ABB Group

May 23, 2014 | Slide 1


ABB Power Systems Substantions
PASS solutions
ABB Group
May 23, 2014 | Slide 2
Design / Product portfolio
LTB
Circuit Breaker
DTB
Circuit Breaker
Current Transformer
PASS
Circuit Breaker
Current Transformer
Voltage Transformer
Disconnectors
Earthing Switches
Ratings 50kA and 4000A
GIS
Circuit Breaker
Current Transformer
Voltage Transformer
Disconnector
Earthing Switch
Busbar / Busducts
Higher ratings 63 kA
and 4000A
V
a
l
u
e

a
d
d
e
d

s
o
l
u
t
i
o
n
Functional Integration
ABB Group
May 23, 2014 | Slide 3
Design / Product portfolio
PASS Family
72,5100kV; 50-60Hz;
2500A/3150;
40/31.5/20 kA
PASS M0S
252kV;50Hz;4000A;
40/50kA
PASS M0
72,5170kV; 50-60Hz;
3150A; 40/50 kA
Wi th Rotating Chamber
PASS M00
All the functions in one enclosure with : PASS M0 All the functions in one enclosure with : PASS M0
- - . .P Plug lug A And nd S Switch witch S System ystem
ABB Group
May 23, 2014 | Slide 5
PASS M0 PASS M0 The functions The functions
CB Driver
Bushing
hollow type
Circuit Breaker
CT ring type
Combined
Disconnector/
Earthing Switch
ABB Group
May 23, 2008 | Slide 6
PASS M0 PASS M0 The functions The functions Circuit breaker (SF6 auto Circuit breaker (SF6 auto puffer puffer type) type)
Higher Higher availability availability
through 10,000 times through 10,000 times
proven LTB chamber proven LTB chamber
for PASS M0 and EDF for PASS M0 and EDF
chamber for PASS M00 chamber for PASS M00
CIRCUIT BREAKER
Frequency Hz 50 60
Type LTB-D
Operating mechanism
(spring type, three pole operated)
BLK 222
Operating mechanism
(spring type, single pole operated)
BLK 82
Rated operating sequence acc. to IEC O - 0.3 s - CO -1 min - CO
Stored switching sequence O CO
Rated current A Up to 3150
Rated short-time withstand current kA 40
Rated making current kA 100 104
Rated short circuit duration s 3

ABB Group 7
PASS M0 PASS M0 The functi ons The functi ons Combined DS/ES (SF6 technology) Combined DS/ES (SF6 technology)
ES - open
DS - closed
COMBINED DISCONNECTOR & EARTHING SWITCH
Type SBL
Operating mechanism (three pole operated) BES-7
Rated voltage kV 72.5 123 145 170
Rated power frequency withstand voltage
common value kV 140 230 275 325
across the isolating distance kV 160 265 315 375
Rated lightning impulse withstand voltage (3 sec)
common value kV 325 550 650 750
across the isolating distance kV 375 630 750 860
Rated current A Up to 3150
Rated short time withstand current kA 40
Rated peak current kA 108
Rated short circuit duration s 3
Motor operating time (disconnector) s < 4

ABB Group
May 23, 2014 | Slide 8
PASS M0 PASS M0 The functi ons The functi ons The The bushings bushings and C.T. and C.T.
Bushings Bushings made of made of sili con sili con
rubber rubber have have higher higher
availability availability through through: :
- - maintenance maintenance free free
- - self self - -cleaning cleaning surface surface
- - silicon silicon- -fiberglass fiberglass construction construction
- - better better pollution pollution and and rain rain
resistance resistance
- - ... ...
CTs CTs Ring Type Ring Type
with cast resin with cast resin
cores cores
For For interfacing interfacing with with
conventional conventional Control & Control &
Protection System Protection System
ABB Group
May 23, 2014 | Slide 9
DS/ES DS/ES
electric motor driven electric motor driven
PASS M0 PASS M0 The functions The functions DS/ES DS/ES drives drives and SF6 and SF6 density density monitor monitor. .
SF6 density SF6 density
gauge with two gauge with two
alarm alarm steps steps
ES - open
DS - closed
ABB Group gust 8, 2008 | Slide 10
PASS M0 PASS M0 The functi ons The functi ons Porthole Porthole per per each each combined DS/ES combined DS/ES
Visual Inspection always
possible through:
-Portholes
-Red/Green flags on the
drive
-Electrical signals from the
LCC to the Remote control
panel
ABB Group
May 23, 2014 | Slide 11
PASS M0 PASS M0 The functi ons The functi ons The The CB CB drives drives: spring : spring operating operating
Three Three- -pole pole operating operating
mechanism mechanism (BLK222) (BLK222)
CB CB Spring Spring operating operating
mechanism mechanism
(BLK222 or BLK82) (BLK222 or BLK82)
Single Single- -pole operating pole operating
mechanism mechanism (BLK82) (BLK82)
Confidential
ABB Group
May 23, 2014 | Slide 12
PASS M0 PASS M0 The functi ons The functi ons LCC different LCC different options options
Include Circuit breaker &
disconnectors control, plus
protection, metering and
monitoring features
Completely assembeld
and tested at the factory
Ready for IEC 61850
comunication protocol
NEW !!! NEW !!!
ABB Group
May 23, 2014 | Slide 13
PASS M0 & M0S PASS M0 & M0S standari zed standari zed modul e types modul e types
1.
1.
SBB
SBB
(
(
S
S
ingle
ingle
B
B
us
us
B
B
ar)
ar)
2.
2.
DBB
DBB
(
(
D
D
ouble
ouble
B
B
us
us
B
B
ar)
ar)
3.
3.
IOS
IOS
(
(
I
I
n
n
-
-
O
O
ut
ut
S
S
ubstation)
ubstation)
4.
4.
DCB
DCB
(
(
D
D
ouble
ouble
C
C
ircuit
ircuit
B
B
reaker)
reaker)
ABB Group
May 23, 2014 | Slide 14
Legend:
circuit breaker CB current transformer CT
voltage transformer VT line L
disconnector DS earthing switch ES
PASS M0 SBB PASS M0 SBB Optional DS/ES ( Line earth. through ES Optional DS/ES ( Line earth. through ES + DS ) + DS )
Conventional AIS
DS CB DS
CT
VT ES
L
BB
BB
PASS M0 SBB
L DS/ES CB CT
Optionally
Extra SF6 DS/ES
housed in the
same vessel
DS
ES
CT
L
ABB Group
May 23, 2014 | Slide 15
PASS M0 SBB PASS M0 SBB DS/ES on Both Sides DS/ES on Both Sides ( ( example example bus bus
coupler coupler) )
Optional
Extra SF6 DS/ES
DS/ES
CT CT CB
DS/ES
ABB Group
May 23, 2014 | Slide 16
Legend:
circuit breaker CB current transformer CT
voltage transformer VT line L
disconnector DS earthing switch ES
Conventional AIS
DS
CB DS
CT
VT ES
L
DS
BB2
BB1
PASS M0 DBB PASS M0 DBB
L
PASS M0 DBB
DS/ES CB CT
BB1
BB2
DS
ES
Optionally
Extra SF6 DS/ES
L
CT
ABB Group
May 23, 2014 | Slide 17
PASS M0 DBB PASS M0 DBB with additional ES + DS and gas VT ( with additional ES + DS and gas VT ( example example ) )
Optional
Extra SF6 DS/ES
and SF6 VTs
DSs/ES
CT CB
DS/ES
VT
ABB Group
May 23, 2014 | Slide 18
Featuring Featuring: :
- - Extra SF6 DS/ES on the Extra SF6 DS/ES on the Trafo Trafo
side side
- - SF6 ES on the SF6 ES on the In In and and Out Out line line
sides sides
- - Capacitive Voltage Capacitive Voltage Sensors Sensors
Incoming
Outgoing
To the Power
Trafo
PASS M0 PASS M0 type type IOS for In IOS for In- -Out S/S Out S/S
ABB Group
May 23, 2014 | Slide 19
Look at the compactness fed through
substation
PASS M0 PASS M0 type type IOS for In IOS for In- -Out S/S Out S/S
ABB Group
May23, 2014 | Slide 20
PASS M0 IOS PASS M0 IOS
The Voltage The Voltage Sensors Sensors
by means by means
capacitive capacitive rings rings
PASS M0 type PASS M0 type IOS for In IOS for In- -Out S/S Out S/S ( (the Capacitive Voltage the Capacitive Voltage
Sensors Sensors) )
ABB Group
May 23, 2014 | Slide 21
PASS M0 DCB PASS M0 DCB - - Double Circuit Breaker Double Circuit Breaker
H H configuration with configuration with
two two modules modules, only... , only...
One pole and the One pole and the simplified simplified single single- -line line- -diagram diagram
ABB Group
May 23, 2014 | Slide 22
X
X
TRF 1 TRF 1 TRF 2 TRF 2
X
X
IL 1 IL 1
IL 2 IL 2
No. 2 No. 2 modules modules DCB DCB
PASS M0 DCB PASS M0 DCB H H configuration with two configuration with two modules modules PASS M0 DCB PASS M0 DCB
No. 4 No. 4 Bays Bays !!! !!!
ABB Group
May 23, 2014 | Slide 23
H H configuration configuration
No. 2 No. 2 modules modules
DCB DCB
only only
but but having having
functionalities functionalities
for for
No. 4 No. 4 Bays Bays
PASS M0 DCB PASS M0 DCB H H configurati on with two configurati on with two modules modules PASS M0 DCB PASS M0 DCB
ABB Group
May, 2014 | Slide 24
Design advantages
Design
All the necessary functions in one module
Flexible configuration: SBB, DBB , DCB etc.,
suitable for Air/ Cable external connection
Key functions (CB, DS, ES) are SF6 enclosed and
modules factory pre-assembled and pre-tested
Easy installation & fast exchangeability
Wide range of application (Ice and Sand, -
50C/+50C)
Italy 2000
Benefits
Requiring minimum space of installation with
price performance leadership (LCC).
Higher reliability and less probability of
unplanned outages
Simplified on site assembly & reduction of
installation time
Modular approach, in case of Expansion /
Retrofitting S/S with costs and time saving
ABB Group
May 23, 2014 | Slide 25
AIS PASS GIS
AIS switchgear = 100%
PASS switchgear = 45%
GIS switchgear = 40%
Conventional AIS
switchyard
35x31=1052sqm
Conventional PASS
M0 DCB switchyard
24x20=480sqm
Conventional GIS
switchyard
21x21=421sqm
S/S space comparison
H configuration 145 kV
ABB Group
May 23, 2014 | Slide 26
62

m
86 m
AIS
space requirements:
62 m * 86 m = 5300 sqm
PASS
Space requirements:
27 m * 62 m = 1700 sqm
Technical reasons
Key functions integreated
in one module only
Your benefit
Reduction of S/S switchyard
6
2

m
Space requirements:
62 m * 86 m = 5300 sqm
S/S space comparison
Double Bus Bar
2
7

m
62 m
ABB Group
May 23, 2014 | Slide 27
AIS PASS GIS
AIS switchgear = 100%
PASS switchgear = 50%
GIS switchgear = 40%
Conventional AIS
switchyard
31x36=1116sqm
Conventional PASS
switchyard
23x23=576sqm
Conventional GIS
switchyard
21x21=421sqm
S/S space comparison
Ring configuration
3
3
ABB - U. O. ADDA
3
4
ABB - U. O. ADDA
ABB Group
May 23, 2014 | Slide 30
Erection and Comissioning
Service position
Rotation of
poles
Erection on
support
structure
Transport
module
Unloading &
unpacking
Technical reasons
Modules pre-assembled and pre-
tested in factory
Benefits
Easy Erection and Commissioning
Reduction of installation time
16 hours
Total time
16 hours

ABB Group
May 23, 2014 | Slide 31
Erection and Commissioning
1-Foundation
prepared for
erection
2-Fixing the
support by crane
3-Unloading
PASS M0
module
4-Removing the
transport
structure
5-Erection
of poles
Fixing
by screws
6-Rota-
tion
of side
poles
7-Service position
8-CB mechanism
transmission
9-DS&ES
mechanism
transmission
10-Filling with
SF6 gas at
nominal pressure
11-Wiring
of CTs to
local control
panel
12-Func-
tional
tests

ABB Group
May 23, 2014 | Slide 32
Economical comparison
0
20
40
60
80
100
120
140
PASS M0+DS/ES AIS Conventional
Maintenance cost
20 years
Engineering cost
Land acquisition
foundation, fence,
groundings,
roads, etc.
LV cable
connection
Tubolar
aluminium
connection &
clamps
Steel structure
supply and
erection
HV apparatus
erection
HV apparatus
supply
ABB Group
May 23, 2014 | Slide 33
-50C
SS SS Rodnik Rodnik R Russia ussia
Australia Australia
+50C
PASS Examples
ABB Group
May 23, 2014 | Slide 34
SS SS Airport Airport - - R Russia ussia
PASS Examples
ABB Group
May 23, 2014 | Slide 35
SS SS Krasnaya Krasnaya Polyana Polyana - - R Russia ussia
PASS Examples
ABB Group
May 23, 2014 | Slide 36
Ferrari Ferrari Plant Plant - - Italy Italy
PASS Examples
ABB Group
May 23, 2014 | Slide 37
H H configuration configuration
No. 2 No. 2 modules modules
DCB DCB
only only
but but having having
functionalities functionalities
for for
No. 4 No. 4 Bays Bays
PASS PASS exampl e exampl e SS SS We We nowiec / Poland nowiec / Poland
ABB Group
May 23, 2014 | Slide 38
PASS Example C (P.R.China)
ABB Group
May 23, 2014 | Slide 39
PASS Example (P.R.China)
ABB Group
May 23,2014 | Slide 40
ABB Grou
PASS Example (P.R.China)
ABB Group
May 23, 2014 | Slide 41
PASS examples
Single phase GIS / TEL 145kV / Italy
ABB Group
May 23, 2014 | Slide 42
Your challenges i n HV Your challenges i n HV Substati on Substati on
Engineering, Engineering, Erection Erection and and Commissioning Commissioning: :
More bays on less space
Simpler layouts
Highly competitive system
Ease of erection and commissioning
Shorter installation time
Standardization & Modularization
Conclusions Conclusions: : Why PASS M0 Why PASS M0 ? ?
ABB Group
May 23, 2014 | Slide 43