Sample Inspection Report
Sample Inspection Report
NI
NP
NI=Not Inspected
NP=Not Present
D=Deficient
Inspection Item
I. STRUCTURAL SYSTEMS
A. Foundations
Type of Foundation(s): Post tension slab-on-grade
Comments:
There has been differential movement of the post tension foundation slab as indicated by separation of the frieze board at some
of the corners, cracks in the interior gypsum board at joints in the walls, miss aligned door frames, etc.
Since at the time of the inspection there was no serious problem with the frame structure or serious functional problems resulting
from the foundation movement, underpinning and leveling the foundation was not considered to be a structural or functional
necessity at this time and is not required provided that you find the symptoms of the foundation movement which has occurred to
be acceptable.
Since the variation of the moisture content of the soil supporting the foundation can be a significant factor contributing to
continuing movement a proper lawn maintenance program may aid in minimizing foundation problems in the future. The chipped
concrete at the corners of the foundation slab were not considered to be the result of a structural problem requiring repair.
There has been differential movement of the garage foundation slab as indicated by cracks in the gypsum board covering the
interior walls, cracks in the interior gypsum board at joints in the walls, cracks in the gypsum board on the ceiling, etc.
Since at the time of the inspection there was no serious problem with the frame structure or serious functional problems resulting
from the foundation movement, underpinning and leveling the foundation was not considered to be a structural or functional
necessity at this time and is not required provided that you find the symptoms of the foundation movement which has occurred to
be acceptable.
Since the variation of the moisture content of the soil supporting the foundation can be a significant factor contributing to
continuing movement a proper lawn maintenance program may aid in minimizing foundation problems in the future.
Page 1 of 8
Report Identification:
I=Inspected
I NI NP
NI=Not Inspected
D
NP=Not Present
D=Deficiency
Inspection Item
has been applied at the joints between the roof surface and the siding above the roof surface suggests that the joints were not
flashed properly and/or that there have been leaks. J flashing is no longer an acceptable type of flashing. The decking and
underlayment is not installed properly at some of the eaves where checked. Debris, if allowed to collect and remain on the roof
surface, particularly in the valleys, will cause deterioration of the shingles and, eventually roof leaks. The debris should be
removed from the roof surface and the shingles checked for deterioration.
Flashing damaged
Remove debris
Sealant applied
J flashing
Missing insulation
Hole in column
Page 2 of 8
Report Identification:
I=Inspected
I NI NP
NI=Not Inspected
D
NP=Not Present
D=Deficiency
Inspection Item
H. Windows Comments:
Some of the glazing strips are damaged at the west window. The lintels in the brick veneer above the windows are rusted.
There are cracks in the brick veneer adjacent to the lintel above the west window. The 2nd floor front bedroom window will not
lock.
Rusted lintel
Page 3 of 8
Report Identification:
I=Inspected
I NI NP
NI=Not Inspected
D
NP=Not Present
D=Deficiency
Inspection Item
Aluminum or copper?
Double lugging
Double lugging
No connector at disposal
Page 4 of 8
Report Identification:
I=Inspected
I NI NP
NI=Not Inspected
D
NP=Not Present
D=Deficiency
Inspection Item
Cover missing
A. Heating Equipment
Type of Systems: Central Forced Air Furnace Zoned
Energy Sources: Gas-House; Electricity-Garage
Comments:
House systems
The house heating systems were functioning as intended at the time of the inspection. NOTE: The heat exchanger on this type
furnace can not be checked for cracks properly without disassembling the furnace. The inspector did not disassemble the furnaces.
There are no drip legs at the gas connectors for either system.
No drip legs
Garage system
An adequate rise in temperature across the garage heating unit indicated that the heating system was functioning properly at the
time of the inspection.
B. Cooling Equipment
Type of Systems: Central Forced Air System
Comments:
Page 5 of 8
Report Identification:
I=Inspected
I NI NP
NI=Not Inspected
D
NP=Not Present
D=Deficiency
Inspection Item
Garage system
The condensing unit did not work. The condensing unit is rusted at the top. The suction line is not insulated properly at the
condensing unit.
Duct tape
Page 6 of 8
Report Identification:
I=Inspected
I NI NP
NI=Not Inspected
D
NP=Not Present
D=Deficiency
Inspection Item
No visible problem.
V. APPLIANCES
A Dishwashers Comments:
The discharge hose is not looped above the bottom of the kitchen sink. The dishwasher is noisy when operating.
Cover damaged
Page 7 of 8
Report Identification:
I=Inspected
I NI NP
NI=Not Inspected
D
NP=Not Present
D=Deficiency
Inspection Item
C. Outbuildings Comments:
F. Other Comments:
The intercom does not work. The security system was not in the scope of this inspection.
Page 8 of 8