15. The actual water flow was measured by using the volumetric tank with a stop watch.
Brenoullis Theorem Demonstration
1. The general start-up procedures was performed.
2. All the manometers tubings were properly checked and connected to the
corresponding pressure taps and are air-bubbles free.
3. The discharged valve was adjusted to a high measurable flow rate.
4. After the level stabilizes, the water flow rate was measured using volumetric flow
rate,
5. Slide the hypodermic tube gently connected to the manometer #H, so that its end
reaches the cross section of the venturi tube at #A. The reading shown by manometer
#H is the sum of static head and velocity head. i.e. the total ( or stagnation ) head (h*)
, because the hypodermic tube is held against the flow of fluid forcing it to a stop
(zero velocity) . The reading in manometer #A measured just the pressure head (hi)
because it is connected to the venturi tube pressure tap, which does not obstruct the
flow, thus measuring the flow static pressure.
6. Step 5 was repeated for other cross sections (#B, #C, #D, #E and #F).
7. Step 3 and step was repeadted with three other decreasing flow rates by regulating the
venturi discharged valve.
8. The velocity ViB was calculated using the Brenollis equation where; ViB =
.
9. The velocity Vic was calculated using the continuity equation where Vic = Qav/Ai.
10. The difference between two calculated velocities was determined.
GENERAL SHUT DOWN PROCEDURES
1. Water supplied valve and discharged valve was closed.
2. The water supplied pump was turn off.
3. The water from was drained from the unit when not in use.