Up to 400 cleanings per reel
Dimensions (l x w x h): 127 x 83 x 48 mm
Weight: approx.: 150 g

Partnumbers
REEL CLEANER

099A0025

REPLACEMENT REEL

099A0026

CLICK CLEANER

ACCESSORIES

Handy cleaning tool for ferrule endfaces of FO


connectors.
Simple release of the cleaning mechanism by pushing the
tool holder
Unmating of the connector not necessary cleaning
through the adapter is available
Extendable nozzle for cleaning connectors, being difficult
accessible
Length: approx.: 185 mm
Weight: approx.: 25 g

Partnumbers
Click Cleaner, FOR FERRULES 1.25 mm

099A0390

Click Cleaner, FOR FERRULES 2.5 mm

099A0391

Click Cleaner, FOR RDC CONNECTORS

099A0395

MTP/MPO Cleaner

099A0055
MTP is a registered trademark of US Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

185

ACCESSORies

OTDR MEASUREMENT Fiber Case

Modcon type for up to three measurement fibers

Properties

CONFIGURATION WITH MODCON

Mode controller and up to 3 measurement fibers in a


handy box
Launching fibers with different connector interfaces
available
Singlemode quality connectors on multimode fiber types

All fiber types available


Max. length: 1,000 m per fiber type
Available with all simplex and duplex connector types
IP50 dust-proof
Take-up option for legs
Accessory box for consumables, e.g. measurement
adapters
Box with shoulder strap

ADVANTAGES:
Compact and clearly arranged measurement setup
Improved handling in mobile use
Measurement setup in conformity with IEC 61280-4-1
standard with encircled flux launch conditions
NOTES:
Worn-out connectors have to be factory refurbished at
Rosenberger OSI
The connector type has to be chosen at time of order

Partnumbers
Fiber TYPE

Fiber LENGTH [m]

CONNECTOR

remark

Sm

500

FC PC FC APC

pre-assembled

081 A 0081

Sm

1000

E-2000 HRL SC APC

spliced pigtail

081 A 4075

Sm

1000

SC SC

pre-assembled

081 A 0183

Sm

1000

FC APC E-2000 HRL

pre-assembled

081 A 0084

Sm

1000

E-2000 HRL E-2000 HRL

pre-assembled

081 A 0261

OM3

3 x 100

according to customer requirement

with mode controller

081 A 0087

OM4

3 x 100

according to customer requirement

with mode controller

081 A 0088

Type of launching fibers and connectors to be selected. Multiple fibers per box are available. The listed part numbers refer to the most standard types.
Contact us in case of individual requirements.

186

ROSENBERGER OSI PRODUCT CATALOG

ACCESSORies

Factory assembled version with one fiber

Spliced version with one fiber

FACTORY ASSEMBLED VERSION

SPLICED VERSION

Factory-assembled connectors according to your


requirements with connecting cables, length 2 m
Factory-provided measurements: Insertion Loss or OTDR
measurement as requested
Connector endfaces inspected by interferometer
Singlemode versions: measurement of fiber core excentricity

Measurement cable pigtails can be spliced on the fibers


according to the required setup
2 m of fiber are stored in the splice cassette
Measurement cable pigtails are not included and have to
be ordered separately; factory assembly is available on
request
Two crimp splice protectors and one splice holder are
included
Attenuation measured by OTDR, using a bare fiber adapter

ADVANTAGES:
Documented quality of connectors in view to measurement cable specification, like mentioned above
No splices within the launching fiber
NOTES:
Worn-out connectors have to be factory refurbished at
Rosenberger OSI
The connector type has to be chosen at time of order

ADVANTAGES:
Flexible solution (as described above)
Connector replacement possible on site
notes:
The launching fiber includes the splices of the two
measurement cable pigtails with good IL and RL
values, this is not a real problem

4
ACCESSORIES

Factory assembled version with 4 different fiber types

ASSEMBLY TOOLS
Rosenberger OSI provides all necessary tools for a professional assembly of FO connectors. Of course they are also available in small quantities.
Please contact us for further details regarding our assembly
tools. We would be pleased to assist you.

ROSENBERGER OSI PRODUCT CATALOG

187

ACCESSORies

MEASUREMENT CABLES

Properties

FORM OF DELIVERY

Reference cables with accurately specified connectors


enable measurements with a good repeatability
Measurement cables are equipped with connectors of
particular low tolerances
Connectors have a durable ceramic ferrule
Singlemode: the limit of the fiber core excentricity is
0.3 m, the apex-offset is specified with max. 30 m

With individual documentation


Patchcords up to a length of 6 m are shipped in a
durable bag with zip

To ensure the special tight tolerances, our measurement cables have to


pass extensive test procedures, here the core excentricity instrument

188

ROSENBERGER OSI PRODUCT CATALOG

ACCESSORies

The excentricity instrument is used to test, if the fiber core is


located exactly in the center of the ferrule. The specification
allows a max. deviation of 0.3 m. The measured sample
shows a an excentricity of less than 0.25 m.

The interferometer is used to measure the geometry of the


ferrule endface. The results are displayed by different imageguided methods. Only low tolerances are allowed here, too.

ACCESSORIES

4
Partnumbers
CONNECTOR

LC

Fiber TYPE

081 A 1430

MU

081 A 1413

SC

081 A 0143

E-2000TM HRL

081 A 1447

The chart shows the most standard types. We would be pleased to provide your individual configuration.

ROSENBERGER OSI PRODUCT CATALOG

189

HERE YOU WILL QUICKly FIND YOUR WAY.

WORTH KNOWING:

TECHNICAL TERMS, CONTENTS AND PERSONAL CONTACT.

TECHNICAL TERMS
Only a few like them, everybody needs them: technical
terminology is essential for precise communication. We have
prepared a little compendium about fiber optic technology
for you.

contact

area

PAGE 192

190

ROSENBERGER OSI PRODUCT CATALOG

SUBJECT INDEX
How to find all about SC connectors? Where to find duplex
patchcords? This index helps you to find specific products
and descriptions.
PAGE 196

PERSONAL CONTACT
Rosenberger OSI is not only located all over Germany by
subsidiaries but also represented in whole Europe by sales
agencies. The network of our parent company Rosenberger
also allows a global support.
PAGE 198

ROSENBERGER OSI PRODUCT CATALOG

191

TECHNICAL TERMS

A Absorption

Loss of radiation while passing a medium; a part of the


radiant energy is transferred e.g. into thermal energy.
APC
Angled polished contact, see HRL.
ATTENUATION
Ratio of power reduction in a transmission medium, e.g.
caused in an optical cable, link or component. Reasons
for optical attenuation are scattering and absorption in
connectors, splices and fibers. Often, the attenuation is
indicated in DECIBEL [dB].

B BACKSCATTERING TECHNIQUE

Technology which analyses the backscattered light of


pulses to characterize a fiber link.
BANDWIDTH
The difference between upper and lower cutoff frequency;
in an optical fiber, it is an indicator for the maximum possible data rate.

CLADDING
Outer layer of the glass material of an optical fiber. Its refractive index is lower than the index of the core material.
For fiber identification, the diameter of core and cladding
are imprinted, e.g. 50/125 m.
COATING
First protection layer on an optical fiber. It protects the
glass from humidity and mechanical influences.
CONNECTOR
Element to achieve a temporary interconnection of one or
more fibers. Either a male and a female connector are joined
or two connectors of the same or different type are mated
in an adapter.
CORE of a fiber
Usually, an optical fiber at least constists of a core surrounded by a cladding. Typically, the core material has
a higher refractive index as the cladding. Total reflexion
keeps the propagating light inside the core. For fiber
description, the diameter of core and cladding are imprinted, e.g. 50/125 m.

BANDWIDTH-DISTANCE-PRODUCT
Characteristic parameter of an optical fiber, usually expressed in MHz x km.

CORE GLASS
Material of the core of a fiber see core of a fiber.

BEND INSENSITIVE FIBER


Fiber types allowing small bending radii of a cable without
causing a significant increase in loss.

COUPLER
Also power divider: a passive optical device which divides
optical power into several fiber paths.

C CABLE CORE

All inner components of a cable, including fillers and strain


relief. It may include a wrapping layer.
CABLE JACKET
Outer layer of a cable for protection from environmental
influences.
CATV (Community Antenna Television)
TV reception of many users over one antenna.
CENTEr ELEMENT
Element in the center of a cable design, often used as a
strength member or filler.

CRIMPING
Method of attaching a cable strain relief to a connector.
Cable elements are fixed by deforming a metal sleeve to a
defined shape.

D DECIBEL [db]

Logarithmic notation of the ratio of a physical quantity


relative to a specified or reference level. It is often used to
indicate the attenuation of optical components:
a [dB]= -10 x log(powerout/powerin)
DIN (Deutsches Institut fr Normung)
German office for standardisation.
DISPERSION
In an optical conductor, the velocity of light depends on
its frequency, propagation mode or polarisation. These
effects cause a widening of signal pulses and limit transmission length and data rate.

192

ROSENBERGER OSI PRODUCT CATALOG

DOPING
By adding small amounts of special substances, the refractive
index of glass can be controlled.

ELECTROMAGNETIC WAVE
Propagating wave which consists of an electric and a
magnetic field component. Radio waves, X-rays and light
are electromagnetic waves. They only differ in the wavelength.
EMC (Electromagnetic Compability)
Branch of electrical engineering to study and control
electromagnetic interference.

F FERRULE

Part of an optical connector which is used to fix and to


align a fiber. Typical ferrules are made of zirconia ceramic
or precision mold plastic material.

FIBER
Transmission medium, consisting of a glass core and a
cladding. Signal light can propagate through the core
material over long distances. Fibers are protected by
several layers and built into cables.
FIBER OPTICS
Technology which uses optical fibers for data transmission.
In addition, the technology is also used for energy transmission, e.g. laser light for material machining.
Fiber CHANNEL (FC)
Network technology for storage networks with gigabit
capability. It comes with its own protocol and uses twisted
copper wires or optical fibers as transmission medium.
FITL (fiber in the loop)
Fiber in a municipal network. According to the endpoint of
the fiber, it is distinguished between:
FTTB - fiber to the building
FTTC - fiber to the curb
FTTH - fiber to the home
FTTP - fiber to the pedestal
FTTD (fiber to the desk)
Structured fiber cabling in a building (LAN) with fiberpath
to the workplace.

ROSENBERGER OSI PRODUCT CATALOG

G GBE (Gigabit Ethernet)

Computer networking technology with gigabit capability.


The term describes various technologies to transport
ethernet frames over a wired infrastructure. They are
defined by the IEEE 802.3 standards.
GRADED INDEX FIBER
Type of an optical fiber. The refraction index of the core
has a parabolic profile. This causes a continuous refraction
of the propagating light and limits the dispersion.
GRADED INDEX PROFILE
Gradient of the refraction index. In a typical graded index
fiber, the refraction index of the core decreases from the
center by a parabolic function - see graded index fiber.
GRP ELEMENT (glass reinforded plastic element)
Component of a fiber optical cable. It supports the fiber
and absorbs bend and tensile forces.

H HCS FIBER (hard cladded silica fiber)

Fiber type with a core of quartz glass and a cladding made


of plastic material. It is also called PCF (polymer cladded
fiber).
HRL (high return loss)
Term which characterizes low reflective interconnections,
also used for connectors with APC ferrule technology.
Using angled polished fiber endfaces, reflected light is not
propagated in the fiber core. Distortion by reflected light
is highly reduced.
HYBRID ADAPTER
Component for connecting different connector interfaces.

I IEC (International Electrotechnical Commission)

Non-profit international organisation with headquarter in


Geneva, Switzerland. IEC committees work on international
electrical standards.
IEEE (Institute of Electrical and Electronic Engineers)
A non-profit professional association, organizing expert
conferences and publishing professional journals. The IEEE
also forms committees for standardisation. Well known are
the IEEE 802 Ethernet standards.
INFINIBAND
Communication technology which uses copper or fiber
optic cabling technology. It allows to bundle several communication channels to one link. Typical is an application
using four channels in parallel (8 fibers).

193

TECHNICAL TERMS
INDOOR CABLE
Cable designed for installation inside buildings.
INSERTION LOSS
See ATTENUATION
INTERFEROMETER
Precision instrument which uses a technology of superimposing waves. In the fiber optic technology, it is used to
characterize the geometry of ferrules or fiber endfaces.
ISDN (Integrated Services Digital Network)
Communication standard for simultaneous digital
transmission of several services like voice, video, data etc.

LAN (Local Area Network)


Data network covering local areas like buildings or offices.
LIGHT
Visible electromagnetic waves with a wavelength between
380 nm (violet) and 780 nm (red) or adjacent ranges like
ultravioett (UV) or infrared (IR) light. For data transmission,
typically IR light with a wavelength between 850 nm and
1550 nm is used.
LOOSE BUFFER FIBER
Tubing which contains a loose bundle of fibers in a stressless way. It can be with or without a gel filling.
LOOSE TUBE
Optical fiber protected by a loose tubing.

M MAN (Metropolitan Area Network)

Computer network covering city or large campus areas.


MICROBENDING
Small geometrical imperfections at the boundary between
core and cladding of an optical fiber. Microbending creates
higher order modes which have a higher attenuation.

MODE
Particular electromagnetic field pattern of a wave propagating in a medium. Different modes in an optical fiber
propagate with different speed.
MTP connector
Fiber optic connector according to the MPO standard. It
supports 12, 24, 48 or 72 fibers. MTP is a registered trademark of US Conec Ltd.

194

MULTI JUMPER
PreCONNECT FIBER or COPPER Trunk cables for multichannel point-to-point interconnections for indoor applications.
MULTIMODE FIBER
Fiber type which allows the propagation of several light
modes.

o OUTDOOR CABLE

Cable material which is suitable for outdoor installation,


e.g. in ducts or cable trays.
OPTICAL FIBER
Dielectric transparent fiber, produced of glass or plastic
material. Light coupled into the fiber is propagated and
thus enables the transmission of data or energy (laser light).
OPTICAL WAVEGUIDE
See optical fiber.

OPTICAL WINDOW
Typical optical fibers have a minimum in attenuation at
wavelengths of 850, 1300, 1550 and 1625 nm. These frequency ranges allow transmission over longer distances
and are called optical windows.
OTDR (Optical Time Division Reflectometer)
Instrument which utilises the reflection pattern of optical
pulses to measure the characteristics of a fiber link.

p PARALLEL OPTIC LINK

Technology used for high data rates over short distances.


Data (bytes, nibbles) is split into bits and transmitted simultaneously over individual fibers.
PATCHCORD
Short cable to manage interconnections on a distribution
panel.

PHYSICAL CONTACT (PC)


Spherical polish for ferrules to ensure fiber contact
without gap.
PIGTAIL
Cable or fiber assembly with a connector at only one end.
PON (Passive Optical Network)
Passive optical network for FITL including only fiber links
and passive components like splitters, couplers or connectors.

ROSENBERGER OSI PRODUCT CATALOG

STEP INDEX FIBER


Multimode fiber with a homogeneous refractive index of
the core. These types are typically used for short distances
or for transmission of laser energy.

PreCONNECT
Brand of the customized fiber optical cabling system by
Rosenberger OSI.

R REFLECTION

Change in direction of a wavefront. Light is reflected when


it passes the interface of 2 media with different refraction
index. In fiber optic technology, usually reflexions in interconnections should be avoided, because they can cause
signal noise.
REFRACTION
Change in direction of an optical beam/wave due to a
change of the optical density in a medium.
REFRACTIVE INDEX
Characteristic of an optical medium which describes its
optical density. The speed of light in a medium is calculated
by dividing the speed of light in vacuum by the refractive
index.
RETURN LOSS
Loss of signal power resulting from reflections. The RL is
defined as the ratio between launched power to reflected
power and usually noted in DECIBEL. Transmission systems
are designed to have a high return loss.

RIBBON CABLE
Multi-fiber cable with multiple fibers running parallel.
These cables have typically a flat design.

S SAN (Storage Area Network)


Network in a data center.

SEMI TIGHT TUBE FIBER


Fiber embedded in a thin tubing.

STRENGTH MEMBER
Element in a cable material which absorbs bending moment and/or tensile force.

TIGHT TUBE FIBER


Fiber with a coating, tight embedded in a plastic material.
TIME DIVISION MULTIPLEX
Method to combine multiple signals into one serial data
stream.

u UNIT OF HEIGHT

19-Inch rack systems normally use panels with a height of


44.45 mm [1.75] or a multiple of that unit.

W WAN (Wide Area Network)

Data transmission network covering large distances.

WAVELENGTH
Spatial period of a wave. Visible light has a wavelength
between 380 and 780 nm in vacuum. In the fiber optic
technology, light with a wavelength of the optical windows is used for data transmission.
WAVELENGTH DIVISION MULTIPLEX (WDM)
Several data streams are transported over one fiber by
assigning different signal wavelengths. Dependent on the
number of signals launched into one fiber, the method is
called Coarse Wavelength Division Multiplex (CWDM) or
Dense Wavelength Division Multiplex (DWDM).

SINGLEMODE FIBER
Fiber type which allows the propagation of one mode
only. Usual dimension is 9/125 m. Singlemode fibers
cause less dispersion than multimode types and therefore
can be used for higher data rates and longer distances.
SPLICE
Permanent connection of a fiber, made by fusing or by the
use of an adhesive.
SPLITTER (also power splitter)
Passive component to divide optical power from one fiber
to several fibers see coupler.

ROSENBERGER OSI PRODUCT CATALOG

195

subject index

Accessories

Panel, p. 174-177

PreCONNECT FIBER, p. 118 f.
SMAP Panel, p. 160 f.

Adapter, p. 62, 64, 66, 68-73, 74 f.

APC (Technology), p. 53

Application fields, p. 14-31

Assembly tools, p. 187

Beam expansion, p. 52
Blind part front plate, p. 151, 153, 155, 163, 167
Blind screws, p. 177
Breakout cable, p. 102 f., 112-115
Broadcast, p. 24-27

Cable divider, p. 41, 49


Cable glands, p. 177
Cable manager, p. 175, 180 f.
Cable type

A-DQ(ZN)B2Y, p. 97

I-B(ZN)BH, p. 95, 99

U-DQ(ZN)BH, p. 96, 100 f.
Cleaner, p. 185
Comparison matrix, p. 101
Conduit, p. 174
Connectors, p. 61-80
Contact, p. 198 f.
Coupler bracket, p. 118

Data center, p. 16-19


DCX-cabling, p. 51
DIN (LSA), p. 73
DIN Contact, p. 77
Direct Attach Long Link Cable, p. 107
Direct Attach Short Link Cable, p. 107
Distribution module panel

3 HU, p. 150 f.

6 HU, p. 162 f.
Distribution panel

1 HU and 2 HU, p. 142-145
COPPER ToR, p. 171
FIBER/COPPER variant, p. 171
Outdoor, p. 168 f.
SMAP, p. 154 f.,
SMAP with MTP modules, p. 158 f.

E-2000, p. 68
Efficiency cable, p. 95, 99
Engineering, p. 38 f.
ESCON, p. 89

Excess fiber cable enclosure outdoor, p. 169


Excess fiber cable enclosure, p. 169
Expanded beam contact #5, p. 78
Expanded beam contact #12, p. 79
Expanded beam contact, p. 52, 78 f.

Factory assembled splice cassettes, p. 136 f.


FC, p. 71
FDDI, p. 89
Fiber accessories, p. 118
Fiber trunk, p. 94-101, 108 f., 110 f.
FO-trunk, p. 94-101, 108 f., 110 f.
F-SMA, p. 89
FTTA, p. 20-23, 110-117, 168 f.

Harnesses, p. 104 f., 107


Heavy Duty 1000, p. 85
Heavy Duty 600, p. 84
Heavy Duty SC-RJ, p. 89
Heavy Duty, p. 27, 29 ff., 53, 84 f., 108
Hybrid interfaces, p. 84 f.

Indoor cable, p. 95, 99


Industrial, p. 28-31
InfiniBand, p. 106 f.
Inspection and cleaning kit, p. 184
Installation Tube Indoor, p. 94, 98, 102, 106
Installation Tube Outdoor, p. 94, 108 f., 110, 112, 114
Installation, p. 41

J Jack modules, p. 122-125


Labeling
fields, p. 144 f., 148 f., 160, 176
L

Laser Connect 100, p. 86 f.


Laser Connect High Power, p. 54 f., 88
Launching box, p. 186 f.
LC, p. 62 f.
Logistics, p. 39
LSA (DIN), p. 73
LSH (E-2000), p. 68

Made by Rosenberger, p. 89
Maintenance, p. 42
Measurement fiber box, p. 186 f.
Migration Harness, p. 107
Mini breakout cable, p. 103
Mini contact, p. 76
Mini universal box, p. 164 f.
Mining, p. 28-31
Mobile communication, p. 20-23, 110-117, 168 f.
MTP is a registered trademark of US-Conec Ltd.
E-2000 is a registered trademark of Diamond S.A.

196

ROSENBERGER OSI PRODUCT CATALOG

Mobile trunk, p. 26, 31, 108 f.


MTP Divider Cables, p. 104 f.
MTP modules, p. 159
MTP/MPO, p. 69
MT-RJ, p. 70
MU, p. 64 f.

Optical contact #16, p. 80 f.


Optical contacts, p. 76-81
OTDR-measurement fiber box, p. 186 f.
Outdoor cable, p. 97, 100-117

Panel accessories, p. 173-177


Panel back plane, p. 151, 160 f., 163
Panel COPPER SMAP, p. 170
Panel COPPER, p. 170
Panels, p. 141-171
Parallel Optics, p. 106 f.
Part front plates, p. 151, 153, 155, 163
Patchcord guide, p. 175
Patchcord overlength panel, p. 174
Patchcords COPPER, p. 122 f., 125, 133
Patchcords FIBER, p. 128-132
Patchfield protector, p. 175
Pigtails, p. 134
Planning, p. 36
Plug-in modules, p. 153, 159, 163
PreCONNECT Cable Dividers, p. 41, 49
PreCONNECT (technology), p. 48 ff.
PreCONNECT COPPER Trunk Multi Jumper, p. 123
PreCONNECT COPPER Trunk ToR, p. 124 f.
PreCONNECT COPPER Trunk, p. 122
PreCONNECT COPPER, p. 121-125
PreCONNECT FIBER accessories, p. 118 f.
PreCONNECT FIBER Breakout Outdoor, p. 112 f., 114 f.
PreCONNECT FIBER Breakout, p. 102 f.
PreCONNECT FIBER Cablebundle Outdoor, p. 116
PreCONNECT FIBER Distribution Station Outdoor, p. 117
PreCONNECT FIBER MTP-Divider Cables, p. 104 f.
PreCONNECT FIBER Trunk Mobile, p. 26, 31, 108 f.
PreCONNECT FIBER Trunk Multi Jumper, p. 98-101
PreCONNECT FIBER Trunk Outdoor, p. 110 f.
PreCONNECT FIBER Trunk, p. 94-97
PreCONNECT FIBER, p. 93-119
Products in detail overview, p. 58 f.
Products, p. 62-189
Project management, p. 41

Quality signet, p. 89

Rack, p. 180 f.
Raisedfloor-holder, p. 167, 175
RDC (Rosenberger Duplex Connector), p. 82
Reel cleaner, p. 185
RJ45 connector, p. 125
RJ45 jack modules, p. 122 f., 125
Router-cabling, p. 51
RQC (Rosenberger Quad Connector), p. 83

SC, p. 66 f.
Screwing, p. 177
Services, p. 32-43
SMAP accessories, p. 160 f.
Spherical lens, p. 55
Splice cassettes, p. 136 f.
Splice module panel, p. 152 f.
Splice panel

1 HU and 2 HU, p. 146-149
SMAP, p. 156 f.
ST, p. 72
Strain relief, p. 174
Support, p. 42
Switch-cabling, p. 51

Technical terms, p. 192-195


Technology, p. 44-55
Telecommunication, p. 20-23
Test laser, p. 185
Tools, p. 187
Trunk cable divider holder, p. 118
Trunk, p. 18 f., 23, 26, 31, 48 f., 94-101, 108 f., 110 f.,
122-125


Universal box, p. 166 f.

Universal cable, p. 96, 100 f.

Universal-coupler bracket, p. 118

MTP is a registered trademark of US-Conec Ltd.

ROSENBERGER OSI PRODUCT CATALOG

197

personal contact

sales offices and Representatives national and international


headquarters
Germany
Rosenberger-OSI GmbH & Co. OHG
Endorferstr. 6 D-86167 Augsburg

Rosenberger Hochfrequenztechnik GmbH & Co. KG


Hauptstrae 1D-83413 Fridolfing

Phone: +49(0)821-24924-0
Fax:
+49(0)821-24924-29

Phone: +49(0)8684-18-0
Fax:
+49(0)8684-18-499

info@rosenberger-osi.de
www.rosenberger-osi.de

info@rosenberger.de
www.rosenberger.com

german sales offices


West

North-east

Am Ravelin 14D-48653 Coesfeld

Strae 69 Nr. 16 AD-13125 Berlin Karow

Phone: +49(0)25 41-8463-60


Fax:
+49(0)25 41-8463-61

Phone: +49(0)30-94518455
Fax:
+49(0)30-94518456

dieter.stapelbroek@rosenberger-osi.de

jens.woryna@rosenberger-osi.de

central

South-west

South

Stormstr. 22 D-63110 Rodgau/Nieder-Roden

Pfaffenweg 15D-70180 Stuttgart

Endorferstr. 6 D-86167 Augsburg

Phone: +49(0)6106-8269-44
Fax:
+49(0)6106-8269-46

Phone: +49(0)711-620072-78
Fax:
+49(0)711-620072-79

Phone: +49(0)821-24924-57
Fax:
+49(0)821-24924-29

harald.becker@rosenberger-osi.de

stephan.elfe@rosenberger-osi.de

robert.prommer@rosenberger-osi.de

Representatives
france

switzerland

CDBL Consultant
Mr. Claude Deubel
3 Rue du lys dORF-94370 Sucy en Brie

LEO Solutions AG
Mr. Leo Vetsch
Rti-Tobel 1072CH-9053 Teufen

Phone: +33(0)1725010-81

Phone: +4171-3332380

cdbl-consultant@neuf.fr

support@leosolutions.ch

USA

netherlands / BELGIum

italy

M.A.C. Consulting

Mr. Ab Vingerling
Noordhavenpoort 40
NL-2152 HB Nieuw Vennep

Mr. Sergio Terraneo


Via Leopardi 3I-22060 Cabiate

Mrs. Martina Carlson


19271 Lookout Lane
Huntington Beach, CA 92646
Phone: +17146258321

Phone: +31252625311
osi-fiber@polymorfo.com

Phone: +3931768245
sergio.terraneo@alice.it

martina.carlson@rosenberger-osi.com

198

ROSENBERGER OSI PRODUCT CATALOG

International
Austria

Brazil

China

Walter Krenn
Hochfrequenztechnik GmbH
Simmeringer Hauptstrae 421
A-1110 Wien

Rosenberger Domex Telecom


Cabletech Avenue, 601Guaramirim
CEP 12295-230 Cacapava-Sao Paulo

Rosenberger Asia Pacific


Electronic Co. Ltd.
No. 3, Anxiang Road, Block B
Tianzhu Airport Industrial Zone
Beijing 101300PR China

Phone: +43-1-7487117-0
Fax:
+43-1-7487117-90
info@krenn.at
www.krenn.at

Phone: +55-12-32218500
Fax:
+55-12-32218543

Phone: +86-10-8048 1995


Fax:
+86-10-8048 2438

vendas@rosenbergerdomex.com.br
www.rosenbergerdomex.com.br

info@rosenberger.com.cn
www.rosenberger.com.cn

Denmark

India

Italy

Rosenberger Danmark A/S


Blokken 38 Box 92
DK-3460 Birkerod

Rosenberger Electronic Co.


(India) Pvt Limited
Plot No. 263, Sector 6
IMT Manesar, GurgaonHaryana-122050

Rosenberger Hochfrequenztechnik
GmbH & Co. KG
Sales Office Milano
Via Brodolini, 31I-20049 Concorezzo-MB

Phone: +91-124-4775500
Fax:
+91-124-4775501

Phone: +39-039-9630306
Fax:
+39-039-5968439

info@rosenberger.in

riccardo.santovito@rosenberger.de

Spain

Sweden

United Kingdom

Rosenberger Telecom, S.A.


Ed Olimpia N18P.I. Ventorro del Cano
Calle Lozoya, 2.E-28925 Alcorcn /Madrid

Rosenberger Sverige AB
Vallgatan 5BS-17067 Solna

Rosenberger Micro-Coax Ltd.


2b Mercury HouseCalleva Park
AldermastonGB-Berkshire RG7 8PN

Phone: +4545821294
Fax:
+4545821395
mail@rosenberger.dk
www.rosenberger.dk

Phone: +34-91-3528352
Fax:
+34-91-3529813
rosenberger@epirsa.com
www.rosenberger.es

Phone: +46-8-6362600
Fax:
+46-8-6362626
info@rosenberger.se
www.rosenberger.se

Phone: +44-1-18-9810023
Fax:
+44-1-18-9816180
sales@rmcoax.com
www.rmcoax.com

USA
Rosenberger Site Solution, LLC.
102 Dupont Drive
USA-Lake Charles, LA 70607
Phone: +1-337-5985250
Fax:
+1-337-5985290
rlss@rlss.us
www.rlss.us
All information contained herein is to be reliable as of
the date of publication, but is subject to change without notice.

ROSENBERGER OSI PRODUCT CATALOG

199

Imprint
Text, design:
penguin, Lbeck
Print:
de Vega medien GmbH, Augsburg
Image sources:
Technical product photography:
Angelika Waschke, Daiting
Image and application photography:
Andr Walther, Peine
penguin, various image agencies
Images on pages 28/29 and 30/31 (center):
courtesy of RAG Deutsche Steinkohle

Every care has been taken to compile all technical information.


However, as errors cannot be excluded, please note that we
cannot guarantee or accept liability for any consequences
due to incorrect information.
501-01-09-12

We reserve the right to make technical changes at any time.


Rosenberger OSI GmbH & Co. OHG

200

EXCELLENT PRODUCTS, COMPREHENSIVE SERVICES


AND WELL-FOUNDED KNOW-HOW.
DISCOVER 200 PAGES OF CABLING COMPETENCE.