This document provides biocide treatment plans for various water and oil streams at a facility. It lists location, pump, biocide type, injection rate in liters/hour, duration in hours and total biocide needed per batch. Rates vary from 500-2000 ppm depending on location and past bacteria detection. The order of treatments is specified. Remarks provide additional context like reasons for biocide levels and locations.
This document provides biocide treatment plans for various water and oil streams at a facility. It lists location, pump, biocide type, injection rate in liters/hour, duration in hours and total biocide needed per batch. Rates vary from 500-2000 ppm depending on location and past bacteria detection. The order of treatments is specified. Remarks provide additional context like reasons for biocide levels and locations.
This document provides biocide treatment plans for various water and oil streams at a facility. It lists location, pump, biocide type, injection rate in liters/hour, duration in hours and total biocide needed per batch. Rates vary from 500-2000 ppm depending on location and past bacteria detection. The order of treatments is specified. Remarks provide additional context like reasons for biocide levels and locations.
This document provides biocide treatment plans for various water and oil streams at a facility. It lists location, pump, biocide type, injection rate in liters/hour, duration in hours and total biocide needed per batch. Rates vary from 500-2000 ppm depending on location and past bacteria detection. The order of treatments is specified. Remarks provide additional context like reasons for biocide levels and locations.
GX821-2A 100% stroke = 1.1 l/h GX821-2B 100% stroke = 1.1 l/h GX822B 100% stroke = 65 l/h TA821 Bactirem 455 TA822 Bactirep 4018 GX821 GX822 GX821-2A GX821-2B GX822B WATER INJECTION WATER INJECTION DA-350 GX722 Suction GX722 DS300 Water Outlet DS301 Water Outlet DS302 Water Outlet DS300 Oil Inlet DS301 Oil Inlet GX721 Suction Scale Inhibitor Lines Foam Inhibitor Lines 22,443 sbopd 149 m3/h 324 sbwpd 2.1 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 0.89 500 0.44 5 2.2 U/S DS301 GX 822B 2.15 2,000 4.30 5 21.5 GX722 discharge to DS-320 GX 822B 5.20 500 2.60 5 13.0 Oily water 8'' header GX 822B 10 500 5.0 1 5.0 DA350 GX 821-2A 14.5 1,000 0.60 24 14.5 LOCATION PUMP BIOCIDE Considering the line length, better to inject slowly but during long time. 1,000 ppm because of bacteria detected To be started first 2,000 ppm due to low water production rate To be done after injection in DS301 1 hour is enough to replace 3 times the 8" line volume, to be done after discharge to DS320 WATER OIL REMARK 30,574 sbopd 203 m3/h 361 sbwpd 2.4 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 0.89 500 0.44 5 2.2 2 U/S DS301 GX 822B 2.39 2,000 4.78 5 23.9 3 GX722 discharge to DS-320 GX 822B 7.09 500 3.54 5 17.7 1 Oily water 8'' header GX 822B 10 500 5.0 1 5.0 4 DA350 GX 821-2A 14.5 500 0.60 12 7.3 5 OIL LOCATION PUMP BIOCIDE ORDER WATER Considering the line length, better to inject slowly but during long time. 2,000 ppm due to low water production rate 1 hour is enough to replace 3 times the 8" line volume, to be done after discharge to DS320 REMARK 30,849 sbopd 204 m3/h 1,000 sbwpd 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 0.89 500 0.44 5 2.2 2 U/S DS301 GX 822B 6.63 1,000 6.63 5 33.1 3 GX722 discharge to DS-320 GX 822B 7.15 500 3.58 5 17.9 1 Oily water 8'' header GX 822B 10 500 5.0 1 5.0 4 DA350 GX 822B 14.5 1,000 2.90 5 14.5 5 LOCATION PUMP BIOCIDE ORDER 1,000 ppm due to bad DS-401 outlet 1,000 ppm due to low water production rate 1 hour is enough to replace 3 times the 8" line volume WATER OIL REMARK 30,849 sbopd 204 m3/h 1,000 sbwpd 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 0.89 1,000 0.89 5 4.4 2 U/S DS301 GX 822B 6.63 1,500 9.94 5 49.7 3 GX722 discharge to DS-320 GX 822B 7.15 750 5.36 5 26.8 1 Oily water 8'' header GX 822B 10 750 7.5 1 7.5 4 DA350 GX 822B 14.5 1,500 4.35 5 21.8 5 WATER OIL Increase injection rate to be sure to kill all bacteria in case of TRB detection problem in Lab REMARK LOCATION PUMP BIOCIDE ORDER 30,849 sbopd 204 m3/h 1,000 sbwpd 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 0.89 1,000 0.89 5 4.4 2 U/S DS301 GX 822B 6.63 1,500 9.94 5 49.7 3 GX722 discharge to DS-320 GX 822B 7.15 750 5.36 5 26.8 1 Oily water 8'' header GX 822B 10 750 7.5 1 7.5 4 DA350 GX 822B 14.5 1,500 4.35 5 21.8 5 DS301 oil outlet (PSV 3130 A/B treatment) GX 822B 2.00 2 4.0 7 TA 360 GX 822B 50 1 50 6 LOCATION PUMP BIOCIDE ORDER WATER OIL Increase injection rate to be sure to kill all bacteria REMARK 30,849 sbopd 204 m3/h 1,000 sbwpd 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 0.89 500 0.44 5 2.2 2 U/S DS301 GX 822B 6.63 1,000 6.63 5 33.1 3 GX722 discharge to DS-320 and oily water header GX 822B 17.50 500 8.75 5 43.8 1 DA350 GX 822B 14.5 1,000 2.90 5 14.5 4 DS301 oil outlet (PSV 3130 A/B treatment) GX 822B 2.00 2 4.0 5 TA 360 GX 822B 50 1 50 6 dead legs careful to not inject more than 4 l in order to protect PSV from local high concentration biocide which can damage PSV gasket WATER 1,000 ppm due to low water production rate Open 2 hours the by pass to oily water header 1000 ppm because we often detect bacteria in DA 350 LOCATION PUMP BIOCIDE ORDER OIL REMARK 30,849 sbopd 204 m3/h 1,000 sbwpd 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 0.89 500 0.44 5 2.2 2 U/S DS301 GX 822B 6.63 1,000 6.63 5 33.1 3 GX722 discharge to DS-320 (wash water) GX 822B 7.15 500 3.58 5 17.9 1 DA350 GX 822B 14.5 1,000 2.90 5 14.5 4 DS301 oil outlet (PSV 3130 A/B treatment) GX 822B 2.00 2 4.0 5 TA 360 GX 822B 50 1 50 6 OIL REMARK LOCATION PUMP BIOCIDE ORDER dead legs careful to not inject more than 4 l in order to protect PSV from local high concentration biocide which can damage PSV gasket WATER 1,000 ppm due to low water production rate 1000 ppm because we often detect bacteria in DA 350 30,849 sbopd 204 m3/h 1,000 sbwpd 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 0.89 500 0.44 5 2.2 2 U/S DS301 GX 822B 6.63 1,000 6.63 5 33.1 3 GX722 discharge to DS-320 (wash water) GX 822B 25.00 500 12.50 5 62.5 1 DA350 GX 822B 14.5 1,000 2.90 5 14.5 4 TA 360 GX 822B 50 1 50 5 WATER 1,000 ppm due to low water production rate 1000 ppm because we often detect bacteria in DA 350 LOCATION PUMP BIOCIDE ORDER OIL REMARK 21,404 sbopd 142 m3/h 633 sbwpd 4.2 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 821-2A 1.96 500 0.98 5 4.9 2 U/S DS301 GX 822B 4.19 1,000 4.19 5 21.0 3 GX722 discharge to DS-320 (wash water) GX 822B 25.00 500 12.50 5 62.5 1 DA350 GX 822B 14.5 1,000 2.90 5 14.5 4 TA 360 GX 822B 50 1 50 5 TRAITEMENT 455 OIL REMARK LOCATION PUMP BIOCIDE ORDER WATER 1,000 ppm due to low water production rate 1000 ppm because we often detect bacteria in DA 350 32,085 sbopd 164 m3/h OIL 7294 SBOPD 1,000 sbwpd WATER 4 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 2.61 500 1.31 5 6.5 2 U/S DS301 GX 822B 6.63 1,000 6.63 5 33.1 3 GX722 discharge to DS-320 (wash water) GX 822B 25 500 12.50 5 62.5 1 Flushing of Oily water 8'' header GX 822B 20 500 10.0 1 10.0 4 DA350 GX 822B 14.5 1,000 2.90 5 14.5 5 TA 360 50 6 TRAITEMENT 4018 To use a bucket to tranfer the biocide directly in the open drain WATER 1,000 ppm due to low water production rate To inject at the outlet of GX722 1000 ppm because we often detect bacteria in DA 350 To inject at the outlet of GX722 LOCATION PUMP BIOCIDE ORDER OIL REMARK From D1 + D2 43,902 sbopd 158 m3/h OIL 20000 SBOPD 1,500 sbwpd WATER 500 SBWPD 9.9 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 500 0.50 5 2.5 2 U/S DS301 GX 822B 9.94 1,000 9.9 5 49.7 3 GX722 discharge to DS-320 (wash water) GX 822B 15 500 7.50 5 37.5 1 Flushing of Oily water 8'' header GX 822B 20 500 10.0 1 10.0 4 DA350 GX 822B 14.5 1,000 2.90 5 14.5 5 TA 360 GX 822B 50 1 50 6 TRAITEMENT 455 OIL REMARK From D1 + D2 LOCATION PUMP BIOCIDE ORDER WATER 1,000 ppm due to low water production rate To inject at the outlet of GX722 1000 ppm because we often detect bacteria in DA 350 To inject at the outlet of GX722 78,138 sbopd 521 m3/h OIL 48000 SBOPD 3,300 sbwpd WATER 2300 SBWPD 21.9 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.00 5 5.0 2 U/S DS301 GX 822B 21.86 1,000 21.9 5 109.3 3 GX722 discharge to DS-320 (wash water) GX 822B 15 500 7.50 5 37.5 1 Flushing of Oily water 8'' header GX 822B 20 500 10.0 1 10.0 4 DA350 GX 822B 14.5 500 1.45 5 7.3 5 TA 360 GX 822B 50 1 50 6 TRAITEMENT 4018 WATER To inject at the outlet of GX722 To inject at the outlet of GX722 LOCATION PUMP BIOCIDE ORDER OIL REMARK From D1 + D2 30,138 sbopd 201 m3/h 1,000 sbwpd 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.00 5 5.0 2 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 3 GX722 discharge to DS-320 (wash water) GX 822B 20 500 10.00 5 50.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TA 360 GX 822B 50 1 50 5 TRAITEMENT 455 OIL REMARK LOCATION PUMP BIOCIDE ORDER WATER Open 2 hours the by pass to oily water header for Flushing of Oily water 8'' header 23,664 sbopd 158 m3/h 1,000 sbwpd 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.00 5 5.0 2 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 3 GX722 discharge to DS-320 (wash water) GX 822B 20 500 10.00 5 50.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TA 360 GX 822B 50 1 50 5 TRAITEMENT 4018 WATER Open 2 hours the by pass to oily water header for Flushing of Oily water 8'' header LOCATION PUMP BIOCIDE ORDER OIL REMARK 53,664 sbopd 358 m3/h OIL 30000 SBOPD 2,500 sbwpd WATER 1500 SBWPD 16.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.00 5 5.0 2 U/S DS301 GX 822B 16.56 1,000 16.6 5 82.8 3 GX722 discharge to DS-320 (wash water) GX 822B 40 500 20.00 5 100.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 455 OIL REMARK WATER LOCATION PUMP BIOCIDE ORDER From D1 + D2 DO NOT CLOSE 2'' FLUSHING LINE 73,664 sbopd 491 m3/h OIL 50000 SBOPD 3,500 sbwpd WATER 2500 SBWPD 23.2 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS301 GX 822B 23.19 1,000 23.2 5 115.9 2 GX722 discharge to DS-320 (wash water) GX 822B 20 500 10.00 5 50.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 3 TRAITEMENT 4018 OIL REMARK WATER From D1 + D2 LOCATION PUMP BIOCIDE ORDER Open 2 hours the 2'' flushing line to 8'' inch oily water header 65,875 sbopd 439 m3/h OIL 40000 SBOPD 2,600 sbwpd WATER 1600 SBWPD 17.2 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS301 GX 822B 17.23 1,000 17.2 5 86.1 2 GX722 discharge to DS-320 (wash water) GX 822B 20 500 10.00 5 50.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 3 TRAITEMENT 455 OIL REMARK WATER LOCATION PUMP BIOCIDE ORDER From D1 + D2 Open 2 hours the 2'' flushing line to 8'' inch oily water header 68,168 sbopd 454 m3/h OIL 38000 SBOPD 2,520 sbwpd WATER 1520 SBWPD 16.7 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.20 1,000 1.2 5 6.0 3 U/S DS301 GX 822B 16.70 1,000 16.7 5 83.5 2 GX722 discharge to DS-320 (wash water) GX 822B 20 500 10.00 5 50.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 4018 OIL REMARK WATER From D1 + D2 LOCATION PUMP BIOCIDE ORDER Open 2 hours the 2'' flushing line to 8'' inch oily water header 23,476 sbopd 157 m3/h OIL 0 SBOPD 1,000 sbwpd WATER 0 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 2 GX722 discharge to DS-320 (wash water) GX 822B 10 500 5.00 5 25.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 455 OIL REMARK WATER LOCATION PUMP BIOCIDE ORDER From D1 + D2 Open 2 hours the 2'' flushing line to 8'' inch oily water header 23,122 sbopd 154 m3/h OIL 0 SBOPD 1,000 sbwpd WATER 0 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 2 GX722 discharge to DS-320 (wash water) GX 822B 10 500 5.00 5 25.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 LOCATION PUMP BIOCIDE ORDER Open 2 hours the 2'' flushing line to 8'' inch oily water header 23,122 sbopd 154 m3/h OIL 0 SBOPD 1,000 sbwpd WATER 0 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 2 GX722 discharge to DS-320 (wash water) GX 822B 10 500 5.00 5 25.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 4018 OIL REMARK WATER LOCATION PUMP BIOCIDE ORDER From D1 + D2 23,122 sbopd 154 m3/h OIL 0 SBOPD 1,000 sbwpd WATER 0 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 2 GX722 discharge to DS-320 (wash water) GX 822B 15 500 7.50 5 37.5 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 LOCATION PUMP BIOCIDE ORDER 25,753 sbopd 172 m3/h OIL 0 SBOPD 1,000 sbwpd WATER 0 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 2 GX722 discharge to DS-320 (wash water) GX 822B 15 500 7.50 5 37.5 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 4018 OIL REMARK WATER LOCATION PUMP BIOCIDE ORDER From D1 + D2 20,291 sbopd 135 m3/h OIL 0 SBOPD 1,000 sbwpd WATER 0 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS301 GX 822B 6.63 2,000 13.3 5 66.3 2 GX722 discharge to DS-320 (wash water) GX 822B 15 1,000 15.00 5 75.0 1 DA350 GX 822B 14.5 1,000 2.90 5 14.5 3 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 LOCATION PUMP BIOCIDE ORDER Open 2 hours the 2'' flushing line to 8'' inch oily water header 20,563 sbopd 137 m3/h OIL 0 SBOPD 1,000 sbwpd WATER 0 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 2 GX722 discharge to DS-320 (wash water) GX 822B 15 500 7.50 5 37.5 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 4018 OIL REMARK WATER Double concentration because was not done last week LOCATION PUMP BIOCIDE ORDER From D1 + D2 Double concentration because of low water cut Open 2 hours the 2'' flushing line to 8'' inch oily water header 20,870 sbopd 139 m3/h OIL 0 SBOPD 1,200 sbwpd WATER 0 SBWPD 8.0 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 7.95 1,000 8.0 5 39.8 2 GX722 discharge to DS-320 (wash water) GX 822B 15 500 7.50 5 37.5 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 455 Double concentration because of low water cut OIL REMARK WATER Double concentration because of low water cut From D1 + D2 LOCATION PUMP BIOCIDE ORDER Open 2 hours the 2'' flushing line to 8'' inch oily water header 21,310 sbopd 142 m3/h OIL 0 SBOPD 1,200 sbwpd WATER 0 SBWPD 8.0 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 7.95 1,000 8.0 5 39.8 2 GX722 discharge to DS-320 (wash water) GX 822B 15 500 7.50 5 37.5 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 4018 OIL REMARK WATER Double concentration because of low water cut LOCATION PUMP BIOCIDE ORDER From D1 + D2 Double concentration because of low water cut Open 2 hours the 2'' flushing line to 8'' inch oily water header 21,310 sbopd 142 m3/h OIL 0 SBOPD 1,200 sbwpd WATER 0 SBWPD 8.0 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 7.95 1,000 8.0 5 39.8 2 GX722 discharge to DS-320 (wash water) GX 822B 40 500 20.00 5 100.0 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 455 Double concentration because of low water cut OIL REMARK WATER Double concentration because of low water cut From D1 + D2 LOCATION PUMP BIOCIDE ORDER 2'' flushing line open all the time 21,310 sbopd 142 m3/h OIL 0 SBOPD 1,200 sbwpd WATER 0 SBWPD 8.0 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 7.95 1,000 8.0 5 39.8 2 GX722 discharge to DS-320 (wash water) GX 822B 35 700 24.50 5 122.5 1 DA350 GX 822B 14.5 500 1.45 5 7.3 4 TRAITEMENT 4018 OIL REMARK WATER Double concentration because of low water cut LOCATION PUMP BIOCIDE ORDER From D1 + D2 Double concentration because of low water cut 2'' flushing line open all the time 21,310 sbopd 142 m3/h OIL 0 SBOPD 1,200 sbwpd WATER 0 SBWPD 8.0 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 7.95 1,000 8.0 5 39.8 2 DA350 GX 822B 14.5 500 1.45 5 7.3 4 U/S Sand filter GX822B 800 600 480.00 5 2400.0 1 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 Double concentration because of low water cut It will allow to treat water injection system as well as oily water package ( via GX722) LOCATION PUMP BIOCIDE ORDER Double concentration because of low water cut 21,429 sbopd 143 m3/h OIL 0 SBOPD 1,200 sbwpd WATER 0 SBWPD 8.0 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 3 U/S DS301 GX 822B 7.95 1,000 8.0 5 39.8 2 DA350 GX 822B 14.5 500 1.45 5 7.3 4 U/S Sand filter GX822B 800 700 560.00 5 2800.0 1 TRAITEMENT 4018 It will allow to treat water injection system as well as oily water package ( via GX722). Please open 2'' flushing line in order to reach 30 m3/h (15 m3/h wash water+15 m3/h flushing line) LOCATION PUMP BIOCIDE ORDER OIL REMARK WATER From D1 + D2 21,629 sbopd 144 m3/h OIL 0 SBOPD 1,000 sbwpd WATER 0 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.05 1,000 1.1 5 5.3 1 U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 2 DA350 GX 822B 14.5 500 1.45 5 7.3 3 TRAITEMENT 4018 AND 455 1,000 ppm dur to low water flowrate 1,000 ppm dur to low water flowrate LOCATION PUMP BIOCIDE ORDER OIL REMARK WATER From D1 + D2 25,024 sbopd 167 m3/h OIL 2000 SBOPD 1,000 sbwpd WATER 80 SBWPD 6.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS301 GX 822B 6.63 1,000 6.6 5 33.1 2 DA350 GX 822B 14.5 500 7.25 1 7.25 3 U/S Sand filter GX822B 800 500 400 5 2000 1 TRAITEMENT 4018 Open 2'' flushing line discharge of GX722 in order to reach 30 m3/h (15 m3/h wash water+15 m3/h flushing line) + run continuously GX721 and GX600. LOCATION PUMP BIOCIDE ORDER 1 hour to treat the DA-350 is enough as there is no flow 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 50,808 sbopd 339 m3/h OIL 25000 SBOPD 1,500 sbwpd WATER 1000 SBWPD 9.9 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 2 U/S DS301 GX 822B 9.94 1,000 9.9 5 49.7 3 DA350 GX 822B 14.5 500 7.25 1 7.25 4 U/S Sand filter GX822B 800 500 400 5 2000 1 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 30 m3/h (15 m3/h wash water+15 m3/h flushing line) + run continuously GX721 and GX600. LOCATION PUMP BIOCIDE ORDER 1 hour to treat the DA-350 is enough as there is no flow 1,000 ppm due to low water flowrate 50,808 sbopd 339 m3/h OIL 25000 SBOPD 2,400 sbwpd WATER 1250 SBWPD 15.9 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.90 1,000 15.9 5 79.5 4 DA350 GX 822B 14.5 500 7.25 1 7.25 5 GX722 discharge to DS-320 (wash water) GX 822B 30 800 24.00 5 120.0 2 U/S Sand filter GX822B 800 500 400 5 2000 1 TRAITEMENT 4018 run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) LOCATION PUMP BIOCIDE ORDER 1 hour to treat the DA-350 is enough as there is no flow 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 30 m3/h (15 m3/h wash water+15 m3/h flushing line) + 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 52,312 sbopd 349 m3/h OIL 25000 SBOPD 2,400 sbwpd WATER 1250 SBWPD 15.9 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.90 1,000 15.9 5 79.5 4 DA350 GX 822B 14.5 500 7.25 1 7.25 5 GX722 discharge to DS-320 (wash water) GX 822B 35 800 28.00 5 140.0 2 U/S Sand filter GX822B 800 500 400 5 2000 1 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) LOCATION PUMP BIOCIDE ORDER 1 hour to treat the DA-350 is enough as there is no flow 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 35 m3/h (24 m3/h wash water+11 m3/h flushing line) + 27,312 sbopd 182 m3/h OIL 0 SBOPD 1,500 sbwpd WATER 0 SBWPD 9.9 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 9.94 1,000 9.9 5 49.7 4 DA350 GX 822B 14.5 500 7.25 1 7.25 5 GX722 discharge to DS-320 (wash water) GX 822B 30 700 21.00 5 105.0 2 U/S Sand filter GX822B 800 500 400 5 2000 1 TRAITEMENT 4018 run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) LOCATION PUMP BIOCIDE ORDER 1 hour to treat the DA-350 is enough as there is no flow 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 30 m3/h (24 m3/h wash water+6 m3/h flushing line) + 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 46,091 sbopd 307 m3/h OIL 20000 SBOPD 2,495 sbwpd WATER 1000 SBWPD 16.5 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 16.53 1,000 16.5 5 82.7 4 DA350 GX 822B 14.5 500 7.25 1 7.25 5 GX722 discharge to DS-320 (wash water) GX 822B 30 800 24.00 5 120.0 2 U/S Sand filter GX822B 800 500 400 5 2000 1 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) LOCATION PUMP BIOCIDE ORDER 1 hour to treat the DA-350 is enough as there is no flow 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 30 m3/h (24 m3/h wash water+6 m3/h flushing line) + 48,181 sbopd 321 m3/h OIL 20000 SBOPD 2,586 sbwpd WATER 1000 SBWPD 17.1 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 17.13 1,000 17.1 5 85.7 4 DA350 GX 822B 14.5 500 7.25 1 7.25 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX822 800 500 400 5 2000 1 TRAITEMENT 4018 run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) LOCATION PUMP BIOCIDE ORDER 1 hour to treat the DA-350 is enough as there is no flow 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 48,261 sbopd 322 m3/h OIL 20000 SBOPD 2,575 sbwpd WATER 1000 SBWPD 17.1 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 17.06 1,000 17.1 5 85.3 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 500 12.50 5 62.5 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hour for the dead leg of GX-200 discharg 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 45,280 sbopd 302 m3/h OIL 16000 SBOPD 2,196 sbwpd 4.6% WATER 640 SBWPD 14.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 14.55 1,000 14.6 5 72.8 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 500 12.50 5 62.5 2 U/S Sand filter GX822 800 500 400 5 2000 1 TRAITEMENT 4018 run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) + the 7 sand filters to be treated at leat 1h30. LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hour for the dead leg of GX-200 discharg 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 53,430 sbopd 356 m3/h OIL 20000 SBOPD 2,375 sbwpd 4.3% WATER 800 SBWPD 15.7 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.73 1,000 15.7 5 78.7 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 500 12.50 5 62.5 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hour for the dead leg of GX-200 discharg 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 53,430 sbopd 356 m3/h OIL 20000 SBOPD 2,375 sbwpd 4.3% WATER 800 SBWPD 15.7 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.73 1,000 15.7 5 78.7 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX822 800 500 400 5 2000 1 TRAITEMENT 4018 run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 53,430 sbopd 356 m3/h OIL 20000 SBOPD 2,375 sbwpd 4.3% WATER 800 SBWPD 15.7 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.73 1,000 15.7 5 78.7 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 53,430 sbopd 356 m3/h OIL 20000 SBOPD 2,375 sbwpd 4.3% WATER 800 SBWPD 15.7 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.73 1,000 15.7 5 78.7 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX822 800 500 400 5 2000 1 TRAITEMENT 4018 run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 53,430 sbopd 356 m3/h OIL 20000 SBOPD 2,375 sbwpd 4.3% WATER 800 SBWPD 15.7 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.73 1,000 15.7 5 78.7 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 455 run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 50,143 sbopd 334 m3/h OIL 17000 SBOPD 2,193 sbwpd 4.2% WATER 680 SBWPD 14.5 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 14.53 1,000 14.5 5 72.7 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX822 800 500 400 5 2000 1 TRAITEMENT 4018 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate run continuously GX721 and GX600 + Flush during one hours the PSV collector of the deareation tower (new purged line installed) + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 54,463 sbopd 363 m3/h OIL 22000 SBOPD 2,324 sbwpd 4.1% WATER 660 SBWPD 15.4 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.40 1,000 15.4 5 77.0 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 500 12.50 5 62.5 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 455 run continuously GX721 and GX600 + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 59,647 sbopd 398 m3/h OIL 24000 SBOPD 2,377 sbwpd 3.8% WATER 720 SBWPD 15.7 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.75 1,000 15.7 5 78.7 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 500 12.50 5 62.5 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 4018 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate run continuously GX721 and GX600 + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 59,776 sbopd 399 m3/h OIL 23000 SBOPD 2,481 sbwpd 4.0% WATER 690 SBWPD 16.4 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 16.44 1,000 16.4 5 82.2 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 500 12.50 5 62.5 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 455 run continuously GX721 and GX600 + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 59,647 sbopd 398 m3/h OIL 24000 SBOPD 2,377 sbwpd 3.8% WATER 720 SBWPD 15.7 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 15.75 1,000 15.7 5 78.7 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX822 800 500 400 5 2000 1 TRAITEMENT 4018 run continuously GX721 and GX600 + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated+ CA712 dead legs to be performed LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (20 m3/h wash water+5 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2 36,876 sbopd 246 m3/h OIL 0 SBOPD 1,792 sbwpd 4.6% WATER 0 SBWPD 11.9 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 11.87 1,000 11.9 5 59.4 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 455 OIL REMARK WATER From D1 + D2 1,000 ppm due to low water flowrate run continuously GX721 and GX600 + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated+ CA712 dead legs to be performed LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 37,483 sbopd 250 m3/h OIL 0 SBOPD 1,597 sbwpd 4.1% WATER 0 SBWPD 10.6 m3/h To be treated m3/h ppm l/h hours l/batch U/S DS300 GX 822B 1.00 1,000 1.0 5 5.0 3 U/S DS301 GX 822B 10.58 1,000 10.6 5 52.9 4 DA350 GX 822B 14.5 1,000 7.25 2 14.50 5 GX722 discharge to DS-320 (wash water) GX 822B 25 800 20.00 5 100.0 2 U/S Sand filter GX821 800 500 400 5 2000 1 TRAITEMENT 4018 run continuously GX721 and GX600 + the 7 sand filters to be treated at leat 1h30. On line Analyser to be isolated+ CA712 dead legs to be performed LOCATION PUMP BIOCIDE ORDER 1,000 ppm in 2 hours for the dead leg of GX-200 discharge 1,000 ppm due to low water flowrate Open 2'' flushing line discharge of GX722 in order to reach 25 m3/h (18 m3/h wash water+7 m3/h flushing line) 1,000 ppm due to low water flowrate OIL REMARK WATER From D1 + D2