Professional Documents
Culture Documents
Cci Valve 100DSV
Cci Valve 100DSV
Cci Valve 100DSV
100DSV for
Spraywater
Control
Applications
Save Energy
control valves are the final control elements in the control of the Superheat &
Stop Costly
Maintenance Cycles
Operate at high pressure drops (up to 3500 psi or 240 bar) without
damaging the trim components.
Reheater
Reheater
Spray Control
Valve
Heat Rate Losses. Leaking spray water valves result in lowering the
throttle steam temperature. The lower temperatures affect the heat rate
H.P.
Turbine
I.P.
Turbine
Secondary
Superheater
Primary
Superheater
Superheater
Spray Control
Valve
Economizer
Area of Boiler
Deagrator
Feedwater
Regulator
Valve
Boiler
Feedpump
Condensate
Pump
DA Level
Control Valve
Hot We
Vvc
P1
inlet pressure
High trim exit velocities are responsible for erosion damage in control valves
Vvc
(erosion is proportional to the 3rd or 4th power of velocity). The CCI DRAG
valve eliminates trim and body damage caused by erosion by incorporating
V1
inlet velocity
Pvc
Pv flashpoint
V2 outlet velocity
multiple tortuous flow paths designed to limit the trim exit velocities. Each
P2 outlet pressure
flow path has a series of turns which break up the pressure drop across the
valve into multiple stages. The flow path has expanding passages to reduce
Pvc
Pvc
P1
pressure
ft/s
m/s
100
30
75
23
V2 outlet velocity
inlet velocity
P2 outlet pressure
Pv
flashpoint
Delta P
Psi
Recommended velocity
/ turns
3 stages
ft / sec
velocity
ft / sec
turns
600 100
155
105
100
1500 100
259
172
100
10
2400 100
331
233
100
12
4200 100
441
302
100
16
Stem Packing
Multiple teflon packing with
graphite guide spacer.
Spindle
Inconel 718
Multi-stage DRAG control
element
Disk Stack
Easy-to-Service-Seat
No welding or grinding. Trim can
be inspected, repaired or replaced
quickly and with minimum effort.
Class V Shutoff
Metal seat standard.
Equal Percentage
Benefits
1
DRAG 100DSV
Competitors
6
8
5
3
Components
Item No.
Materials of Construction
Body
A216 WCB
Bonnet
A182-F22
Seat Ring
316 SS
Spindle
Inconel 718
Disk Stack
Inconel 718
Balance Seal
Stem Packing
Gasket
Flexitalic
(Graphite/Stainless Steel)
Pressure Rating
ANSI 2500
Body Configuration
500 F (260 C)
Flow Direction
Over-the-plug (Flow-to-close)
Rangeability
100:1
Actuator
Failure Mode
As shown
Shutoff
Notes:
1. All buttweld end connections in accordance with ANSI B16.25
2. All socket weld end connections in accordance with ANSI B16.11
3. Use CCIs Valsiz program for sizing and selection.
Dimension
in (mm)
Normal Size: 1 in
Normal Size: 2 in
Trim: 1.5 in
Angle
Globe
Angle
Globe
37 in (940 mm)
44 in (1120 mm)
-
Weight
Rated CV
1 in (25.4 mm)
200 lbs
(90 kg)
Reduced Trim
0.60
1.60
4.60
10.60
Full Trim
0.90
4.90
11.70
32.00
Valve Stroke
1.5 in.
(38 mm)
2.5 in.
(65 mm)
BW
Connection Per ANSI B16.25
SW
Connection Per ANSI B16.10
CCI Korea
Telephone: 82 31 980 9800
Fax: 82 31 985 0552
26-17, Pungmu-Dong
Gimpo City, Kyunggi-Do 415-070
Republic of Korea
CCI Japan
Telephone: 81 726 41 7197
Fax: 81 726 41 7198
194-2, Shukunosho
Ibaraki-City, Osaka 567-0051
Japan
CCI Sweden
(BTG Valves)
Telephone: 46 533 689 600
Fax: 46 533 689 601
Box 603
SE-661 29 Sffle
Sweden
CCI Austria
(Spectris Components GmbH)
Telephone: 43 1 869 27 40
Fax: 43 1 865 36 03
Carlbergergasse 38/Pf.19
AT-1233 Vienna
Austria
CCI Italy
(STI)
Telephone: 39 035 29289
Fax: 39 035 2928246
Via G. Pascoli 10 A-B
24020 Gorle, Bergamo
Italy
Contact us at:
info@ccivalve.com
Visit us online at:
www.ccivalve.com
DRAG is a registered trademark of CCI.
2003 CCI
316 01/03 7K