Technical seminar on

Auxiliary Power Unit


On 11.11.2013 technical seminar on Auxiliary Power Unit was conducted
by Diesel Loco Faculty at ZRTI Bhusawal . This seminar presented by
Shree Dinesh Koasty who is working as service engineer in Medha Servo
Drives Pvt. Ltd.

Medha Servo Drives Pvt. Ltd.


2-3-2/A, Cherlapally, Hyderabad 500051. India. Ph- 040-2726 4144

Welcome to All
Medha
Auxiliary Power Unit
Type MAP 756

Medha Servo Drives Pvt. Ltd.


2-3-2/A, Cherlapally, Hyderabad 500051. India. Ph- 040-2726 4144

Locomotive Idling

 Most of the goods trains are waiting for long periods


in station yards.
 Indian Railway statistics says almost 40% of the
total run time of a diesel locomotive is IDLE only.
 Lot of fuel is wasted when the locomotive is waiting
for long periods in the station yards especially
goods trains.
 Loco pilot can shut down the diesel engine to save
fuel.

Why not shutdown

 The Loco pilots can switch off the diesel engine and
save fuel instead of running at IDLE.
 But they dont do because:
 BP pressure reduces in the formation due to
leakages.


It takes longer time to charge the BP again.

The crew does not have confidence that loco can


re-crank.

What is wasted ?

 The fuel consumed per hour on ALCO locomotives is


around 25 liters / Hour.
 If you take Rs.56/- per liter, the cost per idle hour
running is Rs. 1400/-.
 If you take an average 10 hours per day idling hours
then the cost is Rs.14,000/-.
 Roughly if you take 330 days, it costs
Rs.46,20,000/-.
 If a home shed is having 100 locos, almost
Rs. 46.2 crores worth of fuel is wasted.

What can be
saved by crew

 Normally the Loco pilot is on duty for 8 hours per


day.
 Out of that minimum 6 hours he is in locomotive.
 Out of 6 hours minimum one hour is the waiting
period.
 In one Hour we can save 23 liters of fuel oil per
day.
 On an average in a month the working days are
around 24 days
 We can save 24 * 23 = 552 liters per month
 Financially equivalent to 552 * 56 = Rs.30,912/per month
 On an average in a year we can save Rs.3,70,944/-.
6





AESS with APU

APU SWITCH is provided under


alarm push button.
Keep always this switch in NORMAL
position to save fuel.
If this switch is in OFF position,
1701 Operator disabled APU
message is displayed while the
breakers are switched ON.
There after for every 10 minutes
the system reminds the driver with
a message 2076 APU Enable switch
is in OFF position. Warning: Cannot
enter into fuel save mode.
Keep this switch in OFF position
only when there is a problem with
APU functionality.

AESS with APU

 APU is located in the nose


compartment under dynamic
brake grid resistors and after
the air brake panel.
 This is an Add on unit to
Microprocessor based loco
control system.
 It is called as AESS with APU.
 It starts automatically and
stops automatically as per the
drivers request.
8

STATUTARY WARNINGS

 Do not perform any jobs on main engine or APU


engine keeping APU SWITCH in NORMAL position.
 Engine may automatically start / stop and can
cause human injury / death.
 Switch OFF APU Switch and then perform the work
on engines.

MAP 756

Engine Air
intake filter

Compressor Air
inlet filters

Control Unit
Diesel Engine

Compressor

Alternator
10

Diesel Engine

Fuel oil
secondary filter

Water level
sensor

Water
filling cap

Expansion
tank
Air Lock
releasing pump

STARTER
motor

STOP
Cylinder
11

MAP 756

Gauge panel

APU Knife
Switch

12V Alternator

12V Battery
Manual
Shutdown

12

Compressor

Breather Valve
HP Cylinder

Oil sight glass


LP Cylinders

Oil Fill Cap.


Unloader Valves
13

MAP 756

Regulator (AVR)

FOLR

SMC
Control Unit

Alternator
Timer Unit

Diode
Panel

ASC

ACC

14

APU inside the Nose


compartment

 There is a glass door on the


APU.
 Behind the glass door, there
is a battery cut out switch.
 When the display prompts to
open this cut out switch,
Please open this switch
manually.
 There is an emergency stop
lever to stop the APU engine
in case of any problem.
 When ever display prompts
to manually shut down the
APU engine, Pull the lever
toward you to shut down the
APU engine.
15

AESS with APU working

 Stop the train with A9.


 Apply loco brakes and
ensure BCP is more
than 1.5 Kg/Cm.
 Keep the RH in neutral
position.
 After every parameter
is with in limits for 10
minutes, the Display is
shown with a
decremental counter.
16

AESS with APU working

 After the counter is


zero, the system
automatically starts the
APU.
 Main engine is
shutdown.
 The display screen is
changed to APU screen.
 All relevant parameters
are displayed

17

AESS with APU working

 MCBG screen is change to starting screen.


 Small motors like DEM, CCEM, FPM and RBM are
switched OFF.
 DEB (Eng), DEB (Carb) indications start glowing.
 Aux.Fail indication glows but battery ammeter will
be showing charging side.
Note: Do not worry about these indications.

18

Warnings

 While APU is running if


 Battery ammeter is showing discharge side (or)
 MR is continuously dropping and reached below
5.5 Kg/Cm.
 The APU is automatically stopped and main engine
is cranked automatically.
Note: If APU is continuing to run in spite of the above,
manually shut down the APU and crank the main
engine.

19

How to start the train

 As soon as the signal is in favour,











Simply through the RH to working direction.


2077 System returning from FUEL SAVE mode message is
displayed.
Small motors are switched ON.
With in 15 seconds the main engine is cranked
automatically.
APU engine is shut down.
Display returns to normal screen.

 Loco pilot can start the train as per rail road rules
and regulations.

20

Trouble shooting

Code

Message

1700

Operator enabled APU

1701

Operator disabled APU

1277

APU cranking contactor circuit open fault.

1278

APU Cranking contactor stuck closed.

1287

APU shut down contactor circuit open fault

1284

APU shut down contactor stuck closed fault

1286

SMC contactor circuit open fault

1285

SMC contactor stuck closed

1293

FPC contactor circuit open

1292

FPC contactor stuck closed


21

Trouble shooting

Code

Message

1279

APU fuel oil level low fault

1280

APU water level low / Temperature High fault

1281

APU lube oil pressure low fault

1290

APU Engine failed Engine RPM low

1291

APU Engine failed Engine over speed

1276

APU Engine shut down unexpectedly.

1282

APU battery charging faulty

1283

APU Air compressor faulty

1289

No APU Generator output

1288

Main Engine failed to crank while retrurning from APU mode.

22

Code

Trouble shooting
Message

2075

Keep REV handle to neutral to enter into FUEL SAVE mode.

2076

APU Enable switch is in OFF position

2077

System returning from FUEL SAVE mode

2078

APU shutdown contactor failed. Manually pull the emergency


shut down lever to shutdown APU Engine.

2079

Loco brakes are not applied. May not enter into FUEL SAVE
mode

2606

BATI/EWT/EOT/MRPR are not full filled. Fuel save mode


prohibited.