Professional Documents
Culture Documents
Fire Detection
Fire Detection
11:14
Page 1
www.GE-Security.com
GE Security reserves the right to change product specifications without notice.
For the latest product specifications, visit www.GE-Security.com or contact your Sales Representative.
03/2004
GE Security
CoverFireAritech.qxd
GE Security
Aritech
FIRE SYSTEMS
Product catalogue
GE Security,
unrivalled expertise in
Fire Protection
300 SERIES
DI322I
The 300 Series conventional fire detectors are the ideal solution for any conventional
installation. They are built specifically for use with the Aritech FP400, FP500, FP600
and FP700 series conventional fire panels, but can also be connected to most 3rd
party industry standard conventional control panels.
Specifications
18 to 28 VDC
Operating voltage
Current consumption
Quiescent at 24 VDC
30 A
Alarm at 24 VDC
< 100 mA
Radio-active source
Average activity
Remote alarm output
Heat specification
Americium 241
0.33 +/-0.04Ci (12.1 +/- 1.5 kBq)
< 100 mA
Operating temperature
Storage temperature
Humidity (non-condensing)
IP rating
Number of detectors per zone
Recommended protection resistor
Dimensions (h x )
-10 to +60 C
-10 to +70 C
0 - 95%
IP205
20
300 ohm
Head
45 mm x 99 mm
Base
24 mm x 103 mm
VdS
LPCB
Approvals*
* Check current status with local office
Ordering Information
DI322I
DP331I
The 300 Series conventional fire detectors are the ideal solution for any conventional
installation. They are built specifically for use with the Aritech FP400, FP500, FP600
and FP700 series conventional fire panels, but can also be connected to most 3rd
party industry standard conventional control panels.
Specifications
9 to 28 VDC
Operating voltage
Current consumption
Quiescent at 24 VDC
85 A
Alarm at 24 VDC
< 100 mA
Radio-active source
Average activity
Remote alarm output
Heat specification
< 100 mA
Operating temperature
Storage temperature
Humidity (non-condensing)
IP rating
Number of detectors per zone
Recommended protection resistor
Dimensions (h x )
-10 to +70 C
-10 to +70 C
0 - 95%
IP42
20
300 ohm
Head
45 mm x 99 mm
Base
24 mm x 103 mm
EN54
*
Approvals*
* Check current status with local office
Ordering Information
DP331I
DT313I
The 300 Series conventional fire detectors are the ideal solution for any conventional
installation. They are built specifically for use with the Aritech FP400, FP500, FP600
and FP700 series conventional fire panels, but can also be connected to most 3rd
party industry standard conventional control panels.
Specifications
18 to 28 VDC
Operating voltage
Current consumption
Quiescent at 24 VDC
70 A
Alarm at 24 VDC
< 100 mA
Radio-active source
Average activity
Remote alarm output
Heat specification
Operating temperature
Storage temperature
Humidity (non-condensing)
IP rating
Number of detectors per zone
Recommended protection resistor
Dimensions (h x )
< 100 mA
Max. & ROR to EN54p5
-10 to +70 C
-10 to +80 C
0 - 95%
IP205
20
300 ohm
Head
45 mm x 99 mm
Base
24 mm x 103 mm
VdS
LPCB
Approvals*
* Check current status with local office
Ordering Information
DT313I
KCT731
2 x 9 V batteries
Supply
Ordering Information
KCT731
Easy to use
Battery operated
DB304
The DB304 is a 4 contact universal detecor base for use with the Dx300 and Dx1500
series detectors from Aritech. It has the ability to compensate for uneven mounting
surfaces.
Specifications
Dimensions
Diameter
104 mm
Height
24 mm
Ordering Information
DB304
Polarity sensitive
EN54 approved
KZ705
The KZ705 is a 5 contact universal detector base for use with the KL700/Dx300 and
KL700A/Dx1500 series detectors from GE-Interlogix. In addition to the normal base
and remote indication connectors, the KZ705 also has an additional earth terminal
connector to allow for easy terminations of a possible cable screen.
Specifications
100 x 29 mm
Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
@ 5 mA
Environmental Characteristics
Operating Temperature
-10 to 70 C
Storage Temperature
-10 to 70 C
95 % (non-cond.)
Ordering Information
KZ705
Polarity sensitive
KZ705D
The KZ705D is a 5 contact universal detector base for use with the KL700/Dx300
series detectors from GE-Interlogix. In addition to the normal base and remote
indication connectors, the KZ705D also has an additional earth terminal connector to
allow for easy terminations of a possible cable screen. The built in diode is
specifically targeted at systems using active end-of-line devices.
Specifications
100 x 29 mm
Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
@ 5 mA
Environmental Characteristics
Polarity sensitive
-10 to 70 C
95 % (non-cond.)
Operating Temperature
-10 to 70 C
Storage Temperature
Relative Humidity (max)
Ordering Information
KZ705D
EOL-ACT
The EOL-ACT is designed for use with the NK700/FP400 fire panels from GE-Interlogix.
It is an active end-of-line device to allow the monitoring of a conventional zone
through a diode base (such as the KZ705D).
Ordering Information
EOL-ACT
Small
Easy to install
KZ705R
The KZ705R is a 5 contact detector base for use with the KL731/DP331I detectors
from GE-Interlogix. In addition to the normal base and remote indication connectors,
the KZ705R also has an additional earth terminal connector to allow for easy
terminations of a possible cable screen. A built in 12 V relay makes it ideal for use on
low voltage intrusion systems.
Specifications
100 x 29 mm
12 V 10%
12 A
Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
@ 5 mA
Polarity sensitive
Environmental Characteristics
Operating Temperature
-10 to 70 C
Storage Temperature
-10 to 70 C
95 % (non-cond.)
Ordering Information
KZ705R
S300
The S300 is a base accessory designed for use with the KZ300 detector base. It
allows for a surface mount conduit and cable to enter the base from the side. The
KZ300 base fits on top of this accessory.
Specifications
Dimensions
Diameter
107 mm
Height
25 mm
Ordering Information
S300
S700
The S700 is a base accessory designed for use with the KZ700 series detector bases.
It allows for a surface mount conduit and cable to enter the base from the side. The
KZ700 series base fits on top of this accessory.
Specifications
Dimensions
Diameter
95 mm
Height
30 mm
Ordering Information
S700
700 SERIES
DP721I
700 series
The smoke detector continually monitors its own sensitivity and operational status.
Once a day, it performs a full diagnostic test which includes dynamically testing the
sensing chamber and internal electronics.
Specifications
8.5 - 33 V dc FWR
Operating voltage
Current consumption
Quiescent at 24 V dc
In alarm at 24 V dc
60 mA
White LED (red alarm)
Yellow LED
30 mA
2 A @ 30 V dc;1 A @ 120 V ac
0 - 95%; Non-condensing
IP 43
10%/m (+1.6%, -3.3%)
2,5 V max
1 sec
10 cm , H = 5 cm
Alarm indication
Fault indication
Remote alarm output
RY contact rating
Humidity
IP rating
Sensitivity
Reset voltage
Reset time
Dimensions
Ordering Information
DP721I
DP721R
DB702
EN 54 approved
VDS certified
Photoelectric smoke and heat detector head with remote alarmLED output
700 series
Fitted with a field-exchangeable optical block. The smoke detector continually
monitors its own sensitivity and operational status. Once a day, it performs a full
diagnostic test which includes dynamically testing the sensing chamber and internal
electronics.
Specifications
8.5 - 33 V dc FWR
Operating voltage
Current consumption
Quiescent at 24 V dc
In alarm at 24 V dc
60 mA
White LED (red alarm)
Yellow LED
30 mA
2 A @ 30 V dc;1 A @ 120 V ac
0 - 95%; Non-condensing
IP 43
10%/m (+1.6%, -3.3%)
2,5 V max
1 sec
10 cm , H = 5 cm
Alarm indication
Fault indication
Remote alarm output
RY contact rating
Humidity
IP rating
Sensitivity
Reset voltage
Reset time
Dimensions
Ordering Information
DP721T
DP721RT
DP721RTA
DB702
EN 54 approved
VDS certified
DP721T
DT713-5
700 series
The smoke detector continually monitors its own sensitivity and operational status.
Once a day, it performs a full diagnostic test which includes dynamically testing the
sensing chamber and internal electronics.
Specifications
8.5 - 33 V dc FWR
Operating voltage
Current consumption
Quiescent at 24 V dc
In alarm at 24 V dc
60 mA
Red LED
Yellow LED
30 mA
2 A @ 30 V dc;1 A @ 120 V ac
0 - 95%; Non-condensing
IP 43
Alarm indication
Fault indication
Remote alarm output
RY contact rating
Humidity
IP rating
Heat specification
Max.
57 C 1.5 C
R.O.R.
Sensitivity
2,5 V max
1 sec
10 cm , H = 5 cm
Reset voltage
Reset time
Dimensions
Ordering Information
DT713-5
DT713-5R
DB702
EN 54 approved
VDS certified
DT713-7
700 series
The smoke detector continually monitors its own sensitivity and operational status.
Once a day, it performs a full diagnostic test which includes dynamically testing the
sensing chamber and internal electronics.
Specifications
8.5 - 33 V dc FWR
Operating voltage
Current consumption
Quiescent at 24 V dc
In alarm at 24 V dc
60 mA
Red LED
Yellow LED
30 mA
2 A @ 30 V dc;1 A @ 120 V ac
0 - 95%; Non-condensing
IP 43
Alarm indication
Fault indication
Remote alarm output
RY contact rating
Humidity
IP rating
Heat specification
Max.
70 C 1.5 C
R.O.R.
Reset voltage
Reset time
Dimensions
Ordering Information
DT713-7
DB702
EN 54 approved
VDS certified
DB702
700 series
Detector base for 700 series detectors
Ordering Information
DB702
DB702U
EN 54 approved
VDS certified
650 SERIES
DI650
650 series
This elegant slim-line ionisation detector offers high performance and wide operating
voltage
Specifications
42
Diameter
100
50
Diameter
100
9 - 33 V dc
Supply voltage
28 A
Quiescent Current at 24 V (typical)
LED
Alarm indication
Normal operating temp. range (no icing) -20 to + 60C
0-95% RH
Humidity (no condensation)
10m/s
Max. wind
17 mA
Remote alarm output current
43
IP Rating
Ordering Information
DI650
DI651
DB860
Polarity insensitive
Common base
EN 54 approved
DP652
650 series
This elegant slim-line optical sensor provides high performance and wide operating
range.
Specifications
42
Diameter
100
50
Diameter
100
9 - 33 V dc
Supply voltage
40 A
Quiescent Current at 24 V (typical)
LED
Alarm indication
Normal operating temp. range (no icing) -20 to + 60C
0-95% RH
Humidity (no condensation)
Not affected
Max. wind
17 mA
Remote alarm output current
43
IP Rating
Ordering Information
DP652
DB860
Polarity insensitive
Common base
EN 54 approved
DT654
650 series
This elegant slim-line heat sensor has a wide operating temperature and is available
in four ranges
Specifications
42
Diameter
100
50
Diameter
100
9 - 33 V dc
Supply voltage
45 A
Quiescent Current at 24 V (typical)
LED
Alarm indication
Normal operating temp. range (no icing) -20 to + 60C
0-95% RH
Humidity (no condensation)
Not affected
Max. wind
17 mA
Remote alarm output current
54
IP Rating
Ordering Information
DT654
DT655
DT656
DT657
DB860
Polarity insensitive
Common base
EN 54 approved
DB860
Standard Base
650 series
The base has been designed to enable detectors to be plugged in without any need for
force - particularly useful when fitting to suspended ceilings.
Ordering Information
DB860
Standard Base
Polarity insensitive
Common base
EN 54 approved
DB861
Ordering Information
DB861
DB806
An inexpensive and versatile accessory for surface mounting 860 and 950 series
bases
Ordering Information
DB806
DB650
650 series
The relay base provides a volt-free contact for use in 4 wire control systems, and
other applications
Ordering Information
DB650
DB650
1500 SERIES
DI1552
Ionisation Sensor
22 to 38 VDC
Operating voltage
Current consumption
Quiescent @ 38 VDC
200 A
In Alarm
< 11 mA
Storage Temperature
-10 to +70 C
Operating Temperature
-10 to +60 C
Humidity (non-condensing)
0-95%
IP rating
IP42
0.33 0.04 Ci Am 241
45 x 99 mm
Radioactive Source
Dimensions (h x )
Ordering Information
DI1552
Ionisation Sensor
SMD technology
EN54 Approved
DP1561
22 to 38 VDC
Operating voltage
Current consumption
Quiescent @ 38 VDC
350 A
In Alarm
< 11 mA
Red
Available
Storage Temperature
-10 to +70 C
Operating Temperature
-10 to +60 C
Humidity (non-condensing)
0-95%
IP rating
IP42
NA
45 x 99 mm
Radioactive Source
Dimensions (h x )
Ordering Information
DP1561
SMD technology
EN54 Approved
DP1551T
22 to 38 VDC
Operating voltage
Current consumption
Quiescent @ 38 VDC
350 A
In Alarm
< 5 mA
Red
Available
Storage Temperature
-10 to +70 C
Operating Temperature
-10 to +70 C
Humidity (non-condensing)
0-95%
IP rating
IP42
NA
51 x 99 mm
Radioactive Source
Dimensions (h x )
Ordering Information
DP1551T
SMD technology
EN54 Approved
DT1553
Heat Sensor
22 to 38 VDC
Operating voltage
Current consumption
Quiescent @ 38 VDC
250 A
In Alarm
< 11 mA
Storage Temperature
-10 to +80 C
Operating Temperature
-10 to +70 C
Humidity (non-condensing)
0-95%
IP rating
IP42
NA
45 x 99 mm
Radioactive Source
Dimensions (h x )
Ordering Information
DT1553
Heat Sensor
SMD technology
EN54 Approved
PG700
The PG700 is a handheld device programmer and tester for the KL700A/Dx1500 series
detectors. It is battery operated and allows the installer to perform installation tasks
(such as device addressing) and maintenance tasks (such as device clibration) in the
field without external assistance.
Specifications
2 x 9 V batteries
Supply
Ordering Information
PG700
Easy to use
Battery operated
- KL731A Calibration
KZ705I
The KZ705I is a detector base with built in isolator for use with the KL700A/Dx1500
series detectors from GE-Interlogix. The isolator protects the loop from short circuit
conditions. A LED on the side of the base indicates the status of the isolator.
Specifications
100 x 29 mm
17 - 34 V
50 A
6 mA
140 MOhm
Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
@ 5 mA
Environmental Characteristics
Operating Temperature
-10 to 70 C
Storage Temperature
-10 to 70 C
95 % (non-cond.)
Ordering Information
KZ705I
Polarity sensitive
Built in isolator
KZ705AS
The KZ705AS is a detector base with built in analogue addressable sounder for use
with the KL700A/Dx1500 series detectors from GE-Interlogix. The sounder has its own
address on the fire panel loop and works independent of the detector. It is fully
controlled from the fire panel.
Specifications
120 x 58 mm
22 - 38 V
300 A Quiescent
Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
1 KHz
Sounder Frequency
Sound Output
@ 3 mA
85 dBA
@ 5 mA
95 dBA
Environmental Characteristics
Operating Temperature
-10 to 70 C
Storage Temperature
-10 to 70 C
95 % (non-cond.)
IP Rating
IP21c
Ordering Information
KZ705AS
Polarity sensitive
Built in sounder
KZ705IAS
The KZ705IAS is a detector base with built in analogue addressable sounder and
isolator for use with the KL700A/Dx1500 series detectors from GE-Interlogix. The
sounder has its own address on the fire panel loop and works independent of the
detector. It is fully controlled from the fire panel. The isolator protects the loop from
short circuit conditions.
Specifications
120 x 58 mm
22 - 38 V
350 A Quiescent
6 mA
140 MOhm
1 KHz
Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
85 dBA
@ 5 mA
95 dBA
Environmental Characteristics
Operating Temperature
-10 to 70 C
Storage Temperature
-10 to 70 C
Polarity sensitive
95 % (non-cond.)
IP21c
Built in sounder
Built in isolator
Ordering Information
KZ705IAS
KAL410
Allows the connection of one conventional zone to the analogue fire system loop. This
zone is constantly monitored. Up to 20 conventional devices may be connected to this
zone.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
90 A
Quiescent @ 35 V
105 A
Alarm
< 3 mA
200 A + equip
< 85 mA
4.7 kOhm
NA
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Ordering Information
KAL410
Surface mount
Externally powered
Aesthetically pleasing
117 x 80 x 44 mm
Dimensions (l x w x h)
- Isolator Modules
- Output Units
- Retention Units
KAL414/4
Allows the connection of four conventional zones to the analogue fire system loop.
These zones are constantly monitored. Up to 20 conventional devices may be
connected to any zone.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
< 5 mA
200 A + equip
< 360 mA
4.7 kOhm
NA
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Ordering Information
KAL414/4
Surface mount
Externally powered
Aesthetically pleasing
163 x 107 x 36 mm
Dimensions (l x w x h)
- Isolator Modules
- Output Units
- Retention Units
KAL426
The 400 Series modules consists of a complete range of interfaces developed for
input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix.
The KAL426 allows for the connection and control of one extinguishing area to the
addressable fire panel loop.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
210 A
Alarm
< 10 mA
120 mA
<1A
4.7 kOhm
2 A
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Aesthetically pleasing
Externally powered
Supervised I/O
Surface mount
Dimensions (l x w x h)
Ordering Information
KAL426
PK10TD-ING
PK10TP-ING
KR24B
SK07
PK10CD
PK10CP
- Isolator Modules
- Output Units
- Retention Units
KAL430
Provides for one potential free relay output for the fire system loop. Each relay allows
for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. The output may be
used to activate ventilation controls, warning signs, activation of other alarm devices
etc. during fire situations.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
70 A
Quiescent @ 35 V
100 A
Alarm
< 3.5 mA
22 mA
< 50 mA
NA
2A @ 250 VAC
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Externally powered
Surface mount
Aesthetically pleasing
Dimensions (l x w x h)
Ordering Information
KAL430
- Isolator Modules
- Output Units
- Retention Units
KAL434/4
Provides for four potential free relay outputs for the fire system loop. Each relay
allows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. The outputs
may be used to activate ventilation controls, warning signs, activation of other alarm
devices etc. during fire situations.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
10 mA
100 A
10 mA
NA
2A @ 250 VAC
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Externally powered
Surface mount
Aesthetically pleasing
Dimensions (l x w x h)
Ordering Information
KAL434/4
- Isolator Modules
- Output Units
- Retention Units
KAL440
Allows for the supervision of a single, 24 Volt powered output contact on the fire
system loop. This unit may be used to control for e.g. sounders in case of fire
conditions, but may also be used to switch any output considered crucial enough to
have the cable integrity between the unit and the switch point monitored.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
< 3.6 mA
23 mA
23 mA + equip
4.7 kOhm
1 A @ 250 VAC
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Externally powered
Surface mount
Aesthetically pleasing
Dimensions (l x w x h)
Ordering Information
KAL440
- Isolator Modules
- Output Units
- Retention Units
KAL450
The 400 Series modules consists of a complete range of interfaces developed for
input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix.
The KAL450 is an addressable manual call point for manual fire activation.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
90 A
Quiescent @ 35 V
120 A
Alarm
< 3.5 mA
NA
NA
NA
NA
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Ordering Information
KAL450
Loop powered
Aesthetically pleasing
87 x 87 x 20
Dimensions (l x w x h)
DM715
DM790
DM787
DM782
DM800
- Isolator Modules
- Output Units
- Retention Units
KAL460
Provides a remote input to the fire system loop. The input is constantly monitored and
its status communicated to the fire control panel. The input may be activated by
closing or opening a potential free contact, depending on the module configuration.
This module may be used to monitor any contact by showing its status through the
fire control panel e.g. the monitoring of pressure equipment and closure fire break
doors.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
< 10 mA
200 A
< 50 mA
NA
NA
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Dimensions (l x w x h)
Ordering Information
KAL460
Externally powered
Surface mount
Aesthetically pleasing
- Isolator Modules
- Output Units
- Retention Units
KAL470
Isolator Module
The 400 series modules consist of a complete range of interfaces developed for
input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix.
The KAL470 is an isolator module in this series that isolates the faulty zone on a fire
panel loop during short circuit conditions. The KAL470 does not use an address on the
loop.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
10 mA
NA
NA
NA
NA
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +50C
Dimensions (l x w x h)
Automatic reset
Surface mount
Ordering Information
KAL470
Isolator Module
- Output Units
- Retention Units
KAL490
Provides a remote input and a potential free voltage relay output to the fire system
loop. The input signal is constantly monitored and its status displayed on the control
panel, whilst the output is fail-to-safe. Auxiliary supply monitoring is also included.
The module is used to for e.g. control and monitor doors such as fire break doors. The
relay provides the door activation and the input monitors the door status.
Specifications
22-38 VDC
Supply voltage
Current consumption
Quiescent @ 24 V
110 A
Quiescent @ 35 V
135 A
Alarm
10 mA
200 A
< 50 mA
NA
1A @ 30 VAC/VDC
End-of-line resistor
Relay contact rating
Environmental
Storage temperature
-10 to +50C
Operating temperature
-10 to +70C
Dimensions (l x w x h)
Ordering Information
KAL490
Externally powered
Surface mount
Aesthetically pleasing
- Isolator Modules
- Output Units
- Retention Units
2000 SERIES
DP2051
Optical Sensor
2000 Series
Equipped with a field-exchangeable optical block and has full certification, this
optical sensor provides good looks as well as top features
Specifications
Operating Voltage
Current consumption at 24 V dc
17 - 28 V dc
Quiescent
< 150 A
Alarm
LED: 2 mA - 7-segment: 2 mA
White LED (red alarm)
Not provided
0 - 95% non condensing
IP43
-
Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height
5 cm
Diameter
10 cm
Ordering Information
DP2051
DB2001
DB2016
Optical Sensor
Standard Base 10 cm, 2 Terminals
Isolating base
Polarity insensitive
Isolator base
EN54 approved
VdS approved
DP2061
2000 Series
Equipped with a field-exchangeable optical block and has full certification, this
optical sensor provides good looks as well as alarm and fault LEDs and remote output
Specifications
Operating voltage
Current consumption at 24 V dc
17 - 28 V dc
Quiescent
< 150 A
Alarm
5 cm
Diameter
10 cm
Ordering Information
DP2061
DB2002
DB2002U
DB2016
Polarity insensitive
Isolator base
EN54 approved
VdS approved
DP2071
2000 Series
Equipped with a field-exchangeable optical block and with full certification, this
optical sensor provides good looks as well as top features. Fitted with an exclusive
7-segment display, the sensor provides comprehensive information. In addition to
alarm signalling, information such as Fault, Pre-alarm, Maintenance Alarm (Clean
me), Disabled Sensor, Sensor in Test, Error (double address, wrong sensor type) and
Sensor Polled is provided.
Specifications
Operating voltage
Current consumption at 24 V dc
17 - 28 V dc
Quiescent
< 150 A
Alarm
LED: 2 mA - 7-segment: 2 mA
White LED (red alarm)
4 mA
0 - 95% non condensing
IP43
-
Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height
5 cm
Diameter
10 cm
Ordering Information
DP2071
DB2002
DB2002U
DB2016
7-segment display
Polarity insensitive
DT2053
Heat Sensor
2000 series
Fully certified, this heat sensor provides good looks as well as top features.
Specifications
Operating voltage
Current consumption at 24 V dc
17 - 28 V dc
Quiescent
< 150 A
Alarm
LED: 2 mA - 7-segment: 2 mA
Red LED
Not provided
0 - 95% non condensing
IP43
-
Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height
5 cm
Diameter
10 cm
Ordering Information
l
DT2053
DB2001
DB2016
VDS approved
Heat Sensor
Standard Base 10 cm, 2 Terminals
Isolating base
DT2063
2000 Series
Fully certified, this heat sensor provides good looks as well as top features. Dual
LED's indicate both alarm and fault. A remote output is also provided.
Specifications
Operating voltage
Current consumption at 24 V dc
17 - 28 V dc
Quiescent
< 150 A
Alarm
LED: 2 mA - 7-segment: 2 mA
Red LED
4 mA
0 - 95% non condensing
IP43
-
Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height
5 cm
Diameter
10 cm
Ordering Information
DT2063
DB2002
DB2002U
DB2016
VDS approved
DT2073
2000 Series
Fitted with an exclusive 7-segment display, this detector provides comprehensive, on
the spot information. In addition to alarm signalling, information such as Fault,
Pre-alarm, Maintenance Alarm (Clean me), Disabled Sensor, Sensor in Test, Error
(double address, wrong sensor type) and Sensor Polled is provided.
Specifications
Operating voltage
Current consumption at 24 V dc
17 - 28 V dc
Quiescent
< 150 A
Alarm
LED: 2 mA - 7-segment: 2 mA
Red LED
4 mA
0 - 95% non condensing
IP43
-
Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height
5 cm
Diameter
10 cm
Ordering Information
DT2073
DB2002
DB2002U
DB2016
VDS approved
DB2001
2000 series
2 terminal base for DP2051 and DT2053
Ordering Information
DB2001
VDS approved
DB2002
2000 series
A four terminal base for all 2000 series detectors
Ordering Information
DB2002
DB2002U
VDS approved
DB2016
Isolating base
2000 series
The DB2016 isolator base senses and isolates short circuit faults. A yellow LED
indicates a short circuit condition. The detector in the base will still receive power in
the event of a single short circuit. If every detector is fitted with an isolator base
then no device will be lost in the event of a single short circuit.
Ordering Information
DB2016
Isolating base
VDS approved
IU2016
Loop Isolator
2000 series
The Aritech Loop Isolator is designed to prevent an entire communication loop from
being disabled in the event of a short circuit. The IU 2016 isolates that part of the
loop containing the short from the remainder of the circuit.
Specifications
Operating voltage
Total standby current
Isolated current
Average
< 1.6 mA
Transition pulse
< 36 mA (5 ms duration)
Operating temperature
Operating humidity range
Line resistance
-10 C to 70 C
0 - 95%; Non-condensing
Normal
0.55 Ohms
Isolated
Switching voltage
Normal to isolated
13.8 V dc
Isolated to normal
2.5 V dc
Switching time
Normal to isolated
< 5 ms
Isolated to normal
Ordering Information
IU2016
DB2003
Loop Isolator
Base for the IU2016 isolator
Ordering Information
DB2003
DB2003
DM2000
2000 series
The DM 2000 is a break glass design call point with a high strength plastic housing.
The LED indicator provides visual confirmation of alarm initiation. The test key
(included with each unit) facilitates functional testing of the call point.
Specifications
17 - 28 V, @ comm.loop terminals
4 - 9 V dc
< 250 A
2.5 mA maximum
-10 C to 70 C
0 - 95%; Non-condensing
Operating voltage
Voltage modulation
Standby current
LED indicator current
Operating temperature
Operating humidity
Dimensions (L x W x H)
Flush mount
87 x 87 x 24 mm
Surface mount
87 x 87 x 56 mm
Ordering Information
DM2000
DM2000Y
DM2000B
DM711
DM715
Fast response
DM2000E
2000 series
The DM 2000E is a break glass design call point with a high strength plastic housing
and IP67 waterproof. The LED indicator provides visual confirmation of alarm
initiation. The test key (included with each unit) facilitates functional testing of the
call point.
Specifications
17 - 28 V, @ comm.loop terminals
4 - 9 V dc
< 250 A
2.5 mA maximum
-10 C to 70 C
0 - 95%; Non-condensing
Operating voltage
Voltage modulation
Standby current
LED indicator current
Operating temperature
Operating humidity
Dimensions (L x W x H)
Flush mount
87 x 87 x 24 mm
Surface mount
87 x 87 x 56 mm
Ordering Information
DM2000E
DM711
DM715
Fast response
IO2014
2000 series IO
The Aritech range of loop powered Input/Output Modules are designed to provide
unlimited applications to input monitoring and output switching in 2000 Series
Analogue Addressable Fire Detection Systems.
The 2000 Series of I/O Modules combined with the powerful features of the FP 2000
Fire Panels gives the user total versatility.
Specifications
Operating voltage
Total standby current
Typical standby current
Operating temperature
Operating humidity range
Outputs
Inputs
100 K resistor in series with switch
EOL resistor
17 - 28 V
< 250 A
< 200 A
-10C to 70C
0 - 95%; Non-condensing
2 A max. at 30 V dc
States
Quiescent (switch open)
Switch closed
Open circuit
Short circuit
Quiescent (switch open)
Not valid
Open circuit
Switch closed
150 K, 1/4W, 5%
Ordering Information
IO2014
IO2031
IO2032
IO2034
Supervised inputs
Loop powered
IU2050
2000 series
The Aritech Analogue Addressable Single Input Module is designed for use with the FP
2000 Fire Panel to monitor normally open or normally closed
contacts. It can typically be connected to conventional Manual Call Points, Pull
Stations or Door Monitors and will report actuation within 1 second
depending on the programming of the fire panel.
Specifications
Operating voltage
Voltage modulation
Standby current
Operating temperature
Operating humidity
EOL resistor
Ordering Information
IU2050
Loop Powered
Supervised Input
IU2055
2000 series
The IU 2055 two-wire zone monitor is designed to provide an interface between
conventional smoke detectors and the analogue addressable FP 2000 fire panel. The
IU 2055 enables the FP 2000 panel to monitor the presence and operation of up to 30
detectors
Specifications
Operating voltage
Total standby current
Maximum alarm current
Maximum zone load current
Maximum zone capacitance
Maximum zone line length
Operating temperature
Operating humidity range
End of line resistor value
Zone impedances @ 24 V
Short circuit
<100 Ohms
Fire
Quiescent
Open
> 15 K
Ordering Information
IU2055
Loop powered
GBX2000
Galvanic barrier
2000 series
A Galvanic barrier used with IU2055 zone monitor unit in intrinsic safe applications
Ordering Information
GBX2000
Galvanic barrier
IU2080
2000 series
The Aritech Indicating Circuit Controller is designed for efficient, addressable control
of sounders, bells and strobes in a fire detection system. The 3 A of output power
available from the IU 2080 assures meeting all requirements for signaling devices on
a fire alarm system.
Specifications
Operating voltage
Total standby current
Maximum alarm current
Operating temperature
Operating humidity range
Circuit impedance at 24 V
Short circuit
<3.3 K
Quiescent
3.3 K - 13 K
Open circuit
<13 K
24 V; <20.4 V
<11 mA @ 24 V dc
<72 mA @ 24 V dc (plus output circuit load current from
ext. power supply)
2.2 V dc, inverted
24 V dc
3A
10 K, 1/4W, 5%
Ordering Information
IU2080
Programmable output
2000 series
The FD 2705R and FD 2710R provides an integral, loop powered analogue
addressable reflective beam detector up to 100m distance. It operates with 2000
series protocol with the FP1200 / 2000 Fire panels
Specifications
10.2 - 30 V dc
Supply voltage
Range
FD 2705R:
5 - 50 meter
FD2710R:
50-100 meter
7.5 meter
Lateral detection
Current consumption:
quiescent
less than 4 ma
alarm
less than 25 ma
880 nm
-30C to 55 C
210 x 130 x 120 mm
IP50
Flame retardent ABS
Gray-black
Ordering Information
FD2705R
FD2710R
FD2705R
AS2015
2000 series
The AS2015 is a 2000 series addressable loop powered sounder for the FP1200 and
FP2000 range of fire panels. The unit has a built in isolator and can be synchronized.
Specifications
17-39 VDC
Operating voltage
Supply current
not activated
240A
activated
3mA
100 dB(A)
990 Hz
990 Hz, On Off @ 1 Hz
990 Hz / 650 Hz @ 1 Hz
Ordering Information
AS2015
AS2015W
Loop powered
Low current
Built in isolators
3 tones
950 SERIES
DI950
950 series
This elegant slim-line ionisation sensor provides high-performance smoke detection
Specifications
17-28
Supply voltage (V dc)
280 A
Quiescent current
Red LED
Alarm indication
2 mA
Alarm LED current
Normal operating temperature (no icing) -20 to +60 C
0-95 %
Rel. humidity (no condensation)
10 m/s
Max. wind (continuous)
50 x 100
Size of device in base (H x mm)
Ordering Information
DI950
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DP951
Optical sensor
950 series
This elegant slim-line optical sensor provides high performance analogue
addressable features
Specifications
17-28
Supply voltage (V dc)
340 A
Quiescent current
Clear LED (red in alarm)
Alarm indication
4 mA
Alarm LED current
Normal operating temperature (no icing) -20 to +60 C
0-95 %
Rel. humidity (no condensation)
Not affected
Max. wind (continuous)
50 x 100
Size of device in base (H x mm)
Ordering Information
DP951
DB950
Optical sensor
950 series standard base
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DT952
950 series
This elegant slim-line analogue addressable heat sensor provides exact temperature
information to the fire panel.
Specifications
17-28
Supply voltage (V dc)
250 A
Quiescent current
Red LED
Alarm indication
2 mA
Alarm LED current
Normal operating temperature (no icing) -20 to +60 C
0-95 %
Rel. humidity (no condensation)
Not affected in fixed temp. use
Max. wind (continuous)
50 x 100
Size of device in base (H x mm)
Ordering Information
DT952
DB950
950 series
A manual call point operating with 950 series protocol.
Ordering Information
DM960
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DM960
DI970
970 series
An intrinsic safe ionisation detector, when used with the PT971/2 protocol simulator
and GBX70 barrier
Ordering Information
DI970
PT971
PT972
GBX70
DB970
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DP971
970 series
An intrinsic safe optical detector, when used with the PT971/2 protocol translator and
GBX70 barrier
Ordering Information
DP971
PT971
PT972
GBX70
DB970
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DT972
970 series
An intrinsic safe heat detector, when used with the PT971/2 protocol translator and
GBX70 barrier
Ordering Information
DT972
PT971
PT972
GBX70
DB970
970 series
An intrinsic safe manual call point, when used with the PT971/2 protocol translator
and GBX70 barrier.
Ordering Information
DM970
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DM970
PT971
970 series
A protocol translator for the 970 series analogue addressable intrinsic safe sensors.
This must be used with the GBX70 barrier
Ordering Information
PT971
PT972
Ordering Information
GBX70
GBX70
II950
950 series
This unit is designed to monitor the state of one or more single pole switches
connected on a single pair of cables.
Specifications
14-28 Vdc
Supply voltage
Current consumption
Quiescent (20kOhm)
1 mA
Alarm
Led /relay on
3.5 mA
Switch on surge
3 mA
9-11 Vdc
-20/+70C
0-95%
IP54
Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection
Ordering Information
II950
II950I
l
l
Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller
Aesthetically pleasing
II952
950 series
This unit is designed to monitor the state of one or more single pole switches
connected on a single pair of cables. The circuit will report open and short-circuit
faults.
Specifications
14-28 Vdc
Supply voltage
Current consumption
Quiescent (20kOhm)
730A
Alarm
Led /relay on
5.6 mA
Switch on surge
2.5 mA
9-11 Vdc
-20/+70C
0-95%
IP54
Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection
Ordering Information
II952
II953
Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller
Aesthetically pleasing
II955
950 series
The zone monitor powers and controls the operation of a zone of conventional
detectors.
Specifications
14-28 Vdc
Supply voltage
Current consumption
Quiescent (20kOhm)
4 mA
Alarm
11-19 mA
Led /relay on
Switch on surge
2.8 mA
-20/+70C
0-95%
IP54
Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection
Ordering Information
II955
l
l
Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller
Aesthetically pleasing
IO950
950 series
This unit provides a loop-powered relay output, a monitored input and an
un-monitored opto-coupled input. It can report fault, switch open and switch closed
condition. It uses the standard housing.
Specifications
14-28 Vdc
Supply voltage
Current consumption
Quiescent (20kOhm)
1.2 mA
Alarm
Led /relay on
6 mA
Switch on surge
3.5 mA
9-11 Vdc
1A@30 Vac/dc
-20/+70C
0-95%
IP54
Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection
Ordering Information
IO950
Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller
Aesthetically pleasing
IO955
950 series
This unit provides a loop-powered relay output
Specifications
14-28 Vdc
Supply voltage
Current consumption
Quiescent (20kOhm)
720A
Alarm
Led /relay on
3.3 mA
Switch on surge
3 mA
1A@30 Vac/dc
-20/+70C
0-95%
IP54
Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection
Ordering Information
IO955
Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller
Aesthetically pleasing
IO956
950 series
This unit is designed to control a zone of sounders powered by an external DC supply.
Specifications
14-28 Vdc
Supply voltage
Current consumption
Quiescent (20kOhm)
1.9 mA
Alarm
Led /relay on
1.7 mA
Switch on surge
2.6 mA
9-11 Vdc
-20/+70C
0-95%
IP54
Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection
Ordering Information
l
IO956
Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller
Aesthetically pleasing
Ordering Information
IU950
IU950
AS950
950 Series
Designed to operate with the 950 series analogue sensors and monitors, the AS950
loop sounders are addressed and utilise the same protocol using a very low current.
Specifications
14 - 28 V dc
Supply voltage
Current consumption
Quiescent
140 A at 24 V dc
Switch on surge
Operated at 85 dBA
3 mA +/- 0.25 mA
Operated at 92 dBA
8 mA +/- 0.25 mA
500 - 550 Hz (continuous mode)
IP43
-20 to 60 C
115 x 25 mm (sounder only)
115 x 33 mm (sounder with cap)
140 g (sounder only)
145 g (sounder with cap)
Drive frequency
Ingress protection
Operating temperature
Dimension (dia. x depth)
Weight
Ordering Information
AS950
AS950I
AS950W
Loop powered
AS955
950 Series
Designed to operate with the 950 series analogue sensors and monitors, the AS955
high output loop sounders are addressed and utilise the same protocol using a very
low current.
Specifications
14 - 28 V dc
Supply voltage
Current consumption
Quiescent
140 A at 24 V dc
Switch on surge
Operated
Drive frequency
Ingress protection
Operating temperature
Sound output
Ordering Information
AS955
Loop powered
FD950
950 Series
A 950 series loop-powered beam detector with a range of up to 100m long and 15m
wide.
Ordering Information
FD950
Loop-powered
Drift compensation
Remote interface
Simple wiring
Simple alignment
DB950
950 series
A unique, patented addressing method provides simple, user-friendly and accurate
identification of monitor location whereby a coded card, inserted in the base, is read
by any monitor as it is plugged in.
Ordering Information
DB950
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DB951
950 series
The isolating base senses and isolates short-circuit faults on 950 series loops and
spurs. Up to 20 devices may be placed between any two isolator bases.
Ordering Information
DB951
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DB961
The isolating base senses and isolates short circuit faults on 950 series loops and
spurs. Up to 20 devices may be placed between any two isolator bases.
Ordering Information
DB961
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
DB970
Ordering Information
DB970
Aesthetic design
EN 54,BOSEC,VdS,CNBOP approved
950 series
Precoded Xpert address cards for use in DB9xx bases
Ordering Information
IU980
IU981
IU982
IU983
IU984
IU985
IU986
IU980
FP202
Supply Voltage
Mains fuse (Type 5x20 mm)
Total consumption
< 20 W
24 VDC
Batteries
Recommended batteries
Fuse Rating
1A
< 100 mA
Zone
Maximum Load
72 mA
20
Ouput voltage
22 to 28 VDC
End-of-line resitance
4k7 Ohm
100 Ohm, 2 W
Outputs
Microprocessor controlled
Fire alarm
Multilingual keyboard
2 Access levels
Environmental
Working temperature
+5 to +40C
Storage temperature
-10 to +70C
Relative humidity
95 % (non-condencing)
Physical Characteristics
Size (w x h x d)
3 kg
Low maintenance
Ordering Information
FP202
FP204
Supply Voltage
Mains fuse (Type 5x20 mm)
Total consumption
< 20 W
24 VDC
Batteries
Recommended batteries
Fuse Rating
1A
< 100 mA
Zone
Maximum Load
72 mA
20
Ouput voltage
22 to 28 VDC
End-of-line resitance
4k7 Ohm
100 Ohm, 2 W
Outputs
Microprocessor controlled
Fire alarm
Multilingual keyboard
2 Access levels
Environmental
Working temperature
+5 to +40C
Storage temperature
-10 to +70C
Relative humidity
95 % (non-condencing)
Physical Characteristics
Size (w x h x d)
3 kg
Low maintenance
Ordering Information
FP204
FP206
Supply Voltage
Mains fuse (Type 5x20 mm)
Total consumption
< 20 W
24 VDC
Batteries
Recommended batteries
Fuse Rating
1A
< 100 mA
Zone
Maximum Load
72 mA
20
Ouput voltage
22 to 28 VDC
End-of-line resitance
4k7 Ohm
100 Ohm, 2 W
Outputs
Microprocessor controlled
Fire alarm
Multilingual keyboard
2 Access levels
Environmental
Working temperature
+5 to +40C
Storage temperature
-10 to +70C
Relative humidity
95 % (non-condencing)
Physical Characteristics
Size (w x h x d)
3 kg
Low maintenance
Ordering Information
FP206
FP402
The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications
Capacity
2 x 2.3 Ah
Fuse rating
2A
Zone
Maximum load
94 mA
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Microprocessor controlled
From 2 up to 16 zones
2 Access levels
External watchdog
1 A @ 30 VDC
Maximum load
NA
Fuse rating
NA
Auxilliary Output
24 VDC Resetable Output
250 mA
Maximum Load
100 mA
Reset time
3s
Environment
Working temperature
-5C to +40C
IP30
Physical Characteristics
Size (mm)
3.6 kg
Ordering Information
FP402
FP404
FP408
The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications
Capacity
2 x 7.5 Ah
Fuse rating
5A
Zone
Maximum load
94 mA
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Microprocessor controlled
From 2 up to 16 zones
2 Access levels
External watchdog
1 A @ 30 VDC
Maximum load
NA
Fuse rating
NA
Auxilliary Output
24 VDC Resetable Output
250 mA
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5C to +40C
IP30
Physical Characteristics
Size (mm)
6.2 kg
Ordering Information
FP408
FP412
The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications
Capacity
2 x 7.5 Ah
Fuse rating
5A
Zone
Maximum load
94 mA
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Microprocessor controlled
From 2 up to 16 zones
2 Access levels
External watchdog
1 A @ 30 VDC
Maximum load
NA
Fuse rating
NA
Auxilliary Output
24 VDC Resetable Output
250 mA
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5C to +40C
IP30
Physical Characteristics
Size (mm)
6.2 kg
Ordering Information
FP412
FP416
The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications
Capacity
2 x 7.5 Ah
Fuse rating
5A
Zone
Maximum load
94 mA
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Microprocessor controlled
From 2 up to 16 zones
2 Access levels
External watchdog
1 A @ 30 VDC
Maximum load
NA
Fuse rating
NA
Auxilliary Output
24 VDC Resetable Output
250 mA
Maximum load
100 mA
Reset time
3s
Environment
Working temperature
-5C to +40C
IP30
Physical Characteristics
Size (mm)
6.2 kg
Ordering Information
FP416
RB404
The RB404 relay expander module has voltage-free 4 relays. The unit allows for a
relay for each detection zone or for programming the activation of different relays
depending on the status of one or more zones. It is used on the GE-Interlogix
NK700/FP400 conventional fire panel range.
Specifications
Relay Rating
Voltage
230 VDC
Current
2A
0 to 9 minutes
Delay setting
Ordering Information
RB404
l
l
SB404
The SB404 module has 4 relays that provide 4 of 24 VDC supervised outputs. These
may be configured to power sounders or as standard 24 VDC supervised outputs for
other devices.
Specifications
24 VDC
0 to 9 minutes
Aux. Supply
Delay Setting
Ordering Information
SB404
l
l
4 Supervised relays
Up to 4 modules may be housed inside the fire panel
cabinet
Conventional fire detection and extinguishing control panel with 3 zones including 1 extinguishing zone
FEC403
The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications
Capacity
2 x 7 Ah
Fuse rating
2A
Zone
Maximum load
94 mA
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Microprocessor controlled
EN54 compliant
2 Access levels
External watchdog
1 A @ 30 VDC
Maximum load
350 mA
Fuse rating
1A
Auxilliary Output
24 VDC Resetable Output
250 mA
Maximum Load
100 mA
Reset time
3s
Environment
Working temperature
-5C to +40C
IP30
Physical Characteristics
Size (mm)
6.2 kg
Ordering Information
FEC403
FEC406
The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications
Capacity
2 x 7 Ah
Fuse rating
2A
Zone
Maximum load
94 mA
44 ohm
Sounders
Maximum load
250 mA
Delay
Selectable 0 - 9 min
Microprocessor controlled
EN54 compliant
2 Access levels
External watchdog
1 A @ 30 VDC
Maximum load
350 mA
Fuse rating
1A
Auxilliary Output
24 VDC Resetable Output
250 mA
Maximum Load
100 mA
Reset time
3s
Environment
Working temperature
-5C to +40C
IP30
Physical Characteristics
Size (mm)
6.2 kg
Ordering Information
FEC406
FP604
The FP 604 fire panel is designed using the latest technologies and is compatible
with most brands of conventional fire detectors. The FP 604 is a 4-zone panel which
is extendable up to 6 zones.
Specifications
Ordering Information
FP604
ZI602
RC606
Alarm verification
12 V dc auxiliary output
4 - 6 zones
Sirens output 12 or 24 V dc
Microprocessor based
EN 54 p2/4 approved
LPCB certified
ZI602
This board extends the FP604 from 4 zones to 6 zones. It also provides 6 outputs for
the 6 zones.
Ordering Information
ZI602
Ordering Information
RC606
RC606
FP708
FP700 series
A set of four conventional fire panels. The FP708 and FP708C are 8 zone
non-expandable fire panels. The FP740 and FP740C are 8 zone expandable to 40
zones. The FP708C and FP740C have an alarm counter. All panels can use the full
range of LON700 output boards.
Specifications
Ordering Information
FP708
FP708C
FP740
FP740C
Fully modular
Alarm verification
Approved BOSEC
Complies to EN 54 p2/p4
Modular up to 40 zones
Microprocessor based
FR708
FR700 series
The repeaters provide different solutions - 24 volt input and 230 volt input using the
PS700 power supply. The FR708 is 8 zones non expandable and the FR740 is 8 zones
expandable to 40 zones. The FR700 repeaters connect to the FP700 fire panel with
the LON 700 bus. The FR708V230 and FR740V230 include a card cage for LON board
expansion and have a PS700 power supply.
Ordering Information
FR708
FR708V230
FR740
FR740V230
Fully modular
Modular up to 40 zones
Microprocessor based
ZE708
FP700 series
This zone indicator extension board is used to expand the FP740 and FR740 front
panel indications.
Ordering Information
ZE708
FP700 series
An eight zone input expansion board for FP740 fire panels.
Ordering Information
ZI708
ZI708
FM740
Dimensions mm (L x W x D)
Weight
Operating temp C
Operating voltage Vdc
Current consumption
150x30x60
200 g
-5C - +40
19 - 30
max quiesent mA
30
40
Bus Connection
FP1200/FP2000 (with LON2000)
***
***
Bus Cable
Total number of repeaters
Cat 5
FP1200/FP2000
15
FP700
Ordering Information
FM740
LON700 series
A 24 way open collector board used in a LON700 system
Ordering Information
OCB724
OCB724
RB708
LON700 series
An eight way relay board used in LON700 systems
Ordering Information
RB708
LON700 series
Eight supervised outputs that can be used in LON700 systems
Ordering Information
SOB708
SOB708
FB708
LON700 series
The FB708 and FB740 'black boxes' allow for the distribution of LON700 input /
output units. When used with the NC700 or FM740, the FB7xx is connected to the
FP700 / FP2000 firepanels with the LON700 bus.
Ordering Information
FB708
FB740
NC700
Fully modular
Microprocessor based
NC700
LON700 series
An interface board to connect a LON bus from a fire panel to a FB7xx 'black box'
Ordering Information
NC700
FB708
FB740
LON700 series
This power supply can be used to extend the power output in LON700 systems. It is
standard in the FP700 and FR700V230 systems, as well the FB740 'black box'.
Ordering Information
PS700
PS700
FP1501
The FP1501 1 loop analogue addressable fire alarm control panel is the ideal solution
for small to medium-sized installations. Very powerful and cost-effective, it is
extremely simple to install and use due to is ergonomic, advanced design. The panel
is supplied in an elegant, high-quality, conveniently sized, heavy-duty enclosure. It
has a high-quality keyboard with audible metallic click and good travel.
Specifications
Supply Voltage
Current Consumption
Batteries
Capacity
2 x 12 V - 7 AH (SLA type)
Fuse Rating
3A
Charger Rating
Maximum Load
20 Display zones
Panel networking
Environment
Working Temperature
-5C to +40 C
Relative Humidity
0-95% non-condensing
IP Rating
IP30
Physical Characteristics
Size
Weight
Ordering Information
FP1501
FP1502
The FP1500 series analogue addressable fire alarm control panels is the ideal
solution for small to medium-sized installations. Very powerful and cost-effective,
they are extremely simple to install and use due to their ergonomic, advanced design.
Supply Voltage
Current Consumption
Batteries
Capacity
2 x 12 V - 7 AH (SLA type)
Fuse Rating
3A
Charger Rating
Maximum Load
20 Display zones
Panel networking
Environment
Working Temperature
-5C to +40 C
Relative Humidity
0-95% non-condensing
IP Rating
IP30
Physical Characteristics
Size
Weight
Ordering Information
FP1502
NC785
The NC785 RS485 expander allows for an easy upgrade to the KSA701/FP1500 series
analalogue addressable fire panels. Each module adds an additional industry
standard RS485 communication port to the panel. This port could be used for
communications with other network nodes in the fire panel network.
Specifications
Number of ports
Communications medium
Technical specifications
1
RS485
1200 m
Communication speed
9600 baud
Cable
Termination resistance
150 Ohm
Ordering Information
NC785
FR1500
The FP1500 Series analogue addressable fire alarm panels are the ideal solution for
small to medium-sized installations. Very powerful and cost-effective, they are easy
to install and use due to their ergonomic, advanced design. The FR1500 LCD repeater
is supplied in the same enclosure as the FP1500.
Specifications
Supply Voltage
AC Version
DC Version
24 VDC
Current Consumption
Battery Charger (AC Version only)
Capacity
2 x 12 V - 7 AH (SLA type)
Fuse Rating
3A
Charger Rating
Environment
Working Temperature
-5C to +40 C
Relative Humidity
0-95% non-condensing
IP Rating
IP30
Physical Characteristics
Size
Weight
20 Display zones
Panel networking
Communication Ports
Ordering Information
FR1500
MODGSM
The MODGSM modem may be used in KSA701/FP1500, KSA702 and KSA705 fire panel
from GE-Interlogix. It is ideal for use as a standard modem for making and receiving
calls from and to the fire panel, but may also be used for GSM messaging.
Specifications
900/1800 MHz
Data, SMS, Voice and Fax
GSM 07.07 and 07.05
GSM Band
Services
AT Commands
Output Power (max)
GSM900
2W
GSM1800
1W
5 to 32 V
Input Voltage
Current @ 5V
Avarage
330 mA
Peak
1.8 A
SIM Interface
Dimensions (h x w x d)
Weight
Environmental Temperature
3V / 5V
98 x 54 x 25 mm
130 g
Storage
- 25 C to + 70 C
Operating
- 20 C to + 55 C
Ordering Information
MODGSM
PCG-Graphic102
Hardware Requirements
Communication
Display
Hard Disk
Keyboard
Required
Pointing Device
Required
Printer
Processor
RAM
256 Mb or more
Removable Media
Software Requirements
Operating System
Ordering Information
PCG-Graphic102
PCG-Graphic105
Hardware Requirements
Communication
Display
Hard Disk
Keyboard
Required
Pointing Device
Required
Printer
Processor
RAM
256 Mb or more
Removable Media
Software Requirements
Operating System
Ordering Information
PCG-Graphic105
PCG-GraphicNW
Hardware Requirements
Communication
Display
Hard Disk
Keyboard
Required
Pointing Device
Required
Printer
Processor
RAM
256 Mb or more
Removable Media
Software Requirements
Operating System
Ordering Information
PCG-GraphicNW
FP1216EN
FP1216 series
A versatile, cost effective analogue addressable fire panel, 2 to 4 loops, giving
powerfull features
Specifications
Supply voltage
230 V ac (+10/-15%)
50 Hz
220 VA
0.2 A
1.6 A
4A
2A
7.5 kg
440 x 444 x 125
Ordering Information
FP1216EN
Soak test
Upload/download
EN 54 p2 & 4 approved
2 or 4 class A loops
FP2416
FP2000 Series
Specifications
190 - 270 V ac
40- 60 Hz
160 VA max.
21 - 27 V dc
Supply voltage 1
Supply voltage 2
Current consumption
600 mA
3.4 A
3A
4A
2A
11 kg
609 x 441 x 109
Ordering Information
FP2416
Graphic maintenance
Maintenance warning
Soak test
Floating background
Service switch
FP2432
FP2000 Series
Specifications
190 - 270 V ac
40- 60 Hz
160 VA max.
21 - 27 V dc
Supply voltage 1
Supply voltage 2
Current consumption
600 mA
3.4 A
3A
4A
2A
11 kg
609 x 441 x 109
Ordering Information
FP2432
Graphic maintenance
Maintenance warning
Soak test
Floating background
Service switch
FP2864
FP2000 series
Specifications
190 - 270 V ac
40 - 60 Hz
160 VA max.
21 - 27 V dc
Supply voltage 1
Supply voltage 2
Current consumption
1A
3A
3A
4A
2A
15 kg
804 x 441 x 109
Ordering Information
FP2864
Graphic maintenance
Maintenance warning
Soak test
Floating background
Service switch
FB2400
FP2000 series
The FB2400 / FB2800 'black box' system allows a cost-effective network of fire panels
to be interconnected to a global repeater
Specifications
190 - 270 V ac
40- 60 Hz
160 VA max.
21 - 27 V dc
Supply voltage 1
Supply voltage 2
Current consumption
500 mA
Quiescent @ 24 V dc (Fully equipped loop)
600 mA
Alarm current @ 24 V dc
3.4 A
Available auxiliary current in alarm
3A
Battery charger rating @ 27.5 V dc
4A
Total supply rating @ 27.5 V dc
2A
Relay rating @ 24 V dc
11 kg
Weight (no batteries)
609 x 441 x 109
Dimensions (mm H x W x D)
Ordering Information
FB2400
FB2800
Graphic maintenance
Maintenance warning
Soak test
Floating background
Service switch
LC2002
Current consumption
Quiescent @ 24 V dc (Fully equipped+loop)
150 mA (252 detectors)
Ordering Information
LC2002
Ordering Information
ZE2016
ZE2016
LON2000
Ordering Information
LON2000
Ordering Information
NC2011
NE2011
NC2011
NC2051
Ordering Information
NC2051
NE2051
Ordering Information
NE2011
NE2011
Ordering Information
NE2051
NE2051
FRL700
LCD repeater
Dimensions mm (L x W x D)
Weight
Operating temp C
Operating voltage Vdc
Current consumption
max quiesent mA
240x320x60
1.5 kg
-5C - +40
15 - 30
100
Bus Connection
FP1200/FP2000 (with LON2000)
Bus Cable
Total number of repeaters
***
Cat 5
FP1200/FP2000
15
FP700
***
Ordering Information
FRL700
FBP70006
FBP70005
FBP70007
FBP70001
LON2000
LCD repeater
Fire brigade panel Swedish (SS3654)
Fire brigade panel Norwegian (SS3654)
Fire brigade panel Danish (SS3654)
Fire brigade panel (NEN2535)
LON700 driver for FP1200 / FP2000
FR1200
LCD repeater
Supply voltage
230 V ac (+10/-15%)
50 Hz
50 VA
0.15 A
0.3 A
1A
2A
7.5 kg
365 x 444 x 111
Ordering Information
FR1200
LCD repeater
l
l
FR2000
Supply voltage
230 V ac (+10/-15%)
50 Hz
50 VA
0.15 A
0.3 A
1A
2A
7.5 kg
365 x 444 x 111
Ordering Information
FR2000
l
l
FR2032
Repeater/emulator 32 zones/panels
Ordering Information
FR2032
Repeater/emulator 32 zones/panels
l
l
24 Volt operation
Emulation functions
FR2064
Repeater/emulator 64 zones
Ordering Information
FR2064
Repeater/emulator 64 zones
l
l
Emulation function
24 volt operation
UN2011
Ordering Information
UN2011
230V operation
MOD2000
Modem kit
Ordering Information
MOD2000
Modem kit
MOD2000
Internal installation
PCC2000
486 66 MHz
12 Mb
VGA
20 MB
MS Mouse, etc.
Windows 95
1 x RS-232
1 parallel
Processor
RAM
Display adapter
Hard disk space
Pointing device
Graphical environment
Communications ports
Ordering Information
PCC2000
Menu driven
PCM2000
Processor
RAM
Display Adapter
Hard Disk Space
Pointing Device
Graphical Environment
Communications ports
Ordering Information
PCM2000
Data retrieval
Central station
History log
Address book
PCG-S
PCG Series
A total of 4 packages allow the graphic package to grow with the installation. The
basic version PCG-S operates with a single panel, while the PCG-N supports a
network. The PCG-CS allows for TCP/IP client server applications. Upgrades do not
require rework on the existing database, drawings, etc.
Specifications
Recommended
Pentium II 266 MHz (or better)
64 Mb (or more)
SVGA or better
200 MB
MS Mouse, Bus or P/S2
Windows NT
1 x RS-232 - Depending on drivers
1 x Parallel - Printer port (for key)
Item
Processor
RAM
Display adapter
Hard disk space
Pointing device
Graphical environment
Communication ports
Ordering Information
PCG-S
PCG-N
PCG-CS
PCG-C
Operator configurable
Event logs
Content
Conventional Fire Detectors
DI322I
DP331I
DT313I
KCT731
DB304
KZ705
KZ705D
EOL-ACT
KZ705R
S300
S700
DP721I
DP721T
DT713-5
DT713-7
DB702
DI650
DP652
DT654
DB860
DB861
DB806
DB650
Page : 5
Page : 6
Page : 7
Page : 8
Page : 9
Page : 9
Page : 10
Page : 11
Page : 11
Page : 12
Page : 12
Page : 15
Photoelectric smoke and heat detector head with remote alarmLED output
Page : 15
Page : 16
Page : 17
Page : 18
Page : 21
Page : 22
Page : 23
Standard Base
Page : 24
Page : 24
Page : 25
Page : 25
DI1552
DP1561
DP1551T
DT1553
PG700
KZ705I
KZ705AS
KZ705IAS
KAL410
KAL414/4
KAL426
KAL430
KAL434/4
KAL440
KAL450
KAL460
KAL470
KAL490
DP2051
DP2061
DP2071
DT2053
Ionisation Sensor
Page : 29
Page : 30
Page : 31
Heat Sensor
Page : 32
Page : 33
Page : 34
Page : 35
Page : 36
Page : 37
Page : 38
Page : 39
Page : 40
Page : 41
Page : 42
Page : 43
Page : 44
Isolator Module
Page : 45
Page : 46
Optical Sensor
Page : 49
Page : 50
Page : 51
Heat Sensor
Page : 52
DT2063
DT2073
DB2001
DB2002
DB2016
IU2016
DB2003
DM2000
DM2000E
IO2014
IU2050
IU2055
GBX2000
IU2080
FD2705R
AS2015
DI950
DP951
DT952
DM960
DI970
DP971
DT972
DM970
PT971
GBX70
II950
II952
II955
IO950
IO955
IO956
IU950
AS950
AS955
FD950
DB950
DB951
DB961
DB970
IU980
Page : 52
Page : 53
Page : 54
Page : 54
Isolating base
Page : 55
Loop Isolator
Page : 55
Page : 56
Page : 57
Page : 58
Page : 59
Page : 60
Page : 61
Galvanic barrier
Page : 61
Page : 62
Page : 63
Page : 64
Page : 67
Optical sensor
Page : 67
Page : 68
Page : 68
Page : 69
Page : 69
Page : 70
Page : 70
Page : 71
Page : 71
Page : 72
Page : 72
Page : 73
Page : 73
Page : 74
Page : 74
Page : 75
Page : 76
Page : 77
Page : 78
Page : 79
Page : 79
Page : 80
Page : 80
Page : 81
FP202
FP204
FP206
FP402
FP408
Page : 85
Page : 86
Page : 87
Page : 91
Page : 92
FP412
FP416
RB404
SB404
FEC403
FEC406
FP604
ZI602
RC606
FP708
FR708
ZE708
ZI708
FM740
OCB724
RB708
SOB708
FB708
NC700
PS700
Page : 93
Page : 94
Page : 95
Page : 96
Conventional fire detection and extinguishing control panel with 3 zones including 1 extinguishing zone
Page : 97
Page : 98
Page : 101
Page : 102
Page : 102
Page : 105
Page : 106
Page : 107
Page : 107
Page : 108
Page : 108
Page : 109
Page : 109
Page : 110
Page : 111
Page : 111
FP1501
Analogue addressable fire detection panel - 1 loop
FP1502
Analogue addressable fire detection panel - 2 loops
NC785
RS485 Expansion kit for KSA701/FP1500 fire panels
FR1500
Analogue addressable LCD Repeater/Emulator*
MODGSM
GSM Modem for Kilsen Fire Panels
PCG-Graphic102 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)
PCG-Graphic105 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)
PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)
FP1216EN
Analogue panel, 2- 4 loop, 16 zones
FP2416
Analogue adressable fire panel - 2 to 4 loops. 16 zones
FP2432
Analogue addressable panel - 2 to 4 loops, 16 to 32 zones
FP2864
Analogue addressable fire panel - 2 to 8 loops. 16 - 64 zones
FB2400
Analogue addressable fire panel - 2 to 4 loops, 'black box'
LC2002
2-loop extension board for FP1200 / FP2000 fire panels
ZE2016
16-zone LED extension fire and fault LED
LON2000
LON700 driver for FP1200 / FP2000
NC2011
ARCNET RS 485 network card with single, RS 485 interface
NC2051
ARCNET network card with single optical, interface board NE 2051
NE2011
RS 485 network extension board
NE2051
Fibre optic network extension board
FRL700
LCD repeater
FR1200
LCD repeater
FR2000
LCD repeater with emulator functions
FR2032
Repeater/emulator 32 zones/panels
FR2064
Repeater/emulator 64 zones
UN2011
ARCNET universal node
Page : 115
Page : 116
Page : 117
Page : 118
Page : 119
Page : 120
Page : 121
Page : 122
Page : 125
Page : 126
Page : 127
Page : 128
Page : 129
Page : 130
Page : 130
Page : 131
Page : 131
Page : 132
Page : 132
Page : 133
Page : 134
Page : 135
Page : 136
Page : 137
Page : 138
Page : 139
MOD2000
PCC2000
PCM2000
PCG-S
Modem kit
Page : 139
Page : 140
Page : 141
Page : 142