Professional Documents
Culture Documents
Omml 0424 11
Omml 0424 11
Omml 0424 11
Rev. : A
Page : 1/1
COMPONENT LITERATURE
EQUIPMENT DEFINITION
GE DEVICE
: 77FD-1 TO 3
DESIGNATION
SUPPLIER
: AI-TEK
TYPE
: 70085-1010-245
LITERATURE REFERENCE
OMML_0424_11_77FD-1T3_A_EN
Revision: A
Date: 05/2012
960-0117-001
REVISIONS
LTR
A
B
C
D
E
DESCRIPTION
DATE
APVD
6/4/08
4/3/09
9/15/09
JH
8/11/10
CSK
8/23/10
CSK
CSK
CSK
10
11
12
13
14
REGULATORY DOCUMENT
APPROVALS
16
17
CS Kalley
8/5/10
CHECKED
CSKalley
8/9/10
DSGN ENGR
CSKalley
8/9/10
QUAL ENGR
CEGerard
8/10/10
MFG ENGR
ERuman
8/9/10
18
19
20
21
22
23
24
25
26
27
28
29
DATE
PREPARED
EF-001-02-F1 REV A
15
TITLE:
DECLARATION OF CONFORMITY
SIZE
CODE IDENT.
NUMBER
A 1XP56
DWG. NO.
960-0117-001
CAD
SHEET 1 OF 2
CONTINUATION SHEET
SUPPLIERS DECLARATION OF CONFORMITY
(in accordance with ISO/IEC 17050-1)
NUMBER 960- 0117- 001
ISSUERS NAME & ADDDRESS: AI-TEK Instruments, LLC
152 Knotter Drive, Cheshire, CT 06410 USA
Telephone: (203)271-6000 FAX: (203)271-6200
OBJECT OF THE DECLARATION: Self generating variable reluctance speed sensors,
models: 70085-1010-245, -249, 392, -403, -405, -415, -416, & -429
The object of the declaration described above is in conformity with the requirements
of the following documents:
EN 60079-0:2006: Electrical apparatus for explosive gas atmospheresGeneral requirements
EN60079-15:2005: Electrical apparatus for potentially explosive atmospheres Type of Protection: n
ATEX Directive 94/9/EC
ADDITIONAL INFORMATION:
1. The flying leads shall be terminated in a suitable ATEX approved terminal enclosure
when terminated in a classified (Zoned) area.
2. These devices shall only be installed in applications where the operating
temperature is between -55oC and +220oC.
3. These sensors are considered to be inherently benign in the context of the EMC
Directive 2004/108/EC, Article 1(3).
4. These devices comply with the requirements of the above standards and the ATEX
directive 94/9/EC for use in a Category 3G area when installed in a non-incendive
field circuit per AI-TEK Installation Instruction 960-0112-001 (960-0113-001 for
70085-1010-429). The component will be marked in compliance with the
requirements:
II 3 G
Ex nA II X T2
-55qC Tamb 220C
Signed for and on behalf of:
AI-Tek Instruments, LLC
Cheshire, CT USA 3 August 2010
SIZE
EF-001-02-F1 REV A
CODE IDENT.
NUMBER
1XP56
DWG NO.:
960-0117-001
REV E
SHEET 2
960-0112-001
REVISIONS
LTR
D
E
F
G
DESCRIPTION
DATE
APVD
6/4/08
7/15/08
4/3/09
9/14/10
JH
CSK
CSK
CSK
10
11
12
13
14
REGULATORY DOCUMENT
APPROVALS
16
KAErasmus
5/29/08
CHECKED
JHamed
6/4/08
DSGN ENGR
JHamed
6/4/08
QUAL ENGR
CEGerard
6/5/08
MFG ENGR
PJulian
6/4/08
17
18
19
20
21
22
23
24
25
26
27
28
29
DATE
PREPARED
EF-001-02-F1 REV A
15
TITLE:
INSTALLATION INSTRUCTIONS
SPEED SENSORS
SIZE
CODE IDENT.
NUMBER
A 1XP56
DWG. NO.
960-0112-001
CAD
SHEET 1 OF 3
CONTINUATION SHEET
MONTH
JAN
FEB
MAR
APR
CODE
A
B
C
D
DATE CODE
MONTH
CODE
MAY
E
JUN
G
JUL
H
AUG
J
MONTH
SEPT
OCT
NOV
DEC
CODE
K
L
M
N
SIZE
EF-001-02-F1 REV A
CODE IDENT.
NUMBER
1XP56
DWG NO.:
960-0112-001
REV G
SHEET 2
CONTINUATION SHEET
STANDARD SENSOR INSTALLATION SEE FIGURE #1:
1. If a feeler gauge can be used, select the gauge with the proper thickness and place it over the
highest point on the target. Thread the sensor into the mounting bracket until it touches the
selected gauge, then tighten the locknut.
2. If a feeler gauge cannot be used, thread the sensor into the threaded hole finger tight against a
tooth or the largest diameter of the stationary target. Back the sensor out of contact until the
desired air gap is set, then tighten the locknut. A full CCW revolution results in an air gap of:
one divided by the number of threads per inch.
EXAMPLE: 5/8 -18 THREAD = 1/18 = .056.
SENSORS WITH INTERNAL PIPE THREADS FOR CONDUIT FITTINGS:
Install the conduit fitting into the sensor egress internal thread and finger tighten. While holding the
sensor hex body with a 1 wrench, tighten the conduit fitting and locknut(s).
DO NOT EXCEED 100 POUND-INCHES FOR 5/8 OR 3/4 HOUSINGS.
MAINTENANCE:
This component requires no maintenance or recalibration other than periodic checks to ensure
that it is relatively clean and secure (no loose locknuts).
USER PRECAUTIONS:
Contact between the sensor and a rotating target may cause damage to the sensor. Always adjust
the air gap between the sensor tip and the target while the target is motionless with its largest
diametrical feature in front of the sensor. After the adjustment, slowly rotate the target by hand, if
possible, to ensure that there is no contact due to run out.
SIZE
EF-001-02-F1 REV A
CODE IDENT.
NUMBER
1XP56
DWG NO.:
960-0112-001
REV D
SHEET 3